Based on one-dimensional water quality model and nonlinear programming, the point source pollution reduction model with multi-objective optimization has been established. To achieve cost effective and best water quali...Based on one-dimensional water quality model and nonlinear programming, the point source pollution reduction model with multi-objective optimization has been established. To achieve cost effective and best water quality, for us to optimize the process, we set pollutant concentration and total amount control as constraints and put forward the optimal pollution reduction control strategy by simulating and optimizing water quality monitoring data from the target section. Integrated with scenario analysis, COD and ammonia nitrogen pollution optimization wasstudiedin objective function area from Mountain Maan of Acheng to Fuerjia Bridge along Ashe River. The results showed that COD and NH3-N contribution has been greatly reduced to AsheRiverby 49.6% and 32.7% respectively. Therefore, multi-objective optimization by nonlinear programming for water pollution control can make source sewage optimization fairly and reasonably, and the optimal strategies of pollution emission are presented.展开更多
A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power system...A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.展开更多
Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe w...Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe way to control biological contamination was to limit relative humidity in HVAC system and conditioned environment in the range that is more unsuitable for microorganism to survive. In this paper,by referring to bio-clean project experiences,a system-based humidity priority control manner came into being by lowering outdoor air humidity ratio to eliminate all indoor latent load and using self recirculation units to bear indoor sensible load. Based on the whole-course residue humidity contaminant control concept,dynamic step models for coil and conditioned zone were developed to describe mass and energy conservation and transformation processes. Then,HVAC system and conditioned zone dynamic models were established on LabVIEW+Matlab platform to investigate optimized regulation types,input signatures and control logics. Decoupling between cooling and dehumidification processes can be achieved and a more simplified and stable control system can be acquired by the system-based humidity priority control strategy. Therefore,it was a promising way for controlling biological pollution in buildings in order to achieve better IAQ.展开更多
The aim of this work is mathematical education through the knowledge system and mathematical modeling. A net model of formation of mathematical knowledge as a deductive theory is suggested here. Within this model the ...The aim of this work is mathematical education through the knowledge system and mathematical modeling. A net model of formation of mathematical knowledge as a deductive theory is suggested here. Within this model the formation of deductive theory is represented as the development of a certain informational space, the elements of which are structured in the form of the orientated semantic net. This net is properly metrized and characterized by a certain system of coverings. It allows injecting net optimization parameters, regulating qualitative aspects of knowledge system under consideration. To regulate the creative processes of the formation and realization of mathematical know- edge, stochastic model of formation deductive theory is suggested here in the form of branching Markovian process, which is realized in the corresponding informational space as a semantic net. According to this stochastic model we can get correct foundation of criterion of optimization creative processes that leads to “great main points” strategy (GMP-strategy) in the process of realization of the effective control in the research work in the sphere of mathematics and its applications.展开更多
This paper presents a closed-loop vector control structure based on adaptive Fuzzy Logic Sliding Mode Controller (FL-SMC) for a grid-connected Wave Energy Conversion System (WECS) driven Self-Excited Induction Generat...This paper presents a closed-loop vector control structure based on adaptive Fuzzy Logic Sliding Mode Controller (FL-SMC) for a grid-connected Wave Energy Conversion System (WECS) driven Self-Excited Induction Generator (SEIG). The aim of the developed control method is to automatically tune and optimize the scaling factors and the membership functions of the Fuzzy Logic Controllers (FLC) using Multi-Objective Genetic Algorithms (MOGA) and Multi-Objective Particle Swarm Optimization (MOPSO). Two Pulse Width Modulated voltage source PWM converters with a carrier-based Sinusoidal PWM modulation for both Generator- and Grid-side converters have been connected back to back between the generator terminals and utility grid via common DC link. The indirect vector control scheme is implemented to maintain balance between generated power and power supplied to the grid and maintain the terminal voltage of the generator and the DC bus voltage constant for variable rotor speed and load. Simulation study has been carried out using the MATLAB/Simulink environment to verify the robustness of the power electronics converters and the effectiveness of proposed control method under steady state and transient conditions and also machine parameters mismatches. The proposed control scheme has improved the voltage regulation and the transient performance of the wave energy scheme over a wide range of operating conditions.展开更多
Introduction: The Indian state of Uttar Pradesh (UP) for the past many years has been reported to have many cities with highly polluted air quality. The state has been taking meticulous steps in combating air pollutio...Introduction: The Indian state of Uttar Pradesh (UP) for the past many years has been reported to have many cities with highly polluted air quality. The state has been taking meticulous steps in combating air pollution in the form of action plans, introduced especially in its 17 non-attainment cities (NAC). To assess the progress and development of these action plans in UP, the present study has done an in-depth analysis and review of the state’s action plans and city micro action plans. Materials and Methods: In this research study, the analysis of the latest action plan reports, micro action plan reports as well as the recommendations for combating air pollution-related issues in the 17 NAC of the UP state has been well documented. Uttar Pradesh Pollution Control Board (UPPCB) has prepared these reports to highlight the progress of the plans in response to the growing air pollution in these cities. The information present in the reports has been used to further study sector-specific, category-specific action plans, institutional responsibility, and the present status of the action plans. Results: On average, the highest weightage in action plans was given to sector-specific categories such as Road dust and construction activities (24%). It was also observed that Urban local bodies (~50%) were majorly responsible to implement the action points and 56% of the action points were jointly implemented by multiple agencies.展开更多
