期刊文献+
共找到129篇文章
< 1 2 7 >
每页显示 20 50 100
Simulation of Diode-Pumped Q-Switched Nd:YAG Laser Generating Eye-Safe Signal in IOPO Environment
1
作者 Mian M. Ashraf Muhammad Siddique 《Optics and Photonics Journal》 2012年第3期167-172,共6页
Numerical simulation of diode-pumped Q-switched Nd:YAG laser leading to the generation of eye-safe signal in singly resonant Intracavity Optical Parametric Oscillator (IOPO) is presented. Starting from rate equations,... Numerical simulation of diode-pumped Q-switched Nd:YAG laser leading to the generation of eye-safe signal in singly resonant Intracavity Optical Parametric Oscillator (IOPO) is presented. Starting from rate equations, the time dependent laser equations have been solved numerically, whereas the space-dependent OPO equations analytically. Our results show that 1.4 J diode laser (810 nm) pulse with 200 msec width, delivers 30 mJ Nd:YAG laser (1064 nm) pulse with 5 n-second width. This Nd:YAG laser further generates 9 mJ eye safe signal (1570 nm) pulse with 2.5 n-second width. 展开更多
关键词 SIMULATION Diode laser Q-SWITCHED Nd:YAG laser eye-safe laser SIGNAL Idler IOPO Rate Equations Out-Put Power KTP Non-Linear Crystal Pump Beam WAIST
下载PDF
Femtosecond laser fabrication of 3D templates for mass production of artificial compound eyes 被引量:3
2
作者 Guang-Xin Jin Xin-Yu Hu +3 位作者 Zhuo-Chen Ma Chun-He Li Yong-Lai Zhang Hong-Bo Sun 《Nanotechnology and Precision Engineering》 EI CAS CSCD 2019年第3期110-117,共8页
Compound eyes are unique optical imaging systems that consist of numerous separate light-sensitive units(ommatidia).Attempts have been made to produce artificial compound eyes via advanced 3 D nanotechnologies.Among t... Compound eyes are unique optical imaging systems that consist of numerous separate light-sensitive units(ommatidia).Attempts have been made to produce artificial compound eyes via advanced 3 D nanotechnologies.Among them,femtosecond laser direct writing(FsLDW)technology has emerged as an effective strategy due to its distinct advantages in 3 D designable and high precision fabrication capability.However,the point-by-point scanning process results in a very low fabrication efficiency,limiting the practical applications of the FsLDW technology.To solve this problem,we propose a high-efficiency method for the mass production of 3 D artificial compound eyes using a photopolymer template fabricated by FsLDW.The resultant 3 D SU-8 compound eye templates could be used to replicate polydimethylsiloxane(PDMS)compound eyes many times(over 50 times)with a highly improved efficiency(nearly 20 times higher than the efficiency of direct fabrication using the point-by-point FsLDW).The PDMS replicas showed good focusing and imaging performances.We anticipate that this method may serve as an enabler for the mass production of 3 D artificial compound eyes and promote their practical applications in the near future. 展开更多
关键词 Compound eyes Two-photon polymerization Femtosecond laser PDMS casting
下载PDF
Selective laser trabeculoplasty in pseudophakic and phakic eyes:a prospective study
3
作者 Myrjam De Keyser Maya De Belder Veva De Groot 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期593-598,共6页
AIM:To compare the efficacy of selective laser trabeculoplasty(SLT) in replacing medical therapy in pseudophakic and phakic eyes.METHODS:Subgroup of a prospective randomized clinical trial including patients with ... AIM:To compare the efficacy of selective laser trabeculoplasty(SLT) in replacing medical therapy in pseudophakic and phakic eyes.METHODS:Subgroup of a prospective randomized clinical trial including patients with primary open angle glaucoma or ocular hypertension controlled with medication.Of 38 pseudophakic eyes were matched with 38 phakic eyes.SLT was offered as a way to decrease medication while maintaining the same low eye pressure.SLT was performed over 360°,at 3ns,spotsize 400 μm,100 spots.Data [intraocular pressure(IOP),number of medications needed] were measured at 1h,1wk,1,3,6 and 12 mo.An independent-samples t-test was performed to compare baseline characteristics of the phakic and the pseudophakic group and differences in evolution of mean IOP and number of used medications.Chi-squared analysis was performed to investigate proportions of fast,slow and non-responders.RESULTS:The mean IOP measurement was 13.00± 2.88 mm