That the diseases in the interior can be treated at the exterior is one of the therapeutic methods of traditional Chinese medicine. Pretty good results has been obtained in treating the patients of angina pectoris wit...That the diseases in the interior can be treated at the exterior is one of the therapeutic methods of traditional Chinese medicine. Pretty good results has been obtained in treating the patients of angina pectoris with medicinal plaster fixed at acupoints. This is reported as follows.展开更多
Effects of a minor Ca addition on microstructural stability and dynamic restoration behavior of AlMg5 during hot deformation were investigated.They were studied using scanning electron microscopy(SEM),differential sca...Effects of a minor Ca addition on microstructural stability and dynamic restoration behavior of AlMg5 during hot deformation were investigated.They were studied using scanning electron microscopy(SEM),differential scanning calorimetry(DSC),electron backscatter diffraction(EBSD) analyses and transmission electron microscopy(TEM).JMatPro package was used for simulation of the solidification path of the alloys.The results show that the addition of Ca does not affect the microstructure and hot compression behavior of the as-cast samples.However,it prevents the drastic grain growth during homogenization.It is found that coarse grains of Ca-free alloy promote the dynamic recovery and slow down the dynamic recrystallization during hot compression.Also,the particle stimulated nucleation is suggested as the main nucleation mechanism of new recrystallized grains for hot compressed Ca-free alloy On the other hand,the microstructure of the hot compressed Ca-added alloy is greatly affected by the presence of Al4Ca intermetallics.The formation of Al4Ca phase is predicted by JMatPro and revealed by DSC,SEM and TEM studies.Finally,it is found that the presence of Al4Ca precipitates on the grain boundaries of Ca-added alloy prevents the growth of a(Al) by Zener pinning effect and results in the stability of microstructure during homogenization.展开更多
The pressure increasing process within a twin screw multiphase pump, under the condition of high gas volume fractions (GVFs), induces large temperature and pressure changes that cause the rotors to deform. Rotor defor...The pressure increasing process within a twin screw multiphase pump, under the condition of high gas volume fractions (GVFs), induces large temperature and pressure changes that cause the rotors to deform. Rotor deformations heavily influence the backflow of the multiphase fluid through clearances within the twin screw multiphase pump and these deformations may even lead to pump failures. An accurate temperature and pressure distribution on the screw rotors need be obtained before the deformation analysis can be carried out. By means of small temperature and pressure sensors embedded into the groove at the root of the rotors, the temperatures of 12 points on the rotors and the pressure distributions of a twin screw multiphase pump under high GVFs conditions were recorded. Temperature test results were adopted to perform a heat transfer analysis for determining the temperature distribution on the screw rotors. Then deformation analyses, including thermal deformation, force deformation, and total deformation, were conducted according to the pressure and temperature distributions. Deformation analysis for different materials was also conducted under the same boundary conditions. A material was suggested for the manufacturing of rotors in a twin screw multiphase pump under the condition of high gas volume fractions.展开更多
Purpose: The aim of this study was to investigate the incidence of Z-effect after dual lag screw intramedullary nailing systems and risk factors contributing to this effect. We hypothesized that long nails provide mo...Purpose: The aim of this study was to investigate the incidence of Z-effect after dual lag screw intramedullary nailing systems and risk factors contributing to this effect. We hypothesized that long nails provide more neck strength due to a longer lever than short nails and are therefore less likely to develop a misbalance of a higher head compressive strength than neck compressive strength, Methods: In this retrospective cohort study 103 patients treated operatively with a dual lag screw intramedullary nailing device for (sub)trochanteric hip fracture were included, We analysed patient charts regarding patient and operation characteristics. Furthermore we conducted radiologic mea- surements within the 2-year follow-up period to investigate the quality of fracture fixation, implant failure and predictors for Z-effect. The re-operation risk was investigated with multivariate regression analysis, Results: The incidence of (reversed) Z-effect in this study was 9% (n 80); 6 out of 7 Z-effects occurred in the short nail group, which was not significant. Patients who were treated with a long nail had a significant larger number of complications in comparison with the short nail group (median 2 vs 0,5, p = 0.001). The long nail group received more often erythrocytes blood transfusions (82% vs 31%, p 〈 0.01) and had a longer hospital stay (13 vs 21 days, p 〈 0.05). Migration of lag screws (p 〈0.05) and unstable fracture type (p 〈 0.05), were risk factors for re-operation. The re-operation rate within 2 year after surgery was 21%, of which one fourth was due to a Z-effect. Conclusion: The nail length was not associated with the development of a Z-effect. Migration of lag screws after intramedullary nailing is common and a risk factor for re-operation.展开更多