In this research,a methodology named whole-process pollution control(WPPC)is demonstrated that improves the effectiveness of process optimization.This methodology considers waste/emission treatment as a step of the wh...In this research,a methodology named whole-process pollution control(WPPC)is demonstrated that improves the effectiveness of process optimization.This methodology considers waste/emission treatment as a step of the whole production process with respect to the minimization of cost and environmental impact for the whole process.The following procedures are introduced in a WPPC process optimization:①a material and energy flow investigation and optimization based on a systematic understanding of the distribution and physiochemical properties of potential pollutants;②a process optimization to increase the utilization efficiency of different elements and minimize pollutant emissions;and③an evaluation to reveal the effectiveness of the optimization strategies.The production of ammonium paratungstate was chosen for the case study.Two factors of the different optimization schemes-namely the cost-effectiveness factor and the environmental impact indicator-were evaluated and compared.This research demonstrates that by considering the nature of potential pollutants,technological innovations,economic viability,environmental impacts,and regulation requirements,WPPC can efficiently optimize a metal production process.展开更多
As China strives towards the second centenary goal,increasing attention is being paid to environmental pollution and other related issues.Concurrently,with the rapid development of big data technology,many big data so...As China strives towards the second centenary goal,increasing attention is being paid to environmental pollution and other related issues.Concurrently,with the rapid development of big data technology,many big data solutions have been applied to environmental pollution control audits,exerting a significant impact.This paper presents the current situation of environmental pollution audits,summarizing the application of big data from the perspectives of both domestic and international research.In terms of data collection and data analysis for environmental pollution audits,cloud platform technology,and visualization technology are selected based on multiple data sources.The impact in the field of environmental pollution control audits is further analyzed.It is found that the environmental pollution audit cloud platform is not yet perfect,the technical skills of audit personnel are insufficient,and some technologies are not mature.Relevant suggestions are put forward to provide a reference for the future development of big data technology and its integration with environmental pollution control audits.展开更多
This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmen...This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmental burden caused by the discharge of untreated sludge. Sludge sample was cultured in other to isolate microorganisms for the sludge treatment. The selected strain of the organisms after screening were Aspergillus flavus, Aspergillus niger, Verticillus sp, Penicillum sp, and Microsporium audouinii. Bioreactors (labeled A, B, C, D and O) were designed for the treatment of petroleum sludge. These reactors contain 2.0 × 10<sup>-2</sup> m<sup>3</sup> of the diluted sludge samples and the isolated organisms for the treatment process. On a weekly basis, the control reactors received 1.5 × 10<sup>-3</sup> m<sup>3</sup> of fresh and saline water respectively. After 12 weeks of treatment, sludge physicochemical characteristics showed distinct variations. From the result, reactor D was the best in terms of remediating the sludge as compared to other reactors. Friedman non-parametric test was performed to check if the weeks of treatment affected the reduction of the total hydrocarbon content (THC) in the five reactors and also checked for significant differences in the THC after treatments. The drop in the THC of the treated sludge ranged from 56.0% to 67.3%. These results showed the possibility of enhanced biodegradation of petroleum sludge by hydrocarbon utilizing microorganisms (fungi).展开更多
Typically, active control systems either have a priori complete information about the boundary-value problem and damped waves before switching on, or get it during the measurement process or accumulate and update info...Typically, active control systems either have a priori complete information about the boundary-value problem and damped waves before switching on, or get it during the measurement process or accumulate and update information online (identification process in adaptive systems). In this case, the boundary problem is completely imprinted in the information arrays of the control system. However, very often complete information about a boundary-value problem is not available in principle or this info is changing in time faster than the process of its accumulation. The article considers examples of boundary control algorithms based almost without any information. The algorithms presented in the article cannot be obtained within the framework of the harmonic representation of the problem by complex amplitudes. And these algorithms carry out fast control in microstructured boundary problems. It is shown that in some cases it is possible to find simple solutions if we remove restrictions: 1) on the spatio-temporal resolution of controlling elements of a boundary-value problem;2) on the high-frequency radiation of the controlled boundary.展开更多
