期刊文献+
共找到15,846篇文章
< 1 2 250 >
每页显示 20 50 100
Noninvasive Assessment of Cardiac Index with Transesophageal Echocardiography in Patients Undergoing Mitral Valve Replacement: A Comparison between Determinations at the Mitral Valve and the Ascending Aorta 被引量:2
1
作者 Xiaoju Hu Hongwei Shi +2 位作者 Jinyan Yan Yali Ge Haiyan Wei 《Open Journal of Anesthesiology》 2013年第4期249-254,共6页
Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studi... Methods: Sixteen patients with American Society of Anesthesiologists status (ASA) II-III, age ≤ 70 yr, male or female, preoperatively NYHA II-III and EF ≥ 45%, scheduled for mitral valve replacement (MVR) were studied. Complete intravenous general anesthesia was used for induction and anesthesia maintenance. After anesthesia induction we put the TEE probe into the esophagus. The cardiac index was determined at three periods following MVR: T1 30 minutes later following cessation of bypass, T2 60 minutes after cessation of bypass, T3 90 minutes after cessation of bypass. Statistical analysis was made with the Bland and Altman method. Results: Ninety-six measurements were compared. The cardiac index values at the level of prosthesis mitral valve (CIMV) ranged from 1.3 to 5.5 L·min-1·m-2 (mean 2.6 ± 0.9). The Values of cardiac index at aortic valve (CIAA) ranged from 2.7 to8.8 L·min-1·m-2 (mean 4.9 ± 1.7). Bias was -2.3 L·min-1·m-2 and limits of agreement -5.6 to 1.0 L·min-1·m-2. Conclusion: During mitral valve replacement, doubtful correlations were observed between values of cardiac index at the mitral valve and the ascending aorta using TEE. 展开更多
关键词 CARDIAC Index CARDIAC Output transesophageal echocardiography MITRAL Valve REPLACEMENT Ascending AORTA
下载PDF
Assessment of left atrial appendage function by transesophageal echocardiography in patients two weeks after acute coronary syndromes
2
作者 Grzegorz Piotrowski Zenon Gawor +1 位作者 Dariusz Timler Jozef Tazbir 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2005年第4期198-201,共4页
Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate ... Background For many years in ischemic heart disease, ventricles rather than atria received attention so not much is known about left atrial function in left ventricular ischemia. Objective Our study aimed to evaluate left atrial appendage (LAA) function by means of biplane transesophageal echocardiography in patients ten days after acute coronary syndromes (ACS). Methods The study was performed on 16 adult patients (65.9±9.9 years old) in whom transesophageal echocardiography was done 10 days after ACS. The following left atrial appendage (LAA) planimetric parameters were analyzed: LAA transversal dimension, LAA longitudinal dimension,LAA maximal area, and LAA minimal area. LAA ejection fraction was calculated and analyzed. The following LAA Doppler parameters were analyzed: the peak LAA emptying and the peak LAA filling velocities. The control group consisted of 14 patients (43±14.6 years old) without cardiovascular diseases. Results Both LAA longitudinal dimension and LAA transversal dimension were significantly higher in patients with ACS than in control patients. The same was observed for LAA maximal area. Also LAA ejection fraction was higher in patients with ACS . LAA minimal area did not differ in the patients in either group. LAA peak emptying flow (LAAE) and LAA peak filling flow (LAAF) were significantly higher in patients of the study group than of the control group. Conclusion Our study shows that two weeks after acute coronary syndrome LAA as a reservoir as well as a pump works at a higher level than it does in the control group. (J Geriatr Cardiol 2005; 2(4):198-201) 展开更多
关键词 LEFT ATRIAL appendage acute CORONARY SYNDROMES transesophageal echocardiography
下载PDF
Surgical Resection of Mitral Valve Papillary Fibroelastoma: A Robot-Assisted, Minimally Invasive Approach with Three-Dimensional Transesophageal Echocardiography Imaging 被引量:1
3
作者 Crystal R. Bonnichsen Harold M. Burkhart +1 位作者 Kyle W. Klarich Rakesh M. Suri 《World Journal of Cardiovascular Surgery》 2012年第2期10-13,共4页
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e... Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy. 展开更多
关键词 PAPILLARY FIBROELASTOMA ROBOTIC Surgery Three-Dimensional transesophageal echocardiography
下载PDF
Role of intraoperative transesophageal echocardiography in coronary artery bypass grafting 被引量:1
4
作者 Xinchun Chen 《Journal of Nanjing Medical University》 2007年第1期1-7,共7页
Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means ... Transesophapeal echocardiography (TEE) can be used as a diagnostic tool during cardiac surgery to direct the surgical procedure and diagnose unanticipated problems. TEE has also been one of the most important means of monitoring myocardial ischemia dur- ing coronary artery bypas grafting procedures. The cardiac anesthesiologist can apply intraoperative TEE in evaluating coronary artery anatomy and aorta atherosclerosis, assessing diastolic left ventricular function and preload,measuring intracardiac pressure and cardiac output,detecting ischaemic mitral regurgitation,intracardiac air and pericardial effusion. 展开更多
关键词 transesophageal echocardiography coronary artery bypass grafting ANESTHESIA mycardial ischemia cardiac output regional wall motion abnormality
下载PDF
Upper gastrointestinal bleeding from a Mallory-Weiss tear associated with transesophageal echocardiography during successful cardiopulmonary resuscitation:A case report 被引量:1
5
作者 Miao-Miao Tang Deng-Feng Fang Bin Liu 《World Journal of Clinical Cases》 SCIE 2022年第9期2954-2960,共7页
BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59... BACKGROUND In recent years,it has been recognized that transesophageal echocardiography(TEE)is of great value in resuscitation of cardiac arrest.However,its safety has rarely been reported.CASE SUMMARY We present a 59-year-old male patient scheduled to undergo cardiac surgery for rheumatic heart disease.Upper gastrointestinal bleeding from a Mallory-Weiss tear appeared following cardiopulmonary resuscitation,TEE,and percutaneous cardiopulmonary bypass resuscitation when he suffered from aesthesia-related cardiac arrest.Gastrointestinal injury was diagnosed promptly and treated effectively.However,the exact etiology of gastrointestinal injury was unclear;the interaction of closed-chest cardiac massage and the application of TEE may be involved as a most possible mechanism of injury.CONCLUSION Serious complications should be considered when TEE is used in patients with special pathophysiological conditions. 展开更多
关键词 transesophageal echocardiography Upper gastrointestinal bleeding Cardiopulmonary resuscitation Mallory-Weiss tear Percutaneous cardiopulmonary bypass resuscitation Case report
下载PDF
Utility of Intraoperative Transesophageal Echocardiography in Pulmonary Thromboendarterectomy
6
作者 Katherine Chaparro Orozco David Mauricio +4 位作者 Abello Mauricio Osorio Javier Enrique Sarquis Tonny Alberto Barrero David Hincapie Myriam 《Open Journal of Anesthesiology》 2014年第3期63-67,共5页
Chronic thromboembolic pulmonary hypertension is one of the few forms of pulmonary hypertension that can be cured surgically, being the pulmonary trhomboendarterectomy (PTE) the therapeutic approach of choice, with su... Chronic thromboembolic pulmonary hypertension is one of the few forms of pulmonary hypertension that can be cured surgically, being the pulmonary trhomboendarterectomy (PTE) the therapeutic approach of choice, with survival as high as 75% to 90% at 5 years. Our case report focuses on the intraoperative use on the transesophageal echocardiography, which has proven to be of outmost utility in PTE surgery. Two cases of pulmonary thromboendarterectomy are described, in which transesophageal echocardiography was the key factor in the intraoperative management, indicating the initiation time of nitric oxide in case number one and contraindicating the advancement of the pulmonary artery catheter in case number two, due to a mobile thrombus located in the right ventricular outflow tract. 展开更多
关键词 Chronic THROMBOEMBOLIC PULMONARY HYPERTENSION PULMONARY THROMBOENDARTERECTOMY INTRAOPERATIVE echocardiography
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
7
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 Pulmonary veins Catheter ablation Atrial fibrillation transesophageal echocardiography Three-dimensional echocardiography
下载PDF
Role of real-time three-dimensional transesophageal echocardiography in mitral valve repair 被引量:1
8
作者 Cuizhen Pan~1 Xianhong Shu~1 Qiling Cao~2 Chunsheng Wang~1 Wenjun Ding~1 Haozhu Chen~1 1 Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai 200032, China, 2 Rush University Medical Center, Chicago, USA 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2008年第3期137-141,共5页
Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information... Background and objective Pre-operative assessment of mitral valve (MV) anatomy is essential to surgical design in patients undergoing MV repair.Although 2-dimensional (2D) echocardiography provides precise information regarding MV anatomy,RT-3D TEE could increase the understanding of MV apparatus and individual scallop identification.We aimed to investigate the value of RT- 3DTEE in MV repair.Methods RT-3DTEE was performed in six patients with mitral valve prolapse (MVP) by using Philips 1E33 with X7-2t probe.Preoperative RT-3DTEE studies were compared with surgical findings in patients undergoing surgical mitral valve repair,and quantitative evaluation was performed by QLab 6.0 software before and after surgical mitral valve repair.Results RT- 3DTEE could display dynamic morphology of MV,the location of prolapse,and spatial relation to the surrounding tissue.It could provide surgical views of the valves and the valvular apparatus.These results were consistent with surgical findings.The quantitative evaluation before and after surgical MV repair indicated that anterolateral to posteromedial diameter of annulus,anterior to posterior diameter of annulus,perimeter of annulus,and area of annulus in projection plane were significantly smaller after operation compared with those before operation (P【0.05).The length of posterior leaflet,the area of anterior and posterior leaflet,the maximal prolapse height,the volume of leaflet prolapse and the length of coaptation in projection plane were significantly reduced after operation (P【0. 05).Conclusion RT-3DTEE is a unique new modality for rapid and accurate evaluation ofmitral valve prolapse and mitral valve repair. 展开更多
关键词 echocardiography REAL-TIME transeophageal MITRAL VALVE REPAIR
下载PDF
The Role of Transesophageal Echocardiography for Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder 被引量:1
9
作者 许迪 孔祥清 +3 位作者 杨荣 盛燕辉 曹克将 陆凤翔 《Journal of Nanjing Medical University》 2003年第3期110-115,共6页
Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age... Objective: To evaluate of the role of transesophageal echocardiography (TEE)in percutaneous closure of atrial septal defects (ASD) with the Amplatzer septal occluder. Methods:Sixty- two patients (10 to 55 years of age) were selected for percutaneous closure of ASD bytrans-esophageal echocardiography, which was also used to monitor the procedure, to select theappropriate size of the Amplatzer device, to verify its position, and to access the immediateresults of the procedure. During the follow-up, transthoracic echocardiography (TTE) or TEE was usedto evaluate the presence and magnitude of residual shunt (RS), device position, and right cardiacchamber diameters. Results: The mean ASD diameter by TTE ([19. 1 +- 5. 8] mm) was significantlysmaller (P< 0. 001) than the stretched diameter of the ASD (25. 1 +- 6. 4) mm. There are nosignificant differences between the TEE -measured value (23. 5+_6. 2) mm and the stretched diameterof the ASD (P > 0. 05). Due to proper patient selection all procedures were successful. There wasimmediate and complete closure in 61/62 patients, only one patients had trivial residual shunt.Follow- up was performed using TTE or TEE right after operation, 1 d, 1 month, 3 months, 6 monthsand yearly thereafter. Ail, patients remain asymptomatic without any clinical or technical problems.Conclusion: With the aid of TEE, percutaneous closure of ASD can be performed successfully, safely,and effectively. 展开更多
关键词 transesophageal echocardiography atrial septal defects amplatzer septaloccluder
下载PDF
Feasibility of percutaneous closure of left atrial appendage under the guidance of transesophageal echocardiography without fluoroscopy
10
作者 Mengxuan Zou Guangzhi Zhao +6 位作者 Wenbin Ouyang Fengwen Zhang Bin Wen Yongquan Xie Cheng Wang Yao Liu Xiangbin Pan 《中国循环杂志》 CSCD 北大核心 2018年第S01期138-138,共1页
Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guid... Background In an effort to avoid x-ray and contrast agents for patients of atrial fibrillation(AF)with chronic kidney disease,we developed a method for transcatheter closure of left atrial appendage(LAA)under the guidance of transesophageal echocardiography(TEE)without fluoroscopy. 展开更多
关键词 ATRIAL FIBRILLATION LEFT ATRIAL appendage transesophageal echocardiography
下载PDF
Application of transesophageal echocardiography to aortic embolic stroke
11
作者 郭毅 姜昕 +2 位作者 陈实 张少文 李光展 《Chinese Medical Journal》 SCIE CAS CSCD 2002年第4期525-528,共4页
