期刊文献+
共找到28篇文章
< 1 2 >
每页显示 20 50 100
Nonlinear polarization rotation-induced pulse shaping in a stretched-pulse ytterbium-doped fiber laser
1
作者 白东碧 李文雪 +3 位作者 杨康文 沈旭玲 陈修亮 曾和平 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第10期155-161,共7页
We report on controllable pulse shaping in a Yb-doped stretched-pulse fiber laser followed by a high-power chirped pulse amplifier. We demonstrate that the pulses after an extra-cavity grating pair change their intens... We report on controllable pulse shaping in a Yb-doped stretched-pulse fiber laser followed by a high-power chirped pulse amplifier. We demonstrate that the pulses after an extra-cavity grating pair change their intensity profile from Lorentz to Gaussian and then to sech2 shapes by adjusting the intra-cavity polarization through a quarter-wave plate inside the fiber laser cavity. The laser pulses with different pulse shapes exhibit pulse-to-pulse amplitude fluctuation of -- 1.02%, while the sech2-shaped pulse train is provided with a more stable free-running repetition rate as a result of the stronger self-phase modulation in the fiber laser cavity than Lorentz- and Gaussian-shaped pulse trains. 展开更多
关键词 fiber lasers nonlinear optics mode locking pulse generators
下载PDF
TRULY BALANCED PULSE GENERATOR USING MICROWAVE TRANSISTOR AND SRD 被引量:1
2
作者 Xie Yifang Xiong Weiming 《Journal of Electronics(China)》 2011年第1期141-144,共4页
A novel efficient circuit for Ultra-WideBand(UWB) balanced sub-nanosecond monocycle pulse generation is presented.The pulse generator employs wideband bipolar transistor,step recovery diodes,Schottky diodes,and simple... A novel efficient circuit for Ultra-WideBand(UWB) balanced sub-nanosecond monocycle pulse generation is presented.The pulse generator employs wideband bipolar transistor,step recovery diodes,Schottky diodes,and simple charging and discharging circuitry.Simple transient analysis and design of the circuit are presented along with their operating principle.The pulse generator produces truly balanced monocycle pulse with 500 ps pulse-width and 800 mV peak voltage.The generated monocycle pulse also has very symmetrical positive and negative portions and low ringing level.The presented pulse generator can be used as both a transmitter feeding UWB balanced antennas without broadband baluns and a balanced switching pulse generator that used in UWB receiver. 展开更多
关键词 Balanced monocycle pulse generator Ultra-WideBand(UWB) Microwave bipolar transistor Step Recovery Diode(SRD)
下载PDF
CONTROL STRATEGY FOR ELECTRO-HYDRAULIC POSITION SERVO SYSTEM WITH GENERALIZED PULSE CODE MODULATION 被引量:1
3
作者 LIU Rong PAN Huachen CHEN Ying 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第3期50-53,共4页
A hybrid control strategy has been designed and developed for the electro-hydraulic posi-tion servo control system with generalized Pulse code modulation (GPCM), which is suitable for the area where the work conditi... A hybrid control strategy has been designed and developed for the electro-hydraulic posi-tion servo control system with generalized Pulse code modulation (GPCM), which is suitable for the area where the work condition is poor and a large flow rate is required. It is difficult to control the GPCM system because the system is discrete. With consideration of the stability and speediness of the GPCM position servo control system, a control strategy is developed through the theoretical and ex-perimental analyses. The control strategy integrates the merits of Bang-Bang control, PID control and fuzzy control. With this hybrid control strategy, the electro hydraulic control system has good per-formances, and the servo control is carried out with GPCM through on-off valves. 展开更多
关键词 Generalized pulse code modulation (GPCM) Position control Electro hydraulic control
下载PDF
The Influence of Electrode Surface Mercury Film Deformation on the Breakdown Voltage of a Sub-Nanosecond Pulse Discharge Tube
4
作者 翁明 徐伟军 王瑞 《Plasma Science and Technology》 SCIE EI CAS CSCD 2012年第11期1024-1029,共6页
A sub-nanosecond pulse discharge tube is a gas discharge tube which can generate a rapid high-voltage pulse of kilo-volts in amplitude and sub-nanoseconds in width. In this paper, the sub-nanosecond pulse discharge tu... A sub-nanosecond pulse discharge tube is a gas discharge tube which can generate a rapid high-voltage pulse of kilo-volts in amplitude and sub-nanoseconds in width. In this paper, the sub-nanosecond pulse discharge tube and its working principles are described. Because of the phenomenon that the deformation process of the mercury film on the electrode surface lags behind the charging process, the mercury film deformation process affects the dynamic breakdown voltage of the tube directly. The deformation of the mercury film is observed microscopically, and the dynamic breakdown voltage of the tube is messured using an oscillograph. The results show that all the parameters in the charging process, such as charging resistance, charging capacitance and DC power supply, affect the dynamic breakdown voltage of the tube. Based on these studies, the output pulse amplitude can be controlled continuously and individually by adjusting the power supply voltage. When the DC power supply is adjusted from 7 kV to 10 kV, the dynamic breakdown voltage ranges from 6.5 kV to 10 kV. According to our research, a kind of sub-nanosecond pulse generator is made, with a pulse width ranging from 0.5 ns to 2.5 ns, a rise time from 0.32 ns to 0.58 ns, and a pulse amplitude that is adjustable from 1.5 kV to 5 kV. 展开更多
