Objective:To study the enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stres...Objective:To study the enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stress.Methods: Patients with diabetes lower extremity arterial disease accepting 3D-CEMRA examination in our hospital between May 2013 and December 2015 were selected as the pathology group, and the enhancement maximum slope of increase was measured;healthy volunteers receiving physical examination in our hospital during the same period were selected as control group, and serum levels of endothelial oxidative stress injury-related molecules of two groups of subjects were determined.Results:The enhancement maximum slope of increase of the lesion-side anterior tibial artery, posterior tibial artery, peroneal artery and dorsalis pedis artery of pathology group were significantly lower than those of the unaffected-side;serum CyPA, ERK1, ERK2, Akt, JAK, HO-1 and CO content of pathology group were significantly higher than those of control group and negatively correlated with the enhancement maximum slope of increase of lower extremity while Prdx6, SOD, CAT, GSH-Px, eNOS and NO content were significantly lower than those of control group and positively correlated with the enhancement maximum slope of increase of lower extremity.Conclusion: The enhancement maximum slope of increase of magnetic resonance angiography significantly reduces in patients with diabetes lower extremity arterial disease and is closely related to oxidative stress-induced endothelial injury as well as eNOS/NO and HO-1/CO system function change.展开更多
Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting sig...Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.展开更多
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ...The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.展开更多
Pulmonary contrast enhanced magnetic resonance angiography(CE-MRA) is useful for the primary diagnosis of pulmonary embolism(PE). Many sites have chosen not to use CE-MRA as a first line of diagnostic tool for PE beca...Pulmonary contrast enhanced magnetic resonance angiography(CE-MRA) is useful for the primary diagnosis of pulmonary embolism(PE). Many sites have chosen not to use CE-MRA as a first line of diagnostic tool for PE because of the speed and higher efficacy of computerized tomographic angiography(CTA). In this review, we discuss the strengths and weaknesses of CEMRA and the appropriate imaging scenarios for the primary diagnosis of PE derived from our unique multiinstitutional experience in this area. The optimal patient for this test has a low to intermediate suspicion for PE based on clinical decision rules. Patients in extremis are not candidates for this test. Younger women(< 35 years of age) and patients with iodinated contrast allergies are best served by using this modality We discuss the history of the use of this test, recent technical innovations, artifacts, direct and indirect findings for PE, ancillary findings, and the effectiveness(patient outcomes) of CE-MRA for the exclusion of PE. Current outcomes data shows that CE-MRA and NM V/Q scans are effective alternative tests to CTA for the primary diagnosis of PE.展开更多
Objective:We aimed to evaluate the diagnostic performance of three-dimensional whole-heart magnetic resonance coronary angiography(MRCA)in detecting coronary artery disease(CAD)with invasive coronary angiography as th...Objective:We aimed to evaluate the diagnostic performance of three-dimensional whole-heart magnetic resonance coronary angiography(MRCA)in detecting coronary artery disease(CAD)with invasive coronary angiography as the reference standard.Methods:We searched PubMed and Embase for studies evaluating the diagnostic performance of three-dimensional whole-heart MRCA for the diagnosis of CAD with invasive coronary angiography as the reference standard.The bivariate mixed-effects regression model was applied to synthesize available data.The clinical utility of whole-heart MRCA was calculated by the posttest probability based on Bayes’s theorem.Results:Eighteen studies were included,of which 16 provided data at the artery level.Patient-based analysis revealed a pooled sensitivity of 0.90(95%confi dence interval[CI]0.87–0.93)and specifi city of 0.79(95%CI 0.73–0.84),while the pooled estimates were 0.86(95%CI 0.82–0.89)and 0.89(95%CI 0.84–0.92),respectively,at the artery level.The areas under the summary receiver operating characteristic curve were 0.93(95%CI 0.90–0.95)and 0.92(95%CI 0.90–0.94)at the patient and artery levels,respectively.With a pretest probability of 50%,the patients’posttest probabilities of CAD were 81%for positive results and 11%for negative results.Conclusions:Whole-heart MRCA can be an alternative noninvasive method for diagnosis and assessment of CAD.展开更多
BACKGROUND Chronic cocaine use is associated with stroke, coronary artery disease and myocardial infarction, resulting in severe impairments or sudden mortality. In the absence of clear cardiovascular symptoms, indivi...BACKGROUND Chronic cocaine use is associated with stroke, coronary artery disease and myocardial infarction, resulting in severe impairments or sudden mortality. In the absence of clear cardiovascular symptoms, individuals with cocaine use disorder (iCUD) seeking addiction treatment receive mostly psychotherapy and psychiatric pharmacotherapy, with no attention to vascular disease (i.e., atherosclerosis). Little is known about the pre-clinical signs of cardiovascular risk in iCUD and early signs of vascular disease are undetected in this underserved population. AIM To assess inflammation, plaque burden and plaque composition in iCUD aiming to detect markers of atherosclerosis and vascular disease. METHODS The bilateral carotid arteries were imaged with positron emission tomography/magnetic resonance imaging (PET/MRI) in iCUD asymptomatic for cardiovascular disease, healthy controls, and individuals with cardiovascular risk. PET with 18F-fluorodeoxyglucose (18F-FDG) evaluated vascular inflammation and 3-D dark-blood MRI assessed plaque burden including wall area and thickness. Drug use and severity of addiction were assessed with standardized instruments. RESULTS The majority of iCUD and controls had carotid FDG-PET signal greater than 1.6 but lower than 3, indicating the presence of mild to moderate inflammation. However, the MRI measure of wall structure was thicker in iCUD as compared to the controls and cardiovascular risk group, indicating greater carotid plaque burden. iCUD had larger wall area as compared to the healthy controls but not as compared to the cardiovascular risk group, indicating structural wall similarities between the non-control study groups. In iCUD, wall area correlated with greater cocaine withdrawal and craving. CONCLUSION These preliminary results show markers of carotid artery disease burden in cardiovascular disease-asymptomatic iCUD. Broader trials are warranted to develop protocols for early detection of cardiovascular risk and preventive intervention in iCUD.展开更多
