期刊文献+
共找到5,030篇文章
< 1 2 250 >
每页显示 20 50 100
Protection of Zero-Sequence Power Variation in Mountain Wind Farm Collector Lines Based on Multi-Mode Grounding
1
作者 Hongchun Shu Yaqi Deng +3 位作者 Pulin Cao Jun Dong Hongjiang Rao Zhiqian Bo 《Energy Engineering》 EI 2022年第2期523-538,共16页
The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR ground... The arc-suppression coil(ASC)in parallel low resistance(LR)multi-mode grounding is adopted in the mountain wind farm to cope with the phenomenon that is misoperation or refusal of zero-sequence protection in LR grounding wind farm.If the fault disappears before LR is put into the system,it is judged as an instantaneous fault;while the fault does not disappear after LR is put into the system,it is judged as a permanent fault;the single-phase grounding fault(SLG)protection criterion based on zerosequence power variation is proposed to identify the instantaneous-permanent fault.Firstly,the distribution characteristic of zero-sequence voltage(ZSV)and zero-sequence current(ZSC)are analyzed after SLGfault occurs in multi-mode grounding.Then,according to the characteristics that zero-sequence power variation of non-fault collector line is small,while the zero-sequence power variation of fault collector line can reflect the active power component of fault resistance,the protection criterion based on zero-sequence power variation is constructed.The theoretical analysis and simulation results show that the protection criterion can distinguish the property of fault only by using the single terminal information,which has high reliability. 展开更多
关键词 Mountain wind farm multi-mode grounding collector line single-phase grounding fault zero-sequence power variation
下载PDF
Single-phase-to-ground fault protection based on zero-sequence current ratio coefficient for low-resistance grounding distribution network 被引量:4
2
作者 Jianrui Li Yongli Li +1 位作者 Yonghuan Wang Jinzhao Song 《Global Energy Interconnection》 EI CAS CSCD 2021年第6期564-575,共12页
Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to thei... Definite-time zero-sequence over-current protection is presently used in systems whose neutral point is grounded by a low resistance(low-resistance grounding systems).These systems frequently malfunction owing to their high settings of the action value when a high-impedance grounding fault occurs.In this study,the relationship between the zero-sequence currents of each feeder and the neutral branch was analyzed.Then,a grounding protection method was proposed on the basis of the zero-sequence current ratio coefficient.It is defined as the ratio of the zero-sequence current of the feeder to that of the neutral branch.Nonetheless,both zero-sequence voltage and zero-sequence current are affected by the transition resistance,The influence of transition resistance can be eliminated by calculating this coefficient.Therefore,a method based on the zero-sequence current ratio coefficient was proposed considering the significant difference between the faulty feeder and healthy feeder.Furthermore,unbalanced current can be prevented by setting the starting current.PSCAD simulation results reveal that the proposed method shows high reliability and sensitivity when a high-resistance grounding fault occurs. 展开更多
关键词 Low-resistance grounding system High-impedance grounding fault Grounding protection zero-sequence current ratio coefficient
下载PDF
NEW PRINCIPLE FOR DIRECTIONAL COMPARISON CARRIER PROTECTION OF EHV TRANSMISSION LINES 被引量:1
3
作者 王钢 李遥 +2 位作者 余晓丹 刘众仆 贺家李 《Transactions of Tianjin University》 EI CAS 1998年第2期6-10,共5页
The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave ch... The increasing scale and complexity of power systems require high performance and high reliability of power system protection.Protective relaying based on directional comparison with power line carrier or microwave channels is the most suitable protection scheme for long distance EHV transmission lines and is widely used in power systems.The key element of such protection is a directional relay used to discriminate the fault direction.In order to overcome the disadvantages of conventional directional relays,the authors of this paper put forward the directional comparison carrier protection based on the artificial neural network(ANN).The protection is extensively tested using electromagnetic transient program (EMTP) under various electric power system operating and fault conditions.It is proved that the directional comparison carrier protection based on ANN,which can recognize various fault patterns of the protected transmission line(such as fault direction,fault phases etc.)correctly in any kind of operating and fault conditions and the whole process,is satisfactory for EHV transmission line protection. 展开更多
