期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
两种湿化液对人工气道患者气道湿化的疗效比较 被引量:7
1
作者 董恩霞 李文慧 董补怀 《陕西医学杂志》 CAS 北大核心 2008年第4期472-473,共2页
目的:探讨两种湿化液对人工气道患者气道湿化的效果。方法:选取60例建立人工气道患者随机分为A、B两组,B组(对照组)采用0.9%氯化钠+庆大霉素+糜蛋白酶液湿化,A组(实验组)采用0.9%氯化钠+5%碳酸氢钠+沐舒坦液湿化,观察痰液粘度、气道粘... 目的:探讨两种湿化液对人工气道患者气道湿化的效果。方法:选取60例建立人工气道患者随机分为A、B两组,B组(对照组)采用0.9%氯化钠+庆大霉素+糜蛋白酶液湿化,A组(实验组)采用0.9%氯化钠+5%碳酸氢钠+沐舒坦液湿化,观察痰液粘度、气道粘膜出血、刺激性咳嗽、肺部感染及脉搏氧饱和度情况。结果:A组患者痰液粘度明显低于B组,气道粘膜出血、刺激性咳嗽、肺部感染发生率也明显低,且脉搏氧饱和度明显高。结论:人工气道患者采用0.9%氯化钠+5%碳酸氢钠+沐舒坦液湿化明显优于0.9%氯化钠+庆大霉素+糜蛋白酶液湿化。 展开更多
关键词 气管切开术 气管造口术 @呼吸道湿 @湿化液
下载PDF
Improvement of conventional liquid desiccant dehumidification technology
2
作者 王俐 连之伟 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期212-216,共5页
A new system of liquid desiccant dehumidification,called ultrasound atomization dehumidification system,is proposed.In this system,a packed bed is replaced by ultrasound atomization technology,so high resistance and l... A new system of liquid desiccant dehumidification,called ultrasound atomization dehumidification system,is proposed.In this system,a packed bed is replaced by ultrasound atomization technology,so high resistance and liquid desiccant consumption caused by the packed bed are avoided.A mathematical model is established to predict the efficiency and the liquid consumption of the dehumidification process under ideal conditions.Through comparing the simulation results with the experimental data of a conventional packed-bed dehumidifier,it is found that the liquid desiccant consumption of the conventional packed-bed dehumidifier is much greater than that under ideal conditions.In the proposed system,the dehumidification process occurs on the surfaces of the micron liquid desiccant droplets produced with the irradiation of ultrasound,so there is a greater contact area created with the same quantity of the liquid desiccant;moreover,the power consumption is lower because there are no nozzles and no solution pump.It can be seen that this new system is closer to ideal conditions when compared with the conventional liquid desiccant dehumidification system. 展开更多
关键词 packed bed liquid desiccant dehumidification atomization dehumidification ULTRASOUND SIMULATION
下载PDF
Comparison of deep desulfurization methods in alumina production process 被引量:5
3
作者 刘战伟 李旺兴 +2 位作者 马文会 尹中林 武国宝 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第10期3745-3750,共6页
Several methods of deep desulfurization in alumina production process were studied, and the costs of these methods were compared. It is found that most of the S2- in sodium aluminate solution can be removed by adding ... Several methods of deep desulfurization in alumina production process were studied, and the costs of these methods were compared. It is found that most of the S2- in sodium aluminate solution can be removed by adding sodium nitrate or hydrogen peroxide in digestion process, and in this way the effect of S2- on alumina product quality is eliminated. However, the removal efficiency of 2?32OS in sodium aluminate solution is very low by this method. Both S2- and 2?32OS in sodium aluminate solution can be removed completely by wet oxidation method in digestion process. The cost of desulfurization by wet oxidation is lower than by adding sodium nitrate or hydrogen peroxide. The results of this research reveal that wet oxidation is an economical and feasible method for the removal of sulfur in alumina production process to improve alumina quality, and provide valuable guidelines for alumina production by high-sulfur bauxite. 展开更多
关键词 high-sulfur bauxite alumina production DESULFURIZATION wet oxidation
下载PDF
Thermodynamic equilibrium of bismuth hydrometallurgyin chloride and nitrate solutions 被引量:2
4
作者 王云燕 彭文杰 柴立元 《Journal of Central South University of Technology》 2004年第4期410-413,共4页