Alzheimer’s disease (AD) is a dementing disorder and one of the major public health problems in countries with greater longevity. The cerebral cortical thickness and cerebral blood flow (CBF), which are considered as...Alzheimer’s disease (AD) is a dementing disorder and one of the major public health problems in countries with greater longevity. The cerebral cortical thickness and cerebral blood flow (CBF), which are considered as morphological and functional image features, respectively, could be decreased in specific cerebral regions of patients with dementia of Alzheimer type. Therefore, the aim of this study was to develop a computer-aided classification system for AD patients based on machine learning with the morphological and functional image features derived from a magnetic resonance (MR) imaging system. The cortical thicknesses in ten cerebral regions were derived as morphological features by using gradient vector trajectories in fuzzy membership images. Functional CBF maps were measured with an arterial spin labeling technique, and ten regional CBF values were obtained by registration between the CBF map and Talairach atlas using an affine transformation and a free form deformation. We applied two systems based on an arterial neural network (ANN) and a support vector machine (SVM), which were trained with 4 morphological and 6 functional image features, to 15 AD patients and 15 clinically normal (CN) subjects for classification of AD. The area under the receiver operating characteristic curve (AUC) values for the two systems based on the ANN and SVM with both image?features were 0.901 and 0.915, respectively. The AUC values for the ANN-and SVM-based systems with the morphological features were 0.710 and 0.660, respectively, and those with the functional features were 0.878 and 0.903, respectively. Our preliminary results suggest that the proposed method may have potential for assisting radiologists in the differential diagnosis of AD patients by using morphological and functional image features.展开更多
Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical pre...Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical presentation,imaging is often mandatory in order to diagnose BC.Among imaging modalities,magnetic resonance cholangiography(MRC)has gained widespread acceptance as a tool to represent the reconstructed biliary tree noninvasively,using both the conventional technique(based on heavily T2-weighted sequences)and contrast-enhanced MRC(based on the acquisition of T1-weighted sequences after the administration of hepatobiliary contrast agents).On this basis,MRC is generally indicated to:(1)avoid unnecessary procedures of direct cholangiography in patients with a negative examination and/or identify alternative complications;and(2)provide a road map for interventional procedures or surgery.As illustrated in the review,MRC is accurate in the diagnosis of different types of biliarycomplications,including anastomotic strictures,nonanastomotic strictures,leakage and stones.展开更多
BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and H...BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD.展开更多
The main symptom of patients with Alzheimer’s disease is cognitive dysfunction. Alzheimer’s disease is mainly diagnosed based on changes in brain structure. Functional connectivity reflects the synchrony of function...The main symptom of patients with Alzheimer’s disease is cognitive dysfunction. Alzheimer’s disease is mainly diagnosed based on changes in brain structure. Functional connectivity reflects the synchrony of functional activities between non-adjacent brain regions, and changes in functional connectivity appear earlier than those in brain structure. In this study, we detected resting-state functional connectivity changes in patients with Alzheimer’s disease to provide reference evidence for disease prediction. Functional magnetic resonance imaging data from patients with Alzheimer’s disease were used to show whether particular white and gray matter areas had certain functional connectivity patterns and if these patterns changed with disease severity. In nine white and corresponding gray matter regions, correlations of normal cognition, early mild cognitive impairment, and late mild cognitive impairment with blood oxygen level-dependent signal time series were detected. Average correlation coefficient analysis indicated functional connectivity patterns between white and gray matter in the resting state of patients with Alzheimer’s disease. Functional connectivity pattern variation correlated with disease severity, with some regions having relatively strong or weak correlations. We found that the correlation coefficients of five regions were 0.3–0.5 in patients with normal cognition and 0–0.2 in those developing Alzheimer’s disease. Moreover, in the other four regions, the range increased to 0.45–0.7 with increasing cognitive impairment. In some white and gray matter areas, there were specific connectivity patterns. Changes in regional white and gray matter connectivity patterns may be used to predict Alzheimer’s disease;however, detailed information on specific connectivity patterns is needed. All study data were obtained from the Alzheimer’s Disease Neuroimaging Initiative Library of the Image and Data Archive Database.展开更多
Gadoxetic acid- or gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging(EOB-MRI) achieves excellent lesion detection and characterization for both hypervascular hepatocellula...Gadoxetic acid- or gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging(EOB-MRI) achieves excellent lesion detection and characterization for both hypervascular hepatocellular carcinoma(HCC) in arterial phase imagingand hypovascular early HCC(small well-differentiated HCC of the vaguely nodular type) in hepatobiliary phase imaging, and has become an indispensable imaging modality in the treatment of HCC. Early HCCs have been detected more frequently since the introduction of EOB-MRI into daily clinical practice. Early HCC is known to progress to conventional hypervascular HCC, and many risk factors have been identified for the hypervascularization of early HCC including the diameter of the tumor, presence of fat, and imaging findings of EOB-MRI. The rate of the development of hypervascular HCC was previously reported to be high in patients with chronic liver disease and early HCC. The presence of early HCC is regarded as a predictor for the recurrence of HCC following hepatic resection. On the other hand, although early HCC itself is currently not regarded as a target lesion for hepatic resection, early HCC at high risk of hypervascularity needs to be treated by local ablation therapy. If concomitant early HCC with progressed HCC is at high risk of hypervascularization and the functional liver reserve of a patient is sufficient, its simultaneous treatment at the time of hepatic resection for progressed HCC is recommended. Further studies on larger numbers of patients are needed before this strategy is adopted.展开更多
Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential...Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging.In addition to sonography and computer tomography,MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases,for determining disease severity,and for assessing therapeutic success.MRI techniques have improved over the last few decades,revealing not just morphologic information,but functional information about perfusion,diffusion and hemodynamics as well.Four-dimensional(4D)flow MRI,a time-resolved phase contrast-MRI with three-dimensional(3D)anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body.The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest.Over the last few years,4D flow MRI has been increasingly performed in the abdominal region.By applying different acceleration techniques,taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min.These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system.The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition,data analysis,visualization and quantification.Furthermore,in this article we highlight its development,focussing on the clinical application of the technique.展开更多