关键词 sub-nanosecond pulse generator mercury film deformation gas discharge breakdown voltage pulse parameter
下载PDF
Sub-ns Jitter, 1ns Risetime and 10 kV Rectangular Pulse Trigger Generator
5
作者 王海洋 马连英 曾正中 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第5期600-601,共2页
A new rectangular pulse trigger generator has been developed which can generate two 10 kV pulses with a risetime less than 1 ns, a jitter of 0.2 ns and a width of about 10 ns and 40 ns, respectively. This generator us... A new rectangular pulse trigger generator has been developed which can generate two 10 kV pulses with a risetime less than 1 ns, a jitter of 0.2 ns and a width of about 10 ns and 40 ns, respectively. This generator uses two polymer-foil switches and 25 ohm Blumlein transmission lines composed of two-parallel standard coaxial cables discharging into two 50 ohm output cables. The pulse width and the delay between two pulses can be adjusted by changing the length of the cables. 展开更多
关键词 rectangular pulse generator polymer-foil switch delay JITTER
下载PDF
Quantum path control and isolated attosecond pulse generation in the combination of near-infrared and terahertz pulses
6
作者 钟慧英 郭静 +2 位作者 张宏丹 杜慧 刘学深 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期207-210,共4页
We present an efficient and realizable scheme for the generation of an ultrashort single attosecond(as) pulse from H atom with a 800-nm fundamental laser field combined with a terahertz(THz) field. The high-order ... We present an efficient and realizable scheme for the generation of an ultrashort single attosecond(as) pulse from H atom with a 800-nm fundamental laser field combined with a terahertz(THz) field. The high-order harmonic generation(HHG) can be obtained by solving the time-dependent Schr dinger equation accurately and efficiently with time-dependent generalized pseudo-spectral(TDGPS) method. The result shows that the plateau of high-order harmonics is extended and the broadband spectra can be produced by the combined laser pulse, which can be explained by the corresponding ionization probability. The time–frequency analysis and semi-classical three-step model are also presented to further investigate this mechanism. Besides, by the superposition of the harmonics near the cutoff region, an isolated 133-as pulse can be obtained. 展开更多
关键词 high-order harmonic generation generalized pseudospectral method attosecond pulse
下载PDF
Clinical outcomes of sacral neuromodulation in non-neurogenic,non-obstructive dysuria:A 5-year retrospective,multicentre study in China 被引量:1
7
作者 Ling-Feng Meng Wei Zhang +11 位作者 Jian-Ye Wang Yao-Guang Zhang Peng Zhang Li-Min Liao Jian-Wei Lv Qing Ling Zhong-Qing Wei Tie Zhong Zhi-Hui Xu Wei Wen Jia-Yi Li De-Yi Luo 《World Journal of Clinical Cases》 SCIE 2020年第12期2494-2501,共8页
BACKGROUND Management of non-neurogenic,non-obstructive dysuria represents one of the most challenging dilemmas in urological practice.The main clinical symptom is the increase in residual urine.Voiding dysfunction is... BACKGROUND Management of non-neurogenic,non-obstructive dysuria represents one of the most challenging dilemmas in urological practice.The main clinical symptom is the increase in residual urine.Voiding dysfunction is the main cause of dysuria or urinary retention,mainly due to the decrease in bladder contraction(the decrease in contraction amplitude or duration)or the increase in outflow tract resistance.Sacral neuromodulation(SNM)has been used for>10 years to treat many kinds of lower urinary tract dysfunction.It has become increasingly popular in China in recent years.Consequently,studies focusing on nonneurogenic,non-obstructive dysuria patients treated by SNM are highly desirable.AIM To assess the outcome of two-stage SNM in non-neurogenic,non-obstructive dysuria.METHODS Clinical data of 54 patients(26 men,28 women)with non-neurogenic,nonobstructive dysuria treated by SNM from January 2012 to December 2016 in ten medical centers in China were retrospectively analyzed.All patients received two or more conservative treatments.The voiding diary,urgency score,and quality of life score before operation,after implantation of tined lead in stage I(test period),and during short-term follow-up(latest follow-up)after implantation of the implanted pulse generator in stage II were compared to observe symptom improvements.RESULTS Among the 54 study patients,eight refused to implant an implanted pulse generator because of the unsatisfactory effect,and 46 chose to embed the implanted pulse generator at the end of stage I.The conversion rate of stage I to stage II was 85.2%.The average follow-up time was 18.6 mo.There were significant differences between baseline(before stage I)and the test period(after stage I)in residual urine,voiding frequency,average voiding amount,maximum voiding amount,nocturia,urgency score,and quality of life score.The residual urine and urgency score between the test period and the latest follow-up time(after stage II)were also significantly different.No significant differences were observed for other parameters.No wound infection,electrode breakage,or other irreversible adverse events occurred.CONCLUSION SNM is effective for patients with non-neurogenic,non-obstructive dysuria showing a poor response to traditional treatment.The duration of continuous stimulation may be positively correlated with the improvement of residual urine. 展开更多