It is well known that balance control is affected by aging, neurological and orthopedic conditions. Poor balance control during gait and postural maintenance are associated with disability, falls and increased mortali...It is well known that balance control is affected by aging, neurological and orthopedic conditions. Poor balance control during gait and postural maintenance are associated with disability, falls and increased mortality. Gait initiation-the transient period between the quiet standing posture and steady state walking-is a functional task that is classically used in the literature to investigate how the central nervous system(CNS) controls balance during a whole-body movement involving change in the base of support dimensions and center of mass progression. Understanding how the CNS in able-bodied subjects exerts this control during such a challenging task is a prerequisite to identifying motor disorders in populations with specific impairments of the postural system. It may also provide clinicians with objective measures to assess the efficiency of rehabilitation programs and better target interventions according to individual impairments. The present review thus proposes a state-of-the-art analysis on:(1) the balance control mechanisms in play during gait initiation in able bodied subjects and in the case of some frail populations; and(2) the biomechanical parameters used in the literature to quantify dynamic stability during gait initiation. Balance control mechanisms reviewed in this article included anticipatory postural adjustments, stance leg stiffness, foot placement, lateral ankle strategy, swing foot strike pattern and vertical center of mass braking. Based on this review, the following viewpoints were put forward:(1) dynamic stability during gait initiation may share a principle of homeostatic regulation similar to most physiological variables, where separate mechanisms need to be coordinated to ensure stabilization of vital variables, and consequently; and(2) rehabilitation interventions which focus on separate or isolated components of posture, balance, or gait may limit the effectiveness of current clinical practices.展开更多
The Bohai Sea(BS)is the unique semi-closed inland sea of China,characterized by degraded water quality due to significant terrestrial pollution input.In order to improve its water quality,a dedicated action named“Uph...The Bohai Sea(BS)is the unique semi-closed inland sea of China,characterized by degraded water quality due to significant terrestrial pollution input.In order to improve its water quality,a dedicated action named“Uphill Battles for Integrated Bohai Sea Management”(UBIBSM,2018–2020)was implemented by the Chinese government.To evaluate the action effectiveness toward water quality improvement,variability of the satelliteobserved water transparency(Secchi disk depth,Z_(SD))was explored,with special emphasis on the nearshore waters(within 20 km from the coastline)prone to terrestrial influence.(1)Compared to the status before the action began(2011–2017),majority(87.3%)of the nearshore waters turned clear during the action implementation period(2018–2020),characterized by the elevated Z_(SD)by 11.6%±12.1%.(2)Nevertheless,the improvement was not spatially uniform,with higher Z_(SD)improvement in provinces of Hebei,Liaoning,and Shandong(13.2%±16.5%,13.2%±11.6%,10.8%±10.2%,respectively)followed by Tianjin(6.2%±4.7%).(3)Bayesian trend analysis found the abrupt Z_(SD)improvement in April 2018,which coincided with the initiation of UBIBSM,implying the water quality response to pollution control.More importantly,the independent statistics of land-based pollutant discharge also indicated that the significant reduction of terrestrial pollutant input during the UBIBSM action was the main driver of observed Z_(SD)improvement.(4)Compared with previous pollution control actions in the BS,UBIBSM was found to be the most successful one during the past 20 years,in terms of transparency improvement over nearshore waters.The presented results proved the UBIBSM-achieved remarkable water quality improvement,taking the advantage of long-term consistent and objective data record from satellite ocean color observation.展开更多
Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug deliv...Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug delivery often results in a burst release of the drug,leading to transient retention(inefficacy)and undesirable diffusion(toxicity)in vivo.Therefore,a drug delivery system that responds to changes in the microenvironment of tissue regeneration and controls vascular endothelial growth factor release is crucial to improve the treatment of ischemic stroke.Matrix metalloproteinase-2(MMP-2)is gradually upregulated after cerebral ischemia.Herein,vascular endothelial growth factor mimic peptide QK was self-assembled with MMP-2-cleaved peptide PLGLAG(TIMP)and customizable peptide amphiphilic(PA)molecules to construct nanofiber hydrogel PA-TIMP-QK.PA-TIMP-QK was found to control the delivery of QK by MMP-2 upregulation after cerebral ischemia/reperfusion and had a similar biological activity with vascular endothelial growth factor in vitro.The results indicated that PA-TIMP-QK promoted neuronal survival,restored local blood circulation,reduced blood-brain barrier permeability,and restored motor function.These findings suggest that the self-assembling nanofiber hydrogel PA-TIMP-QK may provide an intelligent drug delivery system that responds to the microenvironment and promotes regeneration and repair after cerebral ischemia/reperfusion injury.展开更多
Presented in this manuscript are conventional electrical engineering tools to model the earth as a rotating electrical machine. Calculations using known parameters of the earth and measured field data has resulted in ...Presented in this manuscript are conventional electrical engineering tools to model the earth as a rotating electrical machine. Calculations using known parameters of the earth and measured field data has resulted in new understanding of the earth’s electrical system and gyroscopic rotation. The material makeup of the inner earth is better understood based on derived permeability and permittivity constants. The planet has been modeled as simple coils and then as a parallel impedance circuit which has led to fundamental insight into planetary speed control and RLC combination for Schumann Resonance of 7.83 Hz. Torque and Voltage Constants and the inverse Speed Constant are calculated using three methods and all compare favorably with Newton’s Gravitational Constant. A helical resonator is referenced and Schumann’s Resonant ideal frequency is calculated and compared with others idealism. A new theory of gravity based on particle velocity selector at the poles is postulated. Two equations are presented as the needed links between Faraday’s electromagnetism and Newtonian physics. Acceleration and Deceleration of earth is explained as a centripetal governor. A new equation for planetary attraction and the attraction of atomic matter is theorized. Rotation of the earth’s electrical coil is explained in terms of the Richardson effect. Electric power transfer from the sun to the planets is proposed via Flux Transfer Events. The impact of this evolving science of electromagnetic modeling of planets will be magnified as the theory is proven, and found to be useful for future generations of engineers and scientists who seek to discover our world and other planets.展开更多
