Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei...Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.展开更多
Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM...Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy.展开更多
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground...The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.展开更多
Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the ...Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments.展开更多
This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be dimin...This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be diminished using electromagnetic devices, particularly the eZSB (electromagnetic zero-sequence blocking). One important characteristic of this device, which has received particular attention on this research, is its robustness and low cost of construction. Theoretical and experimental results related to the behavior of the electromagnetic blocking devices are presented. The results illustrate the consistence of the theoretical aspects related with the model in the frequency domain, as well as the performance of the blocking devices, reducing zero-sequence harmonic currents, mainly by the conjunct action of the eZSF (electromagnetic zero-sequence harmonic filter), working as a impedance coupler. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests have been carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocker.展开更多
The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-...The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.展开更多
Current and voltage waveforms recorded by intelligent electronic devices(IEDs)are more useful than just performing post-fault analysis.The objective of this paper is to present techniques to estimate the zero-sequence...Current and voltage waveforms recorded by intelligent electronic devices(IEDs)are more useful than just performing post-fault analysis.The objective of this paper is to present techniques to estimate the zero-sequence line impedance of all sections of a three-terminal line and the Thevenin equivalent impedance of the transmission network upstream from the monitoring location using protective relay data collected during short-circuit ground fault events.Protective relaying data from all three terminals may not be always available.Furthermore,the data from each terminal may be unsynchronized and collected at different sampling rates with dissimilar fault time instants.Hence,this paper presents approaches which use unsynchronized measurement data from all the terminals as well as data from only two terminals to estimate the zero-sequence line impedance of all the sections of a three-terminal line.An algorithm to calculate positive-,negative-and zero-sequence Thevenin impedance of the upstream transmission network has also been presented in this paper.The efficacy of the proposed algorithms are demonstrated using a test case.The magnitude error percentage in determining the zero-sequence impedance was less than 1%in the test case presented.展开更多
The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing...The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing detectors based on single method. In this paper, integrative feeder selection strategy—zero sequence current increment method and the direction of transient current— is put forward. Based on the integrative feeder selection strategy, the design of fault-feeder selection device for one-phase-to ground fault on resonance grounding system is presented. For the purpose of testing and validating the operating principle of the device, the experiment of single-phase-to-ground fault has been carried out on the simulation of 1.2 kV power network. The results from many repeat experiments show that stability of the fault selection device is satisfactory.展开更多
With the increased penetration of non-conventionalrenewable energy resources, such as wind power plants (WPPs),into the power system, a lot of interest has been placed on studyingtheir impact for system protection, pl...With the increased penetration of non-conventionalrenewable energy resources, such as wind power plants (WPPs),into the power system, a lot of interest has been placed on studyingtheir impact for system protection, planning and operationsto ensure continued reliability of the electric grid. The impactof WPPs on the grid is typically identified during generationinterconnection studies. One of the challenges faced by protectionand planning engineers, at an early stage in this process, isthat many of the studies involving these power plants must beperformed without specific data available because the equipmentis not built yet. Among all the needed data, a particular interest inthis study is placed on the positive- and zero-sequence impedancesof the main power transformer (MPT) that interconnects a windpower plant to the transmission system due to its contribution toshort-circuit current during ground faults. The most commonlyfound in practice MPT winding configurations is a high-voltagewinding in wye with neutral bushing;a low-voltage windingin wye with neutral bushing without phase shift between thesewindings, and a stabilizing tertiary winding connected in deltathat is not designed for external loading designated as YNyn0+d.Thus, this paper proposes a methodology to estimate the sequenceimpedances of YNyn0+d transformers from a statistical point ofview applying clustering and regression analyses on existing MPTtest report data.展开更多
