Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optim...Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optimization of CCWS often prioritizes short-term flow velocity optimization for minimizing power consumption,without considering fouling.However,low flow velocity promotes fouling.Therefore,it's crucial to balance fouling and energy/water conservation for optimal CCWS long-term operation.This study proposes a mixed-integer nonlinear programming(MINLP)model to achieve this goal.The model considers fouling in the pipeline,dynamic concentration cycle,and variable frequency drive to optimize the synergy between heat transfer,pressure drop,and fouling.By optimizing the concentration cycle of the CCWS,water conservation and fouling control can be achieved.The model can obtain the optimal operating parameters for different operation intervals,including the number of pumps,frequency,and valve local resistance coefficient.Sensitivity experiments on cycle and environmental temperature reveal that as the cycle increases,the marginal benefits of energy/water conservation decrease.In periods with minimal impact on fouling rate,energy/water conservation can be achieved by increasing the cycle while maintaining a low fouling rate.Overall,the proposed model has significant energy/water saving effects and can comprehensively optimize the CCWS through its incorporation of fouling and cycle optimization.展开更多
In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is o...In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
The main purpose of this paper is to design and model a water-pumping system using a submersible multi-stage centrifugal pump driven by a three-phase induction motor. The system is intended for pumping water to the su...The main purpose of this paper is to design and model a water-pumping system using a submersible multi-stage centrifugal pump driven by a three-phase induction motor. The system is intended for pumping water to the surface from a deep well using three power supply systems: a general network, a photo-voltaic (PV) system, and a PV system with a battery bank. These systems are used to compare two three-phase induction motors—namely, a motor with a drive and another one without a drive. The systems dynamic models are simulated in MATLAB/Simulink and the results compared with the manufacturer’s data for validation purposes. The simulation results generally show system dynamics and expected performance over a range of operation.展开更多
MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of mic...MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper.展开更多
Different guide vane structures will affect the flow inside the pump,and then affect the transformation of the pressure energy and kinetic energy,and change the velocity distribution of the pump outlet.In order to stu...Different guide vane structures will affect the flow inside the pump,and then affect the transformation of the pressure energy and kinetic energy,and change the velocity distribution of the pump outlet.In order to study the influence of long and short guide vanes on the water-jet pump,on the basis of conventional design,eight schemes of guide vane with different vertical heights were designed in the method of computational fluid dynamics for numerical calculation,the performance curve of water-jet pumps with different long and short guide vanes was obtained,and finally the influence of different guide vanes on hydraulic performance and internal flow was analyzed.The results show that all of schemes reducing the height of blade can improve the head and efficiency.In the schemes reducing the height on the shroud,the guide vanes that the height of the blade is equal to the height difference between hub and shroud in impeller have the highest head and efficiency.In all schemes decreasing the blade height,with the increase of the height difference,the velocity increases gradually and the distribution of turbulence kinetic energy becomes more reasonable in the guide vane outlet.The schemes reducing the height on the hub have more reasonable distribution of velocity and turbulence kinetic energy according to schemes reducing the height on the shroud.The guide vanes of long and short blades can be used to stagger the position of the diffusion flow generated by adjacent blades,which can reduce the effect of the velocity circulation and make the flow of the outlet position more stable.展开更多
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff...A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.展开更多
This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakis...This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakistan. The design, sizing, cost analysis and steady state analysis of the proposed systems were done in HOMER and dynamic analysis of the designed system with battery bank was performed in MATLAB/Simulink. The simulations performed in HOMER involved proper mapping of the loads which helped to evaluate the PV panel requirement, inverter rating, batteries (in case of battery based solution), modeling of water tank as a deferrable load (in case of solution based of water tank) and detailed cost analysis for a life time of 25 years. To verify the design of the solar water pumping system with battery bank, a simulation in MATLAB/Simulink for study of dynamic behavior of the overall system was performed which involved mathematical modeling of a PV panel, buckboost converter, inverter, battery bank and motor/pump, a perturb and observe maximum power point tracking algorithm based control system. Analysis was conducted based on the economic results that indicate designed solar water pumping system with water tank would be a cheaper solution as compared to solar water pumping system with a battery bank. This work can be taken as a case study for the understanding and optimized designs of solar water pumping system with battery bank and with cylindrical tank in Pakistani conditions.展开更多
