The effect of the wide and narrow azimuth 3D observation systems on seismic imaging precision is becoming a hot area for studies of high precision 3D seismic acquisition methods in recent years. In this paper we utili...The effect of the wide and narrow azimuth 3D observation systems on seismic imaging precision is becoming a hot area for studies of high precision 3D seismic acquisition methods in recent years. In this paper we utilize 3D physical seismic modeling experiments. A 3D channel sand body physical seismic model is constructed and two acquisition systems are designed with wide azimuth (16 lines) and narrow azimuth (8 lines) to model 3D seismic data acquisition and processing seismic work flows. From analysis of migrated time slice data with high quality and small size, we conclude that when the overlying layers are smooth and lateral velocities have little change, both wide and narrow azimuth observation systems in 3D acquisition can be used for obtaining high precision imaging and equivalent resolution of the channel sand body.展开更多
Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention t...Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.展开更多
Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collect...Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging展开更多
The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focu...The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focus on these discrete sections respectively by a single camera, a group of images would be captured to form governing equations of irradiance. After inversion procedure, the irradiance distribution of different sections could be decoded. In this experimentation two lightbulbs are used to simulate two luminous sections. Reasonable results demonstrate that this technique could be a useful method in irradiance reconstruction after further development.展开更多
Ray casting algorithm can obtain a better quality image in volume rendering, however, it exists some problems, such as powerful computing capacity and slow rendering speed. How to improve the re-sampled speed is a key...Ray casting algorithm can obtain a better quality image in volume rendering, however, it exists some problems, such as powerful computing capacity and slow rendering speed. How to improve the re-sampled speed is a key to speed up the ray casting algorithm. An algorithm is introduced to reduce matrix computation by matrix transformation characteristics of re-sampling points in a two coordinate system. The projection of 3-D datasets on image plane is adopted to reduce the number of rays. Utilizing boundary box technique avoids the sampling in empty voxel. By extending the Bresenham algorithm to three dimensions, each re-sampling point is calculated. Experimental results show that a two to three-fold improvement in rendering speed using the optimized algorithm, and the similar image quality to traditional algorithm can be achieved. The optimized algorithm can produce the required quality images, thus reducing the total operations and speeding up the volume rendering.展开更多
AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging wit...AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging with both oral and intravenous administrations of contrast agents was used to assess gastroscopiclly-confirmed gastric lesions in 46 patients with benign and malignant diseases. Initially, liquid-based ultrasound contrast agent (Xinzhang) was given orally at dose of 500-600 mL for conventional ultrasound examination of the gastric lesions, and then a microbubble-based contrast agent (SonoVue) was injected intravenously at dose of 1.2-2.4 mL in bolus fashion to assess the perfusion pattern of the lesions using contrast imaging modes. The parameters derived from time-intensity curves including the arrival time (AT), time to peak (lq-P), peak intensity (PI) and en- hanced intensity (EI) were measured on the 2D DCUS imaging. 3D DCUS of the lesions was acquired to dem- onstrate the value of this imaging mode. RESULTS: There were 22 cases with benign lesions including chronic gastritis (n= 5), gastric ulcer (n = 9), gastric polyps (n = 3), gastric stromal tumors (n = 5), and 24 cases with malignant lesions including gastric cancer (n = 20), gastric cardia carcinoma (n = 3) and post-operative recurrent gastric cancer (n = 1) in the study, The oral contrast-enhanced ultrasonography (CEUS) imaging of the stomach clearly demonstrated the anatomy of the stomach and morphologic features of gastric lesions, With optimal scanning window and imaging display under oral CEUS, intravenous CEUS clearly showed the perfusion of gastric lesions with various characteristic manifestations. Both 2D and 3D DCUS images clearly demonstrated normal gastric wall as a three-layer structure, from the inside out, hypere- choic mucosa, hypoechoic muscularis and hyperechoic serosa, respectively. There were statistical significant differences of AT (8.68±2.06 vs 10.43 ±2.75, P = 0.017), PI (34.64 ± 6.63 vs 29.58 ± 8.22, P = 0.023) and EI (29.72 ± 6.69 vs 22.66 ± 7.01, P = 0.001) between malignant lesions and normal gastric wall. However, no differences of AT, PI and EI between benign lesions and normal gastric wall tissue were found. 3D DCUS could intuitively display morphological features and vascularities of the lesions with multiplanar and volume views. 3D DCUS imaging provided comprehen- sive information complementary to 2D imaging. The crater or wellhead appearances and feeding vessels as well as distorted nourishing vasculature of gastric carcinoma were better seen with 3D imaging than 2D imaging. CONCLUSION: DCUS imaging can simultaneouslydisplay the anatomic and perfusion features of gastric lesions. 3D DCUS can provide additional information to 2D DCUS for evaluation of gastric lesions.展开更多
