期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Application of fractal theory in detecting low current faults of power distribution system in coal mines 被引量:5
1
作者 LIU Jian-hua LIANG Rui WANG Chong-lin FAN Di-peng 《Mining Science and Technology》 EI CAS 2009年第3期321-325,共5页
Single-phase low current grounding faults areoften seen in power distribution system of coal mines.These faults are difficult to reliably identify.We propose a new method of single-phase ground fault protection based ... Single-phase low current grounding faults areoften seen in power distribution system of coal mines.These faults are difficult to reliably identify.We propose a new method of single-phase ground fault protection based upon a discernible matrix of the fractal dimension associated with line currents.The method builds on existing selective protection methods.Faulted feeders are distinguished using differences in the zero-sequence transient current fractal dimension.The current signals were first processed through a fast Fourier transform and then the characteristics of a faulted line were identified using a discernible matrix.The method of calculation is illustrated.The results show that the method involves simple calculations, is easy to do and is highly accurate.It is, therefore, suitable for distribution networks having different neutral grounding modes. 展开更多
关键词 low current faults zero sequence transient current fractal dimension discernible matrix selective protection
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
2
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection zero sequence voltage detection
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部