In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbul...In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.展开更多
The article deals with modeling the tailing ponds influence on water resources. New technology using hydrocyclons of new design has been offered for additional purification of gold dressing mill wastewater. Laboratory...The article deals with modeling the tailing ponds influence on water resources. New technology using hydrocyclons of new design has been offered for additional purification of gold dressing mill wastewater. Laboratory and plant test have determined the optimal parameters of hydrocyclon. Introduction of new technology into system of water supply will prevent environment pollution and make it possible to process recoverable resources.展开更多
In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkaliza...In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater.展开更多
Using field hydrological data, the relationship between the mixing of salt water and fresh water and the tidal range/ high tidal level in the Changjiang (Yangtze) River estuary is discussed, and the transporting and c...Using field hydrological data, the relationship between the mixing of salt water and fresh water and the tidal range/ high tidal level in the Changjiang (Yangtze) River estuary is discussed, and the transporting and concentrating of suspended sediment in the estuary were also analysed in respect to the circulation, flocculation and stratified interface resulting from mixing.The calculation results by two-dimentional box model have confirmed the effects of the circulation on the concentrating of suspended sediment in the estuary. The conclusions derived from this work have deepened the understanding on the mixing in the Changjiang River estuary and are of significance in bo’th theory and practice.展开更多
The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters wer...The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%.展开更多
For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surf...For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surface defect detection,a lightweight detection method based on an improved YOLOv5s method is proposed to replace the traditional manual detection methods.In this method,the MobileNetV3 module replaces the backbone network of YOLOv5s,depth-separable convolution is introduced,the parameters and calculations are reduced,and CIoU_Loss is used as the loss function of the boundary box regression to improve its detection accuracy.A dataset of electronic pump shell defects is established,and the performance of the improved method is evaluated by comparing it with that of the original method.The results show that the parameters and FLOPs are reduced by 49.83%and 61.59%,respectively,compared with the original YOLOv5s model,and the detection accuracy is improved by 1.74%,which is an indication of the superiority of the improved method.To further verify the universality of the improved method,it is compared with the results using the original method on the PASCALVOC2007 dataset,which verifies that it yields better performance.In summary,the improved lightweight method can be used for the real-time detection of electronic water pump shell defects.展开更多
This paper made studies on the solar water pumping system in isolated area focusing on the case of Mibirizi village. The author made full interpretation of the construction of the solar pumping system and the general ...This paper made studies on the solar water pumping system in isolated area focusing on the case of Mibirizi village. The author made full interpretation of the construction of the solar pumping system and the general information of Rwanda, and then made full interpretation of the designing and calculating process of solar pumping system.展开更多
Hydrological and LADCP data from four experiments at sea (Semane 1999, 2000/1 2000/3, 2001) are used to describe the structure and circulation of Mediterranean Water in the Gulf of Cadiz. These data were gathered on m...Hydrological and LADCP data from four experiments at sea (Semane 1999, 2000/1 2000/3, 2001) are used to describe the structure and circulation of Mediterranean Water in the Gulf of Cadiz. These data were gathered on meridional sections along 8?20′W and 6?15′W and between these longitudes on a zonal section along 35?50′N. The mesoscale and the submesoscale structures (Mediterranean Water Undercurrents, meddies, cyclones) observed along these sections are characterized in terms of thermohaline properties and of velocity. The transports of mass and salt in each class of density (North Atlantic Central Water, Mediterranean Water, North Atlantic Deep Water) are computed with an inverse model. The model indicates a general eastward flux in the Central Water layer, and a westward flux in the Mediterranean Water layer, but there is also a horizontal recirculation and entrainment in these two layers, as well as strong transports associated with the meddy and cyclone found during Semane 1999.展开更多
基金Financial support from the National Natural Science Foundation of China (22022816 and 22078358)