X-ray computed tomography(CT),ultrasonography(US)and radionuclide scanning are important clinical methods for evaluating morphology of the kidney.These modalities are also applicable for estimating kidney function wit...X-ray computed tomography(CT),ultrasonography(US)and radionuclide scanning are important clinical methods for evaluating morphology of the kidney.These modalities are also applicable for estimating kidney function with time lapse analysis using proper contrastmedia as may be necessary.In the case of US,it can estimate kidney function based on the measurement of blood flow using the Doppler effect.Formerly,magnetic resonance imaging(MRI)was an inappropriate diagnostic imaging technique for abdominal organs because of their respiratory displacements.However,MRI is now actively used for kidney as well as liver or other parenchymal organs,in tandem with the technological advances.Unlike unenhanced X-ray CT,"conventional"MRI can distinguish the border between cortex and medulla in T1 or T2 weighted images.It was known that the border blurred with decreasing kidney function.Moreover,several other particular imaging methods were introduced in recent years,and these could be called"functional"MRI.In this review,the following are discussed:functional MRI for chronic kidney disease,which include blood oxygenation level-dependent MRI for evaluation of hypoxia,diffusion-weighted imagingfor evaluation of fibrosis,diffusion tensor imaging for evaluation of microstructure,and arterial spin labeling to evaluate the amount of organ perfusion,accompanied with several related articles.The ultimate goal of functional MRI is to provide useful in vivo information repeatedly for daily medical treatment non-invasively.展开更多
The purpose of this study was to demonstrate a simple and fast method for solving the time-dependent Bloch-McConnell equations describing the behavior of magnetization in magnetic resonance imaging (MRI) in the presen...The purpose of this study was to demonstrate a simple and fast method for solving the time-dependent Bloch-McConnell equations describing the behavior of magnetization in magnetic resonance imaging (MRI) in the presence of multiple chemical exchange pools. First, the time-dependent Bloch- McConnell equations were reduced to a homogeneous linear differential equation, and then a simple equation was derived to solve it using a matrix operation and Kronecker tensor product. From these solutions, the longitudinal relaxation rate (R1ρ) and transverse relaxation rate in the rotating frame (R2ρ) and Z-spectra were obtained. As illustrative examples, the numerical solutions for linear and star-type three-pool chemical exchange models and linear, star- type, and kite-type four-pool chemical exchange models were presented. The effects of saturation time (ST) and radiofrequency irradiation power (ω1) on the chemical exchange saturation transfer (CEST) effect in these models were also investigated. Although R1ρ and R2ρ were not affected by the ST, the CEST effect observed in the Z-spectra increased and saturated with increasing ST. When ω1 was varied, the CEST effect increased with increasing ω1 in R1ρ, R2ρ, and Z-spectra. When ω1 was large, however, the spillover effect due to the direct saturation of bulk water protons also increased, suggesting that these parameters must be determined in consideration of both the CEST and spillover effects. Our method will be useful for analyzing the complex CEST contrast mechanism and for investigating the optimal conditions for CEST MRI in the presence of multiple chemical exchange pools.展开更多
We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues an...We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues and pathologic mechanisms. Myelin abnormalities, different types of edema or neurodegenerative processes, can cause areas of abnormal T2 signal, variable enhancement, and patterns of diffusivity of MCP. Pathologies such as demyelinating disorders or certain neurodegenerative entities(e.g., multiple system atrophy or fragile X-associated tremor-ataxia syndrome) appear to have predilection for MCP. Careful evaluation of concomitant imaging findings in the brain or brainstem; and focused correlation with key clinical findings such as immunosuppression for progressive multifocal leukoencephalopahty; hypertension, post-transplant status or high dose chemotherapy for posterior reversible encephalopathy; electrolyte disorders for myelinolysis or suspected toxic-drug related encephalopathy; would yield an appropriate and accurate differential diagnosis in the majority of cases.展开更多
Nano-volt magnetic resonance sounding(MRS) signals are sufficiently weak so that during the actual measurement, they are affected by environmental electromagnetic noise, leading to inaccuracy of the extracted characte...Nano-volt magnetic resonance sounding(MRS) signals are sufficiently weak so that during the actual measurement, they are affected by environmental electromagnetic noise, leading to inaccuracy of the extracted characteristic parameters and hindering effective inverse interpretation. Considering the complexity and non-homogeneous spatial distribution of environmental noise and based on the theory of adaptive noise cancellation, a model system for noise cancellation using multi-reference coils was constructed to receive MRS signals. The feasibility of this system with theoretical calculation and experiments was analyzed and a modified sigmoid variable step size least mean square(SVSLMS) algorithm for noise cancellation was presented. The simulation results show that, the multi-reference coil method performs better than the single one on both signal-to-noise ratio(SNR) improvement and signal waveform optimization after filtering, under the condition of different noise correlations in the reference coils and primary detecting coils and different SNRs. In particular, when the noise correlation is poor and the SNR<0, the SNR can be improved by more than 8 dB after filtering with multi-reference coils. And the average fitting errors for initial amplitude and relaxation time are within 5%. Compared with the normalized least mean square(NLMS) algorithm and multichannel Wiener filter and processing field test data, the effectiveness of the proposed method is verified.展开更多
Magnetic resonance imaging(MRI), magnetic resonance angiography(MRA) and magnetic resonance spectroscopy(MRS) are fundamental concepts used in modern medicine to improve health care. These concepts are based on the pr...Magnetic resonance imaging(MRI), magnetic resonance angiography(MRA) and magnetic resonance spectroscopy(MRS) are fundamental concepts used in modern medicine to improve health care. These concepts are based on the principle of nuclear magnetic resonance(NMR). Over the years, various laboratories around the world have applied different numerical techniques based on the Bloch NMR equations to solve specific problems in physics, biology, chemistry, engineering and medicine. The ultimate goal of any physician is to obtain maximum physical, biophysical, chemical and biological information on any tissue or cell under examination. This goal can be achieved by solving the Bloch NMR flow equations analytically. In this review, we present the basic principle of NMR/MRI in a way that can be easily understood by any researcher who needs an NMR concept to solve a specific medical problems. After a very brief history of the subject, a second order, non homogeneous, time-dependent differential equation derived from the Bloch NMR equation is presented. This equation has the basic intrinsic properties of MRI, MRA and MRS that can be extracted by means of classical and quantum mechanics for possible application in nanomedicine.展开更多
BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgi...BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgical plan- ning or even precluded the necessity of surgery. Here we report our preliminary results of modified magnetic reso- nance angiography ( MRA ) using sensitivity encoding ( SENSE) through comparative study with conventional digital subtraction angiography (DSA) and CT arterial por- tography (CTAP). METHODS: Sixteen patients with suspected liver diseases were included in the study. All of them received both dy- namic MRI of the liver using SENSE and digital DSA with CTAP within a two-week interval. The four-phase MRA was reconstructed from source images of the coronal dy- namic study. The arterial phase of the modified MRA was compared with DSA in the evaluation of hepatic arteries and the portal phase compared with CT portography recon- structed from source images of CTAP. In dynamic study of the liver, a fixed dose (20 ml) of contrast medium and scan timing were used. RESULTS: The main branches and variations of the hepatic arterial system were well shown on the modified MRA, al- though the marginal branches of hepatic arteries were of poor quality. The figures of portal veins on MRA were as clear as or superior to those of CTAP. In addition, the su- prarenal inferior vena cava (IVC) was well demonstrated on MRA and/or non contrast-enhanced coronal balanced fast-field echo (b-FFE) scan sequence in most cases. MRI detected most parenchymal lesions of the liver and hemo- dynamics of these lesions could be evaluated on source ima- ges of the modified MRA. MRI/MRA also serendipitously revealed several extrahepatic disease entities or variations that were not found on DSA/CTAP. CONCLUSIONS: The modified MRA using SENSE is a cost-effective modality of examination for the demonstra- tion of the whole hepatic vascular system. Combined with MRI, it has the potential as a one-stop imaging modality in the preoperative evaluation in fields such as OLT.展开更多
Parkinson's disease is a neurodegenerative disorder caused by loss of dopamine neurons in the substantia nigra pars compacta. Tremor, rigidity, and bradykinesia are the major symptoms of the disease. These motor i...Parkinson's disease is a neurodegenerative disorder caused by loss of dopamine neurons in the substantia nigra pars compacta. Tremor, rigidity, and bradykinesia are the major symptoms of the disease. These motor impairments are often accompanied by affective and emotional dysfunctions which have been largely studied over the last decade. The aim of this study was to investigate emotional processing organization in the brain of patients with Parkinson's disease and to explore whether there are differences between recognition of different types of emotions in Parkinson's disease. We examined 18 patients with Parkinson's disease(8 men, 10 women) with no history of neurological or psychiatric comorbidities. All these patients underwent identical brain blood oxygenation level-dependent functional magnetic resonance imaging for emotion evaluation. Blood oxygenation level-dependent functional magnetic resonance imaging results revealed that the occipito-temporal cortices, insula, orbitofrontal cortex, basal ganglia, and parietal cortex which are involved in emotion processing, were activated during the functional control. Additionally, positive emotions activate larger volumes of the same anatomical entities than neutral and negative emotions. Results also revealed that Parkinson's disease associated with emotional disorders are increasingly recognized as disabling as classic motor symptoms. These findings help clinical physicians to recognize the emotional dysfunction of patients with Parkinson's disease.展开更多
AIM: To investigate the merits of texture analysis on parametric maps derived from pharmacokinetic modeling with dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) as imaging biomarkers for the prediction o...AIM: To investigate the merits of texture analysis on parametric maps derived from pharmacokinetic modeling with dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) as imaging biomarkers for the prediction of treatment response in patients with head and neck squamous cell carcinoma(HNSCC). METHODS: In this retrospective study,19 HNSCC patients underwent pre- and intra-treatment DCEMRI scans at a 1.5T MRI scanner. All patients had chemo-radiation treatment. Pharmacokinetic modeling was performed on the acquired DCE-MRI images,generating maps of volume transfer rate(Ktrans) and volume fraction of the extravascular extracellular space(ve). Image texture analysis was then employed on maps of Ktrans and ve,generating two texture measures: Energy(E) and homogeneity.RESULTS: No significant changes were found for the mean and standard deviation for Ktrans and ve between pre- and intra-treatment(P > 0.09). Texture analysis revealed that the imaging biomarker E of ve was significantly higher in intra-treatment scans,relative to pretreatment scans(P < 0.04). CONCLUSION: Chemo-radiation treatment in HNSCC significantly reduces the heterogeneity of tumors.展开更多
文摘Objective:To study the enhancement maximum slope of increase of magnetic resonance angiography in patients with diabetes lower extremity arterial disease and its correlation with endothelial injury and oxidative stress.Methods: Patients with diabetes lower extremity arterial disease accepting 3D-CEMRA examination in our hospital between May 2013 and December 2015 were selected as the pathology group, and the enhancement maximum slope of increase was measured;healthy volunteers receiving physical examination in our hospital during the same period were selected as control group, and serum levels of endothelial oxidative stress injury-related molecules of two groups of subjects were determined.Results:The enhancement maximum slope of increase of the lesion-side anterior tibial artery, posterior tibial artery, peroneal artery and dorsalis pedis artery of pathology group were significantly lower than those of the unaffected-side;serum CyPA, ERK1, ERK2, Akt, JAK, HO-1 and CO content of pathology group were significantly higher than those of control group and negatively correlated with the enhancement maximum slope of increase of lower extremity while Prdx6, SOD, CAT, GSH-Px, eNOS and NO content were significantly lower than those of control group and positively correlated with the enhancement maximum slope of increase of lower extremity.Conclusion: The enhancement maximum slope of increase of magnetic resonance angiography significantly reduces in patients with diabetes lower extremity arterial disease and is closely related to oxidative stress-induced endothelial injury as well as eNOS/NO and HO-1/CO system function change.
文摘Objective To compare 16-slice multi-detector spiral computed tomography (MDCT) and breathhold 3D magnetic resonance (MR) coronary angiography in the visualization of coronary arteries and the accuracy of detecting significant (> 50%) coronary stenoses in patients with suspected coronary artery disease. Methods Forty patients were examined by 16-slice CT (GE, Lightspeedl6)and MR (GE,Twinspeed) within 3 days; 31 of them underwent conventional coronary angiography (CAG) within 2 weeks after CT and MR scan. CT was performed with 16× 1.25 mm detector collimation, 0.5 s rotation time and images were reconstructed at 60%-75% of the cardiac cycle. MR was performed with breath hold 3D FIESTA (TR4.0 ms, TE1.7 ms, flip angle 65, slice thickness 3 mm, FOV 280 mm, matrix 256× 192). Mean heart rate was 63 ± 5.8 bpm and β-blocker was used in 24 patients. MR and CT image quality was evaluated in 9 coronary segments (RCA1, RCA2, RCA3, LM, LAD1, LAD2, LAD3, LCX1, LCX2) using a four-point grading scale.Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated for detection of significant stenosis using CAG as the gold standard. Results 16-slice CT showed higher image quality in most coronary segments except RCA2.Forty-three segments were diagnosed as significant stenosis by CAG, 36 and 27 of these were correctly detected by CT and MR respectively. Sensitivity, specificity, positive predictive value, and negative predictive value of 16-slice CT and MR for detecting significant stenosis were 83 %, 84 %, 49 %, 97 % and 63 %, 90 %, 55 %, 93 %, respectively. Conclusion Sixteen-slice CT showed higher image quality in most coronary segments excepted for middle RCA. 16-slice CT had higher sensitivity than MR for detection of coronary significant stenosis, whereas MR had higher specificity than CT. Both CT and MR showed high negative predictive value,which is useful for excluding coronary stenosis in symptomatic patients.