Simultaneous equilibrium was applied to the thermodynamic analysis and calculation of Bi(Ⅲ)-X(Cl-, NO-3)-H2O systems, based on which the diagrams of the logarithm of equilibrium concentration of Bi(Ⅲ) of serie... Simultaneous equilibrium was applied to the thermodynamic analysis and calculation of Bi(Ⅲ)-X(Cl-, NO-3)-H2O systems, based on which the diagrams of the logarithm of equilibrium concentration of Bi(Ⅲ) of series precipitation vs pH value of these two systems at 25 ℃ were obtained, and the pH ranges of the stable zones of various precipitations were analyzed and determined. In Bi(Ⅲ)-Cl--H2O system, the variations of c0(Bi3+) and (c0(Cl-)) have little effect on the equilibria of Bi(OH)3-solution and BiOOH-solution, but has great influence on the (equilibrium) of BiOCl-solution. However, in Bi(Ⅲ)-NO-3-H2O system, the variations of c0(Bi3+) and c0(NO-3) have little effect on equilibria of Bi(OH)3-solution, BiOOH-solution and Bi2O3-solution. When pH value is high, Bi2O3 is the thermodynamic stable phase, its stable zone is the widest, almost including the stable zones of BiOCl or (BiONO3,) (Bi(OH)3) and BiOOH. Bi(OH)3 cannot be obtained from Bi(Ⅲ)-Cl--H2O system, even strong alkaline media. Bi2O3 can be obtained from the solution directly, and highly pure BiOCl or BiONO3 can also be obtained through strictly controlling pH value. 展开更多
关键词 Bi(Ⅲ)-X(Cl^- NO^-_3)-H_2O system thermodynamic equilibrium Bi_2O_3 BiOCl BiONO_3
下载PDF
Demulsification of Emulsion Liquid Membrane by Wetting Coalescence Materials 被引量:1
5
作者 孙德智 段晓东 +1 位作者 姜兆华 周定 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1999年第1期38-46,共9页
Demulsification of emulsified water-in-oil droplets was worked out with the employment of wetting coalescence materials. Demulsification is carried out in conventional stirred-column and packed-column. Among the four ... Demulsification of emulsified water-in-oil droplets was worked out with the employment of wetting coalescence materials. Demulsification is carried out in conventional stirred-column and packed-column. Among the four kinds of natural fibers and two kinds of inorganic materials tested, natural fiber A, originated from wood shavings was found to give the best performance of demulsification. The demulsification efficiency can exceed 96.5% when demulsification conditions are optimized. The packed-column showed much better performance both in terms of demulsification efficiency and repeated use of the recovered oil phase for extracting cadmium in simulated wastewater. Operating variables governing the demulsification efficiency were investigated. 展开更多
关键词 DEMULSIFICATION EMULSION wet coalescence cadmium extraction
下载PDF
Influence of Electrolyte on ESR of Medium Voltage Wet Tantalum Capacitors 被引量:3
6
作者 刘仲娥 宋金荣 +2 位作者 陈晓静 李忆莲 桂娟 《Transactions of Tianjin University》 EI CAS 2004年第3期163-166,共4页
In this paper, the influence of working electrolyte on high-frequency electrical performance of wet tantalum capacitors is studied. Emphasis is especially put on the study of the contribution of depolariser in reducin... In this paper, the influence of working electrolyte on high-frequency electrical performance of wet tantalum capacitors is studied. Emphasis is especially put on the study of the contribution of depolariser in reducing Equivalent Series Resistance(ESR). According to the theory of depolarization in electrochemistry and the theory of cathode capacitance of electrolytic capacitor, different kinds of depolarisers are added separately into the foregone electrolyte. Then capacitors are assembled with tantalum cores dipped with the compounded electrolytes. The best depolariser and its concentration in the whole electrolyte could be selected according to the test results of the capacitance and ESR of the capacitors. The results of our experiment show that depolariser Fe 2(SO 4) 3 used in working electrolyte of 100 V/100 μF wet tantalum capacitors can help to obtain lower ESR and higher capacitance at frequency from 0.1 kHz to 100 kHz. 展开更多
关键词 depolariser electrical double layer electrical performance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部