期刊文献+
共找到533篇文章
< 1 2 27 >
每页显示 20 50 100
Optimized online filter stack spectrometer for ultrashort X-ray pulses
1
作者 Jia-Xing Wen Ge Ma +17 位作者 Ming-Hai Yu Yu-Chi Wu Yong-Hong Yan Shao-Yi Wang Huai-Zhong Gao Lu-Shan Wang Yu-Gang Zhou Qiang Li Yue Yang Fang Tan Xiao-Hui Zhang Jie Zhang Wen-Bo Mo Jing-Qin Su Wei-Min Zhou Yu-Qiu Gu Ming Zeng Zong-Qing Zhao 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第5期85-98,共14页
Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for c... Currently,with the advent of high-repetition-rate laser-plasma experiments,the demand for online diagnosis for the X-ray spectrum is increasing because the laser-plasma-generated X-ray spectrum is very important for characterizing electron dynamics and applications.In this study,scintillators and silicon PIN(P-type–intrinsic-N-type semiconductor)diodes were used to construct a wideband online filter stack spectrometer.The X-ray sensor and filter arrangement was optimized using a genetic algorithm to minimize the condition number of the response matrix.Consequently,the unfolding error was significantly reduced based on numerical experiments.The detector responses were quantitatively calibrated by irradiating the scintillator and PIN diode with various nuclides and comparing the measuredγ-ray peaks.A prototype 15-channel spectrometer was developed by integrating an X-ray detector with front-and back-end electronics.The prototype spectrometer could record X-ray pulse signals at a repetition rate of 1 kHz.Furthermore,an optimized spectrometer was employed to record the real-time spectra of laser-driven bremsstrahlung sources.This optimized spectrometer offers a compact solution for spectrum diagnostics of ultrashort X-ray pulses,exhibiting improved accuracy in terms of spectrum measurements and repetition rates,and could be widely used in next-generation high-repetition-rate high-power laser facilities. 展开更多
关键词 Filter stack spectrometer Laser plasma diagnostics x-ray diagnostics Scintillator PIN diode
下载PDF
Design and calibration of an elliptical crystal spectrometer for the diagnosis of proton-induced x-ray emission(PIXE)
2
作者 方言律 李东彧 +9 位作者 程浩 高原 申泽清 杨童 李昱泽 夏亚东 晏炀 颜莎 林晨 颜学庆 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期220-225,共6页
Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spur... Laser-driven proton-induced x-ray emission(laser-PIXE) is a nuclear analysis method based on the compact laser ion accelerator. Due to the transient process of ion acceleration, the laser-PIXE signals are usually spurted within nanoseconds and accompanied by strong electromagnetic pulses(EMP), so traditional multi-channel detectors are no longer applicable.In this work, we designed a reflective elliptical crystal spectrometer for the diagnosis of laser-PIXE. The device can detect the energy range of 1 keV–11 ke V with a high resolution. A calibration experiment was completed on the electrostatic accelerator of Peking University using samples of Al, Ti, Cu, and ceramic artifacts. The detection efficiency of the elliptical crystal spectrometer was obtained in the order of 10-9. 展开更多
关键词 elliptical crystal spectrometer proton-induced x-ray emission applications of laser ion accelera-tion
下载PDF
Accuracy analysis of iron content of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum
3
作者 WANG Jingjing CHEN Yanfei 《Baosteel Technical Research》 CAS 2023年第4期35-40,共6页
The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectro... The accuracy(repeatability and reproducibility) of the iron content analysis of galvanized coating using an X-ray fluorescence spectrometer with an L-spectrum is not better than that of flame atomic absorption spectrometry, sometimes it exceeds the quality control limit.Influences, such as current, voltage, equipment(internal circulating water, 10%CH4+90%Ar, and vacuum) checking, instrument monitoring, sample cleaning, and oper-ators, were investigated by means of 6-sigma and lean operations to improve accuracy. 展开更多
关键词 x-ray fluorescence spectrometer Lspectrum galvanized coating iron content
下载PDF
Readout electronics for a high-resolution soft X-ray spectrometer based on silicon drift detector 被引量:3
4
作者 Er-Lei Chen Chang-Qing Feng +4 位作者 Shu-Bin Liu Chun-Feng Ye Dong-Dong Jin Jian Lian Hui-Jun Hu 《Nuclear Science and Techniques》 SCIE CAS CSCD 2017年第1期94-99,共6页