基金the Medical Program of Scientific & Technical Foundation in Xiamen in 2008, No. 3502Z20084028
文摘The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
基金research support of the Department of Radiology,UW-Madison and GE Healthcare
文摘Pulmonary contrast enhanced magnetic resonance angiography(CE-MRA) is useful for the primary diagnosis of pulmonary embolism(PE). Many sites have chosen not to use CE-MRA as a first line of diagnostic tool for PE because of the speed and higher efficacy of computerized tomographic angiography(CTA). In this review, we discuss the strengths and weaknesses of CEMRA and the appropriate imaging scenarios for the primary diagnosis of PE derived from our unique multiinstitutional experience in this area. The optimal patient for this test has a low to intermediate suspicion for PE based on clinical decision rules. Patients in extremis are not candidates for this test. Younger women(< 35 years of age) and patients with iodinated contrast allergies are best served by using this modality We discuss the history of the use of this test, recent technical innovations, artifacts, direct and indirect findings for PE, ancillary findings, and the effectiveness(patient outcomes) of CE-MRA for the exclusion of PE. Current outcomes data shows that CE-MRA and NM V/Q scans are effective alternative tests to CTA for the primary diagnosis of PE.
基金The study was supported by a major international(regional)joint research project of the National Natural Science Foundation of China(no.81620108015).
文摘Objective:We aimed to evaluate the diagnostic performance of three-dimensional whole-heart magnetic resonance coronary angiography(MRCA)in detecting coronary artery disease(CAD)with invasive coronary angiography as the reference standard.Methods:We searched PubMed and Embase for studies evaluating the diagnostic performance of three-dimensional whole-heart MRCA for the diagnosis of CAD with invasive coronary angiography as the reference standard.The bivariate mixed-effects regression model was applied to synthesize available data.The clinical utility of whole-heart MRCA was calculated by the posttest probability based on Bayes’s theorem.Results:Eighteen studies were included,of which 16 provided data at the artery level.Patient-based analysis revealed a pooled sensitivity of 0.90(95%confi dence interval[CI]0.87–0.93)and specifi city of 0.79(95%CI 0.73–0.84),while the pooled estimates were 0.86(95%CI 0.82–0.89)and 0.89(95%CI 0.84–0.92),respectively,at the artery level.The areas under the summary receiver operating characteristic curve were 0.93(95%CI 0.90–0.95)and 0.92(95%CI 0.90–0.94)at the patient and artery levels,respectively.With a pretest probability of 50%,the patients’posttest probabilities of CAD were 81%for positive results and 11%for negative results.Conclusions:Whole-heart MRCA can be an alternative noninvasive method for diagnosis and assessment of CAD.
基金Supported by NIDA,No.K23DA045928-01(to Bachi K) and No.R01DA041528(to Goldstein RZ)NIH/NHLBI,No.R01HL071021+1 种基金Translational and Molecular Imaging Institute internal funding(to Fayad ZAF)American Heart Association Grant in Aid,No.17GRNT33420119(to Mani VM)
文摘BACKGROUND Chronic cocaine use is associated with stroke, coronary artery disease and myocardial infarction, resulting in severe impairments or sudden mortality. In the absence of clear cardiovascular symptoms, individuals with cocaine use disorder (iCUD) seeking addiction treatment receive mostly psychotherapy and psychiatric pharmacotherapy, with no attention to vascular disease (i.e., atherosclerosis). Little is known about the pre-clinical signs of cardiovascular risk in iCUD and early signs of vascular disease are undetected in this underserved population. AIM To assess inflammation, plaque burden and plaque composition in iCUD aiming to detect markers of atherosclerosis and vascular disease. METHODS The bilateral carotid arteries were imaged with positron emission tomography/magnetic resonance imaging (PET/MRI) in iCUD asymptomatic for cardiovascular disease, healthy controls, and individuals with cardiovascular risk. PET with 18F-fluorodeoxyglucose (18F-FDG) evaluated vascular inflammation and 3-D dark-blood MRI assessed plaque burden including wall area and thickness. Drug use and severity of addiction were assessed with standardized instruments. RESULTS The majority of iCUD and controls had carotid FDG-PET signal greater than 1.6 but lower than 3, indicating the presence of mild to moderate inflammation. However, the MRI measure of wall structure was thicker in iCUD as compared to the controls and cardiovascular risk group, indicating greater carotid plaque burden. iCUD had larger wall area as compared to the healthy controls but not as compared to the cardiovascular risk group, indicating structural wall similarities between the non-control study groups. In iCUD, wall area correlated with greater cocaine withdrawal and craving. CONCLUSION These preliminary results show markers of carotid artery disease burden in cardiovascular disease-asymptomatic iCUD. Broader trials are warranted to develop protocols for early detection of cardiovascular risk and preventive intervention in iCUD.
文摘Alzheimer’s disease (AD) is a dementing disorder and one of the major public health problems in countries with greater longevity. The cerebral cortical thickness and cerebral blood flow (CBF), which are considered as morphological and functional image features, respectively, could be decreased in specific cerebral regions of patients with dementia of Alzheimer type. Therefore, the aim of this study was to develop a computer-aided classification system for AD patients based on machine learning with the morphological and functional image features derived from a magnetic resonance (MR) imaging system. The cortical thicknesses in ten cerebral regions were derived as morphological features by using gradient vector trajectories in fuzzy membership images. Functional CBF maps were measured with an arterial spin labeling technique, and ten regional CBF values were obtained by registration between the CBF map and Talairach atlas using an affine transformation and a free form deformation. We applied two systems based on an arterial neural network (ANN) and a support vector machine (SVM), which were trained with 4 morphological and 6 functional image features, to 15 AD patients and 15 clinically normal (CN) subjects for classification of AD. The area under the receiver operating characteristic curve (AUC) values for the two systems based on the ANN and SVM with both image?features were 0.901 and 0.915, respectively. The AUC values for the ANN-and SVM-based systems with the morphological features were 0.710 and 0.660, respectively, and those with the functional features were 0.878 and 0.903, respectively. Our preliminary results suggest that the proposed method may have potential for assisting radiologists in the differential diagnosis of AD patients by using morphological and functional image features.