To improve ambient air quality and return citizens blue sky and white clouds,national and local administrative departments all issue corresponding countermeasures to strictly prevent and control air pollution,reduce t...To improve ambient air quality and return citizens blue sky and white clouds,national and local administrative departments all issue corresponding countermeasures to strictly prevent and control air pollution,reduce total pollutant emission,and improve environmental management level. In this paper,taking Tianjin as an example,change situation of regional air pollution and its prevention and control management situation were summarized.展开更多
The input-output pollution control model given in [1] is generalized. The generalization makes it easier for the model to handle many problem instances. A linear program is used to solve the new model. An example is g...The input-output pollution control model given in [1] is generalized. The generalization makes it easier for the model to handle many problem instances. A linear program is used to solve the new model. An example is given to show that the new model can handle classes of problems that the original model cannot handle.展开更多
China’s past economic growth has substantially relied on fossil fuels,causing serious air pollution issues.Decoupling economic growth and pollution has become the focus in developing ecological civilization in China....China’s past economic growth has substantially relied on fossil fuels,causing serious air pollution issues.Decoupling economic growth and pollution has become the focus in developing ecological civilization in China.We have analyzed the three-decade progress of air pollution controls in China,highlighting a strategic transformation from emission control toward air quality management.Emission control of sulfur dioxide(SO2)resolved the deteriorating acid rain issue in China in 2007.Since 2013,control actions on multiple precursors and sectors have targeted the reduction of the concentration of fine particulate matter(PM2.5),marking a transition to an air-quality-oriented strategy.Increasing ozone(O3)pollution further requires O3 and PM2.5 integrated control strategies with an emphasis on their complex photochemical interactions.Fundamental improvement of air quality in China,as a key indicator for the success of ecological civilization construction,demands the deep de-carbonization of China’s energy system as well as more synergistic pathways to address air pollution and global climate change simultaneously.展开更多
Increasing attention has been paid to air pollution control (APC) residues in China recently due to the rising proportion of waste incineration and the hazardous characteristics of the residues, among which heavy me...Increasing attention has been paid to air pollution control (APC) residues in China recently due to the rising proportion of waste incineration and the hazardous characteristics of the residues, among which heavy metal leaching toxicity plays an important role. Leaching behavior and potential risk of Pb and Zn in the APC residues from a Shanghai municipal solid waste (MSW) incinerator was studied, based on the leaching tests under different conditions and theoretical calculation using a geochemical thermodynamic equilibrium model MINTEQA2. Results showed that, extractant species and liquid to solid (L/S) ratio predominantly controlled the leaching toxicity of Pb and Zn, while ionic strength, vibration method and leaching time had less effect on the metals release. Leachate/final pH determined the metal leaching behavior, which changed the speciation of heavy metals in the extraction system. The equilibrium aqueous speciation, precipitation-dissolution of Pb and Zn was investigated according to the model computation, which was well in agreement with the experimental results.展开更多
For the 2008 Olympic Games, drastic control measures were implemented on industrial and urban emissions of sulfur dioxide (SO2), nitrogen oxides (NOx) and other pollutants to address the issues of poor air quality...For the 2008 Olympic Games, drastic control measures were implemented on industrial and urban emissions of sulfur dioxide (SO2), nitrogen oxides (NOx) and other pollutants to address the issues of poor air quality in Beijing. To investigate the effects of SO2 and NOx reductions on the particulate sulfate and nitrate concentrations as well as their size distributions, size-segregated aerosol samples were collected using micro-orifice uniform deposit impactors (MOUDIs) at urban and downwind rural sites in Beijing before and after full-scale controls. During the sampling period, the mass concentrations of fine particles (PMI.s) at the urban and rural sites were 94.0 and 85.9 p.g m-3, respectively. More than 90% of the sulfates and 60% of nitrates formed as fine particles. Benefiting from the advantageous meteorological conditions and the source controls, sulfates were observed in rather low concentrations and primarily in condensation mode during the Olympics. The effects of the control measures were separately analyzed for the northerly and the southerly air-mass-dominated days to account for any bias. After the control measures were implemented, PM, sulfates, and nitrates were significantly reduced when the northerly air masses prevailed, with a higher percentage of reduction in larger particles. The droplet mode particles, which dominated the sulfates and nitrates before the controls were implemented, were remarkably reduced in mass concentration after the control measures were implemented. Nevertheless, when the polluted southerly air masses prevailed, the local source control measures in Beijing did not effectively reduce the ambient sulfate concentration due to the enormous regional contribution from the North China Plain.展开更多
文摘Based on one-dimensional water quality model and nonlinear programming, the point source pollution reduction model with multi-objective optimization has been established. To achieve cost effective and best water quality, for us to optimize the process, we set pollutant concentration and total amount control as constraints and put forward the optimal pollution reduction control strategy by simulating and optimizing water quality monitoring data from the target section. Integrated with scenario analysis, COD and ammonia nitrogen pollution optimization wasstudiedin objective function area from Mountain Maan of Acheng to Fuerjia Bridge along Ashe River. The results showed that COD and NH3-N contribution has been greatly reduced to AsheRiverby 49.6% and 32.7% respectively. Therefore, multi-objective optimization by nonlinear programming for water pollution control can make source sewage optimization fairly and reasonably, and the optimal strategies of pollution emission are presented.
