The application of the vector magnetometry based on nitrogen-vacancy(NV)ensembles has been widely investigatedin multiple areas.It has the superiority of high sensitivity and high stability in ambient conditions with ...The application of the vector magnetometry based on nitrogen-vacancy(NV)ensembles has been widely investigatedin multiple areas.It has the superiority of high sensitivity and high stability in ambient conditions with microscale spatialresolution.However,a bias magnetic field is necessary to fully separate the resonance lines of optically detected magneticresonance(ODMR)spectrum of NV ensembles.This brings disturbances in samples being detected and limits the rangeof application.Here,we demonstrate a method of vector magnetometry in zero bias magnetic field using NV ensembles.By utilizing the anisotropy property of fluorescence excited from NV centers,we analyzed the ODMR spectrum of NVensembles under various polarized angles of excitation laser in zero bias magnetic field with a quantitative numerical modeland reconstructed the magnetic field vector.The minimum magnetic field modulus that can be resolved accurately is downto~0.64 G theoretically depending on the ODMR spectral line width(1.8 MHz),and~2 G experimentally due to noisesin fluorescence signals and errors in calibration.By using 13C purified and low nitrogen concentration diamond combinedwith improving calibration of unknown parameters,the ODMR spectral line width can be further decreased below 0.5 MHz,corresponding to~0.18 G minimum resolvable magnetic field modulus.展开更多
The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appeara...The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appearance of harmonic peaks, the frequency difference δf between drive mode and sense mode must be less than 1/(2Qy). In order to eliminate the effects of the quadrature error and the offset error, as well as the inherent non- linearity in the capacitance-type sensors, a closed-loop feedback control circuit with quadrature correction is designed. The experimental results indicate that the quadrature error and offset error are corrected. By comparing with open-loop detection, the closed-loop feedback control circuit with quadrature correction decreases the non-linearity of the scale factor from 16. 02% to 0. 35 %, widens the maximum rate capability from ± 270 (°)/s to ± 370 (°)/s and increases the stability of zero bias from 155. 2 (°)/h to 60. 6 (°)/h.展开更多
A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reach...A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reaches greater than l0 000. Self-oscillating and closed-loop methods based on electrostatic force feedback are adopted in both measure and control circuits. Both single side driving and sensing methods are used to simplify the drive circuit. These dual channel decomposition and reconstruction closed loops are applied in sense modes. The testing results demonstrate that useful signals and guadrature signals do not interact with each other because of the decoupling of their phases. Under the condition of a scale factor of 9. 6 mV/((°) .s), in a full measurement range of±300 (°)/s, the zero bias stability reaches 28 (°)/h with a nonlinear coefficient of 400 × 10^-6 and a simulated bandwidth of more than 100 Hz. The overall performance is improved by two orders of magnitude in comparison to that at atmospheric pressure.展开更多
Two broadband detectors at W-band and D-band are analyzed and designed with low barrier Schottky diodes. The input circuit of the detectors is realized by low and high impedance microstrip lines, and their output circ...Two broadband detectors at W-band and D-band are analyzed and designed with low barrier Schottky diodes. The input circuit of the detectors is realized by low and high impedance microstrip lines, and their output circuit is composed of a radio frequency (RF) bandstop filter and a tuning line for optimum reflection phase of the RF signal. S-parameters of the complete circuit are exported to a circuit simulator for voltage sensitivity analysis. For the W band detectors, the highest measured voltage sensitivity is 11800 mV/mW at 100 GHz, and the sensitivity is higher than 2000 mV/mW in 80-104 GHz. Measured tangential sensitivity (TSS) is higher than -38 dBm, and its linearity is superior than 0.99992 at 95 GHz. For the D band detector, the highest measured voltage sensitivity is 1600 mV/mW, and the typical sensitivity is 600 mV/mW in 110-170 GHz. TSS is higher than -29 dBm, and its linearity is superior than 0.99961 at 150 GHz.展开更多
In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure c...In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure condition of large range MEMS accelerometers in high temperature environment,the corresponding accelerated degradation test is designed. According to the degradation condition of zero bias and scale factor,multiple dependent reliability estimation of large range MEMS accelerometers is carried out. The results show that the multiple dependent reliability estimation of the large range MEMS accelerometers can improve the accuracy of the estimation and get more accurate results.展开更多
基金supported by the National Key R&D Program of China(Grant Nos.2021YFB3202800 and 2023YF0718400)Chinese Academy of Sciences(Grant No.ZDZBGCH2021002)+2 种基金Chinese Academy of Sciences(Grant No.GJJSTD20200001)Innovation Program for Quantum Science and Technology(Grant No.2021ZD0303204)Anhui Initiative in Quantum Information Technologies,USTC Tang Scholar,and the Fundamental Research Funds for the Central Universities.