Monitoring and delineating the spatial distribution of shale fracturing is fundamentally important to shale gas production. Standard monitoring methods, such as time-lapse seismic, cross-well seismic and micro-seismic...Monitoring and delineating the spatial distribution of shale fracturing is fundamentally important to shale gas production. Standard monitoring methods, such as time-lapse seismic, cross-well seismic and micro-seismic methods, are expensive, time- consuming, and do not show the changes in the formation with time. The resistivities of hydraulic fracturing fluid and reservoir rocks were measured. The results suggest that the injection fluid and consequently the injected reservoir are characterized by very low resistivity and high chargeability. This allows using of the controlled-source electromagnetic method (CSEM) to monitor shale gas hydraulic fracturing. Based on the geoelectrical model which was proposed according to the well-log and seismic data in the test area the change rule of the reacted electrical field was studied to account for the change of shale resistivity, and then the normalized residual resistivity method for time lapse processing was given. The time-domain electromagnetic method (TDEM) was used to continuously monitor the shale gas fracturing at the Fulin shale gas field in southern China. A high-power transmitter and multi-channel transient electromagnetic receiver array were adopted. 9 h time series of Ex component of 224 sites which were laid out on the surface and over three fracturing stages of a horizontal well at 2800 m depth was recorded. After data processing and calculation of the normalized resistivity residuals, the changes in the Ex signal were determined and a dynamic 3D image of the change in resistivity was constructed. This allows modeling the spatial distribution of the fracturing fluid. The model results suggest that TDEM is promising for monitoring hydraulic fracturing of shale.展开更多
Optical coherence tomography(OCT) is a noninvasive,high-resolution,high-potential imaging method that has recently been introduced into medical investigations.A growing number of studies have used this technique in th...Optical coherence tomography(OCT) is a noninvasive,high-resolution,high-potential imaging method that has recently been introduced into medical investigations.A growing number of studies have used this technique in the field of gastroenterology in order to assist classical analyses.Lately,3D-imaging and Doppler capabilities have been developed in different configurations,which make this type of investigation more attractive.This paper reviews the principles and characteristics of OCT and Doppler-OCT in connection with analyses of the detection of normal and pathological structures,and with the possibility to investigate angiogenesis in the gastrointestinal tract.展开更多
Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study...Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study was designed to evaluate the diagnostic value of 3D spiral CT imaging of cholangiopancreatic ducts on obstructive jaundice. Methods: Thirty patients with obstructive jaundice had received B-mode ultrasonography, CT, percutaneous transhepatic cholangiography (PTC) or endoscopic retrograde cholangiopancreatography (ERCP), and 3D spiral CT imaging of cholangiopancreatic ducts preoperatively. Then the diagnose accordance rate of these examinational methods were compared after operations. Results: The diagnose accordance rate of 3D spiral CT imaging of cholangiopancreatic ducts was higher than those of B-mode ultrasonography, CT, or single PTC or ERCP, which showed clear images of bile duct tree and pathological changes. As to malignant obstructive jaundice, this examinational technique could clearly display the adjacent relationship between tumor and liver tissue, biliary ducts, blood vessels, and intrahepatic metastases. Conclusion: 3D spiral CT imaging of cholangiopancreatic ducts has significant value for obstructive diseases of biliary ducts, which provides effective evidence for the feasibility of tumor-resection and surgical options.展开更多