The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly co... The readout electronics for a prototype soft X-ray spectrometer based on silicon drift detector(SDD),for precisely measuring the energy and arrival time of X-ray photons is presented in this paper.The system mainly consists of two parts,i.e.,an analog electronics section(including a pre-amplifier,a signal shaper and filter,a constant fraction timing circuit,and a peak hold circuit)and a digital electronics section(including an ADC and a TDC).Test results with X-ray sources show that an energy dynamic range of 1-10 keV with an integral nonlinearity of less than 0.1%can be achieved,and the energy resolution is better than 160 eV @ 5.9 keV FWHM.Using a waveform generator,test results also indicate that time resolution of the electronics system is about 3.7 ns,which is much less than the transit time spread of SDD(<100 ns)and satisfies the requirements of future applications. 展开更多
关键词 energy and time measurement SOFT x-ray detection Silicon DRIFT DETECTOR READOUT ELECTRONICS
下载PDF
Spectrometer of hard X-ray imager payload onboard the ASO-S mission 被引量:1
5
作者 Yan Zhang Jian-Hua Guo +5 位作者 Zhe Zhang Deng-Yi Chen Yi-Ming Hu Yong-Qiang Zhang Tao Ma Yong-Yi Huang 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第8期92-99,共8页
A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onbo... A spaceborne hard X-ray spectrometer, composed of an array of 99 scintillation detectors and associated readout electronics, has been developed for the hard X-ray imager(HXI). The HXI is one of the three payloads onboard the advanced space-based solar observatory(ASO-S), which is scheduled to be launched in early 2022 as the first Chinese solar satellite. LaBr3 scintillators and photomultiplier tubes with a super bialkali cathode are used to achieve an energy resolution better than 20% at 30 keV.Further, a new multi-channel charge-sensitive readout application-specific integrated circuit guarantees high-frequency data acquisition with low power consumption. This paper presents a detailed design of the spectrometer for the engineering model of the HXI and discusses its noise and linearity performance. 展开更多
关键词 Solar radiation detection x-ray spectrometer HARD x-ray IMAGER ASO-S
下载PDF
Energy-dispersive X-ray Spectroscopy for the Quantitative Analysis of Pyrite Thin Specimens
6
作者 LUO Tingting GUO Yi +4 位作者 DENG Zhao LIU Xiaoqing SUN Zhenya QI Yanyuan YANG Meijun 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2023年第6期1304-1310,共7页
To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantit... To explore ways to improve the accuracy of quantitative analysis of samples in the micrometer to nanometer range of magnitudes,we adopted analytical transmission electron microscopy(AEM/EDS)for qualitative and quantitative analysis of pyrite materials.Additionally,the k factor of pyrite is calculated experimentally.To develop an appropriate non-standard quantitative analysis model for pyrite materials,the experimentally calculated k factor is compared with that estimated from the non-standard quantitative analytical model of the instrument software.The experimental findings demonstrate that the EDS attached to a TEM can be employed for precise quantitative analysis of micro-and nanoscale regions of pyrite materials.Furthermore,it serves as a reference for improving the results of the EDS quantitative analysis of other sulfides. 展开更多
关键词 analytical transmission electron microscopy(AEM) energy dispersive x-ray spectroscopy(EDS) PYRITE thin specimen quantitative analysis
下载PDF
Test of a High Throughput Detector on the X-ray Crystal Spectrometer of the EAST 被引量:1
7
作者 吕波 石跃江 +9 位作者 王福地 万宝年 Manfred BITTER Kenneth W. HILL Sang-gon LEE 李颖颖 符佳 张继宗 徐经翠 沈永才 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期97-100,共4页
An attempt was made to improve the spatio-temporal resolution of the tangen- tial X-ray crystal spectrometer (XCS) on the Experimental Advanced Superconducting Tokamak (EAST) by evaluating experimentally the appli... An attempt was made to improve the spatio-temporal resolution of the tangen- tial X-ray crystal spectrometer (XCS) on the Experimental Advanced Superconducting Tokamak (EAST) by evaluating experimentally the applicability of a novel X-ray photon detection tech- nology for measuring the satellite spectra of Ar XVII with a high counting rate. High-resolution experimental data on the profiles of ion temperature and plasma rotation velocity facilitate the studies of the mechanisms underlining important physical phenomena, such as plasma heating, L-H transition and momentum transport. Based on silicon diode array and single-photon counting technology, a relatively small area (83.8 x 33.5 mm~) two-dimensional detector was successfully in- stalled and tested in the recent EAST campaign. X-ray photon counting rate higher than 20 MHz was observed for the first time, and high quality satellite spectra were recorded for ion temperature and plasma rotation measurement, indicating that the new technology is suitable for the next-step high-resolution XCS on EAST, and the deployment of a detector array with a much larger X-ray sensing area is planned for better plasma coverage. 展开更多