关键词 DYSURIA Implanted pulse generator Non-neurogenic NON-OBSTRUCTIVE Sacral neuromodulation
下载PDF
ANALYSIS AND SIMULATION ON THE MECHANISM OF A NOVEL DUAL-WAVE SHOCK TEST MACHINE 被引量:3
8
作者 WANG Gongxian ZHANG Zhiyi +1 位作者 CHU Deying SHEN Rongying 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第1期94-100,共7页
For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test ... For qualifying the anti-shock performance of shipboard equipments and simulating actual underwater explosion environments, a novel dual-wave shock test machine is proposed to increase testing capability of shock test machines as well as to meet certain shock testing specification. The machine can generate a double-pulse acceleration shock for test articles according to specification defined in BV043/85. On the basis of the impact theory, a nonlinear dynamic model of the hydraulically-actuated test machine is established with thorough analysis on its mechanism which involves conversion of gas potential energy and dissipation of kinetic energy. Simulation results have demonstrated that the machine can produce a double-pulse acceleration shock in the time domain or a desired shock response spectrum in the frequency domain, which sets a theoretical base for the construction of the proposed machine. 展开更多
关键词 Shock test machine Underwater explosion Velocity generator pulse generator
下载PDF
THEORY AND EXPERIMENT ON THE VISCOUS HEATING OF FLUID DAMPER UNDER SHOCK ENVIRONMENT 被引量:2
9
作者 CHU Deying ZHANG Zhiyi +2 位作者 WANG Gongxian HUA Hongxing WANG Yu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第3期66-71,共6页
A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based ... A specially designed fluid damper used as negative shock pulse generator in the shock resistance test system to dissipate the shock input energy in transient time duration is presented. The theoretical modeling based on the three-dimensional equation of heat transfer through a fluid element is created to predict the viscous heating in the fluid damper under shock conditions. A comprehensive experimental program that investigates the problem of viscous heating in the fluid damper under different shock conditions is conducted on the shock test machine to validate the analytical expression. Temperature histories for the fluid within the damper at two locations, the annular-oriflce and the-end-of stroke of the damper, are recorded. The experimental results show that the theoretical model can offer a very dependable prediction for the temperature histories in the damper for increasing input velocity. The theoretical model and experimental data both clearly indicate that the viscous heating in the damper is directly related to the maximum shock velocity input and the pressure between the two sides of the piston head. 展开更多
关键词 Fluid damper Negative shock pulse generator Viscous heating Shock conditions
下载PDF
Modeling and Simulation of a Gas-Liquid Coupling Excitation-Induced Cavitation Bubble
10
作者 张慧贤 苗灵霞 《Journal of Donghua University(English Edition)》 EI CAS 2017年第4期545-550,共6页
A gas-liquid coupling excitation mode is proposed and the gas-liquid excitation experimental system is developed. Air from pulse generator is mixed with liquid,through which the generated cavitation bubbles can strip ... A gas-liquid coupling excitation mode is proposed and the gas-liquid excitation experimental system is developed. Air from pulse generator is mixed with liquid,through which the generated cavitation bubbles can strip contaminants adhered to the pipe inner wall rapidly. The kinematics equation of the bubble inside the hydraulic oil is established and the numerical simulations are carried out. The influential factors such as gas pressure, excitation frequency,initial bubble radius and fluid viscosity are analyzed.The results show that the cavitation will evolve from steady state to transient state with the increasing gas pressure and initial bubble radius. The pulse generator frequency has a slightly effect on the growth of the bubble radius,and the breakup time of the bubble is shortened with the rising frequency. Similarly, the increasing viscosity of liquid has minimal impact on cavitation effect,which can weaken the growth and the collapse of the bubble. Moreover,the temperature inside the cavitation bubble is investigated,indicating that the instantaneous temperature inside the bubble increases with the rising gas pressure. Once the gas pressure is raised to a certain value greater than the fluid static pressure, the instantaneous temperature inside the bubble will rise sharply. So, it can be concluded that the gas-liquid coupling excitation-induced cavitation process is controllable, and some theoretical basis of the new excitation mode is presented,which is expected to be applied in the online cleaning of the complex hydraulic system. 展开更多