Induced polarization (IP) 3D tomography with the similar central gradient array combines IP sounding and IP profiling to retrieve 3D resistivity and polarization data rapidly. The method is characterized by high spa...Induced polarization (IP) 3D tomography with the similar central gradient array combines IP sounding and IP profiling to retrieve 3D resistivity and polarization data rapidly. The method is characterized by high spatial resolution and large probing depth. We discuss data acquisition and 3D IP imaging procedures using the central gradient array with variable electrode distances. A 3D geoelectric model was constructed and then numerically modeled. The data modeling results suggest that this method can capture the features of real geoelectric models. The method was applied to a polymetallic mine in Gansu Province. The results suggest that IP 3D tomography captures the distribution of resistivity and polarization of subsurface media, delineating the extension of abrupt interfaces, and identifies mineralization.展开更多
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes...This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics.展开更多
Thermal shocking effect occurs when the coalbed methane(CBM)reservoirs meet liquid nitrogen(LN2)of extremely low temperature.In this study,3D via X-ray microcomputer tomography(μCT)and scanning electron microscope(SE...Thermal shocking effect occurs when the coalbed methane(CBM)reservoirs meet liquid nitrogen(LN2)of extremely low temperature.In this study,3D via X-ray microcomputer tomography(μCT)and scanning electron microscope(SEM)are employed to visualize and quantify morphological evolution characteristics of fractures in coal after LN2 thermal shocking treatments.LN2 thermal shocking leads to a denser fracture network than its original state with coal porosity growth rate increasing up to 183.3%.The surface porosity of theμCT scanned layers inside the coal specimen is influenced by LN2 thermal shocking which rises from 18.76%to 215.11%,illustrating the deformation heterogeneity of coal after LN2 thermal shocking.The cracking effect of LN2 thermal shocking on the surface of low porosity is generally more effective than that of high surface porosity,indicating the applicability of LN2 thermal shocking on low-permeability CBM reservoir stimulation.The characteristics of SEM scanned coal matrix in the coal powder and the coal block after the LN2 thermal shocking presented a large amount of deep and shallow progressive scratch layers,fracture variation diversity(i.e.extension,propagation,connectivity,irregularity)on the surface of the coal block and these were the main reasons leading to the decrease of the uniaxial compressive strength of the coal specimen.展开更多
In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interac...In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interaction region of the lens system from the high DC voltages applied to all other plates than the repeller and extractor plates.The Simion simulation shows that both velocity-mapping and time focusing can be achieved simultaneously when appropriate voltages are applied to each of the plates.This makes the ion lens system be able to focus large ionic volumes in all three dimensions,which is an essential requirement for crossed ion-molecule scattering studies.A three-dimensional ion velocity measurement system with multi-hit and potential multi-mass capability is built,which consists of a microchannel plate(MCP),a P47 phosphor screen,a CMOS camera,a fast photomultiplier tube(PMT),and a high-speed digitizer.The two velocity components perpendicular to the flight axis are measured by the CMOS camera,and the time-of-flight,from which the velocity component along the flight axis can be deduced,is measured by the PMT.A Labview program is written to combine the two measurements for building the full three-dimensional ion velocity in real time on a frame-by-frame basis.The multi-hit capability comes from the fact that multiple ions from the camera and PMT in the same frame can be correlated with each other based on their various intensities.We demonstrate this by using the photodissociation of CH31 at 304 nm.展开更多
Based on the recording data from the analogue and broadband digital seismic stations in and around Qinghai-Xizang (Tibet) Plateau, the three dimensional (3-D) seismic velocity structures in Qinghai-Xizang Plateau were...Based on the recording data from the analogue and broadband digital seismic stations in and around Qinghai-Xizang (Tibet) Plateau, the three dimensional (3-D) seismic velocity structures in Qinghai-Xizang Plateau were obtained by using the regional body wave tomography and surface wave tomography. The results from these two tomography methods have similar characteristics for P- and S-wave velocity structures in crust and upper mantle. They show that there are remarkable low velocity zones in the upper crust of Lhasa block in the southern Qinghai-Xizang Plateau and the lower crust and upper mantle of Qiangtang block in the northern Qinghai-Xizang Plateau. These phenomena may be related to the different steps of collision process in southern and northern Qinghai-Xizang Plateau.展开更多
In this article the problem of three-dimensional (3-D) reconstruction of scenes from terrestrial laser rangefinder data is processed, we present the simulations results of radiometric range function of the laser ran...In this article the problem of three-dimensional (3-D) reconstruction of scenes from terrestrial laser rangefinder data is processed, we present the simulations results of radiometric range function of the laser range finder imaging system for better optimization of maximum range detection with a given SNR (Signal-to-noise ratio). The study proposes a new reformulation of the radiometric Gaussian beam range equation on the basis of the photodetector active area. The adjustment of the optical and geometrical characteristics of the laser range finder so defined can be used to minimize the signal span to avoid the saturation of the detector cell and improve the ranging measurements (accuracy and range) for a 3D imaging application.展开更多