Purpose: Cerclage wire application has emerged as a potential therapeutic adjunct to intramedullary nailing for subtrochanteric fractures. But its popularity is plagued by the concern of possible negative effect on f...Purpose: Cerclage wire application has emerged as a potential therapeutic adjunct to intramedullary nailing for subtrochanteric fractures. But its popularity is plagued by the concern of possible negative effect on fracture zone biology. This study was intended to analyze the clinico-radiological outcome and complications associated with cerclage wire application. Methods: Retrospective analysis was performed on all the subtrochanteric fractures operated with intramedullary nailing between January 2012 and January 2016. After exclusion, 48 patients were available with an average follow-up of 20.8 months. Long oblique, spiral, spiral wedge or comminuted fracture configurations with butterfly fragments were particularly considered for cerclage wire appli- cation, which was employed by percutaneous cerclage passer in 21 patients. Assessment was done in terms of operation time, blood loss, quality of reduction, neck-shaft angle, follow-up redisplacement, union time, complications, and final functional evaluation by Merle d'Aubigne'-Postel score. Results: Average operation time and blood loss were significantly higher in cerclage group (p 〈 0.05). However, cerclage use substantially improved quality of reduction in terms of maximum cortical displacement (p = 0.003) and fracture angulation (p - 0.045); anatomical reduction was achieved in 95.23% of cases as compared to 74.07% without cerclage. Union time was shorter, although not statis- tically different (p - 0.208), in cerclage group. Four patients in non-cerclage group developed non-union, 2 of them had nail breakage. No infection or any other implant related complications were reported with cerclage use. Conclusion: Minimally-invasive cerclage wire application has proved to be beneficial for anatomical reconstruction in difficult subtrochanteric fractures, whenever applicable, without any harmful effect on fracture biology.展开更多
Vesicovaginal fistula (VVF) may be caused by prolonged obstructed labor, gynecologic, urologic, or other pelvic surgery, malignancy, radiation, infection and trauma. Here we report a case of VVF caused by nail penet...Vesicovaginal fistula (VVF) may be caused by prolonged obstructed labor, gynecologic, urologic, or other pelvic surgery, malignancy, radiation, infection and trauma. Here we report a case of VVF caused by nail penetrating trauma in a young woman with genital bleeding after first intercourse. This is a rare etiology of VVF. We also explain the operative technique used to repair the fistula.展开更多
Objective: To treat injury of the lower cervical spine C6 to C7 with cervical lateral mass plates and T1 pedicle screws through posterior approach. Methods: The data of 8 patients with lower cervical spine C6 or C7 in...Objective: To treat injury of the lower cervical spine C6 to C7 with cervical lateral mass plates and T1 pedicle screws through posterior approach. Methods: The data of 8 patients with lower cervical spine C6 or C7 injury (6 patients with fracture and dislocation in C6 and C7 and 2 with fracture in C7) were analyzed retrospectively in this study. For the preoperative American Spinal Injury Association (ASIA) classification, Grade C was found in 3 cases and Grade D in 5 cases. Screws were placed on the lateral masses and the first thoracic pedicle with Margerl technique. Lamina or facet bone allografting was used to achieve a long-term stability. Results: All the 8 patients were followed up for 5-37 months (mean: 15 months). No operative death occurred. There were no examples of aggravation of spinal cord injury or vertebral artery injury, cerebrospinal fluid leak, nerve roots injury, screw malposition or back-out, loose of alignment or implant failure. Clinical symptoms and ASIA classification were improved in all the patients. Postoperative MRI scanning confirmed the satisfactory screw placement in all the cases. Conclusions: Lateral mass plates and pedicle screws through posterior approach are safe and beneficial for patients with lower cervical spine C6 or C7 injury.展开更多
Ternary Ⅰ–Ⅲ–Ⅵquantum dots(QDs) of chalcopyrite semiconductors exhibit excellent optical properties in solar cells. In this study, ternary chalcopyrite CuGaS2nanocrystals(2–5 nm) were one-pot anchored on TiO2...Ternary Ⅰ–Ⅲ–Ⅵquantum dots(QDs) of chalcopyrite semiconductors exhibit excellent optical properties in solar cells. In this study, ternary chalcopyrite CuGaS2nanocrystals(2–5 nm) were one-pot anchored on TiO2nanoparticles(TiO2@CGS) without any long ligand. The solar cell with TiO2@CuGaS2/N719 has a power conversion efficiency of7.4%, which is 23% higher than that of monosensitized dye solar cell. Anchoring CuGaS2 QDs on semiconductor nanoparticles to form QDs/dye co-sensitized solar cells is a promising and feasible approach to enhance light absorption,charge carrier generation as well as to facilitate electron injection comparing to conventional mono-dye sensitized solar cells.展开更多
文摘That the diseases in the interior can be treated at the exterior is one of the therapeutic methods of traditional Chinese medicine. Pretty good results has been obtained in treating the patients of angina pectoris with medicinal plaster fixed at acupoints. This is reported as follows.