Hg in the phakic group(38 eyes) and 13.51±3.06 mm Hg in the pseudophakic group(38 eyes)(P〉0.05).This changed little after SLT and IOP lowering effect was comparable between the two groups.Main aim however was to lower the amount of medication needed.In the phakic group medication lowered from 1.29±0.62 at baseline,to 0.15±0.46 after 12mo;a reduction of 88.37%.In the pseudophakic group,used medication changed from 1.71±1.04,to 0.41±0.61;a 76.02% reduction.The differences were not statistically significant at any time point(P〉0.05).IOP lowering occurred slightly faster in thepseudophakic group(50% of patients after one week) than in the phakic group(68% of patients after more than 4wk).The difference was not significant(P〉0.05).CONCLUSION:IOP lowering effect of SLT is comparable between phakic and pseudophakic eyes. 展开更多
关键词 mechanism of trabeculoplasty selective laser trabeculoplasty pseudophakes versus phakic eyes open angle glaucoma pressure lowering after lens extraction
下载PDF
POTENTIAL SAFE TERMINATION BY LASER ABLATION OF HIGH Z IMPURITY IN THE HL-1M TOKAMAK
4
作者 ZHENG Yongzhen, FENG Xingya,GUO Gancheng, XU Deming, DENG Zhongchao (Southwestern Institute of Physics, Chengdu 610041) 《核聚变与等离子体物理》 CAS CSCD 北大核心 2003年第3期147-152,共6页
A preliminary experiment for triggering a plasma current quench by high Z impurities has been performed on the HL1M tokamak.Using injection of impurity with the higher charge of the nuclei allows us to increase ... A preliminary experiment for triggering a plasma current quench by high Z impurities has been performed on the HL1M tokamak.Using injection of impurity with the higher charge of the nuclei allows us to increase the radiation cooling.It can be a simple and potential approach for decreasing significantly the plasma thermal energy before a disruption and for safe termination of the plasma. 展开更多
关键词 等离子体 激光消融 高Z杂质 HL-1M装置 托卡马克装置 分裂
下载PDF
Efficient continuous-wave eye-safe region signal output from intra-cavity singly resonant optical parametric oscillator
5
作者 李斌 丁欣 +6 位作者 盛泉 殷苏嘉 史春鹏 李雪 禹宣伊 温午麒 姚建铨 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第1期230-233,共4页
We report an efficient continuous-wave (CW) tunable intra-cavity singly resonant optical parametric oscillator based on the multi-period periodically poled lithium niobate and using a laser diode (LD) end-pumped C... We report an efficient continuous-wave (CW) tunable intra-cavity singly resonant optical parametric oscillator based on the multi-period periodically poled lithium niobate and using a laser diode (LD) end-pumped CW 1064 nm Nd:YVO4 laser as the pump source. A highly efficiency CW operation is realized through a careful cavity design for mode matching and thermal stability. The signal tuning range is 1401 1500 nm obtained by varying the domain period. The maximum output power of 2.2 W at 1500 nm is obtained with a 17.1 W 808 nm LD power and the corresponding conversion efficiency is 12.9%. 展开更多
关键词 CONTINUOUS-WAVE intracavity optical parametric oscillator periodically poled lithiumniobate tunable eye-safe laser
下载PDF
Corneal neuromediator profiles following laser refractive surgery 被引量:8
6
作者 Lily Wei Yun Yang Jodhbir S.Mehta Yu-Chi Liu 《Neural Regeneration Research》 SCIE CAS CSCD 2021年第11期2177-2183,共7页
Laser refractive surgery is one of the most commonly performed procedures worldwide.In laser refractive surgery,Femtosecond Laser in Situ Keratomileusis and Refractive Lenticule Extraction have emerged as promising al... Laser refractive surgery is one of the most commonly performed procedures worldwide.In laser refractive surgery,Femtosecond Laser in Situ Keratomileusis and Refractive Lenticule Extraction have emerged as promising alternatives to microkeratome Laser in Situ Keratomileusis and Photorefractive Keratectomy.Following laser refractive surgery,the corneal nerves,epithelial and stromal cells release neuromediators,including neurotrophins,neuropeptides and neurotransmitters.Notably,nerve growth factor,substance P,calcitonin gene-related peptide and various cytokines are important mediators of neurogenic inflammation and corneal nerve regeneration.Alterations in neuromediator profiles and ocular surface parameters following laser refractive surgery are attributed to the surgical techniques and the severity of tissue insult induced.In this review,we will discuss the(1)Functions of neuromediators and their physiological and clinical significance;(2)Changes in the neuromediators following various laser refractive surgeries;(3)Correlation between neuromediators,ocular surface health and corneal nerve status;and(4)Future directions,including the use of neuromediators as potential biomarkers for ocular surface health following laser refractive surgery,and as adjuncts to aid in corneal regeneration after laser refractive surgery. 展开更多