关键词 artificial neural network EHV transmission line directional comparison carrier protection
下载PDF
Research on Evaluating Index of Lightning Protection Safety Performance of High Voltage Overhead Transmission Line 被引量:4
4
作者 Yi Luo Jingzhou Jiang +1 位作者 Yu Nong Shizuo Li 《Journal of Power and Energy Engineering》 2014年第4期680-686,共7页
In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. ... In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines. 展开更多
关键词 Transmission lineS LIGHTNING protection Safety Performance EVALUATING INDEX RATIO of LIGHTNING TRIPPING Operation
下载PDF
Analysis on the Relationship between Ecological Protection Red Line and Red Lines of Other Elements
5
作者 Liu Jialin Wang Xiaojun 《Meteorological and Environmental Research》 CAS 2019年第5期66-69,73,共5页
Ecological protection red line is the minimum spatial area and territorial boundary line to be protected to realize the unification of economic,social and ecological benefits by increasing the national and regional ec... Ecological protection red line is the minimum spatial area and territorial boundary line to be protected to realize the unification of economic,social and ecological benefits by increasing the national and regional ecological capital stock,maintaining ecological security,improving people's livelihood,promoting the sustainable development of economy and society,and upgrading the function of natural ecosystem.There are connections and differences between ecological protection red line and the red lines of cultivated land,forestry ecology,water resources control and marine ecology.Essentially speaking,they are all to maintain national ecological security and social stability,and create a good living environment for the people. 展开更多
关键词 ECOLOGICAL protection RED line CULTIVATED land RED line Marine ECOLOGY RED line
下载PDF
Research on Lightning Protection of Overhead Power Distribution Lines 被引量:2
6
作者 Shigeru Yokoyama Tomoyuki Sato 《高电压技术》 EI CAS CSCD 北大核心 2013年第10期2317-2328,共12页
There are two major protective methods against lightning outages on overhead distribution lines.One is a surge arrester,and the other is an overhead ground wire.The surge arresters have rather constant effect regardle... There are two major protective methods against lightning outages on overhead distribution lines.One is a surge arrester,and the other is an overhead ground wire.The surge arresters have rather constant effect regardless of the cause of the lightning outage.On the other hand,the effect of an overhead ground wire is quite different in two major causes,the direct lightning hit and the induced overvoltage.It is sufficient to provide surge arresters with an interval of 300 m for protection against the induced overvoltage caused by the nearby lightning stroke.Use of an overhead ground wire together with surge arresters is effective for lightning protection against the direct lightning hit to a distribution line.Puncture of surge arresters is the popular outage when the outage caused by the insulation break decreases sufficiently.Also,the existence of nearby trees leads to the line break due to the side flash from a tree.Advanced lightning protection equipment with ZnO arrester components is popular in Japan.Modeling of a pole transformer and application of an electromagnetic analysis method,such as FDTD method,to surge phenomena is considerably advanced. 展开更多
关键词 架空配电线路 防雷保护 雷击感应过电压 时域有限差分方法 架空地线 避雷器 防护方法 直接雷击
下载PDF
Digital simulation studies on long transmission line protection based on balance of energy
7
作者 文明浩 陈德树 尹项根 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2001年第4期409-411,共3页
The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods... The protection based balance of energy is a new technique specially proposed for long transmission lines. This technique depends upon the calculation of net energy into the transmission line by two independent methods and comparing them to indicate healthy and faulty conditions. In order to study the performance and feasibility of the protection based on balance of energy, the new protection has been extensively tested by using EMTP on a long transmission line with various configurations and operating conditions (including single pole line, double circuit lines and two phase operation). The results calculated by EMTP show that under any condition of a power system, the proposed technique has excellent performance,the viability even for high resistance ground faults and a short operation time. 展开更多