关键词 x-ray crystal spectrometer high resolution ion temperature plasma rotation
下载PDF
Design of Time-Resolved Shifted Dual Transmission Grating Spectrometer for the X-Ray Spectrum Diagnostics 被引量:1
8
作者 王保清 易涛 +6 位作者 王传珂 朱效立 李廷帅 李晋 刘慎业 江少恩 丁永坤 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第7期781-785,共5页
A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which... A new time-resolved shifted dual transmission grating spectrometer (SDTGS) is designed and fabricated in this work. This SDTGS uses a new shifted dual transmission grating (SDTG) as its dispersive component, which has two sub transmission gratings with different line densities, of 2000 lines/mm and 5000 lines/mm. The axes of the two sub transmission gratings in SDTG are horizontally and vertically shifted a certain distance to measure a broad range of 0.1-5 keV time-resolved X-ray spectra. The SDTG has been calibrated with a soft X-ray beam of the synchrotron radiation facility and its diffraction efficiency is also measured. The designed SDTGS can take full use of the space on a record panel and improve the precision for measuring spatial and temporal spectrum simultaneously. It will be a promising application for accurate diagnosis of the soft X-ray spectrum in inertial confinement fusion. 展开更多
关键词 shifted dual transmission grating spectrometer GRATING x-ray spectra diag-nosis of the soft x-ray spectrum
下载PDF
Research of CdZnTe detector based portable energy dispersive spectrometer 被引量:3
9
作者 CHENG Cheng WEI Yong-Bo XU Hui-Chao ZHAO Cui-Lan ZHANG Jin-Zhou PU Shi-Jie JIANG Da-Zhen 《Nuclear Science and Techniques》 SCIE CAS CSCD 2006年第2期106-112,共7页
A kind of excellent CdZnTe crystal has been grown in Yinnel Tech, Inc. in recent years. Based on these CdZnTe crystals and some new techniques, a portable energy-dispersive spectrometer has been constructed which has ... A kind of excellent CdZnTe crystal has been grown in Yinnel Tech, Inc. in recent years. Based on these CdZnTe crystals and some new techniques, a portable energy-dispersive spectrometer has been constructed which has yielded good results. CdZnTe detector has a 3% relative resolution in high-energy field and can detect gamma rays at room temperature. An integrated circuit based on preamplifier and shaping amplifier chips is connected to the detector. Voltage pulses are transformed into digital signals in MCA (multichannel analyzer) and are then transmitted to com- puter via USB bus. Data process algorithms are improved in this spectrometer. Fast Fourier transform (FFT) and nu- merical differentiation (ND) are used in energy peak’s searching program. Sampling-based correction technique is used in X-ray energy calibration. Modified Gaussian-Newton algorithm is a classical method to solve nonlinear curve fitting problems, and it is used to compute absolute intensity of each detected characteristic line. 展开更多
关键词 CdZnTe探测器 前置放大器 能量弥散光谱仪 光谱分析
下载PDF
Application of Dual-Energy X-Ray Image Detection of Dangerous Goods Based on YOLOv7
10
作者 Baosheng Liu Fei Wang +1 位作者 Ming Gao Lei Zhao 《Journal of Computer and Communications》 2023年第7期208-225,共18页
X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out wo... X-ray security equipment is currently a more commonly used dangerous goods detection tool, due to the increasing security work tasks, the use of target detection technology to assist security personnel to carry out work has become an inevitable trend. With the development of deep learning, object detection technology is becoming more and more mature, and object detection framework based on convolutional neural networks has been widely used in industrial, medical and military fields. In order to improve the efficiency of security staff, reduce the risk of dangerous goods missed detection. Based on the data collected in X-ray security equipment, this paper uses a method of inserting dangerous goods into an empty package to balance all kinds of dangerous goods data and expand the data set. The high-low energy images are combined using the high-low energy feature fusion method. Finally, the dangerous goods target detection technology based on the YOLOv7 model is used for model training. After the introduction of the above method, the detection accuracy is improved by 6% compared with the direct use of the original data set for detection, and the speed is 93FPS, which can meet the requirements of the online security system, greatly improve the work efficiency of security personnel, and eliminate the security risks caused by missed detection. 展开更多