关键词 CORNEA corneal nerves dry eye femtosecond laser laser in situ keratomileusis neuromediator refractive surgery small incision lenticule extraction
下载PDF
Comparison of the femtosecond Laser and mechanical microkeratome for flap cutting in LASIK 被引量:3
7
作者 Li-Kun Xia Jie Yu +2 位作者 Guang-Rui Chai Dang Wang Yang Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2015年第4期784-790,共7页
· AIM: To compare refractive results, higher-order aberrations(HOAs), contrast sensitivity and dry eye after laser in situ keratomileusis(LASIK) performed with a femtosecond laser versus a mechanical microkeratom... · AIM: To compare refractive results, higher-order aberrations(HOAs), contrast sensitivity and dry eye after laser in situ keratomileusis(LASIK) performed with a femtosecond laser versus a mechanical microkeratome for myopia and astigmatism.·METHODS: In this prospective, non-randomized study,120 eyes with myopia received a LASIK surgery with the Visu Max femtosecond laser for flap cutting, and 120 eyes received a conventional LASIK surgery with a mechanical microkeratome. Flap thickness, visual acuity, manifest refraction, contrast sensitivity function(CSF) curves,HOAs and dry-eye were measured at 1wk; 1, 3, 6mo after surgery.·RESULTS: At 6mo postoperatively, the mean central flap thickness in femtosecond laser procedure was113.05 ±5.89 μm(attempted thickness 110 μm), and148.36 ±21.24 μm(attempted thickness 140 μm) in mechanical microkeratome procedure. An uncorrected distance visual acuity(UDVA) of 4.9 or better was obtained in more than 98% of eyes treated by both methods, a gain in log MAR lines of corrected distance visual acuity(CDVA) occurred in more than 70% of eyes treated by both methods, and no eye lost ≥1 lines of CDVA in both groups. The difference of the mean UDVA and CDVA between two groups at any time post-surgery were not statistically significant(P 】0.05). The postoperative changes of spherical equivalent occurred markedly during the first month in both groups. The total root mean square values of HOAs and spherical aberrations in the femtosecond treated eyes were markedly less than those in the microkeratome treated eyes during 6mo visit after surgery(P 【0.01). The CSF values of the femtosecond treated eyes were also higherthan those of the microkeratome treated eyes at all space frequency(P 【0.01). The mean ocular surface disease index scores in both groups were increased at 1wk, and recovered to preoperative level at 1mo after surgery. The mean tear breakup time(TBUT) of the femtosecond treated eyes were markedly longer than those of the microkeratome treated eyes at postoperative 1, 3mo(P 【0.01).·CONCLUSION: Both the femtosecond laser and the mechanical microkeratome for LASIK flap cutting are safe and effective to correct myopia, with no statistically significant difference in the UDVA, CDVA during 6mo follow-up. Refractive results remained stable after 1mo post-operation for both groups. The femtosecond laser may have advantages over the microkeratome in the flap thickness predictability, fewer induced HOAs, better CSF,and longer TBUT. 展开更多
关键词 laser in situ keratomileusis femtosecond laser FLAP visual acuity higher-order aberrations contrast sensitivity dry eye
下载PDF
Disruption mitigation using laser ablation of high-Z impurities in HL-1M tokamak 被引量:1
8
作者 郑永真 冯兴亚 +2 位作者 郭干城 徐德明 郑银甲 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第9期2053-2057,共5页
A preliminary experiment triggering a plasma current quench by laser ablation of high-Z impurities has been performed in the HL-1M tokamak. The injection of impurities with higher electric charges into tokamak plasmas... A preliminary experiment triggering a plasma current quench by laser ablation of high-Z impurities has been performed in the HL-1M tokamak. The injection of impurities with higher electric charges into tokamak plasmas can increase the radiation cooling of the plasma. Resistive, highly radiating plasma formed prior to the thermal quench can dissipate both the thermal and magnetic energies, which is possibly a simple and potential approach to reducing significantly the plasma thermal energy and magnetic energy before a disruption thereby a safe plasma termination is obtained. 展开更多