Imaging is now a well established component of radiation therapy with all major imaging modalities represented and numerous examples in which these modalities have been used in treatment planning to allow increased ac...Imaging is now a well established component of radiation therapy with all major imaging modalities represented and numerous examples in which these modalities have been used in treatment planning to allow increased accuracy and precision in the delivery of dose.While these developments are well established since a fairly long time for external beam radiotherapy,they are yet to be firmly established in many brachytherapy units all over the world particularly in the developing countries.We will review the basic principles of image-based brachytherapy and explore the potential clinical opportunities behind this innovative technique.展开更多
This study presents a reliable method for the semi-automatic generation of an FE model, which determines both geometrical data and bone properties from patient CT scans.3D FE analysis is one of the best approaches to ...This study presents a reliable method for the semi-automatic generation of an FE model, which determines both geometrical data and bone properties from patient CT scans.3D FE analysis is one of the best approaches to predict the stress and strain distribution in complex bone structures, but its accuracy strongly depends on the precision of input information. In geometric reconstruction, various methods of image processing, geometric modeling and finite element analysis are combined and extended. Emphasis is given to the assignment of the material properties based on the density values computed from CT data. Through this technique, the model with high geometric and material similarities were generated in an easy way. Consequently, the patient-specific FE model from mandible CT data is realized also.展开更多
In this paper,using natural earthquake P-wave arrival time data recorded by the seismic network in the surrounding area of Madoi,the three-dimensional fine P-wave crustal velocity structure at depths above 60 km in th...In this paper,using natural earthquake P-wave arrival time data recorded by the seismic network in the surrounding area of Madoi,the three-dimensional fine P-wave crustal velocity structure at depths above 60 km in the epicenter of the Madoi Ms7.4 earthquake was inverted using the double-difference seismic tomography method.On the basis of the relocation of the source of the aftershock sequence,we summarized the strip-shaped distribution characteristics along the strike of the Jiangcuo fault,revealing the significant heterogeneity of the crustal velocity structure in the source area.Research has found that most of the Madoi Ms7.4 aftershocks were located in the weak area of the high-speed anomaly in the upper crust.The focal depth changed with the velocity structure,showing obvious fluctuation and segmentation characteristics.There was a good correspondence between the spatial distribution and the velocity structure.The high-velocity bodies of the upper crust in the hypocenter area provided a medium environment for earthquake rupture,the low-velocity bodies of the middle crust formed the deep material,and the migration channel and the undulating shape of the high-speed body in the lower crust corroborated the strong pushing action in the region.The results confirmed that under the continuous promotion of tectonic stress in the Madoi area,the high-speed body of the Jiangcuo fault blocked the migration of weak materials in the middle crust.When the stress accumulation exceeded the limit,the Madoi Ms7.4 earthquake occurred.Meanwhile,the nonuniform velocity structure near the fault plane determined the location of the main shock and the spatiotemporal distribution of the aftershock sequence.展开更多
基金supported by the National Basic Research Program (the 973 Program, No. 2007CB209601).
文摘The effect of the wide and narrow azimuth 3D observation systems on seismic imaging precision is becoming a hot area for studies of high precision 3D seismic acquisition methods in recent years. In this paper we utilize 3D physical seismic modeling experiments. A 3D channel sand body physical seismic model is constructed and two acquisition systems are designed with wide azimuth (16 lines) and narrow azimuth (8 lines) to model 3D seismic data acquisition and processing seismic work flows. From analysis of migrated time slice data with high quality and small size, we conclude that when the overlying layers are smooth and lateral velocities have little change, both wide and narrow azimuth observation systems in 3D acquisition can be used for obtaining high precision imaging and equivalent resolution of the channel sand body.