文摘A big step forward to improve power system monitoring and performance, continued load growth without a corresponding increase in transmission resources has resulted in reduced operational margins for many power systems worldwide and has led to operation of power systems closer to their stability limits and to power exchange in new patterns. These issues, as well as the on-going worldwide trend towards deregulation of the entire industry on the one hand and the increased need for accurate and better network monitoring on the other hand, force power utilities exposed to this pressure to demand new solutions for wide area monitoring, protection and control. Wide-area monitoring, protection, and control require communicating the specific-node information to a remote station but all information should be time synchronized so that to neutralize the time difference between information. It gives a complete simultaneous snap shot of the power system. The conventional system is not able to satisfy the time-synchronized requirement of power system. Phasor Measurement Unit (PMU) is enabler of time-synchronized measurement, it communicate the synchronized local information to remote station.
基金Project(2006BAJ02A10) supported by the National Key Technologies R & D Program of China
文摘Indoor biological contamination and HVAC system secondary contamination problems caused wide public concerns. Biological contamination control will be the next step to achieve better IAQ. The most efficient and safe way to control biological contamination was to limit relative humidity in HVAC system and conditioned environment in the range that is more unsuitable for microorganism to survive. In this paper,by referring to bio-clean project experiences,a system-based humidity priority control manner came into being by lowering outdoor air humidity ratio to eliminate all indoor latent load and using self recirculation units to bear indoor sensible load. Based on the whole-course residue humidity contaminant control concept,dynamic step models for coil and conditioned zone were developed to describe mass and energy conservation and transformation processes. Then,HVAC system and conditioned zone dynamic models were established on LabVIEW+Matlab platform to investigate optimized regulation types,input signatures and control logics. Decoupling between cooling and dehumidification processes can be achieved and a more simplified and stable control system can be acquired by the system-based humidity priority control strategy. Therefore,it was a promising way for controlling biological pollution in buildings in order to achieve better IAQ.
文摘The aim of this work is mathematical education through the knowledge system and mathematical modeling. A net model of formation of mathematical knowledge as a deductive theory is suggested here. Within this model the formation of deductive theory is represented as the development of a certain informational space, the elements of which are structured in the form of the orientated semantic net. This net is properly metrized and characterized by a certain system of coverings. It allows injecting net optimization parameters, regulating qualitative aspects of knowledge system under consideration. To regulate the creative processes of the formation and realization of mathematical know- edge, stochastic model of formation deductive theory is suggested here in the form of branching Markovian process, which is realized in the corresponding informational space as a semantic net. According to this stochastic model we can get correct foundation of criterion of optimization creative processes that leads to “great main points” strategy (GMP-strategy) in the process of realization of the effective control in the research work in the sphere of mathematics and its applications.
文摘This paper presents a closed-loop vector control structure based on adaptive Fuzzy Logic Sliding Mode Controller (FL-SMC) for a grid-connected Wave Energy Conversion System (WECS) driven Self-Excited Induction Generator (SEIG). The aim of the developed control method is to automatically tune and optimize the scaling factors and the membership functions of the Fuzzy Logic Controllers (FLC) using Multi-Objective Genetic Algorithms (MOGA) and Multi-Objective Particle Swarm Optimization (MOPSO). Two Pulse Width Modulated voltage source PWM converters with a carrier-based Sinusoidal PWM modulation for both Generator- and Grid-side converters have been connected back to back between the generator terminals and utility grid via common DC link. The indirect vector control scheme is implemented to maintain balance between generated power and power supplied to the grid and maintain the terminal voltage of the generator and the DC bus voltage constant for variable rotor speed and load. Simulation study has been carried out using the MATLAB/Simulink environment to verify the robustness of the power electronics converters and the effectiveness of proposed control method under steady state and transient conditions and also machine parameters mismatches. The proposed control scheme has improved the voltage regulation and the transient performance of the wave energy scheme over a wide range of operating conditions.
文摘Introduction: The Indian state of Uttar Pradesh (UP) for the past many years has been reported to have many cities with highly polluted air quality. The state has been taking meticulous steps in combating air pollution in the form of action plans, introduced especially in its 17 non-attainment cities (NAC). To assess the progress and development of these action plans in UP, the present study has done an in-depth analysis and review of the state’s action plans and city micro action plans. Materials and Methods: In this research study, the analysis of the latest action plan reports, micro action plan reports as well as the recommendations for combating air pollution-related issues in the 17 NAC of the UP state has been well documented. Uttar Pradesh Pollution Control Board (UPPCB) has prepared these reports to highlight the progress of the plans in response to the growing air pollution in these cities. The information present in the reports has been used to further study sector-specific, category-specific action plans, institutional responsibility, and the present status of the action plans. Results: On average, the highest weightage in action plans was given to sector-specific categories such as Road dust and construction activities (24%). It was also observed that Urban local bodies (~50%) were majorly responsible to implement the action points and 56% of the action points were jointly implemented by multiple agencies.