关键词 high-Z impurities DISRUPTION safe plasma termination laser ablation
下载PDF
Effect of Laser in situ Keratomileusis on Accommodation 被引量:2
9
作者 刘磊 袁菁 +2 位作者 栗静 李新宇 王渝龙 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第5期596-598,共3页
The accommodative function before and after laser in situ keratomileusis (LASIK) was observed, and the effect of LASIK on accommodation was investigated. In a prospective clinical trial, 48 myopic patients (96 eyes... The accommodative function before and after laser in situ keratomileusis (LASIK) was observed, and the effect of LASIK on accommodation was investigated. In a prospective clinical trial, 48 myopic patients (96 eyes) subject to bilateral LASIK in Refractive Surgery Center, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology (China) from March 2006 to June 2006 were selected and studied. Refractions, accommodative range, amplitude of accommodative response and high frequency component (HFC) of accommodative microfluctuations were measured with NEDIK-730A before and one week and 30 days after operation. Dominant and non-dominant eyes were determined by hole-in-card method. It was found that all of the operative eyes showed an uncorrected visual acuity of 0.8 or better one week postoperatively, and 1.0 or better 30 days postoperatively. Compared with those preoperatively, accommodative range and HFC had no significant difference at first week and 30th day after operation in both dominant eyes and non-dominant eyes (P〉0.05), but there was a significant difference in the amplitude of accommodative response/accommodative stimulus ratio (A/S) after operation (P〈0.01), and no significant difference was found in accommodation between one week and 30 days postoperation. No ocular dominance's change was noted. There was no significant difference in accommodative function between dominant eyes and non-dominant eyes. It was suggested that LASIK produced no significant effect on accommodation. 展开更多
关键词 laser in situ keratomileusis ACCOMMODATION dominant eye
下载PDF
Human eye ocular component analysis for refractive state and refractive surgery 被引量:3
10
作者 Chao-Kai Chang Jui-Teng Lin Yong Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第7期1076-1080,共5页
AIM: To analyze the clinical factors influencing the human vision corrections via the changing of ocular components of human eye in various applications; and to analyze refractive state via a new effective axial leng... AIM: To analyze the clinical factors influencing the human vision corrections via the changing of ocular components of human eye in various applications; and to analyze refractive state via a new effective axial length.METHODS: An effective eye model was introduced by the ocular components of human eye including refractive indexes, surface radius(r1, r2, R1, R2) and thickness(t, T) of the cornea and lens, the anterior chamber depth(S1) and the vitreous length(S2). Gaussian optics was used to calculate the change rate of refractive error per unit amount of ocular components of a human eye(the rate function M). A new criterion of myopia was presented via an effective axial length.RESULTS: For typical corneal and lens power of 42 and 21.9 diopters, the rate function Mj(j=1 to 6) were calculated for a 1% change of r1, r2, R1, R2, t, T(in diopters) M1=+0.485, M2=-0.063, M3=+0.053, M4=+0.091, M5=+0.012, and M6=-0.021 diopters. For 1.0 mm increase of S1 and S2, the rate functions were M7=+1.35, and M8=-2.67 diopter/mm, respectively. These rate functions were used to analyze the clinical outcomes in various applications including laser in situ keratomileusis surgery, corneal cross linking procedure, femtosecond laser surgery and scleral ablation for accommodation.CONCLUSION: Using Gaussian optics, analytic formulas are presented for the change of refractive power due to various ocular parameter changes. These formulas provide useful clinical guidance in refractive surgery and other related procedures. 展开更多