文摘The application of the vector magnetometry based on nitrogen-vacancy(NV)ensembles has been widely investigatedin multiple areas.It has the superiority of high sensitivity and high stability in ambient conditions with microscale spatialresolution.However,a bias magnetic field is necessary to fully separate the resonance lines of optically detected magneticresonance(ODMR)spectrum of NV ensembles.This brings disturbances in samples being detected and limits the rangeof application.Here,we demonstrate a method of vector magnetometry in zero bias magnetic field using NV ensembles.By utilizing the anisotropy property of fluorescence excited from NV centers,we analyzed the ODMR spectrum of NVensembles under various polarized angles of excitation laser in zero bias magnetic field with a quantitative numerical modeland reconstructed the magnetic field vector.The minimum magnetic field modulus that can be resolved accurately is downto~0.64 G theoretically depending on the ODMR spectral line width(1.8 MHz),and~2 G experimentally due to noisesin fluorescence signals and errors in calibration.By using 13C purified and low nitrogen concentration diamond combinedwith improving calibration of unknown parameters,the ODMR spectral line width can be further decreased below 0.5 MHz,corresponding to~0.18 G minimum resolvable magnetic field modulus.
文摘The reasons for inducing quadrature error and offset error are analyzed and the expressions of quadrature error and offset error are induced. The open-loop system analysis indicates that, in order to avoid the appearance of harmonic peaks, the frequency difference δf between drive mode and sense mode must be less than 1/(2Qy). In order to eliminate the effects of the quadrature error and the offset error, as well as the inherent non- linearity in the capacitance-type sensors, a closed-loop feedback control circuit with quadrature correction is designed. The experimental results indicate that the quadrature error and offset error are corrected. By comparing with open-loop detection, the closed-loop feedback control circuit with quadrature correction decreases the non-linearity of the scale factor from 16. 02% to 0. 35 %, widens the maximum rate capability from ± 270 (°)/s to ± 370 (°)/s and increases the stability of zero bias from 155. 2 (°)/h to 60. 6 (°)/h.
基金The National High Technology Research and Development Program of China (863Program)(No.2002AA812038)the National Defense Pre-Research Support Program (No.41308050109)
文摘A novel closed-loop control strategy of a silicon microgyroscope (SMG) is proposed. The SMG is sealed in metal can package in drive and sense modes and works under the air pressure of 10 Pa. Its quality factor reaches greater than l0 000. Self-oscillating and closed-loop methods based on electrostatic force feedback are adopted in both measure and control circuits. Both single side driving and sensing methods are used to simplify the drive circuit. These dual channel decomposition and reconstruction closed loops are applied in sense modes. The testing results demonstrate that useful signals and guadrature signals do not interact with each other because of the decoupling of their phases. Under the condition of a scale factor of 9. 6 mV/((°) .s), in a full measurement range of±300 (°)/s, the zero bias stability reaches 28 (°)/h with a nonlinear coefficient of 400 × 10^-6 and a simulated bandwidth of more than 100 Hz. The overall performance is improved by two orders of magnitude in comparison to that at atmospheric pressure.
文摘Two broadband detectors at W-band and D-band are analyzed and designed with low barrier Schottky diodes. The input circuit of the detectors is realized by low and high impedance microstrip lines, and their output circuit is composed of a radio frequency (RF) bandstop filter and a tuning line for optimum reflection phase of the RF signal. S-parameters of the complete circuit are exported to a circuit simulator for voltage sensitivity analysis. For the W band detectors, the highest measured voltage sensitivity is 11800 mV/mW at 100 GHz, and the sensitivity is higher than 2000 mV/mW in 80-104 GHz. Measured tangential sensitivity (TSS) is higher than -38 dBm, and its linearity is superior than 0.99992 at 95 GHz. For the D band detector, the highest measured voltage sensitivity is 1600 mV/mW, and the typical sensitivity is 600 mV/mW in 110-170 GHz. TSS is higher than -29 dBm, and its linearity is superior than 0.99961 at 150 GHz.
文摘In the past,only one performance parameter was considered in the reliability estimation of micro-electro-mechanical system (MEMS) accelerometers,resulting in a one-sided reliability evaluation. Aiming at the failure condition of large range MEMS accelerometers in high temperature environment,the corresponding accelerated degradation test is designed. According to the degradation condition of zero bias and scale factor,multiple dependent reliability estimation of large range MEMS accelerometers is carried out. The results show that the multiple dependent reliability estimation of the large range MEMS accelerometers can improve the accuracy of the estimation and get more accurate results.