关键词 x-ray Dangerous Goods Detection High and Low energy Image Fusion ACCURACY Real-Time Detection
下载PDF
Ultrahard X-ray multifunctional application beamline at the SSRF
11
作者 Ke Yang Zhao-Hui Dong +4 位作者 Chun-Yin Zhou Zi-Long Zhao Dong-Xu Liang Sai-Chao Cao Ai-Guo Li 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第6期14-25,共12页
The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray di... The ultrahard X-ray multifunctional application beamline(BL12SW)is a phase-II beamline project at the Shanghai Syn-chrotron Radiation Facility.The primary X-ray techniques used at the beamline are high-energy X-ray diffraction and imaging using white and monochromatic light.The main scientific objectives of ultrahard X-ray beamlines are focused on two research areas.One is the study of the structural properties of Earth’s interior and new materials under extreme high-temperature and high-pressure conditions,and the other is the characterization of materials and processes in near-real service environments.The beamline utilizes a superconducting wiggler as the light source,with two diamond windows and SiC discs to filter out low-energy light(primarily below 30 keV)and a Cu filter assembly to control the thermal load entering the subsequent optical components.The beamline is equipped with dual monochromators.The first was a meridional bending Laue monochromator cooled by liquid nitrogen,achieving a full-energy coverage of 30-162 keV.The second was a sagittal bending Laue monochromator installed in an external building,providing a focused beam in the horizontal direction with an energy range of 60-120 keV.There were four experimental hutches:two large-volume press experimental hutches(LVP1 and LVP2)and two engineering material experimental hutches(ENG1 and ENG2).Each hutch was equipped with various near-real service conditions to satisfy different requirements.For example,LVP1 and LVP2 were equipped with a 200-ton DDIA press and a 2000-ton dual-mode(DDIA and Kawai)press,respectively.ENG1 and ENG2 provide in situ tensile,creep,and fatigue tests as well as high-temperature conditions.Since June 2023,the BL12SW has been in trial operation.It is expected to officially open to users by early 2024. 展开更多
关键词 Shanghai Synchrotron Radiation Facility Ultrahard x-ray High energy diffraction High energy imaging Engineering materials Earth science
下载PDF
Readout electronics of a prototype spectrometer for measuring low-energy ions in solar wind plasma 被引量:1
12
作者 Di Yang Zhe Cao +4 位作者 Xi Qin Xin-Jun Hao Shu-Bin Liu Chang-Qing Feng Qi An 《Nuclear Science and Techniques》 SCIE CAS CSCD 2016年第6期130-136,共7页
Readout electronics is developed for a prototype spectrometer for in situ measurement of low-energy ions of30 e V/e–20 ke V/e in the solar wind plasma.A low-noise preamplifier/discriminator(A111F) is employed for eac... Readout electronics is developed for a prototype spectrometer for in situ measurement of low-energy ions of30 e V/e–20 ke V/e in the solar wind plasma.A low-noise preamplifier/discriminator(A111F) is employed for each channel to process the signal from micro-channel plate(MCP) detectors.A high-voltage(HV) supply solution based on a HV module and a HV optocoupler is adopted to generate a fast sweeping HV and a fixed HV.Due to limitation of telemetry bandwidth in space communication,an algorithm is implemented in an FPGA(field programmable gate array) to compress the raw data.Test results show that the electronics achieves a 1 MHz event rate and a large input dynamic range of 95 p C.A slew rate of 0.8 V/ls and an integral nonlinearity of 0.7-LSB for the sweeping HV,and a precision of less than 0.8 % for the fixed HV are obtained.A vacuum beam test shows an energy resolution of 12 ± 0.7 % full width at half maximum(FWHM) is achieved,and noise counts are less than10/sec,indicating that the performance meets the physical requirement. 展开更多
关键词 低能离子 等离子体 原位测量 电子学 光谱仪 太阳风 读出 原型
下载PDF
Two-dimensional particle-in-cell modeling of blow-off impulse by X-ray irradiation
13
作者 Ruibo Li Jin-Long Jiao +3 位作者 Hui Luo Dezhi Zhang Dengwang Wang Kai Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期53-69,共17页