关键词 Gaussian optics human eye ocular components refractive errors vision correction laser in situ keratomileusis corneal collagen crosslinking
下载PDF
Navigation technology/eye-tracking in ophthalmology:principles,applications and benefits-a narrative review 被引量:1
11
作者 Igor Kozak Ulrike Rahn 《Annals of Eye Science》 2021年第1期33-45,共13页
Navigation technology in ophthalmology,colloquially called“eye-tracking”,has been applied to various areas of eye care.This approach encompasses motion-based navigation technology in both ophthalmic imaging and trea... Navigation technology in ophthalmology,colloquially called“eye-tracking”,has been applied to various areas of eye care.This approach encompasses motion-based navigation technology in both ophthalmic imaging and treatment.For instance,modern imaging instruments use a real-time eye-tracking system,which helps to reduce motion artefacts and increase signal-to-noise ratio in imaging acquisition such as optical coherence tomography(OCT),microperimetry,and fluorescence and color imaging.Navigation in ophthalmic surgery has been firstly applied in laser vision corrective surgery and spread to involve navigated retinal photocoagulation,and positioning guidance of intraocular lenses(IOL)during cataract surgery.It has emerged as one of the most reliable representatives of technology as it continues to transform surgical interventions into safer,more standardized,and more predictable procedures with better outcomes.Eye-tracking is essential in refractive surgery with excimer laser ablation.Using this technology for cataract surgery in patients with high preoperative astigmatism has produced better therapeutic outcomes.Navigated retinal laser has proven to be safer and more accurate compared to the use of conventional slit lamp lasers.Eye-tracking has also been used in imaging diagnostics,where it is essential for proper alignment of captured zones of interest and accurate follow-up imaging.This technology is not routinely discussed in the ophthalmic literature even though it has been truly impactful in our clinical practice and represents a small revolution in ophthalmology. 展开更多
关键词 Navigation technology eye tracking imaging:refractive surgery excimer laser cataract surgery navigated retinal laser
下载PDF
Influence of transverse mode on retinal spot size and retinal injury effect:A theoreticalan alysis on 532-nm laser
12
作者 Jia-Rui Wang Guang-Yuan Yu +3 位作者 Zai-Fu Yang Lu-Guang Jiao Hong-Xia Chen Xian-Biao Zou 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2014年第3期31-39,共9页
The fundamental transverse mode(TEM00)is preferable for experimental and theoretical study on the laser-induced retinal injury effect,for it can produce the minimal retinal image andestablish the most strict laser saf... The fundamental transverse mode(TEM00)is preferable for experimental and theoretical study on the laser-induced retinal injury effect,for it can produce the minimal retinal image andestablish the most strict laser safety standards.But actually lasers with higher order mode werefrequently used in both earlier and recent studies.Generally higher order mode leads to largerretinal spot size and so higher damage threshold,but there are few quantitative analyses on thisproblem.In this paper,a four-surface schematic eye model is established for human and macaque.The propagation of 532-nm laser in schematic eye is analyzed by the ABCD law of Gaussianoptics.It is shown that retinal spot size increases with laser transverse mode order.For relativelower mode order,the retinal spot diameter will not exceed the minimum laser-induced retinallesion(25~30μm in diameter),and so has little effect on retinal damage threshold.While forhigher order mode,the larger'retinal spot requires more energy to induce injury and so the damage threshold increases.When beam divergence is lowered,the retinal spot size decreasescorrespondingly,so the efect of mode order can be compensated.The retinal spot size of macaqueis slightly smaller than that of human and the ratio bet ween them is independent of mode order.We conclude that the laser mode order has significant influence on retinal spot size but limitedinfluence on the retinal injury ffect. 展开更多
关键词 laser transverse mode four-surface schematic eye retinal spot size retinal injuryeffect.