OBJECTIVES: To determine the relative value of transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in exploring the potential embolic source (PES) in heart and aortic arch and to study the ... OBJECTIVES: To determine the relative value of transesophageal echocardiography (TEE) and transthoracic echocardiography (TTE) in exploring the potential embolic source (PES) in heart and aortic arch and to study the clinical significance of aortic arch atherosclerosis (AAA). METHODS: Forty-nine patients with cerebral embolism were included in this study. TEE and TTE were used to evaluate the potential source of emboli in aortic arch, heart and duplex in the carotid artery. An atherosclerotic lesion of the aortic arch was defined as normal, mild plaque, moderate plaque, and protruding plaque or mobile plaque. RESULTS: Of the 49 patients, 31 (63%) patients showed evidence of AAA: 7 (14.1%) patients were mild, 9 (18.4%) were moderate and 15 (30.6%) were severe. In those 15 patients, 11 had neither severe ICAA nor heart disease. Thirty-three patients had internal carotid arterial atherosclerosis (ICAA). The potential sources of embolization of heart and aortic arch is 48.98% by TEE, but only 18.4% by TTE; 9 patients had heart disease. Age and ICAA were significantly correlated with AAA. CONCLUSION: At present, TEE is a better method for exploring atherosclerotic lesions in the thoracic aorta. AAA is an important potential source of cerebral embolic stroke. 展开更多
关键词 echocardiography transesophageal Adult Aged Aorta Thoracic Aortic Diseases ARTERIOSCLEROSIS Carotid Arteries Cerebrovascular Accident Comparative Study echocardiography Female Heart Diseases Humans Male Middle Aged MYOCARDIUM Research Support Non-U.S. Gov't Risk Factors
原文传递
Large Anterior Mediastinal Mass: Intraoperative Transesophageal Echocardiography Guided Evaluation and Management
12
作者 Kulbhushan Saini Sandeep Chauhan Manu Saini 《World Journal of Cardiovascular Surgery》 2021年第8期69-74,共6页
The authors report a case of Large Anterior mediastinal mass in which Transoesophageal Echocardiography (TEE) revealed a large mass that was compressing the right atrium, SVC, henceforth, TEE helped in guid</span&g... The authors report a case of Large Anterior mediastinal mass in which Transoesophageal Echocardiography (TEE) revealed a large mass that was compressing the right atrium, SVC, henceforth, TEE helped in guid</span><span style="font-size:10.0pt;font-family:"">ing</span><span style="font-size:10.0pt;font-family:""> aspiration and surgical resection of the cystic mass. Therefore, through this case report, <span>authors emphasize the importance of performing intraoperative real-time</span> TEE in the mediastinal mass. This imaging technique helps in visualizing the external compression of cardio-vascular structure and aid in their management, obviating the possibility of large vascular structures from being injured by the surgeon during intraoperative manipulation. 展开更多
关键词 Transoesophageal echocardiography Superior Vena Cava Trans Thoracic echocardiography Computed Tomography Right Atrium Inferior Vena Cava
下载PDF
Geometric comparison of the mitral and tricuspid valve annulus:Insights from three dimensional transesophageal echocardiography
13
作者 Amgad N Makaryus Haisam Ismail +1 位作者 John N Makaryus Dali Fan 《World Journal of Cardiology》 CAS 2017年第9期757-760,共4页
AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.MET... AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.METHODS Our retrospective cohort study examined the MVA and TVA in 49 patients by RT3 D TEE. MVA and TVA shape were examined by TEE. The MVA and TVA volume data set images were acquired in the mid esophageal 4-chamber view. The MVA and TVA were acquired separately, with optimization of each for the highest frame rate and image quality. The 3D shape of the annuli was reconstructed using the Philips~? Q lab, MVQ ver. 6.0 MVA model software. The end-systolic frame was used. The parameters measured and compared were annular area, circumference, high-low distances(height), anterolateralposterolateral(ALPM), and anteroposterior(AP) axes. RESULTS A total of 49 patients(mean age 61 ± 14 years, 45% males) were studied. The ALPM and the AP axes of the MVA and TVA are not significantly different. The ALPM axis of the MVA was 37.9 ± 6.4 mm and 38.0 ± 5.6 mm for the TVA(P = 0.70). The AP axis of the MVA was 34.8 ± 5.7 mm and 34.9 ± 6.2 mm for the TVA(P = 0.90). The MVA and the TVA had similar circumference and area. The circumference of the MVA was 127.9 ± 16.8 mm and 125.92 ± 16.12 mm for the TVA(P = 0.23). The area of the MVA was 1103.7 ± 307.8 mm^2 and 1131.7 ± 302.0 mm^2 for the TVA(P = 0.41). The MVA and TVA are similar oval structures, but with significantly different heights. The ALPM/AP ratio for the MVA was 1.08 ± 0.33 and 1.09 ± 0.28 for the TVA(P < 0.001). The height for the MVA and TVA was 9.23 ± 2.11 mm and 4.37 ± 1.48 mm, respectively(P < 0.0001). CONCLUSION RT3 D TEE plays an unprecedented role in the management of valvular heart disease. The specific and exclusive shape of the MVA and TVA was revealed in our study of patients studied. Moreover, the intricate codependence of the MVA and the TVA depends on their distinctive shapes. This realization seen from our study will allow us to better understand the role valvular disease plays in disease states such as hypertrophic cardiomyopathy and pulmonary hypertension. 展开更多