When high-impedance faults(HIFs)occur in resonant grounded distribution networks,the current that flows is extremely weak,and the noise interference caused by the distribution network operation and the sampling error ...When high-impedance faults(HIFs)occur in resonant grounded distribution networks,the current that flows is extremely weak,and the noise interference caused by the distribution network operation and the sampling error of the measurement devices further masks the fault characteristics.Consequently,locating a fault section with high sensitivity is difficult.Unlike existing technologies,this study presents a novel fault feature identification framework that addresses this issue.The framework includes three key steps:(1)utilizing the variable mode decomposition(VMD)method to denoise the fault transient zero-sequence current(TZSC);(2)employing a manifold learning algorithm based on t-distributed stochastic neighbor embedding(t-SNE)to further reduce the redundant information of the TZSC after denoising and to visualize fault information in high-dimensional 2D space;and(3)classifying the signal of each measurement point based on the fuzzy clustering method and combining the network topology structure to determine the fault section location.Numerical simulations and field testing confirm that the proposed method accurately detects the fault location,even under the influence of strong noise interference.展开更多
In this paper, we investigate the complex oscillation of the higher order differential equation where B0, ...,Bk-1,,F 0 are transcendental meromorpic functions having only finitely many poles. We obtain some precise e...In this paper, we investigate the complex oscillation of the higher order differential equation where B0, ...,Bk-1,,F 0 are transcendental meromorpic functions having only finitely many poles. We obtain some precise estimates of the exponent of convergence of the zero sequence of meromorphic solutions for the above equation.展开更多
The fast and accurate detection of the single-phaseto-ground fault is of great significance for the reliability and safety of the power supply.In this paper,novel algorithms for distribution network protection were pr...The fast and accurate detection of the single-phaseto-ground fault is of great significance for the reliability and safety of the power supply.In this paper,novel algorithms for distribution network protection were proposed with distributed parameters analysis in non-direct grounded systems.At first,novel generating mechanisms of zero-sequence voltage and residual current were proposed.Then the compositions of residue parameters,including residual current and residual admittances,were decomposed in detail.After that,an improved algorithm for a fault resistance calculation of a single phase-to-earth fault was also proposed,and the algorithm is much more convenient as it only needs to measure the variation of the zero-sequence voltage and does not need the prerequisites of the faulty feeder selection.Furthermore,the fault feeder can also be selected by an improved calculation algorithm of zero-sequence admittance of the faulty feeder,which cannot be affected by the asymmetry of the network.Theoretical analysis and the MATALB/Simulink simulation results demonstrate the effectiveness of the proposed algorithms.展开更多
High impedance faults(HIFs) are easy to occur in collective feeders in wind farms and may cause the cascading of wind generators tripping. This kind of faults is difficult to be detected by traditional relay or fuse d...High impedance faults(HIFs) are easy to occur in collective feeders in wind farms and may cause the cascading of wind generators tripping. This kind of faults is difficult to be detected by traditional relay or fuse due to the limited fault current values and the situation is worse in wind farms. The mostly adopted HIF detection algorithms are based on the 3rd harmonic characteristic of the fault zero-sequence currents, whereas these 3rd harmonics are very easy to be polluted by wind power back-to-back converters. In response to this problem, the typical harmonic characteristic of HIF arc flash based on Mayr’s arc model is first analyzed, and the typical fault waveforms of HIF in wind farm are presented. Then the performance of the harmonic based HIF detection algorithm is discussed,and a novel detection algorithm is proposed from the viewpoint of time domain, focusing on the convex and concave characteristic of zero-sequence current at zerocrossing points. A HIFs detection(HIFD) prototype implementing the proposed algorithm has been developed.The sensitivity and security of the algorithm are proved byfield data and RTDS experiments.展开更多
基金supported in part by National Key Research and Development Program of China(2016YFB0900603)Technology Projects of State Grid Corporation of China(52094017000W).
文摘Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs.
基金supported in part by the National Natural Science Foundation of China under Grant 51977099。
文摘Dual three-phase permanent-magnet synchronous machines(DTP-PMSM)connected with a single neutral point provide a loop for zero-sequence current(ZSC).This paper proposes a novel space vector pulse width modulation(SVPWM)strategy to suppress the ZSC.Five vectors are selected as basic voltage vectors in one switching period.The fundamental and harmonic planes and the zero-sequence plane are taken into consideration to synthesis the reference voltage vector.To suppress the ZSC,a non-zero zero-sequence voltage(ZSV)is generated to compensate the third harmonic back-EMF.Rather than triangular carrier modulation,the sawtooth carrier modulation strategy is used to generate asymmetric PWM signals.The modulation range is investigated to explore the variation of modulation range caused by considering the zero-sequence plane.With the proposed method,the ZSC can be considerably reduced.The simulated and experimental results are presented to validate the effectiveness of the proposed modulation strategy.
基金This paper is supported in part by the National Natural Science Foundations of China,and the Major Science and Technology Projects in Yunnan Province under Grant Nos.51667010,51807085,and 202002AF080001.
文摘The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability.