下载PDF
Diode Laser Cyclophotocoagulation in the Management of Pain and Intraocular Pressure Control in Patients with Terminal Glaucoma--Six Years’Experience
13
作者 Silvestre Cruz Diogo Cabral +4 位作者 Filipe Braz Ana Vide Escada Jorge Godinho Ferreira José Fernandes Joao Segurado 《Open Journal of Ophthalmology》 2017年第2期88-94,共7页
Objective: This study aims to describe the experience with diode laser cyclophotocoagulation in the control of intraocular pressure and resolution of pain in patients with refractory glaucoma. Methods: Retrospective s... Objective: This study aims to describe the experience with diode laser cyclophotocoagulation in the control of intraocular pressure and resolution of pain in patients with refractory glaucoma. Methods: Retrospective study. 64 eyes of 60 patients who underwent cyclophotocoagulation between January 2008 and March 2014. Evaluation of the pre- and post-operative intraocular pressure, the control of ocular pain, the number of anti-glaucoma drugs used in pre- and post-intervention, the rate of complications and the success rate. Results: There was an overall success rate of 81.3%, with 9 eyes needing a second intervention. There was a mean reduction of 52.6% of the preoperative mean intraocular pressure of 41.25 to 19.56 mmHg at 12 months observation (p < 0.001). There was also a statistically significant reduction in the number of anti-glaucoma drugs used from 3.19 to 2.01 per eye and the resolution of pain in 75% of patients. Conclusions: cyclophotocoagulation is an effective procedure, with an expected positive impact on quality of life of patients as a result from the decreased number of anti-glaucoma drugs, sustained intraocular pressure reduction and resolution of pain. 展开更多
关键词 Diode laser Cyclophotocoagulation GLAUCOMA Painful eye Intraocular Pressure Quality of Life
下载PDF
Measuring Method of Radius of Curvature Based on Dual-Frequency Laser Interferometer
14