文摘Objective: To evaluate three-dimensional bronchial artery imaging charactersin central lung cancer and applied values with multi-slice spiral CT (MSCT) to provide theoreticalevidence on blood supply and intervention therapy. Methods: Eighteen patients with central lungcancer underwent MSCT with real time helical thin-slice CT scanning. Three-dimensional bronchialartery reconstruction was done at the console work-station. The space anatomical characters ofbronchial artery were observed through different rotations. Results: For 6 cases, thethree-dimensional images of bronchial artery (33.33%) could exactly show the origins, the routes(lung inner segment and mediatism segment) and the diameters of bronchial arteries. Vision rate ofbronchial arteries was the highest in pulmonary artery stricture and truncation groups, and thevessels' diameter became larger apparently. These characters demonstrated blood supply of this kindof central lung cancer come from bronchial artery. Volume rendering images were the best ones amongthree-dimensional images. Conclusion: Three-dimensional imaging with MSCT in bronchial artery canreveal the anatomical characters of bronchial artery and provide theoretical evidence on bloodsupply and intervention therapy of central lung cancer.
文摘Objective: To study the clinical significance of multi-slice spiral CT 3-dimensional (3D) portography in portal vein tumor thrombosis of hepatocellular cacinoma.Methods: 57 cases undergoing 3D portography were collected, of which 6 cases were normal, 5 cases were subjected to cirrhosis and hypertension of portal vein, 42 cases had portal tumor thrombus of hepatic cancer, and the remaining 4 cases showed lymph node enlargment in hilar of liver. All data of the patients came from conventional multi-slice spiral CT double phase of liver. Contrast media was 1.5–2 ml/kg with the injection rate being 2.5–3 ml/s. Axis and 3D portography was analyzed and compared in 42 cases of portal tumor thrombus of hepatic cancer.Results: According to portal tumor thrombus position, 42 cases were fallen into three categories: left (13 cases), right (20 cases), main (9 cases) of potal vein. There was no difference between axis and 3D portography in displaying portal tumor thrombus of hepatic cancer (P>0.05), but 3D portography showing collateral branches was better than axis portography after main portal vein thrombus.Conclusion: Multi-slice spiral CT 3D portography can display the position and types of portal tumor thrombus of hepatic cancer. 3D combined with axis portography can better evaluate the portal tumor thrombus of hepatic cancer and guide to select the therapies. Key words portal vein - tumor thrombus - multi-slice CT - 3 dimension imaging
文摘The focusing tomography is presented to reconstruct 3 dimensional irradiance distribution. A 3 dimensional luminous body could be considered as the combination of many 2 dimensional parallel luminous sections. Focus on these discrete sections respectively by a single camera, a group of images would be captured to form governing equations of irradiance. After inversion procedure, the irradiance distribution of different sections could be decoded. In this experimentation two lightbulbs are used to simulate two luminous sections. Reasonable results demonstrate that this technique could be a useful method in irradiance reconstruction after further development.
文摘Ray casting algorithm can obtain a better quality image in volume rendering, however, it exists some problems, such as powerful computing capacity and slow rendering speed. How to improve the re-sampled speed is a key to speed up the ray casting algorithm. An algorithm is introduced to reduce matrix computation by matrix transformation characteristics of re-sampling points in a two coordinate system. The projection of 3-D datasets on image plane is adopted to reduce the number of rays. Utilizing boundary box technique avoids the sampling in empty voxel. By extending the Bresenham algorithm to three dimensions, each re-sampling point is calculated. Experimental results show that a two to three-fold improvement in rendering speed using the optimized algorithm, and the similar image quality to traditional algorithm can be achieved. The optimized algorithm can produce the required quality images, thus reducing the total operations and speeding up the volume rendering.