基金Fundamental Research Funds for the Central Universities,China(No.2232019D3-53)Initial Research Funds for Young Teachers of Donghua University,China(104070053029)Shanghai Rising-Star Program,China(No.19QA1400400)。
文摘Compared with the traditional three-phase star connection winding,the open-end winding permanent magnet synchronous motor(OW-PMSM)system with a common direct current(DC)bus has a zero-sequence circuit,which makes the common-mode voltage and the back electromotive force(EMF)harmonic generated by the inverters produce the zero-sequence current in the zero-sequence circuit,and the zero-sequence current has great influence on the operation efficiency and stability of the motor control system.A zero-sequence current suppression strategy is presented based on model predictive current control for OW-PMSM.Through the mathematical model of OW-PMSM to establish the predictive model and the zero-sequence circuit model,the common-mode voltage under different voltage vector combinations is fully considered during vector selection and action time calculation.Then zero-sequence loop constraints are established,so as to suppress the zero-sequence current.In the end,the control strategy proposed in this paper is verified by simulation experiments.
文摘This paper reveals new contributions to the analysis and development of devices for harmonic distortion mitigation. Considering the sequential distribution of harmonic currents, zero-sequence components could be diminished using electromagnetic devices, particularly the eZSB (electromagnetic zero-sequence blocking). One important characteristic of this device, which has received particular attention on this research, is its robustness and low cost of construction. Theoretical and experimental results related to the behavior of the electromagnetic blocking devices are presented. The results illustrate the consistence of the theoretical aspects related with the model in the frequency domain, as well as the performance of the blocking devices, reducing zero-sequence harmonic currents, mainly by the conjunct action of the eZSF (electromagnetic zero-sequence harmonic filter), working as a impedance coupler. In this context, aiming the evaluation of the reliability of the results obtained through mathematical modeling, experimental tests have been carried out using a low-power prototype, highlighting particular aspects related to its function as a zero-sequence harmonic blocker.
基金supported by National Key R&D Program of China(No.2021YFB2401100)the Science and Technology Project of State Grid Corporation of China(No.5211DS22002C).
文摘The cluster DC voltage balancing control adopting zero-sequence voltage injection is appropriate for the starconnected cascaded H-bridge STATCOM because no zerosequence currents are generated in the three-phase three-wire system.However,as the zero-sequence voltage is expressed in trigonometric form,traditional control methods involve many complicated operations,such as the square-root,trigonometric operations,and inverse tangent operations.To simplify cluster voltage balancing control,this paper converts the zero-sequence voltage to the dq frame in a DC representation by introducing a virtually orthogonal variable,and the DC components of the zero-sequence voltage in the dq frame are regulated linearly by proportional integral regulators,rather than being calculated from uneven active powers in traditional controls.This removes all complicated operations.Finally,this paper presents simulation and experimental results for a 400 V±7.5 kvar star-connected STATCOM,in balanced and unbalanced scenarios,thereby verifying the effectiveness of the proposed control.
文摘Current and voltage waveforms recorded by intelligent electronic devices(IEDs)are more useful than just performing post-fault analysis.The objective of this paper is to present techniques to estimate the zero-sequence line impedance of all sections of a three-terminal line and the Thevenin equivalent impedance of the transmission network upstream from the monitoring location using protective relay data collected during short-circuit ground fault events.Protective relaying data from all three terminals may not be always available.Furthermore,the data from each terminal may be unsynchronized and collected at different sampling rates with dissimilar fault time instants.Hence,this paper presents approaches which use unsynchronized measurement data from all the terminals as well as data from only two terminals to estimate the zero-sequence line impedance of all the sections of a three-terminal line.An algorithm to calculate positive-,negative-and zero-sequence Thevenin impedance of the upstream transmission network has also been presented in this paper.The efficacy of the proposed algorithms are demonstrated using a test case.The magnitude error percentage in determining the zero-sequence impedance was less than 1%in the test case presented.
文摘The compensation current of the arc-suppressing coil makes the phase and amplitude of zero-sequence measurement current of the earthed fault feeder to vary. It is very hard to detect the fault feeder by using existing detectors based on single method. In this paper, integrative feeder selection strategy—zero sequence current increment method and the direction of transient current— is put forward. Based on the integrative feeder selection strategy, the design of fault-feeder selection device for one-phase-to ground fault on resonance grounding system is presented. For the purpose of testing and validating the operating principle of the device, the experiment of single-phase-to-ground fault has been carried out on the simulation of 1.2 kV power network. The results from many repeat experiments show that stability of the fault selection device is satisfactory.