作者 Wenlong Zhang Liang Miao Yu Liu 《Optics and Photonics Journal》 2016年第8期209-214,共6页
In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferome... In order to achieve high-accuracy measurement of radius of curvature of optical sphere, ultra-high accuracy radius of curvature testing device is developed by dual-frequency laser interferometer and Fizeau interferometer based on cat’s eye and confocal method. Through analyzing the error source models of radius of curvature testing, optical configuration of the testing device has been optimized. Precise environment control and real-time monitoring system is also established to reduce the errors caused by environment. Through the above processes, the radius of curvature measurement relative accuracy is better than 2 ppm. One optical sphere, R88.5 mm, test aperture 59 mm, has been tested. Testing result is 88499.465 ± 0.176 μm, meeting the design requirement. The method has high accuracy and practical advantages. 展开更多
关键词 Radius of Curvature Cat’s eye and Confocal Method Dual-Frequency laser Interferometer
下载PDF
脉冲激光测距光源进展 被引量:15
15
作者 霍玉晶 杨成伟 陈千颂 《激光与红外》 CAS CSCD 北大核心 2002年第3期131-134,共4页
简要介绍用于激光测距的各种光源 :Nd∶YAG激光器、CO2 激光器、Er∶glass激光器、喇曼频移Nd∶YAG激光器、OPO激光器和半导体激光器 ,并对它们的研究进展和应用前景进行了阐述。
关键词 脉冲激光 激光测距仪 光源 人眼安全
下载PDF
人眼安全1.57μm OPO激光测距机 被引量:6
16
作者 时顺森 翟刚 +5 位作者 金锋 李晶 马楠 曹良奎 彭绪金 田子文 《激光技术》 CAS CSCD 北大核心 2000年第5期262-264,共3页
研制成功人眼安全 1.57μmOPO激光测距机 ,并进行了室外测距实验 ,在能见度V约10km时测到 70 50m远处的烟囱 ,测距精度± 5m ,重复频率达 2 0 pps。该测距机采用紧凑小型的水冷灯泵电光调Q (Ce ,Nd)∶YAG激光器泵浦磷酸钛氧钾 (KTP)... 研制成功人眼安全 1.57μmOPO激光测距机 ,并进行了室外测距实验 ,在能见度V约10km时测到 70 50m远处的烟囱 ,测距精度± 5m ,重复频率达 2 0 pps。该测距机采用紧凑小型的水冷灯泵电光调Q (Ce ,Nd)∶YAG激光器泵浦磷酸钛氧钾 (KTP) 1.57μm单谐振OPO器件 ,输出12mJ ,脉宽~ 6ns。接收元件选用铟镓砷 (InGaAs)PIN探测器。 展开更多
关键词 人眼安全 OPO 激光测距机 YAG
下载PDF
1.57μm内腔光学参量振荡器研究 被引量:4
17
作者 金锋 时顺森 +2 位作者 翟刚 李晶 马楠 《红外与激光工程》 EI CSCD 北大核心 2002年第1期48-50,67,共4页