基金Supported by A key medical project in Nanjing Military District of the Chinese People’s Liberation Army,No. 09Z039
文摘AIM: To investigate the value of two-dimensional (2D) and three-dimensional (3D) double contrast-enhanced ultrasonography (DCUS) imaging for evaluation of gas- tric lesions. METHODS: 2D and 3D DCUS imaging with both oral and intravenous administrations of contrast agents was used to assess gastroscopiclly-confirmed gastric lesions in 46 patients with benign and malignant diseases. Initially, liquid-based ultrasound contrast agent (Xinzhang) was given orally at dose of 500-600 mL for conventional ultrasound examination of the gastric lesions, and then a microbubble-based contrast agent (SonoVue) was injected intravenously at dose of 1.2-2.4 mL in bolus fashion to assess the perfusion pattern of the lesions using contrast imaging modes. The parameters derived from time-intensity curves including the arrival time (AT), time to peak (lq-P), peak intensity (PI) and en- hanced intensity (EI) were measured on the 2D DCUS imaging. 3D DCUS of the lesions was acquired to dem- onstrate the value of this imaging mode. RESULTS: There were 22 cases with benign lesions including chronic gastritis (n= 5), gastric ulcer (n = 9), gastric polyps (n = 3), gastric stromal tumors (n = 5), and 24 cases with malignant lesions including gastric cancer (n = 20), gastric cardia carcinoma (n = 3) and post-operative recurrent gastric cancer (n = 1) in the study, The oral contrast-enhanced ultrasonography (CEUS) imaging of the stomach clearly demonstrated the anatomy of the stomach and morphologic features of gastric lesions, With optimal scanning window and imaging display under oral CEUS, intravenous CEUS clearly showed the perfusion of gastric lesions with various characteristic manifestations. Both 2D and 3D DCUS images clearly demonstrated normal gastric wall as a three-layer structure, from the inside out, hypere- choic mucosa, hypoechoic muscularis and hyperechoic serosa, respectively. There were statistical significant differences of AT (8.68±2.06 vs 10.43 ±2.75, P = 0.017), PI (34.64 ± 6.63 vs 29.58 ± 8.22, P = 0.023) and EI (29.72 ± 6.69 vs 22.66 ± 7.01, P = 0.001) between malignant lesions and normal gastric wall. However, no differences of AT, PI and EI between benign lesions and normal gastric wall tissue were found. 3D DCUS could intuitively display morphological features and vascularities of the lesions with multiplanar and volume views. 3D DCUS imaging provided comprehen- sive information complementary to 2D imaging. The crater or wellhead appearances and feeding vessels as well as distorted nourishing vasculature of gastric carcinoma were better seen with 3D imaging than 2D imaging. CONCLUSION: DCUS imaging can simultaneouslydisplay the anatomic and perfusion features of gastric lesions. 3D DCUS can provide additional information to 2D DCUS for evaluation of gastric lesions.
基金supported by NSFC(Grant No.U1562109 and 41774082)the National Major Research Plan(Grant No.2016YFC0601100and 2016ZX05004)the Project of Scientific Research and Technological Development,CNPC(Grant No.2017D-5006-16)
文摘Monitoring and delineating the spatial distribution of shale fracturing is fundamentally important to shale gas production. Standard monitoring methods, such as time-lapse seismic, cross-well seismic and micro-seismic methods, are expensive, time- consuming, and do not show the changes in the formation with time. The resistivities of hydraulic fracturing fluid and reservoir rocks were measured. The results suggest that the injection fluid and consequently the injected reservoir are characterized by very low resistivity and high chargeability. This allows using of the controlled-source electromagnetic method (CSEM) to monitor shale gas hydraulic fracturing. Based on the geoelectrical model which was proposed according to the well-log and seismic data in the test area the change rule of the reacted electrical field was studied to account for the change of shale resistivity, and then the normalized residual resistivity method for time lapse processing was given. The time-domain electromagnetic method (TDEM) was used to continuously monitor the shale gas fracturing at the Fulin shale gas field in southern China. A high-power transmitter and multi-channel transient electromagnetic receiver array were adopted. 9 h time series of Ex component of 224 sites which were laid out on the surface and over three fracturing stages of a horizontal well at 2800 m depth was recorded. After data processing and calculation of the normalized resistivity residuals, the changes in the Ex signal were determined and a dynamic 3D image of the change in resistivity was constructed. This allows modeling the spatial distribution of the fracturing fluid. The model results suggest that TDEM is promising for monitoring hydraulic fracturing of shale.
基金Supported by Project number 99CP/I//2007 ANCSProject number 12-106/2008 CNMP,Romania
文摘Optical coherence tomography(OCT) is a noninvasive,high-resolution,high-potential imaging method that has recently been introduced into medical investigations.A growing number of studies have used this technique in the field of gastroenterology in order to assist classical analyses.Lately,3D-imaging and Doppler capabilities have been developed in different configurations,which make this type of investigation more attractive.This paper reviews the principles and characteristics of OCT and Doppler-OCT in connection with analyses of the detection of normal and pathological structures,and with the possibility to investigate angiogenesis in the gastrointestinal tract.