文摘Despite advances in patient and graft management,biliary complications(BC)still represent a challenge both in the early and delayed period after orthotopic liver transplantation(OLT).Because of unspecific clinical presentation,imaging is often mandatory in order to diagnose BC.Among imaging modalities,magnetic resonance cholangiography(MRC)has gained widespread acceptance as a tool to represent the reconstructed biliary tree noninvasively,using both the conventional technique(based on heavily T2-weighted sequences)and contrast-enhanced MRC(based on the acquisition of T1-weighted sequences after the administration of hepatobiliary contrast agents).On this basis,MRC is generally indicated to:(1)avoid unnecessary procedures of direct cholangiography in patients with a negative examination and/or identify alternative complications;and(2)provide a road map for interventional procedures or surgery.As illustrated in the review,MRC is accurate in the diagnosis of different types of biliarycomplications,including anastomotic strictures,nonanastomotic strictures,leakage and stones.
基金Supported by the Key Research and Development Plan of Shaanxi Province,No.2021SF-298.
文摘BACKGROUND Neurovascular compression(NVC) is the main cause of primary trigeminal neuralgia(TN) and hemifacial spasm(HFS). Microvascular decompression(MVD) is an effective surgical method for the treatment of TN and HFS caused by NVC. The judgement of NVC is a critical step in the preoperative evaluation of MVD, which is related to the effect of MVD treatment. Magnetic resonance imaging(MRI) technology has been used to detect NVC prior to MVD for several years. Among many MRI sequences, three-dimensional time-of-flight magnetic resonance angiography(3D TOF MRA) is the most widely used. However, 3D TOF MRA has some shortcomings in detecting NVC. Therefore, 3D TOF MRA combined with high resolution T2-weighted imaging(HR T2WI) is considered to be a more effective method to detect NVC.AIM To determine the value of 3D TOF MRA combined with HR T2WI in the judgment of NVC, and thus to assess its value in the preoperative evaluation of MVD.METHODS Related studies published from inception to September 2022 based on PubMed, Embase, Web of Science, and the Cochrane Library were retrieved. Studies that investigated 3D TOF MRA combined with HR T2WI to judge NVC in patients with TN or HFS were included according to the inclusion criteria. Studies without complete data or not relevant to the research topics were excluded. The Quality Assessment of Diagnostic Accuracy Studies checklist was used to assess the quality of included studies. The publication bias of the included literature was examined by Deeks’ test. An exact binomial rendition of the bivariate mixed-effects regression model was used to synthesize data. Data analysis was performed using the MIDAS module of statistical software Stata 16.0. Two independent investigators extracted patient and study characteristics, and discrepancies were resolved by consensus. Individual and pooled sensitivities and specificities were calculated. The I_(2) statistic and Q test were used to test heterogeneity. The study was registered on the website of PROSERO(registration No. CRD42022357158).RESULTS Our search identified 595 articles, of which 12(including 855 patients) fulfilled the inclusion criteria. Bivariate analysis showed that the pooled sensitivity and specificity of 3D TOF MRA combined with HR T2WI for detecting NVC were 0.96 [95% confidence interval(CI): 0.92-0.98] and 0.92(95%CI: 0.74-0.98), respectively. The pooled positive likelihood ratio was 12.4(95%CI: 3.2-47.8), pooled negative likelihood ratio was 0.04(95%CI: 0.02-0.09), and pooled diagnostic odds ratio was 283(95%CI: 50-1620). The area under the receiver operating characteristic curve was 0.98(95%CI: 0.97-0.99). The studies showed no substantial heterogeneity(I2 = 0, Q = 0.001 P = 0.50).CONCLUSION Our results suggest that 3D TOF MRA combined with HR T2WI has excellent sensitivity and specificity for judging NVC in patients with TN or HFS. This method can be used as an effective tool for preoperative evaluation of MVD.
基金supported by the National Natural Science Foundation of China,No.61401308,61572063(both to XHW)the Natural Science Foundation of Beijing of China,No.L172055(to XHW)+3 种基金the Beijing Municipal Science&Technology Commission Research Fund of China,No.Z171100000417004(to XHW)the China Postdoctoral Fund,No.2018M631755(to XHW)the Special Fund for Improving Comprehensive Strength of Hebei University in the Midwest of China,No.801260201011(to XHW)the High-Level Talent Funding Project—Selective Post-doctoral Research Project Fund of Hebei Province of China,No.B2018003002(to XHW)
文摘The main symptom of patients with Alzheimer’s disease is cognitive dysfunction. Alzheimer’s disease is mainly diagnosed based on changes in brain structure. Functional connectivity reflects the synchrony of functional activities between non-adjacent brain regions, and changes in functional connectivity appear earlier than those in brain structure. In this study, we detected resting-state functional connectivity changes in patients with Alzheimer’s disease to provide reference evidence for disease prediction. Functional magnetic resonance imaging data from patients with Alzheimer’s disease were used to show whether particular white and gray matter areas had certain functional connectivity patterns and if these patterns changed with disease severity. In nine white and corresponding gray matter regions, correlations of normal cognition, early mild cognitive impairment, and late mild cognitive impairment with blood oxygen level-dependent signal time series were detected. Average correlation coefficient analysis indicated functional connectivity patterns between white and gray matter in the resting state of patients with Alzheimer’s disease. Functional connectivity pattern variation correlated with disease severity, with some regions having relatively strong or weak correlations. We found that the correlation coefficients of five regions were 0.3–0.5 in patients with normal cognition and 0–0.2 in those developing Alzheimer’s disease. Moreover, in the other four regions, the range increased to 0.45–0.7 with increasing cognitive impairment. In some white and gray matter areas, there were specific connectivity patterns. Changes in regional white and gray matter connectivity patterns may be used to predict Alzheimer’s disease;however, detailed information on specific connectivity patterns is needed. All study data were obtained from the Alzheimer’s Disease Neuroimaging Initiative Library of the Image and Data Archive Database.