关键词 Mitral valve annulus Tricuspid valve annulus Three dimensional imaging Real time three-dimensional transesophageal echocardiography
下载PDF
Research and Application of Transnasal Transesophageal Echocardiography Probe 被引量:1
14
作者 王蕾 张静 +4 位作者 郑少萍 贺林 王静 王新房 谢明星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2017年第5期782-786,共5页
The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed... The intubation of conventional transesophageal echocardiography(TEE) probes into patients causes serious esophagus irritation, and thus the use of TEE probes in pediatric practice is limited. In this study, we aimed at the development of a special probe which could be inserted through the nasopharyngeal cavity into the esophagus to obtain the same high-quality echocardiography images as those obtained by conventional TEE and improve patients' experience. During the examination, the patients felt relaxed for a longer time and cooperated with the sonographers in the process of cardiac catheterization conducted in the surgery room or the intensive care unit(ICU), resulting in improved accuracy of the diagnosis and timely administration of appropriate treatment. Two years ago, Prof. Xin-fang WANG put theories into practice by inserting the probe through the nasal cavity and pharynx into the esophagus of volunteers to successfully detect the heart and great vessels at the retrocardiac space. Later, Prof. Ming-xing XIE performed the transnasal TEE examination in 12 atrial septal defect(ASD) patients and proved the safety and reliability of this method, which could become a new way for clinical diagnosis and treatment. 展开更多
关键词 transesophageal echocardiography atrial septal defect transthoracic echocardiography
下载PDF
A cadaveric model for transesophageal echocardiography transducer placement training: A pilot study
15
作者 Ryan W.Horton Kian R.Niknam +3 位作者 Viveta Lobo Kathryn H.Pade Drew Jones Kenton L.Anderson 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第1期18-22,共5页
BACKGROUND: Transesophageal echocardiography(TEE) is used in the emergency department to guide resuscitation during cardiac arrest. Insertion of a TEE transducer requires manual skill and experience, yet in some resid... BACKGROUND: Transesophageal echocardiography(TEE) is used in the emergency department to guide resuscitation during cardiac arrest. Insertion of a TEE transducer requires manual skill and experience, yet in some residency programs cardiac arrest is uncommon, so some physicians may lack the means to acquire the manual skills to perform TEE in clinical practice. For other infrequently performed procedural skills, simulation models are used. However, there is currently no model that adequately simulates TEE transducer insertion. The aim of this study is to evaluate the feasibility and efficacy of using a cadaveric model to teach TEE transducer placement among novice users.METHODS: A convenience sample of emergency medicine residents was enrolled during a procedure education session using cadavers as tissue models. A pre-session assessment was used to determine prior knowledge and confidence regarding TEE manipulation. Participants subsequently attended a didactic and hands-on education session on TEE placement. All participants practised placing the TEE transducer until they were able to pass a standardized assessment of technical skill(SATS). After the educational session, participants completed a post-session assessment. RESULTS: Twenty-five residents participated in the training session. Mean assessment of knowledge improved from 6.2/10 to 8.7/10(95% confidence interval [CI] of knowledge difference 1.6–3.2, P<0.001) and confidence improved from 1.6/5 to 3.1/5(95% CI of confidence difference 1.1–2.0, P<0.001). There was no relationship between training level and the delta in knowledge or confidence.CONCLUSIONS: In this pilot study, the use of a cadaveric model to teach TEE transducer placement methods among novice users is feasible and improves both TEE manipulation knowledge and confidence levels. 展开更多
关键词 Cardiopulmonary resuscitation echocardiography EDUCATION Simulation
下载PDF
Is transesophageal echocardiography needed for evaluating tissue-based transient ischemic attack?