文摘Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optimization of CCWS often prioritizes short-term flow velocity optimization for minimizing power consumption,without considering fouling.However,low flow velocity promotes fouling.Therefore,it's crucial to balance fouling and energy/water conservation for optimal CCWS long-term operation.This study proposes a mixed-integer nonlinear programming(MINLP)model to achieve this goal.The model considers fouling in the pipeline,dynamic concentration cycle,and variable frequency drive to optimize the synergy between heat transfer,pressure drop,and fouling.By optimizing the concentration cycle of the CCWS,water conservation and fouling control can be achieved.The model can obtain the optimal operating parameters for different operation intervals,including the number of pumps,frequency,and valve local resistance coefficient.Sensitivity experiments on cycle and environmental temperature reveal that as the cycle increases,the marginal benefits of energy/water conservation decrease.In periods with minimal impact on fouling rate,energy/water conservation can be achieved by increasing the cycle while maintaining a low fouling rate.Overall,the proposed model has significant energy/water saving effects and can comprehensively optimize the CCWS through its incorporation of fouling and cycle optimization.
文摘In the United Kingdom, means of meeting domestic heating is being electrified to decarbonise in effort to reduce the greenhouse gases emissions from the burning of natural gas. Therefore, the uptake of heat pumps is on the increase. The operation and working principle of heat pumps must be well understood in the investigations of their impacts on the grid and the grid assets, especially distribution transformers which could be overloaded due to higher peak load demand. This work develops an operational model of heat pumps as combined space heating and domestic hot water provider implemented in MATLAB. The developed operational model of heat pumps is adaptable and repeatable for different input parameters. The developed model is used to generate daily average demand profiles of heat pumps for a typical winter weekday and a typical summer weekday. The generated demand profiles of heat pumps by the developed model compared well with the demand profiles of heat pumps generated from actual field projects which are usually expensive and time-tasking.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.
文摘The main purpose of this paper is to design and model a water-pumping system using a submersible multi-stage centrifugal pump driven by a three-phase induction motor. The system is intended for pumping water to the surface from a deep well using three power supply systems: a general network, a photo-voltaic (PV) system, and a PV system with a battery bank. These systems are used to compare two three-phase induction motors—namely, a motor with a drive and another one without a drive. The systems dynamic models are simulated in MATLAB/Simulink and the results compared with the manufacturer’s data for validation purposes. The simulation results generally show system dynamics and expected performance over a range of operation.
文摘MIC is one of the main problems of circulating cooling water system. The direct economic loss by MIC is about 300 to 500 billion dollars. It is good to understand MIC in order to control MIC. Source and species of microorganisms was introduced firstly. There are three kinds of microorganisms in the system, including bacteria, fungi and algae. Species of these microorganisms are shown in the paper. Then, mechanisms of MIC are analysed. Although there is no universal mechanism of MIC, MIC is still mainly an electrochemical corrosion in nature. Meanwhile, the mechanisms on SRB and iron bacteria are introduced in details. At last, several methods of microorganisms control are put forward in the paper.
基金The Fundamental Research Funds for the Central Universities(JD2016XGKP1062)
文摘Different guide vane structures will affect the flow inside the pump,and then affect the transformation of the pressure energy and kinetic energy,and change the velocity distribution of the pump outlet.In order to study the influence of long and short guide vanes on the water-jet pump,on the basis of conventional design,eight schemes of guide vane with different vertical heights were designed in the method of computational fluid dynamics for numerical calculation,the performance curve of water-jet pumps with different long and short guide vanes was obtained,and finally the influence of different guide vanes on hydraulic performance and internal flow was analyzed.The results show that all of schemes reducing the height of blade can improve the head and efficiency.In the schemes reducing the height on the shroud,the guide vanes that the height of the blade is equal to the height difference between hub and shroud in impeller have the highest head and efficiency.In all schemes decreasing the blade height,with the increase of the height difference,the velocity increases gradually and the distribution of turbulence kinetic energy becomes more reasonable in the guide vane outlet.The schemes reducing the height on the hub have more reasonable distribution of velocity and turbulence kinetic energy according to schemes reducing the height on the shroud.The guide vanes of long and short blades can be used to stagger the position of the diffusion flow generated by adjacent blades,which can reduce the effect of the velocity circulation and make the flow of the outlet position more stable.