文摘Gadoxetic acid- or gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid-enhanced magnetic resonance imaging(EOB-MRI) achieves excellent lesion detection and characterization for both hypervascular hepatocellular carcinoma(HCC) in arterial phase imagingand hypovascular early HCC(small well-differentiated HCC of the vaguely nodular type) in hepatobiliary phase imaging, and has become an indispensable imaging modality in the treatment of HCC. Early HCCs have been detected more frequently since the introduction of EOB-MRI into daily clinical practice. Early HCC is known to progress to conventional hypervascular HCC, and many risk factors have been identified for the hypervascularization of early HCC including the diameter of the tumor, presence of fat, and imaging findings of EOB-MRI. The rate of the development of hypervascular HCC was previously reported to be high in patients with chronic liver disease and early HCC. The presence of early HCC is regarded as a predictor for the recurrence of HCC following hepatic resection. On the other hand, although early HCC itself is currently not regarded as a target lesion for hepatic resection, early HCC at high risk of hypervascularity needs to be treated by local ablation therapy. If concomitant early HCC with progressed HCC is at high risk of hypervascularization and the functional liver reserve of a patient is sufficient, its simultaneous treatment at the time of hepatic resection for progressed HCC is recommended. Further studies on larger numbers of patients are needed before this strategy is adopted.
文摘Since its introduction in the 1970’s,magnetic resonance imaging(MRI)has become a standard imaging modality.With its broad and standardized application,it is firmly established in the clinical routine and an essential element in cardiovascular and abdominal imaging.In addition to sonography and computer tomography,MRI is a valuable tool for diagnosing cardiovascular and abdominal diseases,for determining disease severity,and for assessing therapeutic success.MRI techniques have improved over the last few decades,revealing not just morphologic information,but functional information about perfusion,diffusion and hemodynamics as well.Four-dimensional(4D)flow MRI,a time-resolved phase contrast-MRI with three-dimensional(3D)anatomic coverage and velocity encoding along all three flow directions has been used to comprehensively assess complex cardiovascular hemodynamics in multiple regions of the body.The technique enables visualization of 3D blood flow patterns and retrospective quantification of blood flow parameters in a region of interest.Over the last few years,4D flow MRI has been increasingly performed in the abdominal region.By applying different acceleration techniques,taking 4D flow MRI measurements has dropped to a reasonable scanning time of 8 to 12 min.These new developments have encouraged a growing number of patient studies in the literature validating the technique’s potential for enhanced evaluation of blood flow parameters within the liver’s complex vascular system.The purpose of this review article is to broaden our understanding of 4D flow MRI for the assessment of liver hemodynamics by providing insights into acquisition,data analysis,visualization and quantification.Furthermore,in this article we highlight its development,focussing on the clinical application of the technique.
文摘X-ray computed tomography(CT),ultrasonography(US)and radionuclide scanning are important clinical methods for evaluating morphology of the kidney.These modalities are also applicable for estimating kidney function with time lapse analysis using proper contrastmedia as may be necessary.In the case of US,it can estimate kidney function based on the measurement of blood flow using the Doppler effect.Formerly,magnetic resonance imaging(MRI)was an inappropriate diagnostic imaging technique for abdominal organs because of their respiratory displacements.However,MRI is now actively used for kidney as well as liver or other parenchymal organs,in tandem with the technological advances.Unlike unenhanced X-ray CT,"conventional"MRI can distinguish the border between cortex and medulla in T1 or T2 weighted images.It was known that the border blurred with decreasing kidney function.Moreover,several other particular imaging methods were introduced in recent years,and these could be called"functional"MRI.In this review,the following are discussed:functional MRI for chronic kidney disease,which include blood oxygenation level-dependent MRI for evaluation of hypoxia,diffusion-weighted imagingfor evaluation of fibrosis,diffusion tensor imaging for evaluation of microstructure,and arterial spin labeling to evaluate the amount of organ perfusion,accompanied with several related articles.The ultimate goal of functional MRI is to provide useful in vivo information repeatedly for daily medical treatment non-invasively.
文摘The purpose of this study was to demonstrate a simple and fast method for solving the time-dependent Bloch-McConnell equations describing the behavior of magnetization in magnetic resonance imaging (MRI) in the presence of multiple chemical exchange pools. First, the time-dependent Bloch- McConnell equations were reduced to a homogeneous linear differential equation, and then a simple equation was derived to solve it using a matrix operation and Kronecker tensor product. From these solutions, the longitudinal relaxation rate (R1ρ) and transverse relaxation rate in the rotating frame (R2ρ) and Z-spectra were obtained. As illustrative examples, the numerical solutions for linear and star-type three-pool chemical exchange models and linear, star- type, and kite-type four-pool chemical exchange models were presented. The effects of saturation time (ST) and radiofrequency irradiation power (ω1) on the chemical exchange saturation transfer (CEST) effect in these models were also investigated. Although R1ρ and R2ρ were not affected by the ST, the CEST effect observed in the Z-spectra increased and saturated with increasing ST. When ω1 was varied, the CEST effect increased with increasing ω1 in R1ρ, R2ρ, and Z-spectra. When ω1 was large, however, the spillover effect due to the direct saturation of bulk water protons also increased, suggesting that these parameters must be determined in consideration of both the CEST and spillover effects. Our method will be useful for analyzing the complex CEST contrast mechanism and for investigating the optimal conditions for CEST MRI in the presence of multiple chemical exchange pools.
文摘We describe common and less common diseases that can cause magnetic resonance signal abnormalities of middle cerebellar peduncles(MCP), offering a systematicapproach correlating imaging findings with clinical clues and pathologic mechanisms. Myelin abnormalities, different types of edema or neurodegenerative processes, can cause areas of abnormal T2 signal, variable enhancement, and patterns of diffusivity of MCP. Pathologies such as demyelinating disorders or certain neurodegenerative entities(e.g., multiple system atrophy or fragile X-associated tremor-ataxia syndrome) appear to have predilection for MCP. Careful evaluation of concomitant imaging findings in the brain or brainstem; and focused correlation with key clinical findings such as immunosuppression for progressive multifocal leukoencephalopahty; hypertension, post-transplant status or high dose chemotherapy for posterior reversible encephalopathy; electrolyte disorders for myelinolysis or suspected toxic-drug related encephalopathy; would yield an appropriate and accurate differential diagnosis in the majority of cases.