基金The authors acknowledge financial support for this research from the National Key Research and Development Program of China(2017YFB0403300 and 2017YFB043305)the National Natural Science Foundation of China(51425405 and 51874269),the National Science-Technology Support Plan Projects(2015BAB02B05)the Youth Innovation Promotion Association of Chinese Academy of Sciences(2014037).Zhi Sun acknowledges financial support from the National Youth Thousand Talents Program.The authors acknowledge constructive suggestions from Prof.Jianxin Yang.
文摘In this research,a methodology named whole-process pollution control(WPPC)is demonstrated that improves the effectiveness of process optimization.This methodology considers waste/emission treatment as a step of the whole production process with respect to the minimization of cost and environmental impact for the whole process.The following procedures are introduced in a WPPC process optimization:①a material and energy flow investigation and optimization based on a systematic understanding of the distribution and physiochemical properties of potential pollutants;②a process optimization to increase the utilization efficiency of different elements and minimize pollutant emissions;and③an evaluation to reveal the effectiveness of the optimization strategies.The production of ammonium paratungstate was chosen for the case study.Two factors of the different optimization schemes-namely the cost-effectiveness factor and the environmental impact indicator-were evaluated and compared.This research demonstrates that by considering the nature of potential pollutants,technological innovations,economic viability,environmental impacts,and regulation requirements,WPPC can efficiently optimize a metal production process.
文摘As China strives towards the second centenary goal,increasing attention is being paid to environmental pollution and other related issues.Concurrently,with the rapid development of big data technology,many big data solutions have been applied to environmental pollution control audits,exerting a significant impact.This paper presents the current situation of environmental pollution audits,summarizing the application of big data from the perspectives of both domestic and international research.In terms of data collection and data analysis for environmental pollution audits,cloud platform technology,and visualization technology are selected based on multiple data sources.The impact in the field of environmental pollution control audits is further analyzed.It is found that the environmental pollution audit cloud platform is not yet perfect,the technical skills of audit personnel are insufficient,and some technologies are not mature.Relevant suggestions are put forward to provide a reference for the future development of big data technology and its integration with environmental pollution control audits.
文摘This study investigated the use of microbial analysis as a bioremediation option for remediating petroleum sludge, which is part of the waste stream generated in the petroleum industry. The aim is to reduce environmental burden caused by the discharge of untreated sludge. Sludge sample was cultured in other to isolate microorganisms for the sludge treatment. The selected strain of the organisms after screening were Aspergillus flavus, Aspergillus niger, Verticillus sp, Penicillum sp, and Microsporium audouinii. Bioreactors (labeled A, B, C, D and O) were designed for the treatment of petroleum sludge. These reactors contain 2.0 × 10<sup>-2</sup> m<sup>3</sup> of the diluted sludge samples and the isolated organisms for the treatment process. On a weekly basis, the control reactors received 1.5 × 10<sup>-3</sup> m<sup>3</sup> of fresh and saline water respectively. After 12 weeks of treatment, sludge physicochemical characteristics showed distinct variations. From the result, reactor D was the best in terms of remediating the sludge as compared to other reactors. Friedman non-parametric test was performed to check if the weeks of treatment affected the reduction of the total hydrocarbon content (THC) in the five reactors and also checked for significant differences in the THC after treatments. The drop in the THC of the treated sludge ranged from 56.0% to 67.3%. These results showed the possibility of enhanced biodegradation of petroleum sludge by hydrocarbon utilizing microorganisms (fungi).
文摘Typically, active control systems either have a priori complete information about the boundary-value problem and damped waves before switching on, or get it during the measurement process or accumulate and update information online (identification process in adaptive systems). In this case, the boundary problem is completely imprinted in the information arrays of the control system. However, very often complete information about a boundary-value problem is not available in principle or this info is changing in time faster than the process of its accumulation. The article considers examples of boundary control algorithms based almost without any information. The algorithms presented in the article cannot be obtained within the framework of the harmonic representation of the problem by complex amplitudes. And these algorithms carry out fast control in microstructured boundary problems. It is shown that in some cases it is possible to find simple solutions if we remove restrictions: 1) on the spatio-temporal resolution of controlling elements of a boundary-value problem;2) on the high-frequency radiation of the controlled boundary.