Space objects such as spacecraft or missiles may be exposed to intense X-rays in outer space,leading to severe damage.The reinforcement of these objects to reduce the damage caused by X-ray irradiation is a significan... Space objects such as spacecraft or missiles may be exposed to intense X-rays in outer space,leading to severe damage.The reinforcement of these objects to reduce the damage caused by X-ray irradiation is a significant concern.The blow-off impulse(BOI)is a crucial physical quantity for investigating material damage induced by X-ray irradiation.However,the accurate calculation of BOI is challenging,particularly for large deformations of materials with complex configurations.In this study,we develop a novel two-dimensional particle-in-cell code,Xablation2D,to calculate BOIs under far-field X-ray irradiation.This significantly reduces the dependence of the numerical simulation on the grid shape.The reliability of this code is verified by simulation results from open-source codes,and the calculated BOIs are consistent with the experimental and analytical results. 展开更多
关键词 x-ray irradiation energy deposition Blow-off impulse Particle in cells
下载PDF
High performance streaked X-ray spectrometer for research of laser-produced plasmas
14
作者 Guo Luting Wei Minxi +8 位作者 Hu Xin Deng Keli Chen Tao Deng Bo Zhang Lu Zhao Yang Li Jin Xiao Shaoqiu Liu Shenye 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第2期52-55,共4页
In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic int... In order to mitigate the effect of the strong electromagnetic pulse, which produces laser-plasma interactions, we designed a new streaked X-ray spectrometer (SXS) enclosed within a well-sealed, electromag- netic interference-free cavity. The SXS can cover a wide selection of spectral windows using interchangeable Bragg crystals and by appropriate adjustment of the Bragg angle. The SXS has been used to observe time-re- solved X-ray spectrum in the 2.5 keV to 3.5 keV photon-energy range, resulting in a demonstrated spectral res- olution of about 13 at 2960 eV with a time resolution of 10 ps. The observed time and spectral resolutions dem- onstrate the applicability of the SXS for studies of laser-produced plasmas. 展开更多
关键词 streaked x-ray spectrometer x-ray SPECTRUM PLASMAS BRAGG CRYSTAL
下载PDF
Measurement of tungsten impurity spectra with a two-crystal X-ray crystal spectrometer on EAST
15
作者 何梁 陈俊 +12 位作者 王福地 曹锦佳 张洪明 符佳 李颖颖 李义超 宾斌 余青江 万顺宽 杨进 王勋禹 吕波 龚学余 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第8期14-19,共6页
Spectral measurement of tungsten(W)impurity is essential to study impurity transport.Therefore,an X-ray crystal spectrometer(XCS)on EAST was used to measure the line spectra from highly ionized W ions.On EAST,both pol... Spectral measurement of tungsten(W)impurity is essential to study impurity transport.Therefore,an X-ray crystal spectrometer(XCS)on EAST was used to measure the line spectra from highly ionized W ions.On EAST,both poloidal XCS and tangential XCS have been developed to measure the plasma temperature as well as the rotation velocity.Recently,He-like and H-like argon spectra have also been obtained using a two-crystal setup.W lines are identified in this study.Through a careful analysis,the W lines of 3.9336,3.9321,and 3.664(A)are found to be diffracted by He-like or H-like crystals.The lines are confirmed with the NIST database.We also calculated the ion temperature with Doppler broadening of these lines.The ion temperature from the W lines is entirely consistent with that from Ar line spectra.The measurement of these W line spectra could be used to study W impurity transport in future work. 展开更多
关键词 TUNGSTEN SPECTRA x-ray CRYSTAL spectrometer two-crystal
下载PDF
Measurement of impurity lines with two-crystal x-ray spectrometers on EAST
16
作者 杨新帅 胡睿佶 +8 位作者 陈俊 王福地 符佳 李颖颖 张洪明 沈永才 尹相辉 吕波 EAST team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2018年第12期1-8,共8页
To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate cry... To simultaneously measure the He-like and H-like argon spectra, a two-crystal assembly has been deployed to replace the previous single crystal on the tangential x-ray crystal spectrometer.By selecting appropriate crystals with similar Bragg angles, plasma temperature in the range of 0.5 keV≤Te≤10 keV and rotation can be diagnosed based on the He-like and H-like argon spectra. However, due to the added complexity in the two-crystal assembly in which the spectra might be diffracted by two crystals, some additional impurity lines were identified. For example,tungsten(W) lines in different ionization states were diffracted by the He-like and H-like crystal.Additional molybdenum(Mo) lines in the wavelength range of He-like and H-like argon spectra lines were also summarized. The existence of these additional lines caused the fitted temperature to be different from the true values. This paper presents the identified lines through a comparison with available database, which should be included in the fitting procedure. 展开更多