基金supported by the research project on aluminum alloys (Grant No. PJE18070 of Korea Institute of Industrial Technology), which is funded by Ministry of Trade, Industry and Energy, Korea
文摘Effects of a minor Ca addition on microstructural stability and dynamic restoration behavior of AlMg5 during hot deformation were investigated.They were studied using scanning electron microscopy(SEM),differential scanning calorimetry(DSC),electron backscatter diffraction(EBSD) analyses and transmission electron microscopy(TEM).JMatPro package was used for simulation of the solidification path of the alloys.The results show that the addition of Ca does not affect the microstructure and hot compression behavior of the as-cast samples.However,it prevents the drastic grain growth during homogenization.It is found that coarse grains of Ca-free alloy promote the dynamic recovery and slow down the dynamic recrystallization during hot compression.Also,the particle stimulated nucleation is suggested as the main nucleation mechanism of new recrystallized grains for hot compressed Ca-free alloy On the other hand,the microstructure of the hot compressed Ca-added alloy is greatly affected by the presence of Al4Ca intermetallics.The formation of Al4Ca phase is predicted by JMatPro and revealed by DSC,SEM and TEM studies.Finally,it is found that the presence of Al4Ca precipitates on the grain boundaries of Ca-added alloy prevents the growth of a(Al) by Zener pinning effect and results in the stability of microstructure during homogenization.
基金Project supported by the National High-Tech R&D Program (863) of China (No. 2007AA05Z208)the Scientific Research Foundation for Returned Scholars (No. 50706034), China
文摘The pressure increasing process within a twin screw multiphase pump, under the condition of high gas volume fractions (GVFs), induces large temperature and pressure changes that cause the rotors to deform. Rotor deformations heavily influence the backflow of the multiphase fluid through clearances within the twin screw multiphase pump and these deformations may even lead to pump failures. An accurate temperature and pressure distribution on the screw rotors need be obtained before the deformation analysis can be carried out. By means of small temperature and pressure sensors embedded into the groove at the root of the rotors, the temperatures of 12 points on the rotors and the pressure distributions of a twin screw multiphase pump under high GVFs conditions were recorded. Temperature test results were adopted to perform a heat transfer analysis for determining the temperature distribution on the screw rotors. Then deformation analyses, including thermal deformation, force deformation, and total deformation, were conducted according to the pressure and temperature distributions. Deformation analysis for different materials was also conducted under the same boundary conditions. A material was suggested for the manufacturing of rotors in a twin screw multiphase pump under the condition of high gas volume fractions.
文摘Purpose: The aim of this study was to investigate the incidence of Z-effect after dual lag screw intramedullary nailing systems and risk factors contributing to this effect. We hypothesized that long nails provide more neck strength due to a longer lever than short nails and are therefore less likely to develop a misbalance of a higher head compressive strength than neck compressive strength, Methods: In this retrospective cohort study 103 patients treated operatively with a dual lag screw intramedullary nailing device for (sub)trochanteric hip fracture were included, We analysed patient charts regarding patient and operation characteristics. Furthermore we conducted radiologic mea- surements within the 2-year follow-up period to investigate the quality of fracture fixation, implant failure and predictors for Z-effect. The re-operation risk was investigated with multivariate regression analysis, Results: The incidence of (reversed) Z-effect in this study was 9% (n 80); 6 out of 7 Z-effects occurred in the short nail group, which was not significant. Patients who were treated with a long nail had a significant larger number of complications in comparison with the short nail group (median 2 vs 0,5, p = 0.001). The long nail group received more often erythrocytes blood transfusions (82% vs 31%, p 〈 0.01) and had a longer hospital stay (13 vs 21 days, p 〈 0.05). Migration of lag screws (p 〈0.05) and unstable fracture type (p 〈 0.05), were risk factors for re-operation. The re-operation rate within 2 year after surgery was 21%, of which one fourth was due to a Z-effect. Conclusion: The nail length was not associated with the development of a Z-effect. Migration of lag screws after intramedullary nailing is common and a risk factor for re-operation.