关键词 balance of energy long UHV transmission line transmission line protection digital simulation
下载PDF
A Novel Pilot Protection for VSC-HVDC Transmission Lines Based on Correlation Analysis
8
作者 Xingfu Jin Guobing Song 《Energy and Power Engineering》 2013年第4期1182-1186,共5页
The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVD... The control system of voltage source converter HVDC (VSC-HVDC) is complex and its fault tolerance ability is not sufficient, and correct rate of line protection device is not high. A novel pilot protection for VSC-HVDC transmission lines based on correlation analysis is proposed in this paper. In the principle, external fault is equivalent to a positive capacitance model, so the correlation coefficient of the current and voltage derivative is 1;while the internal fault is equivalent to a negative capacitance model, so the correlation coefficient of the current and voltage derivative is -1. Internal faults and external faults can be distinguished by judging the correlation coefficient. Theoretical analysis and PSCAD simulation experiments show that the new principle, which is simple, not affected by transition resistance, control type and line distributed capacitance current, can identify internal faults and external faults reliably and rapidly, having certain practical value. 展开更多
关键词 VSC-HVDC DC Transmission lineS CORRELATION COEFFICIENT PILOT protection
下载PDF
Impact Analyses of Wind Farm on Performances of Transmission Line Relay Protection 被引量:3
9
作者 Wang, Jin Zhang, Baohui 《电力系统自动化》 EI CSCD 北大核心 2012年第8期148-153,共6页
A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),w... A simulation system for power grid with concentrated large-scale wind farm integration is established based on the electro-magnetic transient model of wind turbine equipped with doubly-fed induction generator (DFIG),which is built by real-time digital simulator (RTDS).Using the hardware communication interface of RTDS,a closed-loop testing experiment is accomplished to study the impacts of large-scale wind farms on the existing relay protection devices for wind farm outgoing transmission line.This paper points out problems existing in current relay protection devices as follows:fault phase selector can select unwanted phase due to the changes of fault features caused by special network connection of wind farms;blocking condition for distance protections needs to be re-examined due to the weak power-feed characteristics of wind farms;and power frequency parameter based relay protection devices cannot accurately operate due to the special transient voltage and current characteristics of wind farms during fault period.Results lay the foundation for improving the performances of the existing relay protection device and developing new principle relay protection. 展开更多
关键词 继电保护装置 大型风电场 保护性能 输电线路 双馈风力发电机 双馈感应发电机 实时数字仿真 线路保护装置
下载PDF
Transmission Lines Distance Protection Using Differential Equation Algorithm and Hilbert-Huang Transform
10
作者 Xingmao Liu Zhengyou He 《Journal of Power and Energy Engineering》 2014年第4期616-623,共8页
This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various fa... This paper proposed the scheme of transmission lines distance protection based on differential equation algorithms (DEA) and Hilbert-Huang transform (HHT). The measured impedance based on EDA is affected by various factors, such as the distributed capacitance, the transient response characteristics of current transformer and voltage transformer, etc. In order to overcome this problem, the proposed scheme applies HHT to improve the apparent impedance estimated by DEA. Empirical mode decomposition (EMD) is used to decompose the data set from DEA into the intrinsic mode functions (IMF) and the residue. This residue has monotonic trend and is used to evaluate the impedance of faulty line. Simulation results show that the proposed scheme improves significantly the accuracy of the estimated impedance. 展开更多
关键词 Hilbert-Huang TRANSFORM DIFFERENTIAL EQUATION Algorithm DISTANCE protection Transmission lineS
下载PDF
Game Analysis and Mechanism Design of Ecological Protection Red Line for Ecologically Vulnerable Areas in Western China
11
作者 LIU Jialin ZHU Qiang 《Journal of Landscape Research》 2018年第5期73-78,共6页
