This paper proposes an efficient, high-tech method of construction of pseudorandom binary sequences generators with a repetition period 2n?for n-bit shift register with a nonlinear feedback function. The developed met...This paper proposes an efficient, high-tech method of construction of pseudorandom binary sequences generators with a repetition period 2n?for n-bit shift register with a nonlinear feedback function. The developed method is illustrated by constructing a nonlinear function feedback shift register. It is proved that the offered method requires the realization of a memory size proportional to n2?that allows making successful use of suitable generators for practical use on the shift register of the longer word.展开更多
Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network str...Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated.展开更多
文摘This paper proposes an efficient, high-tech method of construction of pseudorandom binary sequences generators with a repetition period 2n?for n-bit shift register with a nonlinear feedback function. The developed method is illustrated by constructing a nonlinear function feedback shift register. It is proved that the offered method requires the realization of a memory size proportional to n2?that allows making successful use of suitable generators for practical use on the shift register of the longer word.
文摘Using the neutral grounding method by the resistance in 110?kV system, it can limit the voltage sag and short circuit current when one-phase grounding fault occurred, but it will change the sequence of the network structure and parameters. This paper analyzes the size and distribution of zero sequence voltage and current when one-phase grounding fault occurred in the 110 kV resistance grounding system, and puts forward the grounding protection configuration setting principle of this system combining the power supplying characteristics of 110?kV distribution network. In a reforming substation as an example, the grounding protection of 110 kV lines and transformer have been set and calculated.