对内腔光学参量振荡器的工作机理进行了简要分析 ,报道了一种高效、紧凑的 1.5 7μm人眼安全内腔光学参量振荡器的实验结果。它的泵浦源为水冷闪光灯泵浦KD P电光调Q (Ce ,Nd) :YAG激光器 ,采用KTPⅡ类非临界相位匹配 ,输出信号光脉冲... 对内腔光学参量振荡器的工作机理进行了简要分析 ,报道了一种高效、紧凑的 1.5 7μm人眼安全内腔光学参量振荡器的实验结果。它的泵浦源为水冷闪光灯泵浦KD P电光调Q (Ce ,Nd) :YAG激光器 ,采用KTPⅡ类非临界相位匹配 ,输出信号光脉冲能量最高达 87.7mJ ,脉宽约7ns ,重复频率为 10Hz ,总电光效率最高达 5 .8‰ ,器件外形尺寸为 4 10mm× 130mm× 80mm。 展开更多
关键词 光学参量振荡器 人眼安全激光器 内腔激光器
下载PDF
高速公路车辆防追尾碰撞系统的设计与控制研究 被引量:14
18
作者 尹小琴 朱喜行 张盼盼 《汽车工程》 EI CSCD 北大核心 2014年第9期1080-1084,1116,共6页
针对汽车追尾碰撞事故频发和事故中驾乘人员头颈部易受损伤等问题,利用激光雷达测距和机电控制相结合的技术,提出了一种车辆防追尾碰撞系统,对高位制动灯和主动式头枕进行控制。首先利用激光雷达和本车状态信息对行车环境进行预测;接着... 针对汽车追尾碰撞事故频发和事故中驾乘人员头颈部易受损伤等问题,利用激光雷达测距和机电控制相结合的技术,提出了一种车辆防追尾碰撞系统,对高位制动灯和主动式头枕进行控制。首先利用激光雷达和本车状态信息对行车环境进行预测;接着对后车分液压和气压两种制动形式进行行车安全车距的分析,推导出临界安全车距的计算公式;最后通过AT89C51单片机系统预设的程序,将实际行车间距与临界安全车距进行比较,并据此控制高位制动灯的开闭和主动式头枕控制系统的执行。所提出的方法有较好的工程实用性。 展开更多
关键词 追尾碰撞 设计 控制 激光雷达 安全车距
下载PDF
Nd:GYSGG/YVO_4双波长人眼安全波段内腔拉曼激光器 被引量:5
19
作者 王慧 张会峰 郭涛 《红外与激光工程》 EI CSCD 北大核心 2015年第12期3512-3516,共5页
以Nd:GYSGG晶体为激光增益介质,a切割YVO4晶体为拉曼增益介质,利用Nd:GYSGG晶体的双波长激光运转特性实现声光调Q 1.5μm人眼安全波段双波长内腔拉曼激光器。为克服Nd:GYSGG晶体严重的热透镜效应对激光器功率的限制,实验确定其同带泵浦... 以Nd:GYSGG晶体为激光增益介质,a切割YVO4晶体为拉曼增益介质,利用Nd:GYSGG晶体的双波长激光运转特性实现声光调Q 1.5μm人眼安全波段双波长内腔拉曼激光器。为克服Nd:GYSGG晶体严重的热透镜效应对激光器功率的限制,实验确定其同带泵浦吸收峰位置及吸收系数,采用同带泵浦方式减轻热效应。吸收882.9 nm泵浦光功率17.1 W时,在20 k Hz的脉冲重复频率下获得1.44 W的1.5μm双波长输出,转换效率8.4%,光束质量因子M2=2.4;棱镜分光测得其中1 497 nm和1 516 nm功率分别为0.55 W和0.89 W,二者脉冲宽度相近,均为15.3 ns左右。与808 nm传统泵浦相比,同带泵浦方式下激光器的输出功率及光束质量均得到明显提升。 展开更多
关键词 双波长激光器 拉曼激光器 人眼安全波段
下载PDF
人眼安全的生物气溶胶短程遥测系统 被引量:2
20
作者 李抄 杨子健 +2 位作者 杜耀华 吴太虎 陈锋 《光学精密工程》 EI CAS CSCD 北大核心 2016年第7期1600-1606,共7页
建立了满足激光辐照人眼安全要求的便携式生物气溶胶短程遥测系统,用于实现有人员活动区域生物战剂气溶胶的实时预警监测。以高频调制的405nm半导体激光器为激发光源,200mm口径的卡塞格林望远系统为信号光收集系统,搭建了基于伪随机调... 建立了满足激光辐照人眼安全要求的便携式生物气溶胶短程遥测系统,用于实现有人员活动区域生物战剂气溶胶的实时预警监测。以高频调制的405nm半导体激光器为激发光源,200mm口径的卡塞格林望远系统为信号光收集系统,搭建了基于伪随机调制的便携型生物气溶胶激光雷达短程遥测系统。该系统具备平行偏振散射、垂直偏振散射光探测,以及450nm和530nm两个波段荧光探测等四个同步探测通道。以枯草芽孢杆菌、金黄色葡萄球菌和酵母菌为样本对该激光雷达系统进行了初步测试。外场试验表明,该生物气溶胶遥测系统的空间分辨率为1.5m,荧光通道的探测距离为100m;3种被测生物气溶胶种类识别的回代误报率分别为9%、11.5%和14.5%,交叉误报率为11.3%。该遥测系统的激光能量低于激光辐照人眼安全标准的要求,基本实现了生物气溶胶的甄别。 展开更多
关键词 激光雷达 生物气溶胶 激光辐照 人眼安全 伪随机调制
下载PDF
上一页 1 2 7 下一页 到第
使用帮助 返回顶部