期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
A cryogenic radio-frequency ion trap for a 40Ca^(+) optical clock
1
作者 曾孟彦 黄垚 +6 位作者 张宝林 马子晓 郝艳梅 胡如明 张华青 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第11期232-239,共8页
A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the li... A liquid-nitrogen cryogenic40Ca^(+)optical clock is presented that is designed to greatly reduce the blackbody radiation(BBR) shift. The ion trap, the electrodes and the in-vacuum BBR shield are installed under the liquid-nitrogen container,keeping the ions in a cryogenic environment at liquid-nitrogen temperature. Compared with the first design in our previous work, many improvements have been made to increase the performance. The liquid-nitrogen maintenance time has been increased by about three times by increasing the volume of the liquid-nitrogen container;the trap position recovery time after refilling the liquid-nitrogen container has been decreased more than three times by using a better fixation scheme in the liquid-nitrogen container;and the magnetic field noise felt by the ions has been decreased more than three times by a better design of the magnetic shielding system. These optimizations make the scheme for reducing the BBR shift uncertainty of liquid-nitrogen-cooled optical clocks more mature and stable, and develop a stable lock with a narrower linewidth spectrum,which would be very beneficial for further reducing the overall systematic uncertainty of optical clocks. 展开更多
关键词 cryogenics ion trapping ^40Ca^(+)optical clock
下载PDF
Progress on the^40Ca^+ion optical clock
2
作者 张宝林 黄垚 +4 位作者 张华青 郝艳梅 曾孟彦 管桦 高克林 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第7期69-76,共8页
Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scal... Progress of the ^40Ca^+ion optical clock based on the 4^2S1/2-3d ^2D5/2 electric quadrupole transition is reported.By setting the drive frequency to the“magic”frequencyΩ0,the frequency uncertainty caused by the scalar Stark shift and second-order Doppler shift induced by micromotion is reduced to the 10^-19 level.By precisely measuring the differential static scalar polarizability∆α0,the uncertainty due to the blackbody radiation(BBR)shift(coefficient)is reduced to the 10^-19 level.With the help of a second-order integrating servo algorithm,the uncertainty due to the servo error is reduced to the 10^-18 level.The total fractional uncertainty of the ^40Ca^+ion optical clock is then improved to 2.2×10^-17,whereas this value is mainly restricted by the uncertainty of the BBR shift due to temperature fluctuations.The state preparation is introduced together with improvements in the pulse sequence,and furthermore,a better signal to noise ratio(SNR)and less dead time are achieved.The clock stability of a single clock is improved to 4.8×10^-15√τ(in seconds). 展开更多
关键词 ^^40Ca^+ion optical clocks “magic”drive frequency frequency uncertainty frequency stability
下载PDF
Experimental Improvement of Signal of a Single Laser-Cooled Trapped ^40Ca^+ Ion
3
作者 舒华林 离彬 +3 位作者 管桦 刘曲 黄学人 高克林 《Chinese Physics Letters》 SCIE CAS CSCD 2007年第5期1217-1219,共3页
A single ^40Ca^+ ion is loaded in a miniature Paul trap and the probability of directly loading a single ion is above 50%. The signal-to-noise ratio and the storage time for a single ion have been improved by minimiz... A single ^40Ca^+ ion is loaded in a miniature Paul trap and the probability of directly loading a single ion is above 50%. The signal-to-noise ratio and the storage time for a single ion have been improved by minimizing the ion micromotion and locking a 397nm cooling laser to a Fabry-Perot interferometer and optogalvanic signal. From the fluorescence spectrum, the ion temperature is estimated to be about 5mK. 展开更多
关键词 ^^40Ca^+ ion ^^40Ca^+ ion
下载PDF
高准确度的钙离子光频标 被引量:3
4
作者 管桦 黄垚 +1 位作者 李承斌 高克林 《物理学报》 SCIE EI CAS CSCD 北大核心 2018年第16期155-164,共10页
近年来,冷原子技术和激光技术促进了高精度光频标的发展,有望在建立时间基准、推动基础研究和满足国家需求等方面发挥重要的作用.本文介绍了中国科学院武汉物理与数学研究所近年来在高准确度钙离子(^(40)Ca^+)光频标研究方面的进展:采... 近年来,冷原子技术和激光技术促进了高精度光频标的发展,有望在建立时间基准、推动基础研究和满足国家需求等方面发挥重要的作用.本文介绍了中国科学院武汉物理与数学研究所近年来在高准确度钙离子(^(40)Ca^+)光频标研究方面的进展:采用新的ULE腔系统,实现了729 nm钟跃迁激光器1—100 s的频率稳定度均优于2×10^(-15),通过对外场和环境效应的控制及克服,特别是囚禁离子运动效应的抑制,获得单个钙离子光频标的不确定度优于5.5×10^(-17);通过两台光频标的比对,测得20000 s的稳定度也进入10^(-17)量级;基于高精度钙离子光频标平台,进行了相关精密测量的工作,包括:基于全球定位系统的超高精度远程光频绝对值测量方案,第二次测量了钙离子的光频跃迁绝对值,该测量结果再次被国际时间频率咨询委员会采纳,更新了钙离子的频率推荐值;精确测量了钙离子的钟跃迁魔幻波长,由此提出新型的全光囚禁离子光频标的方法;精密测量了钙离子的亚稳态寿命等参数.以上工作推动了基于冷原子的精密测量工作. 展开更多
关键词 光频标 精密测量 钙离子 魔幻波长
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部