Drawing the ecological protection red line is to maintain the integrity and benign operation of the ecosystem within the area,and to ensure that the ecological environment is within the boundary of controllable ecolog... Drawing the ecological protection red line is to maintain the integrity and benign operation of the ecosystem within the area,and to ensure that the ecological environment is within the boundary of controllable ecological security.Taking the ecologically vulnerable areas in western China as the research object and using the game theory and literature analysis,this paper studied the game behavior of ecological protection red line in these areas.In addition,this paper also analyzed the stakeholders such as government,enterprises and the masses in the drawing of the ecological protection red line,and comprehensively analyzed the game strategies between the government and the masses,the government and enterprises,and the central and local governments and enterprises.On the basis of the analysis,it came up with a safeguard mechanism for the coordination of the interests of the ecological protection red line. 展开更多
关键词 Ecological y vulnerable areas Ecological protection red line GAME MECHANISM
下载PDF
Study on the Delineation of Ecological Protection Red Line in Ecological Fragile Region of the West
12
作者 Liu Jialin 《Meteorological and Environmental Research》 CAS 2018年第4期19-23,29,共6页
Ecological protection red line is one of the main contents in system construction of ecological civilization in China, and also reflects the trend and the will of the national eco-environment protection system refor... Ecological protection red line is one of the main contents in system construction of ecological civilization in China, and also reflects the trend and the will of the national eco-environment protection system reform. In this paper, taking ecological fragile area of the west as the research object, and using literature analysis, comparative analysis and other methods, the characteristics in ecological fragile area of the west are compre-hensively elaborated, and the relationship between ecological vulnerability and ecological protection red line is clarified, and the delineation theory and methods of ecological protection red line are analyzed, such as ecological suitability analysis, regional ecological security pattern and DPSIR model. Finally, key issues of ecological protection red line delineation in ecological fragile zone of the west are proposed. 展开更多
关键词 Ecological fragile region Ecological protection red line MECHANISM WEST
下载PDF
Impact of Sensor Technology for Line Protection Performance
13
作者 Jianping Wang Murari Saha Torbjom Enairsson 《Journal of Energy and Power Engineering》 2014年第4期716-723,共8页
The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structu... The paper has presented the impact on the line protection performance with the introduction of MUs (merging units) in the process bus level. The paper begins with the introduction on modem digital substation structure and process bus. Then, the paper describes the performances of different sensors such as CTs (current transformers), CVTs (capacitive voltage transformers), FOCS (fiber optical current transducers) and FOVS (fiber optical voltage transducers). With the use of above transducers together with MUs, the performance of distance protection function and line differential protection function have been investigated and presented. Finally, conclusions based on the study are presented in the paper. 展开更多
关键词 Distance protection line differential protection current transformer voltage transformer digital substation non-conventional transformer.
下载PDF
Line Differential Protection Scheme Modelling for Underground 420 kV Cable Systems
14
作者 Michal Sztykiel Claus Leth Bak Sebastian Dollerup 《Journal of Energy and Power Engineering》 2012年第5期799-808,共10页
Based on the analysis of a specific relay model and an HVAC (high voltage alternating current) cable system, a detailed approach to EMTDC/PSCAD modelling of protective relays is presented. Such approach allows to cr... Based on the analysis of a specific relay model and an HVAC (high voltage alternating current) cable system, a detailed approach to EMTDC/PSCAD modelling of protective relays is presented. Such approach allows to create complex and accurate relay models derived from the original algorithms. Relay models can be applied with various systems, allowing to obtain the most optimal configuration of the protective relaying. The present paper describes modelling methodology on the basis of Siemens SIPROTEC 4 7SD522/610. Relay model was verified experimentally with its real equivalent by both EMTP-simulated and real world generated current signals connected to the relay. 展开更多
关键词 line differential protection XLPE HVAC cable EMTDC/PSCAD relay model SIPROTEC 4 7SD522 7SD610.