16
作者 Mohamed Al-Khaled Bjorn Scheef Toralf Brüning 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第7期1212-1215,共4页
Transient ischemic attack(TIA) is a warning signal for stroke.A comprehensive evaluation of TIA may reduce the risk for subsequent stroke.Data on the findings of cardiac evaluation with transesophageal echocardiogra... Transient ischemic attack(TIA) is a warning signal for stroke.A comprehensive evaluation of TIA may reduce the risk for subsequent stroke.Data on the findings of cardiac evaluation with transesophageal echocardiography(TEE) in patients with TIA are sparse.Our aims were to determine the frequency of TEE performance and to investigate the findings of TEE in patients with TIA based on the new definition of TIA(i.e.,transient neurological symptoms without evidence of infarction).During a 4-year period(2011–2014),1071 patients(mean age,70 ± 13 years;female,49.7%) with TIA were included in a prospective study and evaluated.Of 1071 consecutive patients suffering from TIA,288 patients(27%) underwent TEE.The median time between admission and TEE was 6 days.Patients with TIA who were evaluated by TEE were younger(67 vs.71 years,P 〈 0.001) than those who were not evaluated by TEE.They had a higher rate of sensibility disturbance as a TIA symptom(39% vs.31%,P = 0.012) but a lower rate of previous stroke(15% vs.25%,P = 0.001) and atrial fibrillation(2% vs.21%,P 〈 0.001) than those who did not.Foramen ovale was detected in 71 patients(25.7%),atrial septal aneurysm in 13 patients(4.6%),and severe atherosclerotic plaques(grade 4 and 5) in the aortic arch in 25 patients(8.7%).One patient(0.3%) had a fibroma detected by TEE.In 17 of the 288 patients(6%) who underwent TEE,the indication for anticoagulation therapy was based on the TEE results,and 1 patient with fibroma underwent heart surgery.During hospitalization,7 patients experienced a subsequent stroke,and 27 patients had a recurrent TIA.At 3 months following discharge,the rates of readmission,stroke,recurrent TIA,and death were 19%,2.7%,4.2%,and 1.6%,respectively.The rates of mortality(0.9% vs.1.8%,P = 0.7),stroke risk(1.9% vs.3.0%,P = 0.8),and recurrent TIA(5.0% vs.3.9%,P = 0.8) were similar in patients who underwent TEE and in those who did not.Performing TEE in patients with tissue-based TIA is helpful in detecting cardiac sources for embolism and may indicate for anticoagulation. 展开更多
关键词 transesophageal echocardiography transient ischemic stroke anticoagulation management therapy change
下载PDF
CLINICAL APPLICATION OF OMNIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY
17
作者 王国干 刘汉英 +1 位作者 孟宪强 程克正 《Chinese Medical Sciences Journal》 CAS CSCD 1996年第3期177-179,共3页
One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane tran... One hundred and twenty-four patients with heart disease(75 cases of rheumatic heart disease,26 cases of congenital heart disease,13 cases of aortic disease and 10 cases of other disease)were examined by Omniplane transesophageal echocardiography(TEE).The result showed that Omniplane TEE transducer can be rotated from 0°to 180°in probe and had the advantages of broader scope,obtaining more information,less stimulation to esophagus and easy to manipulate.It suggests that Omniplane TEE is a efficient technique in clinical diagnosis and can be extensively used in the future. 展开更多
关键词 transesophageal echocardiography echocardiography
下载PDF
Effects of sevoflurane on left ventricular function by speckletracking echocardiography in coronary bypass patients: A randomized trial
18
作者 Chanjuan Gong Xiaokai Zhou +3 位作者 Yin Fang Yanjuan Zhang Linjia Zhu Zhengnian Ding 《The Journal of Biomedical Research》 CAS CSCD 2024年第1期76-86,共11页