文摘It is well known that balance control is affected by aging, neurological and orthopedic conditions. Poor balance control during gait and postural maintenance are associated with disability, falls and increased mortality. Gait initiation-the transient period between the quiet standing posture and steady state walking-is a functional task that is classically used in the literature to investigate how the central nervous system(CNS) controls balance during a whole-body movement involving change in the base of support dimensions and center of mass progression. Understanding how the CNS in able-bodied subjects exerts this control during such a challenging task is a prerequisite to identifying motor disorders in populations with specific impairments of the postural system. It may also provide clinicians with objective measures to assess the efficiency of rehabilitation programs and better target interventions according to individual impairments. The present review thus proposes a state-of-the-art analysis on:(1) the balance control mechanisms in play during gait initiation in able bodied subjects and in the case of some frail populations; and(2) the biomechanical parameters used in the literature to quantify dynamic stability during gait initiation. Balance control mechanisms reviewed in this article included anticipatory postural adjustments, stance leg stiffness, foot placement, lateral ankle strategy, swing foot strike pattern and vertical center of mass braking. Based on this review, the following viewpoints were put forward:(1) dynamic stability during gait initiation may share a principle of homeostatic regulation similar to most physiological variables, where separate mechanisms need to be coordinated to ensure stabilization of vital variables, and consequently; and(2) rehabilitation interventions which focus on separate or isolated components of posture, balance, or gait may limit the effectiveness of current clinical practices.
基金The fund supported by Southern Marine Science and Engineering Guangdong Laboratory (Zhuhai) under contract No. SML2021SP313the fundamental research funds for the Central Universities of Sun Yat-Sen University under contract No.23xkjc019the fund supported by China-Korea Joint Ocean Research Center of China under contract No. PI-2022-1-01
文摘The Bohai Sea(BS)is the unique semi-closed inland sea of China,characterized by degraded water quality due to significant terrestrial pollution input.In order to improve its water quality,a dedicated action named“Uphill Battles for Integrated Bohai Sea Management”(UBIBSM,2018–2020)was implemented by the Chinese government.To evaluate the action effectiveness toward water quality improvement,variability of the satelliteobserved water transparency(Secchi disk depth,Z_(SD))was explored,with special emphasis on the nearshore waters(within 20 km from the coastline)prone to terrestrial influence.(1)Compared to the status before the action began(2011–2017),majority(87.3%)of the nearshore waters turned clear during the action implementation period(2018–2020),characterized by the elevated Z_(SD)by 11.6%±12.1%.(2)Nevertheless,the improvement was not spatially uniform,with higher Z_(SD)improvement in provinces of Hebei,Liaoning,and Shandong(13.2%±16.5%,13.2%±11.6%,10.8%±10.2%,respectively)followed by Tianjin(6.2%±4.7%).(3)Bayesian trend analysis found the abrupt Z_(SD)improvement in April 2018,which coincided with the initiation of UBIBSM,implying the water quality response to pollution control.More importantly,the independent statistics of land-based pollutant discharge also indicated that the significant reduction of terrestrial pollutant input during the UBIBSM action was the main driver of observed Z_(SD)improvement.(4)Compared with previous pollution control actions in the BS,UBIBSM was found to be the most successful one during the past 20 years,in terms of transparency improvement over nearshore waters.The presented results proved the UBIBSM-achieved remarkable water quality improvement,taking the advantage of long-term consistent and objective data record from satellite ocean color observation.
基金supported by the Natural Science Foundation of Shandong Province,No.ZR2023MC168the National Natural Science Foundation of China,No.31670989the Key R&D Program of Shandong Province,No.2019GSF107037(all to CS).
文摘Vascular endothelial growth factor and its mimic peptide KLTWQELYQLKYKGI(QK)are widely used as the most potent angiogenic factors for the treatment of multiple ischemic diseases.However,conventional topical drug delivery often results in a burst release of the drug,leading to transient retention(inefficacy)and undesirable diffusion(toxicity)in vivo.Therefore,a drug delivery system that responds to changes in the microenvironment of tissue regeneration and controls vascular endothelial growth factor release is crucial to improve the treatment of ischemic stroke.Matrix metalloproteinase-2(MMP-2)is gradually upregulated after cerebral ischemia.Herein,vascular endothelial growth factor mimic peptide QK was self-assembled with MMP-2-cleaved peptide PLGLAG(TIMP)and customizable peptide amphiphilic(PA)molecules to construct nanofiber hydrogel PA-TIMP-QK.PA-TIMP-QK was found to control the delivery of QK by MMP-2 upregulation after cerebral ischemia/reperfusion and had a similar biological activity with vascular endothelial growth factor in vitro.The results indicated that PA-TIMP-QK promoted neuronal survival,restored local blood circulation,reduced blood-brain barrier permeability,and restored motor function.These findings suggest that the self-assembling nanofiber hydrogel PA-TIMP-QK may provide an intelligent drug delivery system that responds to the microenvironment and promotes regeneration and repair after cerebral ischemia/reperfusion injury.
