An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model ...An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model has been developed and an optimization methodhas been introduced into computation for designing the electrostatic focusing field of the imagingsystem.展开更多
Based on the diffraction theory model for hot-image formation, the evolution of hot-images induced by multiscatterers located in the same plane perpendicular to the propagation axis is numerically simulated. The simul...Based on the diffraction theory model for hot-image formation, the evolution of hot-images induced by multiscatterers located in the same plane perpendicular to the propagation axis is numerically simulated. The simulation results show that hot-images induced by coplanar multi-scatterers are also coplanar no matter whether they exist simultaneously or severally. However, if they exist simultaneously the peak intensity of the primary hot-images is weaker than if they exist severally. The unequal competition for energy between the scattered beams from the scatterers leads to the fact that part of the corresponding hot-images are relatively enhanced and the others are restrained. The results show that the hot-images of certain scatterers become stronger when any of these parameters, i.e. amplitude modulation coefficient, phase modulation coefficient and size of the surrounding scatterer, decrease.展开更多
Optical endoscopy has become an essential diagnostic and therapeutic approach in modern biomedicine for directly observing organs and tissues deep inside the human body,enabling non-invasive,rapid diagnosis and treatm...Optical endoscopy has become an essential diagnostic and therapeutic approach in modern biomedicine for directly observing organs and tissues deep inside the human body,enabling non-invasive,rapid diagnosis and treatment.Optical fiber endoscopy is highly competitive among various endoscopic imaging techniques due to its high flexibility,compact structure,excellent resolution,and resistance to electromagnetic interference.Over the past decade,endoscopes based on a single multimode optical fiber(MMF)have attracted widespread research interest due to their potential to significantly reduce the footprint of optical fiber endoscopes and enhance imaging capabilities.In comparison with other imaging principles of MMF endoscopes,the scanning imaging method based on the wavefront shaping technique is highly developed and provides benefits including excellent imaging contrast,broad applicability to complex imaging scenarios,and good compatibility with various well-established scanning imaging modalities.In this review,various technical routes to achieve light focusing through MMF and procedures to conduct the scanning imaging of MMF endoscopes are introduced.The advancements in imaging performance enhancements,integrations of various imaging modalities with MMF scanning endoscopes,and applications are summarized.Challenges specific to this endoscopic imaging technology are analyzed,and potential remedies and avenues for future developments are discussed.展开更多
文摘An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model has been developed and an optimization methodhas been introduced into computation for designing the electrostatic focusing field of the imagingsystem.
基金supported by the Joint Foundation of National Natural Science Foundation of China and the Science Foundation of the Chinese Academy of Engineering Physics,China(Grant No 10576023)the Doctorate Foundation of Northwestern Polytechnical University,China(Grant No CX200714)
文摘Based on the diffraction theory model for hot-image formation, the evolution of hot-images induced by multiscatterers located in the same plane perpendicular to the propagation axis is numerically simulated. The simulation results show that hot-images induced by coplanar multi-scatterers are also coplanar no matter whether they exist simultaneously or severally. However, if they exist simultaneously the peak intensity of the primary hot-images is weaker than if they exist severally. The unequal competition for energy between the scattered beams from the scatterers leads to the fact that part of the corresponding hot-images are relatively enhanced and the others are restrained. The results show that the hot-images of certain scatterers become stronger when any of these parameters, i.e. amplitude modulation coefficient, phase modulation coefficient and size of the surrounding scatterer, decrease.
基金supported by National Natural Science Foundation of China(62135007 and 61925502).
文摘Optical endoscopy has become an essential diagnostic and therapeutic approach in modern biomedicine for directly observing organs and tissues deep inside the human body,enabling non-invasive,rapid diagnosis and treatment.Optical fiber endoscopy is highly competitive among various endoscopic imaging techniques due to its high flexibility,compact structure,excellent resolution,and resistance to electromagnetic interference.Over the past decade,endoscopes based on a single multimode optical fiber(MMF)have attracted widespread research interest due to their potential to significantly reduce the footprint of optical fiber endoscopes and enhance imaging capabilities.In comparison with other imaging principles of MMF endoscopes,the scanning imaging method based on the wavefront shaping technique is highly developed and provides benefits including excellent imaging contrast,broad applicability to complex imaging scenarios,and good compatibility with various well-established scanning imaging modalities.In this review,various technical routes to achieve light focusing through MMF and procedures to conduct the scanning imaging of MMF endoscopes are introduced.The advancements in imaging performance enhancements,integrations of various imaging modalities with MMF scanning endoscopes,and applications are summarized.Challenges specific to this endoscopic imaging technology are analyzed,and potential remedies and avenues for future developments are discussed.