文摘Purpose: Cerclage wire application has emerged as a potential therapeutic adjunct to intramedullary nailing for subtrochanteric fractures. But its popularity is plagued by the concern of possible negative effect on fracture zone biology. This study was intended to analyze the clinico-radiological outcome and complications associated with cerclage wire application. Methods: Retrospective analysis was performed on all the subtrochanteric fractures operated with intramedullary nailing between January 2012 and January 2016. After exclusion, 48 patients were available with an average follow-up of 20.8 months. Long oblique, spiral, spiral wedge or comminuted fracture configurations with butterfly fragments were particularly considered for cerclage wire appli- cation, which was employed by percutaneous cerclage passer in 21 patients. Assessment was done in terms of operation time, blood loss, quality of reduction, neck-shaft angle, follow-up redisplacement, union time, complications, and final functional evaluation by Merle d'Aubigne'-Postel score. Results: Average operation time and blood loss were significantly higher in cerclage group (p 〈 0.05). However, cerclage use substantially improved quality of reduction in terms of maximum cortical displacement (p = 0.003) and fracture angulation (p - 0.045); anatomical reduction was achieved in 95.23% of cases as compared to 74.07% without cerclage. Union time was shorter, although not statis- tically different (p - 0.208), in cerclage group. Four patients in non-cerclage group developed non-union, 2 of them had nail breakage. No infection or any other implant related complications were reported with cerclage use. Conclusion: Minimally-invasive cerclage wire application has proved to be beneficial for anatomical reconstruction in difficult subtrochanteric fractures, whenever applicable, without any harmful effect on fracture biology.
文摘Vesicovaginal fistula (VVF) may be caused by prolonged obstructed labor, gynecologic, urologic, or other pelvic surgery, malignancy, radiation, infection and trauma. Here we report a case of VVF caused by nail penetrating trauma in a young woman with genital bleeding after first intercourse. This is a rare etiology of VVF. We also explain the operative technique used to repair the fistula.
文摘Objective: To treat injury of the lower cervical spine C6 to C7 with cervical lateral mass plates and T1 pedicle screws through posterior approach. Methods: The data of 8 patients with lower cervical spine C6 or C7 injury (6 patients with fracture and dislocation in C6 and C7 and 2 with fracture in C7) were analyzed retrospectively in this study. For the preoperative American Spinal Injury Association (ASIA) classification, Grade C was found in 3 cases and Grade D in 5 cases. Screws were placed on the lateral masses and the first thoracic pedicle with Margerl technique. Lamina or facet bone allografting was used to achieve a long-term stability. Results: All the 8 patients were followed up for 5-37 months (mean: 15 months). No operative death occurred. There were no examples of aggravation of spinal cord injury or vertebral artery injury, cerebrospinal fluid leak, nerve roots injury, screw malposition or back-out, loose of alignment or implant failure. Clinical symptoms and ASIA classification were improved in all the patients. Postoperative MRI scanning confirmed the satisfactory screw placement in all the cases. Conclusions: Lateral mass plates and pedicle screws through posterior approach are safe and beneficial for patients with lower cervical spine C6 or C7 injury.
基金the financial support from the National Key Research and Development Program of China(2016YFA0201001)the National Natural Science Foundation of China(11627801,51102172 and 11772207)+7 种基金Science and Technology Plan of Shenzhen City(JCYJ20160331191436180)the Leading Talents of Guangdong Province Program(2016LJ06C372)the Natural ScienceFoundation for Outstanding Young Researcher in Hebei Province(E2016210093)the Key Program of Educational Commission of Hebei Province of China(ZD2016022)the Youth Top-notch Talents Supporting Plan of Hebei Provincethe Graduate Innovation Foundation of Shijiazhuang Tiedao UniversityHebei Provincial Key Laboratory of Traffic Engineering materialsHebei Key Discipline Construction Project
文摘Ternary Ⅰ–Ⅲ–Ⅵquantum dots(QDs) of chalcopyrite semiconductors exhibit excellent optical properties in solar cells. In this study, ternary chalcopyrite CuGaS2nanocrystals(2–5 nm) were one-pot anchored on TiO2nanoparticles(TiO2@CGS) without any long ligand. The solar cell with TiO2@CuGaS2/N719 has a power conversion efficiency of7.4%, which is 23% higher than that of monosensitized dye solar cell. Anchoring CuGaS2 QDs on semiconductor nanoparticles to form QDs/dye co-sensitized solar cells is a promising and feasible approach to enhance light absorption,charge carrier generation as well as to facilitate electron injection comparing to conventional mono-dye sensitized solar cells.