下载PDF
Influences of 500 kV Transmission Lines on Wetland Ecosystem and Its Protective Countermeasures--A Case Study of the Lake Wetland Natural Reserve along the Yangtze River in Anqing City
15
作者 Xia Shangguang Zhao Yuan 《Meteorological and Environmental Research》 CAS 2016年第4期17-22,共6页
The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric fiel... The impact of 500 kV transmission lines of Anqing power plant across the lake wetland reserve along the Yangtze River on the safety of the ecosystem was taken as the researched object.The power frequency electric field intensity(PFEFI),power frequency magnetic field intensity(PFMFI),radio interference,construction noise,vegetation destruction and the influence on water quality were investigated and monitored,and the influences of PFEFI,PFMFI,radio interference and construction noise on wild animals,especially the habitats and migration of birds were mainly researched.The direct and indirect influences on the surrounding environment as well as plants and animals in sensitive areas were analyzed and predicted.The results firstly showed there existed a 182 400m^3 stereo-space(PFEFI>4kV/m)which made flying birds unsafe under the lowest height 11 mof the lines,which fills the gap in the research of this field.Finally,some operational protection countermeasures were put forward at the current technical level to achieve the win-win goal of economic development and natural protection. 展开更多
关键词 Ultra-high-voltage transmission line Electromagnetic pollution LAKE WETLAND ECOSYSTEM safety protective measures China
下载PDF
Identification of Lightning Stroke and Fault in the Travelling Wave Protection
16
作者 Guibin Zou Houlei Gao +1 位作者 Wenbo Su Dapeng Wang 《Journal of Electromagnetic Analysis and Applications》 2009年第1期31-35,共5页
To resolve the impact of transient high frequency signals induced by lightning stroke on the travelling wave protection of transmission line, a novel identification algorithm is proposed. Using the characteristics of ... To resolve the impact of transient high frequency signals induced by lightning stroke on the travelling wave protection of transmission line, a novel identification algorithm is proposed. Using the characteristics of symmetric current wave-form induced by lightning stroke without causing fault and that of asymmetric current waveform generated by fault within a very short time interval, the waveform of transient current above and below time-axes are integrated respec-tively. First, through comparing the relative ratio of them with threshold value, the primary criterion identifying fault and lightning stroke is constructed;Secondly, to improve the reliability of discrimination between lightning stroke with and without causing fault, according to the difference of them, the secondary criterion is also defined. The simulation results and analysis demonstrate that the proposed integral criterions are valid and correct. 展开更多
关键词 Transmission line TRAVELLING Wave Based protection LIGHTNING STROKE CHARACTERISTIC of WAVEFORM Cri-terion
下载PDF
Research on 3D Modeling and Visualization of Coal Pillars for Surface Protection
17
作者 LIU Ya-jing MAO Shan-jun +1 位作者 YAO Ji-ming JIANG Yun-feng 《Journal of China University of Mining and Technology》 EI 2006年第3期254-257,共4页
In order to safely exploit coal resource, protection coal pillars must be prepared in coal mines. Some correlative parameters of protection coal pillar are calculated by Drop face and Drop line methods. Models of prot... In order to safely exploit coal resource, protection coal pillars must be prepared in coal mines. Some correlative parameters of protection coal pillar are calculated by Drop face and Drop line methods. Models of protecting surface objects and coal pillars are established by TIN modeling and object-oriented technique. By using ACCESS2000as the database and the VC++ and OpenGL as the language, the calculation of protective coal pillars is realized and the 3D-visulizaiton system for