基金Supported by Hunan Science and Technology Office(06wk3023)National High Technology Research and Development Program of China(2006AA05Z229)Project-sponsored by SRFfor ROCS,SEM
文摘A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient.
文摘This paper is about the optimized design and analysis of two solar water pumping systems in which one of the systems is designed with a battery bank and other with a cylindrical water tank for a selected site in Pakistan. The design, sizing, cost analysis and steady state analysis of the proposed systems were done in HOMER and dynamic analysis of the designed system with battery bank was performed in MATLAB/Simulink. The simulations performed in HOMER involved proper mapping of the loads which helped to evaluate the PV panel requirement, inverter rating, batteries (in case of battery based solution), modeling of water tank as a deferrable load (in case of solution based of water tank) and detailed cost analysis for a life time of 25 years. To verify the design of the solar water pumping system with battery bank, a simulation in MATLAB/Simulink for study of dynamic behavior of the overall system was performed which involved mathematical modeling of a PV panel, buckboost converter, inverter, battery bank and motor/pump, a perturb and observe maximum power point tracking algorithm based control system. Analysis was conducted based on the economic results that indicate designed solar water pumping system with water tank would be a cheaper solution as compared to solar water pumping system with a battery bank. This work can be taken as a case study for the understanding and optimized designs of solar water pumping system with battery bank and with cylindrical tank in Pakistani conditions.
基金Project supported by the Priority Academic Development Program of Jiangsu Higher Education Institutions, ChinaProject(CXZZ12_0680) supported by Postgraduate Innovation Foundation of Jiangsu Province, ChinaProject(12JDG082) supported by the Advanced Talent Foundation of Jiangsu University, China
文摘In order to investigate the effect of sampling frequency and time on pressure fluctuations, the three-dimensional unsteady numerical simulations were conducted in a circulating water pump. Through comparison of turbulence models with hydraulic performance experiment, SST k-co model was confirmed to study the rational determination of sampling frequency and time better. The Fast Fourier Transform (FFT) technology was then adopted to process those fluctuating pressure signals obtained. On these bases, the characteristics of pressure fluctuations acting on the tongue were discussed. It is found that aliasing errors decrease at higher sampling frequency of 17 640 Hz, but not at a lower sampling frequency of 1 764 Hz. Correspondingly, an output frequency range ten-times wider is obtained at 17 640 Hz. Compared with 8R, when the sampling time is shorter, the amplitudes may be overvalued, and the frequencies and amplitudes of low-frequency fluctuations can not be well predicted. The frequencies at the tongue are in good agreement with the values calculated by formula and the frequency compositions less than the blade passing frequency are accurately predicted.
文摘The article deals with modeling the tailing ponds influence on water resources. New technology using hydrocyclons of new design has been offered for additional purification of gold dressing mill wastewater. Laboratory and plant test have determined the optimal parameters of hydrocyclon. Introduction of new technology into system of water supply will prevent environment pollution and make it possible to process recoverable resources.
文摘In order to solve the problems including pipe corrosion, scaling and microbial growth, which severely threat safe op-eration of circulating cooling water system, this paper proposes ion exchange softening and alkalization process to solve these problems and carries out a series of studies to study the feasibility of ion exchange softening and alkaliza-tion process in the simulation process of circulating cooling water system. The studies include product water quality of ion exchange softening and alkalization process, effect on the performance of carbon steel and brass, and the inhibition that suppresses microbial growth. The results indicate that ion exchange softening and alkalization process is feasible to prevent the circulating cooling water system from scaling, pipe corrosion, and microbial growth without any other chemicals. Thus circulating cooling water system can achieve zerodischarge of wastewater.