文摘Presented in this manuscript are conventional electrical engineering tools to model the earth as a rotating electrical machine. Calculations using known parameters of the earth and measured field data has resulted in new understanding of the earth’s electrical system and gyroscopic rotation. The material makeup of the inner earth is better understood based on derived permeability and permittivity constants. The planet has been modeled as simple coils and then as a parallel impedance circuit which has led to fundamental insight into planetary speed control and RLC combination for Schumann Resonance of 7.83 Hz. Torque and Voltage Constants and the inverse Speed Constant are calculated using three methods and all compare favorably with Newton’s Gravitational Constant. A helical resonator is referenced and Schumann’s Resonant ideal frequency is calculated and compared with others idealism. A new theory of gravity based on particle velocity selector at the poles is postulated. Two equations are presented as the needed links between Faraday’s electromagnetism and Newtonian physics. Acceleration and Deceleration of earth is explained as a centripetal governor. A new equation for planetary attraction and the attraction of atomic matter is theorized. Rotation of the earth’s electrical coil is explained in terms of the Richardson effect. Electric power transfer from the sun to the planets is proposed via Flux Transfer Events. The impact of this evolving science of electromagnetic modeling of planets will be magnified as the theory is proven, and found to be useful for future generations of engineers and scientists who seek to discover our world and other planets.
文摘To improve ambient air quality and return citizens blue sky and white clouds,national and local administrative departments all issue corresponding countermeasures to strictly prevent and control air pollution,reduce total pollutant emission,and improve environmental management level. In this paper,taking Tianjin as an example,change situation of regional air pollution and its prevention and control management situation were summarized.
文摘The input-output pollution control model given in [1] is generalized. The generalization makes it easier for the model to handle many problem instances. A linear program is used to solve the new model. An example is given to show that the new model can handle classes of problems that the original model cannot handle.
基金the National Key Research Development Program of China(2016YFC0208901 and 2017YFC0212100)the National Natural Science Foundation of China(71722003 and 71690244)。
文摘China’s past economic growth has substantially relied on fossil fuels,causing serious air pollution issues.Decoupling economic growth and pollution has become the focus in developing ecological civilization in China.We have analyzed the three-decade progress of air pollution controls in China,highlighting a strategic transformation from emission control toward air quality management.Emission control of sulfur dioxide(SO2)resolved the deteriorating acid rain issue in China in 2007.Since 2013,control actions on multiple precursors and sectors have targeted the reduction of the concentration of fine particulate matter(PM2.5),marking a transition to an air-quality-oriented strategy.Increasing ozone(O3)pollution further requires O3 and PM2.5 integrated control strategies with an emphasis on their complex photochemical interactions.Fundamental improvement of air quality in China,as a key indicator for the success of ecological civilization construction,demands the deep de-carbonization of China’s energy system as well as more synergistic pathways to address air pollution and global climate change simultaneously.
基金The Key Project of Shanghai Council of Science and Technology(No. 032312043)
文摘Increasing attention has been paid to air pollution control (APC) residues in China recently due to the rising proportion of waste incineration and the hazardous characteristics of the residues, among which heavy metal leaching toxicity plays an important role. Leaching behavior and potential risk of Pb and Zn in the APC residues from a Shanghai municipal solid waste (MSW) incinerator was studied, based on the leaching tests under different conditions and theoretical calculation using a geochemical thermodynamic equilibrium model MINTEQA2. Results showed that, extractant species and liquid to solid (L/S) ratio predominantly controlled the leaching toxicity of Pb and Zn, while ionic strength, vibration method and leaching time had less effect on the metals release. Leachate/final pH determined the metal leaching behavior, which changed the speciation of heavy metals in the extraction system. The equilibrium aqueous speciation, precipitation-dissolution of Pb and Zn was investigated according to the model computation, which was well in agreement with the experimental results.
基金the National Key Basic Research Program of China (973program),a key project of the Shandong Provincial Environmental Protection Department,the Niche Area Development Scheme of the Hong Kong Polytechnic University,the Hong Kong Research Grants Council,the central level,scientific research institutes for basic R & D special fund business
文摘For the 2008 Olympic Games, drastic control measures were implemented on industrial and urban emissions of sulfur dioxide (SO2), nitrogen oxides (NOx) and other pollutants to address the issues of poor air quality in Beijing. To investigate the effects of SO2 and NOx reductions on the particulate sulfate and nitrate concentrations as well as their size distributions, size-segregated aerosol samples were collected using micro-orifice uniform deposit impactors (MOUDIs) at urban and downwind rural sites in Beijing before and after full-scale controls. During the sampling period, the mass concentrations of fine particles (PMI.s) at the urban and rural sites were 94.0 and 85.9 p.g m-3, respectively. More than 90% of the sulfates and 60% of nitrates formed as fine particles. Benefiting from the advantageous meteorological conditions and the source controls, sulfates were observed in rather low concentrations and primarily in condensation mode during the Olympics. The effects of the control measures were separately analyzed for the northerly and the southerly air-mass-dominated days to account for any bias. After the control measures were implemented, PM, sulfates, and nitrates were significantly reduced when the northerly air masses prevailed, with a higher percentage of reduction in larger particles. The droplet mode particles, which dominated the sulfates and nitrates before the controls were implemented, were remarkably reduced in mass concentration after the control measures were implemented. Nevertheless, when the polluted southerly air masses prevailed, the local source control measures in Beijing did not effectively reduce the ambient sulfate concentration due to the enormous regional contribution from the North China Plain.