文摘With the increased penetration of non-conventionalrenewable energy resources, such as wind power plants (WPPs),into the power system, a lot of interest has been placed on studyingtheir impact for system protection, planning and operationsto ensure continued reliability of the electric grid. The impactof WPPs on the grid is typically identified during generationinterconnection studies. One of the challenges faced by protectionand planning engineers, at an early stage in this process, isthat many of the studies involving these power plants must beperformed without specific data available because the equipmentis not built yet. Among all the needed data, a particular interest inthis study is placed on the positive- and zero-sequence impedancesof the main power transformer (MPT) that interconnects a windpower plant to the transmission system due to its contribution toshort-circuit current during ground faults. The most commonlyfound in practice MPT winding configurations is a high-voltagewinding in wye with neutral bushing;a low-voltage windingin wye with neutral bushing without phase shift between thesewindings, and a stabilizing tertiary winding connected in deltathat is not designed for external loading designated as YNyn0+d.Thus, this paper proposes a methodology to estimate the sequenceimpedances of YNyn0+d transformers from a statistical point ofview applying clustering and regression analyses on existing MPTtest report data.
基金supported in part by the Science and Technology Program of State Grid Corporation of China(No.5108-202218280A-2-75-XG)the Fundamental Research Funds for the Central Universities(No.B200203129)the Postgraduate Research and Practice Innovation Program of Jiangsu Province(No.KYCX20_0432)。
文摘When high-impedance faults(HIFs)occur in resonant grounded distribution networks,the current that flows is extremely weak,and the noise interference caused by the distribution network operation and the sampling error of the measurement devices further masks the fault characteristics.Consequently,locating a fault section with high sensitivity is difficult.Unlike existing technologies,this study presents a novel fault feature identification framework that addresses this issue.The framework includes three key steps:(1)utilizing the variable mode decomposition(VMD)method to denoise the fault transient zero-sequence current(TZSC);(2)employing a manifold learning algorithm based on t-distributed stochastic neighbor embedding(t-SNE)to further reduce the redundant information of the TZSC after denoising and to visualize fault information in high-dimensional 2D space;and(3)classifying the signal of each measurement point based on the fuzzy clustering method and combining the network topology structure to determine the fault section location.Numerical simulations and field testing confirm that the proposed method accurately detects the fault location,even under the influence of strong noise interference.
文摘In this paper, we investigate the complex oscillation of the higher order differential equation where B0, ...,Bk-1,,F 0 are transcendental meromorpic functions having only finitely many poles. We obtain some precise estimates of the exponent of convergence of the zero sequence of meromorphic solutions for the above equation.
基金This work was supported in part by the National Natural Science Foundation of China(No.51177039)in part by the Fundamental Research Funds for the Central Universities(2018B06314)the 111 Intelligence project(B14022).
文摘The fast and accurate detection of the single-phaseto-ground fault is of great significance for the reliability and safety of the power supply.In this paper,novel algorithms for distribution network protection were proposed with distributed parameters analysis in non-direct grounded systems.At first,novel generating mechanisms of zero-sequence voltage and residual current were proposed.Then the compositions of residue parameters,including residual current and residual admittances,were decomposed in detail.After that,an improved algorithm for a fault resistance calculation of a single phase-to-earth fault was also proposed,and the algorithm is much more convenient as it only needs to measure the variation of the zero-sequence voltage and does not need the prerequisites of the faulty feeder selection.Furthermore,the fault feeder can also be selected by an improved calculation algorithm of zero-sequence admittance of the faulty feeder,which cannot be affected by the asymmetry of the network.Theoretical analysis and the MATALB/Simulink simulation results demonstrate the effectiveness of the proposed algorithms.
基金supported in part by National Natural Science Foundation of China(No.51120175001,No.51477084)in part by the Beijing Natural Science Foundation(No.3152016)
文摘High impedance faults(HIFs) are easy to occur in collective feeders in wind farms and may cause the cascading of wind generators tripping. This kind of faults is difficult to be detected by traditional relay or fuse due to the limited fault current values and the situation is worse in wind farms. The mostly adopted HIF detection algorithms are based on the 3rd harmonic characteristic of the fault zero-sequence currents, whereas these 3rd harmonics are very easy to be polluted by wind power back-to-back converters. In response to this problem, the typical harmonic characteristic of HIF arc flash based on Mayr’s arc model is first analyzed, and the typical fault waveforms of HIF in wind farm are presented. Then the performance of the harmonic based HIF detection algorithm is discussed,and a novel detection algorithm is proposed from the viewpoint of time domain, focusing on the convex and concave characteristic of zero-sequence current at zerocrossing points. A HIFs detection(HIFD) prototype implementing the proposed algorithm has been developed.The sensitivity and security of the algorithm are proved byfield data and RTDS experiments.