The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to ass... The present study aimed to dynamically observe the segmental and global myocardial movements of the left ventricle during coronary artery bypass grafting by transesophageal speckle-tracking echocardiography,and to assess the effect of sevoflurane on cardiac function.Sixty-four patients scheduled for the off-pump coronary artery bypass grafting were randomly divided into a sevoflurane-based anesthesia(AS)group and a propofolbased total intravenous anesthesia(AA)group.The AS group demonstrated a higher absolute value of left ventricular global longitudinal strain than that of the AA group at both T1(after harvesting all grafts and before coronary anastomosis)and T_(2)(30 min after completing all coronary anastomoses)(P<0.05).Moreover,strain improvement in the segment with the highest preoperative strain was significantly reduced in the AS group,compared with the AA group at both T1 and T_(2)(P<0.01).The flow of the left internal mammary artery-left anterior descending artery graft was superior,and the postoperative concentration of troponin T decreased rapidly in the AS group,compared with the AA group(P<0.05).Compared with total intravenous anesthesia,sevoflurane resulted in a significantly higher global longitudinal strain,stroke volume,and cardiac output.Sevoflurane also led to an amelioration in the condition of the arterial graft.Furthermore,sevoflurane significantly reduced strain improvement in the segmental myocardium with a high preoperative strain value.The findings need to be replicated in larger studies. 展开更多
关键词 coronary artery bypass grafting speckle-tracking echocardiography SEVOFLURANE transesophageal echocardiography
下载PDF
Evaluate of transesophageal echocardiography during lung transplantation
19
作者 吴雅峰 《外科研究与新技术》 2011年第3期158-158,共1页
Objective To investigate the clinical value of transesophageal echocardiography during the lung transplantation. Methods From August 2005 to August 2009, 19 patients with advanced lung diseases received lung transplan... Objective To investigate the clinical value of transesophageal echocardiography during the lung transplantation. Methods From August 2005 to August 2009, 19 patients with advanced lung diseases received lung transplantation. The average age was (48. 35 ± 13. 04) years. The echocardiographic probe was placed in patient’ s esophagus before surgery. The left and right 展开更多
关键词 LUNG Evaluate of transesophageal echocardiography during lung transplantation
下载PDF
Evaluation of Left Ventricular Function after Percutaneous Recanalization of Chronic Coronary Occlusions: The Role of Two-Dimensional Speckle Tracking Echocardiography 被引量:11
20
作者 Ahmed Emara Shady Zahran Neveen I. Samy 《World Journal of Cardiovascular Diseases》 2019年第12期899-914,共16页
Background: The recanalization of a chronic total coronary occlusion is the possible way to improve left ventricular (LV) function through the recovery of hibernating myocardium. Aim: The aim of this study is to evalu... Background: The recanalization of a chronic total coronary occlusion is the possible way to improve left ventricular (LV) function through the recovery of hibernating myocardium. Aim: The aim of this study is to evaluate the role of 2D speckle tracking in evaluation of the left ventricular (LV) systolic function in chronic total occlusion (CTO) patients before and at 1 day as well as 3 months after percutaneous coronary intervention (PCI). Patients and Methods: A prospective observational study included 40 patients diagnosed with coronary angiography to have a chronic total occlusion. Percutaneous coronary revascularization was performed according to standard practices with the femoral approach. Conventional 2D echocardiography was used to assess LV functions and wall motion abnormalities scoring index (WMAI). Using speckle-tracking echocardiography was to measure global longitudinal strain (GLS) and. Follow-up of patients was done at day 1 and 3 months later after PCI. Results: Forty patients were included in this study, with a mean age of 58.55 ± 7.98 years. GLS and WMAI difference at baseline and follow-up shows a positive correlation with left ventricular ejection fraction (LVEF) changes at baseline and follow-up (p Conclusion: The results of this study provide evidence to support the clinical use of 2D-STE to monitor the early changes of LV function. In patients undergoing CTO revascularization, change in GLS was more sensitive predictors for LV function improvement at 3-month follow-up. 展开更多
关键词 CHRONIC Total OCCLUSIONS Left Ventricular Function PERCUTANEOUS Coronary Intervention EJECTION Fraction Speckle Tracking echocardiography
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部