A capsulated microdose 14C-urea breath test (14C-UBT) was developed to detect Helicobacter pylori (HP) infection in 137 patients (54 HP negative and 83 HP positive individuals)to whom a single dose of 3. 7x 104 Bq of...A capsulated microdose 14C-urea breath test (14C-UBT) was developed to detect Helicobacter pylori (HP) infection in 137 patients (54 HP negative and 83 HP positive individuals)to whom a single dose of 3. 7x 104 Bq of 14C-urea in a capsule was given. Samples of exhaled gas were collected at the sib, 10th, 15th. 20th, 25th, 30th, 45th and 60th minute after the administration and the peak value of exhaled 14CO2 was found in the samples collected at the 25th minute. This peak value was taken as the measuring point and directly expressed as Bq/mmol CO2 to develop a new detecting method. Then its results were compared with those of HP culture and histological examination. It was found that the samples collected on the 25th minute showed a sensitivity of 97. 06%, specificity of 95. 12%, positive predictive value of 97. 06% and negative predictive value of 95. 12% respectively when the mean value of 14CO2 in HP negative subjects ±3s on the 25th minute was taken as the critical value. This suggests that the capsule-based microdose 14C-UBT may replace conventional 14C-UBT using a larger dose of (1. 85-3. 7)x 105 Bq for it is non-invasive, safe, rapid, accurate, simple and economic.展开更多
文摘A capsulated microdose 14C-urea breath test (14C-UBT) was developed to detect Helicobacter pylori (HP) infection in 137 patients (54 HP negative and 83 HP positive individuals)to whom a single dose of 3. 7x 104 Bq of 14C-urea in a capsule was given. Samples of exhaled gas were collected at the sib, 10th, 15th. 20th, 25th, 30th, 45th and 60th minute after the administration and the peak value of exhaled 14CO2 was found in the samples collected at the 25th minute. This peak value was taken as the measuring point and directly expressed as Bq/mmol CO2 to develop a new detecting method. Then its results were compared with those of HP culture and histological examination. It was found that the samples collected on the 25th minute showed a sensitivity of 97. 06%, specificity of 95. 12%, positive predictive value of 97. 06% and negative predictive value of 95. 12% respectively when the mean value of 14CO2 in HP negative subjects ±3s on the 25th minute was taken as the critical value. This suggests that the capsule-based microdose 14C-UBT may replace conventional 14C-UBT using a larger dose of (1. 85-3. 7)x 105 Bq for it is non-invasive, safe, rapid, accurate, simple and economic.