protected objects on ground surface and for coal pillars is developed. The system can obtain the data of characteristic points on the surface interactively from the digitized mine topography map, constructing 3D model automatically. It can also obtain the interrelated parameters of the coal seam and drill hole data from existing geolog!cal surveying database to calculate the location, surface area and the total coal columns. The whole process can be computed quickly and accurately. And the 3D visualization system was applied in a mine, showing that the system solve the problem of complex calculation, not only realized the automatic 3D mapping and visualization of coal pillars for buildings protection, but also greatly improves the working efficiency. 展开更多
关键词 protection coal pillar drop face drop line 3D visualization object-oriented modeling
下载PDF
Coastal Protection Forest Construction Project
18
《China's Foreign Trade》 1995年第9期18-18,共1页
China’s coastal line starts at the Yalu River in Liaoning in the north and ends at the Beilun River mouth in Guangxi. It is 18,000 kilometres long and crosses 11 provinces, municipalities and autonomous regions, incl... China’s coastal line starts at the Yalu River in Liaoning in the north and ends at the Beilun River mouth in Guangxi. It is 18,000 kilometres long and crosses 11 provinces, municipalities and autonomous regions, including Liaoning, Hebei, Tianjin, Shandong, Jiangsu, Shanghai, Zhejiang, Fujian, Guangdong, Guangxi and Hainan. In 1988, the Chinese government outlined the Coastal Protection Forest System Construction Project and defined the coastal line of 11 provinces as the main construction line. The project aims at developing a 展开更多
关键词 Coastal protection Forest Construction Project line
下载PDF
Applying Modern Communication Technology to Loss-of-Mains Protection
19
作者 Kimmo Kauhaniemi Olli Rintamaki 《Journal of Energy and Power Engineering》 2012年第3期429-433,共5页
The protection of distribution networks is facing new challenges from an increasing amount of DG (distributed generation). Even though current technology provides satisfactory solutions to manage this new situation,... The protection of distribution networks is facing new challenges from an increasing amount of DG (distributed generation). Even though current technology provides satisfactory solutions to manage this new situation, LOM (loss-of-mains protection) is still considered problematic. The solution proposed in this paper focuses on the use of a line differential protection relay. It inherently contains a suitable communication channel and provides absolutely selective protection for the feeder. Furthermore, it prevents the feeder relays from false tripping for faults on the neighboring feeder. The present trend in protection communication points towards the use of fiber optics. For line differential protection, this means a fast and high-capacity communication link which enables the implementation of many advanced protection functions. In addition, a solid foundation for such a communication link is offered by the new IEC 61850 standard and Ethernet technologies. The basic functionality of the line differential protection enables the operation of both the feeder protection and the DG protection for any fault on the feeder. Furthermore, basic LOM protection methods can be applied as backup protection for failures on the communication link. 展开更多
关键词 LOM protection communication line differential protection IEC 61850 GOOSE.
下载PDF
Seal&protect^(TM)作为洞衬剂的扫描电镜研究
20
作者 张青松 邢晓艳 +1 位作者 沈军 王正坤 《现代口腔医学杂志》 CAS CSCD 北大核心 2006年第2期179-180,共2页
目的通过扫描电镜观察Seal&protectTM与洞壁密合情况。方法选正畸需拔除的活髓牙,口腔内备洞,涂布此药后制备标本,扫描电镜观察其与牙釉质、牙本质密合情况。结果釉质组:药物与洞壁结合紧密。牙本质组:药物与洞壁结合紧密,完全封闭... 目的通过扫描电镜观察Seal&protectTM与洞壁密合情况。方法选正畸需拔除的活髓牙,口腔内备洞,涂布此药后制备标本,扫描电镜观察其与牙釉质、牙本质密合情况。结果釉质组:药物与洞壁结合紧密。牙本质组:药物与洞壁结合紧密,完全封闭牙本质小管口,并能渗入小管达一定深度。结论Seal&protectTM能与牙釉质、牙本质洞壁完全密合,能渗入小管,是良好的洞衬剂。 展开更多
关键词 Seal&protect^TM 脱敏剂 洞衬剂 扫描电镜
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部