基金Projects(41204079,41504086)supported by the National Natural Science Foundation of ChinaProject(20160101281JC)supported by the Natural Science Foundation of Jilin Province,ChinaProjects(2016M590258,2015T80301)supported by the Postdoctoral Science Foundation of China
文摘Nano-volt magnetic resonance sounding(MRS) signals are sufficiently weak so that during the actual measurement, they are affected by environmental electromagnetic noise, leading to inaccuracy of the extracted characteristic parameters and hindering effective inverse interpretation. Considering the complexity and non-homogeneous spatial distribution of environmental noise and based on the theory of adaptive noise cancellation, a model system for noise cancellation using multi-reference coils was constructed to receive MRS signals. The feasibility of this system with theoretical calculation and experiments was analyzed and a modified sigmoid variable step size least mean square(SVSLMS) algorithm for noise cancellation was presented. The simulation results show that, the multi-reference coil method performs better than the single one on both signal-to-noise ratio(SNR) improvement and signal waveform optimization after filtering, under the condition of different noise correlations in the reference coils and primary detecting coils and different SNRs. In particular, when the noise correlation is poor and the SNR<0, the SNR can be improved by more than 8 dB after filtering with multi-reference coils. And the average fitting errors for initial amplitude and relaxation time are within 5%. Compared with the normalized least mean square(NLMS) algorithm and multichannel Wiener filter and processing field test data, the effectiveness of the proposed method is verified.
文摘Magnetic resonance imaging(MRI), magnetic resonance angiography(MRA) and magnetic resonance spectroscopy(MRS) are fundamental concepts used in modern medicine to improve health care. These concepts are based on the principle of nuclear magnetic resonance(NMR). Over the years, various laboratories around the world have applied different numerical techniques based on the Bloch NMR equations to solve specific problems in physics, biology, chemistry, engineering and medicine. The ultimate goal of any physician is to obtain maximum physical, biophysical, chemical and biological information on any tissue or cell under examination. This goal can be achieved by solving the Bloch NMR flow equations analytically. In this review, we present the basic principle of NMR/MRI in a way that can be easily understood by any researcher who needs an NMR concept to solve a specific medical problems. After a very brief history of the subject, a second order, non homogeneous, time-dependent differential equation derived from the Bloch NMR equation is presented. This equation has the basic intrinsic properties of MRI, MRA and MRS that can be extracted by means of classical and quantum mechanics for possible application in nanomedicine.
文摘BACKGROUND: Over 355 patients have received ortho- topic liver transplantation ( OLT) at this hospital since 1993. Preoperative imaging studies of both hepatic vessels and parenchyma in these recipients bettered surgical plan- ning or even precluded the necessity of surgery. Here we report our preliminary results of modified magnetic reso- nance angiography ( MRA ) using sensitivity encoding ( SENSE) through comparative study with conventional digital subtraction angiography (DSA) and CT arterial por- tography (CTAP). METHODS: Sixteen patients with suspected liver diseases were included in the study. All of them received both dy- namic MRI of the liver using SENSE and digital DSA with CTAP within a two-week interval. The four-phase MRA was reconstructed from source images of the coronal dy- namic study. The arterial phase of the modified MRA was compared with DSA in the evaluation of hepatic arteries and the portal phase compared with CT portography recon- structed from source images of CTAP. In dynamic study of the liver, a fixed dose (20 ml) of contrast medium and scan timing were used. RESULTS: The main branches and variations of the hepatic arterial system were well shown on the modified MRA, al- though the marginal branches of hepatic arteries were of poor quality. The figures of portal veins on MRA were as clear as or superior to those of CTAP. In addition, the su- prarenal inferior vena cava (IVC) was well demonstrated on MRA and/or non contrast-enhanced coronal balanced fast-field echo (b-FFE) scan sequence in most cases. MRI detected most parenchymal lesions of the liver and hemo- dynamics of these lesions could be evaluated on source ima- ges of the modified MRA. MRI/MRA also serendipitously revealed several extrahepatic disease entities or variations that were not found on DSA/CTAP. CONCLUSIONS: The modified MRA using SENSE is a cost-effective modality of examination for the demonstra- tion of the whole hepatic vascular system. Combined with MRI, it has the potential as a one-stop imaging modality in the preoperative evaluation in fields such as OLT.
文摘Parkinson's disease is a neurodegenerative disorder caused by loss of dopamine neurons in the substantia nigra pars compacta. Tremor, rigidity, and bradykinesia are the major symptoms of the disease. These motor impairments are often accompanied by affective and emotional dysfunctions which have been largely studied over the last decade. The aim of this study was to investigate emotional processing organization in the brain of patients with Parkinson's disease and to explore whether there are differences between recognition of different types of emotions in Parkinson's disease. We examined 18 patients with Parkinson's disease(8 men, 10 women) with no history of neurological or psychiatric comorbidities. All these patients underwent identical brain blood oxygenation level-dependent functional magnetic resonance imaging for emotion evaluation. Blood oxygenation level-dependent functional magnetic resonance imaging results revealed that the occipito-temporal cortices, insula, orbitofrontal cortex, basal ganglia, and parietal cortex which are involved in emotion processing, were activated during the functional control. Additionally, positive emotions activate larger volumes of the same anatomical entities than neutral and negative emotions. Results also revealed that Parkinson's disease associated with emotional disorders are increasingly recognized as disabling as classic motor symptoms. These findings help clinical physicians to recognize the emotional dysfunction of patients with Parkinson's disease.
基金Supported by The National Cancer Institute/National Institutes of HealthNo.1 R01 CA115895
文摘AIM: To investigate the merits of texture analysis on parametric maps derived from pharmacokinetic modeling with dynamic contrast-enhanced magnetic resonance imaging(DCE-MRI) as imaging biomarkers for the prediction of treatment response in patients with head and neck squamous cell carcinoma(HNSCC). METHODS: In this retrospective study,19 HNSCC patients underwent pre- and intra-treatment DCEMRI scans at a 1.5T MRI scanner. All patients had chemo-radiation treatment. Pharmacokinetic modeling was performed on the acquired DCE-MRI images,generating maps of volume transfer rate(Ktrans) and volume fraction of the extravascular extracellular space(ve). Image texture analysis was then employed on maps of Ktrans and ve,generating two texture measures: Energy(E) and homogeneity.RESULTS: No significant changes were found for the mean and standard deviation for Ktrans and ve between pre- and intra-treatment(P > 0.09). Texture analysis revealed that the imaging biomarker E of ve was significantly higher in intra-treatment scans,relative to pretreatment scans(P < 0.04). CONCLUSION: Chemo-radiation treatment in HNSCC significantly reduces the heterogeneity of tumors.