关键词 plasma diagnostics x-ray two-crystal spectrometer Doppler broadening dielectronicsatellite
下载PDF
A High-Efficiency X-Ray Crystal Spectrometer for X-Ray Thomson Scattering
17
作者 张小丁 张继彦 +4 位作者 杨国洪 韦敏习 胡广月 赵斌 郑坚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第8期755-759,共5页
Highly oriented pyrolitic graphite (HOPG) has high X-ray diffraction efficiency due to its unique mosaic crystal structure, and thus is very suitable for its application to X-ray Thomson scattering measurement of so... Highly oriented pyrolitic graphite (HOPG) has high X-ray diffraction efficiency due to its unique mosaic crystal structure, and thus is very suitable for its application to X-ray Thomson scattering measurement of solid-density plasmas. In this article, by using the K-shell X-ray source from laser-produced Ti plasma, the properties of the HOPG spectrometer are characterized and compared with those of the flat Pentaerythritol (PET) spectrometer. The results show that the diffraction efficiency of the HOPG spectrometer under focusing condition is an order higher than that of the PET spectrometer, while the spectral resolution of the HOPG is about 320, high enough to be used in the measurement of X-ray Thomson scattering spectra. 展开更多
关键词 crystal spectrometer highly oriented pyrolytic graphite x-ray Thomson scattering
下载PDF
Ray tracing method for the grazing incidence flat-field imaging soft X-ray spectrometer
18
作者 董全力 刘运全 +2 位作者 腾浩 李英骏 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第6期392-397,共6页
A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate co... A ray tracing method is introduced for helping adjustment and spectra analysis of the grazing incidence flat-field imaging soft X-ray spectrometer. For a single point source, the spectra images obtained by separate components, the toroidal mirror, and the grazing incidence flat-field concave grating with varied line spaces are given respectively. The calculated spectral images of the single point source by the spectrometer are also given for comparison with measurements with different experimental alignments. 展开更多
关键词 flat-field grating spectrometer soft x-ray diagnosis
下载PDF
A New Method for Measurements of the Poloidal Rotation Velocities and Wavelength Calibration of X-ray Imaging Crystal Spectrometer in Magnetic Fusion Devices
19
作者 石跃江 吕波 +3 位作者 王福地 M.BITTER K.W.HILL 叶民友 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第4期265-267,共3页
A new simple method is presented for the wavelength calibration and measurement of poloidal rotation velocities with X-ray imaging crystal spectrometer(XICS)in magnetic fusion devices.In this method,the toroidal rot... A new simple method is presented for the wavelength calibration and measurement of poloidal rotation velocities with X-ray imaging crystal spectrometer(XICS)in magnetic fusion devices.In this method,the toroidal rotation of plasma is applied for high precise alignment and wavelength calibration of the poloidal XICS.The measurement threshold of poloidal rotation velocity can be lowered to 1-3 km/s with this method. 展开更多
关键词 x-ray imaging crystal spectrometer wavelength calibration poloidal rotation velocity
下载PDF
A study on some elements and their phases in sediments of Changjiang Estuary by X-ray spectrometer and X-ray diffractometer
20
作者 Han Jiancheng, Li Li, Chen Qiming, Wu Xinran, Chen Banglin and Han QingpingDepartment of Chemistry, East China Normal University, Shanghai 200062, China 《Acta Oceanologica Sinica》 SCIE CAS CSCD 1997年第1期121-125,共5页
INTRODUCTIONThe studies on the quantitative distribution of the conventional elements and their phases in the sediments of the Changjiang Estuary are of great importance to the understanding of the chemical processes ... INTRODUCTIONThe studies on the quantitative distribution of the conventional elements and their phases in the sediments of the Changjiang Estuary are of great importance to the understanding of the chemical processes of ion exchange, absorption, desorption and flocculation in the estuary. 展开更多
关键词 A study on some elements and their phases in sediments of Changjiang Estuary by x-ray spectrometer and x-ray diffractometer
下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部