基金Supported by a grant of Jiangxi Province Scientific Technologic Foundation (No. E990611)
文摘Objective: Computerized tomography (CT) plays an important role in the diagnosis of diseases of biliary tract. Recently, three dimensions (3D) spiral CT imaging has been used in surgical diseases gradually. This study was designed to evaluate the diagnostic value of 3D spiral CT imaging of cholangiopancreatic ducts on obstructive jaundice. Methods: Thirty patients with obstructive jaundice had received B-mode ultrasonography, CT, percutaneous transhepatic cholangiography (PTC) or endoscopic retrograde cholangiopancreatography (ERCP), and 3D spiral CT imaging of cholangiopancreatic ducts preoperatively. Then the diagnose accordance rate of these examinational methods were compared after operations. Results: The diagnose accordance rate of 3D spiral CT imaging of cholangiopancreatic ducts was higher than those of B-mode ultrasonography, CT, or single PTC or ERCP, which showed clear images of bile duct tree and pathological changes. As to malignant obstructive jaundice, this examinational technique could clearly display the adjacent relationship between tumor and liver tissue, biliary ducts, blood vessels, and intrahepatic metastases. Conclusion: 3D spiral CT imaging of cholangiopancreatic ducts has significant value for obstructive diseases of biliary ducts, which provides effective evidence for the feasibility of tumor-resection and surgical options.
基金funded jointly by the National High Technology Research and Development Program(863 Program:No.2014AA06A610)special funds for basic scientific research business expenses of the Chinese Academy of Geological Sciences(No.YYWF201632)the National Major Scientific Instruments and Equipment Development Projects(No.2011YQ050060)
文摘Induced polarization (IP) 3D tomography with the similar central gradient array combines IP sounding and IP profiling to retrieve 3D resistivity and polarization data rapidly. The method is characterized by high spatial resolution and large probing depth. We discuss data acquisition and 3D IP imaging procedures using the central gradient array with variable electrode distances. A 3D geoelectric model was constructed and then numerically modeled. The data modeling results suggest that this method can capture the features of real geoelectric models. The method was applied to a polymetallic mine in Gansu Province. The results suggest that IP 3D tomography captures the distribution of resistivity and polarization of subsurface media, delineating the extension of abrupt interfaces, and identifies mineralization.
基金National Natural Science Foundation of China (50275139) Natural Science Foundation of Zhejiang (01388-G)
文摘This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics.
基金Project(2017XKQY012)supported by the Fundamental Research Funds for the Central Universities,China。
文摘Thermal shocking effect occurs when the coalbed methane(CBM)reservoirs meet liquid nitrogen(LN2)of extremely low temperature.In this study,3D via X-ray microcomputer tomography(μCT)and scanning electron microscope(SEM)are employed to visualize and quantify morphological evolution characteristics of fractures in coal after LN2 thermal shocking treatments.LN2 thermal shocking leads to a denser fracture network than its original state with coal porosity growth rate increasing up to 183.3%.The surface porosity of theμCT scanned layers inside the coal specimen is influenced by LN2 thermal shocking which rises from 18.76%to 215.11%,illustrating the deformation heterogeneity of coal after LN2 thermal shocking.The cracking effect of LN2 thermal shocking on the surface of low porosity is generally more effective than that of high surface porosity,indicating the applicability of LN2 thermal shocking on low-permeability CBM reservoir stimulation.The characteristics of SEM scanned coal matrix in the coal powder and the coal block after the LN2 thermal shocking presented a large amount of deep and shallow progressive scratch layers,fracture variation diversity(i.e.extension,propagation,connectivity,irregularity)on the surface of the coal block and these were the main reasons leading to the decrease of the uniaxial compressive strength of the coal specimen.
基金This work is supported by the Program for Young Outstanding Scientists of Institute of Chemistry,Chinese Academy of Science,and Beijing National Laboratory for Molecular SciencesHong Gao and Li-chang Guan are also supported by the K.C.Wong Education Foundation.
文摘In this study,we report the design and simulation of an electrostatic ion lens system consisting of 22 round metal plates.The opening of the extractor plate is covered withmetal mesh,which is for shielding the interaction region of the lens system from the high DC voltages applied to all other plates than the repeller and extractor plates.The Simion simulation shows that both velocity-mapping and time focusing can be achieved simultaneously when appropriate voltages are applied to each of the plates.This makes the ion lens system be able to focus large ionic volumes in all three dimensions,which is an essential requirement for crossed ion-molecule scattering studies.A three-dimensional ion velocity measurement system with multi-hit and potential multi-mass capability is built,which consists of a microchannel plate(MCP),a P47 phosphor screen,a CMOS camera,a fast photomultiplier tube(PMT),and a high-speed digitizer.The two velocity components perpendicular to the flight axis are measured by the CMOS camera,and the time-of-flight,from which the velocity component along the flight axis can be deduced,is measured by the PMT.A Labview program is written to combine the two measurements for building the full three-dimensional ion velocity in real time on a frame-by-frame basis.The multi-hit capability comes from the fact that multiple ions from the camera and PMT in the same frame can be correlated with each other based on their various intensities.We demonstrate this by using the photodissociation of CH31 at 304 nm.