文摘Using field hydrological data, the relationship between the mixing of salt water and fresh water and the tidal range/ high tidal level in the Changjiang (Yangtze) River estuary is discussed, and the transporting and concentrating of suspended sediment in the estuary were also analysed in respect to the circulation, flocculation and stratified interface resulting from mixing.The calculation results by two-dimentional box model have confirmed the effects of the circulation on the concentrating of suspended sediment in the estuary. The conclusions derived from this work have deepened the understanding on the mixing in the Changjiang River estuary and are of significance in bo’th theory and practice.
基金financially supported by the National Natural Science Foundation of China (project 21077133)the Natural Foundation of Shandong Province and the Top Talent Project of China University of Petroleum (16RC17040003)
文摘The corrosion inhibition performance of co-immobilized lysozyme and lipase was investigated in a recirculating cooling water system. Four methods were carried out in co-immobilization, and the operating parameters were optimized by using the respond surface methodology(RSM). The corrosion inhibition performance of co-immobilized lipase and lysozyme was evaluated by weight loss measurements and electrochemical measurements. The results revealed that the optimal co-immobilization method should be the sequential immobilization of lysozyme and then lipase. The inhibition efficiency was 86.10% under the optimal co-immobilized conditions. Electrochemical data showed that co-immobilized lysozyme and lipase was a mixed-type inhibitor and the corrosion inhibition efficiency was 81%.
基金This work is supported by the Qing Lan Project of the Higher Education Institutions of Jiangsu Province,the 2022 Jiangsu Science and Technology Plan Special Fund(International Science and Technology Cooperation)(BZ2022029).
文摘For surface defects in electronic water pump shells,the manual detection efficiency is low,prone to misdetection and leak detection,and encounters problems,such as uncertainty.To improve the speed and accuracy of surface defect detection,a lightweight detection method based on an improved YOLOv5s method is proposed to replace the traditional manual detection methods.In this method,the MobileNetV3 module replaces the backbone network of YOLOv5s,depth-separable convolution is introduced,the parameters and calculations are reduced,and CIoU_Loss is used as the loss function of the boundary box regression to improve its detection accuracy.A dataset of electronic pump shell defects is established,and the performance of the improved method is evaluated by comparing it with that of the original method.The results show that the parameters and FLOPs are reduced by 49.83%and 61.59%,respectively,compared with the original YOLOv5s model,and the detection accuracy is improved by 1.74%,which is an indication of the superiority of the improved method.To further verify the universality of the improved method,it is compared with the results using the original method on the PASCALVOC2007 dataset,which verifies that it yields better performance.In summary,the improved lightweight method can be used for the real-time detection of electronic water pump shell defects.
文摘This paper made studies on the solar water pumping system in isolated area focusing on the case of Mibirizi village. The author made full interpretation of the construction of the solar pumping system and the general information of Rwanda, and then made full interpretation of the designing and calculating process of solar pumping system.
文摘Hydrological and LADCP data from four experiments at sea (Semane 1999, 2000/1 2000/3, 2001) are used to describe the structure and circulation of Mediterranean Water in the Gulf of Cadiz. These data were gathered on meridional sections along 8?20′W and 6?15′W and between these longitudes on a zonal section along 35?50′N. The mesoscale and the submesoscale structures (Mediterranean Water Undercurrents, meddies, cyclones) observed along these sections are characterized in terms of thermohaline properties and of velocity. The transports of mass and salt in each class of density (North Atlantic Central Water, Mediterranean Water, North Atlantic Deep Water) are computed with an inverse model. The model indicates a general eastward flux in the Central Water layer, and a westward flux in the Mediterranean Water layer, but there is also a horizontal recirculation and entrainment in these two layers, as well as strong transports associated with the meddy and cyclone found during Semane 1999.