文摘Based on the recording data from the analogue and broadband digital seismic stations in and around Qinghai-Xizang (Tibet) Plateau, the three dimensional (3-D) seismic velocity structures in Qinghai-Xizang Plateau were obtained by using the regional body wave tomography and surface wave tomography. The results from these two tomography methods have similar characteristics for P- and S-wave velocity structures in crust and upper mantle. They show that there are remarkable low velocity zones in the upper crust of Lhasa block in the southern Qinghai-Xizang Plateau and the lower crust and upper mantle of Qiangtang block in the northern Qinghai-Xizang Plateau. These phenomena may be related to the different steps of collision process in southern and northern Qinghai-Xizang Plateau.
文摘In this article the problem of three-dimensional (3-D) reconstruction of scenes from terrestrial laser rangefinder data is processed, we present the simulations results of radiometric range function of the laser range finder imaging system for better optimization of maximum range detection with a given SNR (Signal-to-noise ratio). The study proposes a new reformulation of the radiometric Gaussian beam range equation on the basis of the photodetector active area. The adjustment of the optical and geometrical characteristics of the laser range finder so defined can be used to minimize the signal span to avoid the saturation of the detector cell and improve the ranging measurements (accuracy and range) for a 3D imaging application.
文摘Imaging is now a well established component of radiation therapy with all major imaging modalities represented and numerous examples in which these modalities have been used in treatment planning to allow increased accuracy and precision in the delivery of dose.While these developments are well established since a fairly long time for external beam radiotherapy,they are yet to be firmly established in many brachytherapy units all over the world particularly in the developing countries.We will review the basic principles of image-based brachytherapy and explore the potential clinical opportunities behind this innovative technique.
文摘This study presents a reliable method for the semi-automatic generation of an FE model, which determines both geometrical data and bone properties from patient CT scans.3D FE analysis is one of the best approaches to predict the stress and strain distribution in complex bone structures, but its accuracy strongly depends on the precision of input information. In geometric reconstruction, various methods of image processing, geometric modeling and finite element analysis are combined and extended. Emphasis is given to the assignment of the material properties based on the density values computed from CT data. Through this technique, the model with high geometric and material similarities were generated in an easy way. Consequently, the patient-specific FE model from mandible CT data is realized also.
基金support:Seismic Regime Tracking Project of CEA (2023010123)Combination Project with Monitoring,Prediction and Scientific Research of Earthquake Technology,CEA (3JH-202302019).
文摘In this paper,using natural earthquake P-wave arrival time data recorded by the seismic network in the surrounding area of Madoi,the three-dimensional fine P-wave crustal velocity structure at depths above 60 km in the epicenter of the Madoi Ms7.4 earthquake was inverted using the double-difference seismic tomography method.On the basis of the relocation of the source of the aftershock sequence,we summarized the strip-shaped distribution characteristics along the strike of the Jiangcuo fault,revealing the significant heterogeneity of the crustal velocity structure in the source area.Research has found that most of the Madoi Ms7.4 aftershocks were located in the weak area of the high-speed anomaly in the upper crust.The focal depth changed with the velocity structure,showing obvious fluctuation and segmentation characteristics.There was a good correspondence between the spatial distribution and the velocity structure.The high-velocity bodies of the upper crust in the hypocenter area provided a medium environment for earthquake rupture,the low-velocity bodies of the middle crust formed the deep material,and the migration channel and the undulating shape of the high-speed body in the lower crust corroborated the strong pushing action in the region.The results confirmed that under the continuous promotion of tectonic stress in the Madoi area,the high-speed body of the Jiangcuo fault blocked the migration of weak materials in the middle crust.When the stress accumulation exceeded the limit,the Madoi Ms7.4 earthquake occurred.Meanwhile,the nonuniform velocity structure near the fault plane determined the location of the main shock and the spatiotemporal distribution of the aftershock sequence.