关键词 EXCITATION gas pulse cavitation bubble pulse generator COLLAPSE
下载PDF
Three-dimension micro magnetic detector based on GMI effect
11
作者 魏双成 邓甲昊 +1 位作者 韩超 杨雨迎 《Journal of Beijing Institute of Technology》 EI CAS 2014年第2期143-146,共4页
The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to pro... The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction. 展开更多
关键词 giant magneto-impedance(GMI)effect amorphous wire three dimension detector pulse generator analog switch
下载PDF
Pulse Generation and Compression Techniques for Microwave Electronics and Ultrafast Systems
12
作者 Ke Wu MuhibUr Rahman 《Electromagnetic Science》 2023年第1期18-41,共24页
Ultrabroadband systems and ultrafast electronics require the generation,transmission,and processing of high-quality ultrashort pulses rang-ing from nanoseconds(ns)to picoseconds(ps),which include well-established and ... Ultrabroadband systems and ultrafast electronics require the generation,transmission,and processing of high-quality ultrashort pulses rang-ing from nanoseconds(ns)to picoseconds(ps),which include well-established and emerging applications of time-domain reflectometry,arbitrary wave-form generation,sampling oscilloscopes,frequency synthesis,through-wall radar imaging,indoor communication,radar surveillance,and medical radar detection.Impulse radar advancements in industrial,scientific,and medical(ISM)domains are,for example,driven by ns-scale-defined ultrawideband(UWB)technologies.Nevertheless,the generation of ultrashort ps-scale pulses is highly desired to achieve unprecedented performances in all these ap-plications and future systems.However,due to the variety and applicability of different pulse generation and compression techniques,the selection of optimum or appropriate pulse generators and compressors is difficult for practitioners and users.To this end,this article aims to provide a comprehen-sive overview of ultrashort ns and ps pulse generation and compression techniques.The proposed and developed pulse generators available in the litera-ture and on the market,which are characterized by their corresponding pros and cons,are also explored.The theoretical analysis of pulse generation us-ing a nonlinear transmission line(NLTL)presented in the literature is briefly explained as well.Additionally,a holistic overview of these pulse genera-tors from the perspective of applications is given to describe their utilization in practical systems.All of these techniques are well summarized and com-pared in terms of fundamental pulse parameters,and research gaps in specified areas are highlighted.A thorough discussion of previous research work on various topologies and techniques is presented,and potential future directions for technical advancement are examined. 展开更多
关键词 Picosecond(ps)pulse generator Ultrafast electronics Ultrawideband(UWB)communication pulse generation Monocycle pulse shape Gaussian pulse shape UWB pulse generator pulse reconfigurability Nonlinear transmission line(NLTL) pulse shape modulation Wireless vital sign monitoring Breast cancer detection.
原文传递
Millimeter-wave modulated optical pulse generated by pulse repetition rate multiplication and temporal Talbot effect 被引量:5
13
作者 潘政清 叶青 +2 位作者 蔡海文 瞿荣辉 方祖捷 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第9期634-637,共4页
A novel scheme was proposed to generate a millimeter-wave (MMW) optical pulse by combining pulse repetition rate multiplication (PRRM) technology and temporal Talbot effect (TTE). A cascaded Mach- Zehnder interf... A novel scheme was proposed to generate a millimeter-wave (MMW) optical pulse by combining pulse repetition rate multiplication (PRRM) technology and temporal Talbot effect (TTE). A cascaded Mach- Zehnder interferometer (MZI) lattice was used for PRRM, and a linearly chirped fiber grating (LCFG) was used as TTE. The basic principle was analyzed by using a Gaussian input short pulse and its characteristics were discussed by numerical simulation. It is shown that the proposed scheme is feasible for MMW signal generation and has potential merits for practical application of radio over fiber (ROF) technology. 展开更多
关键词 Computer simulation Electromagnetic waves Integrated optoelectronics Light pulse generators Millimeter waves PHOTOMULTIPLIERS Signal generators
原文传递
Optical ultra-wideband pulse generation and distribution using a dual-electrode Mach-Zehnder modulator 被引量:5
14
作者 李晶 宁提纲 +1 位作者 裴丽 祁春慧 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第2期138-141,共4页
A novel approach to generate and distribute ultra-wideband (UWB) pulses in optical domain is investigated. In this proposed scheme, a dual-electrode Mach-Zehnder modulator (DE-MZM) is biased at its quadrature poin... A novel approach to generate and distribute ultra-wideband (UWB) pulses in optical domain is investigated. In this proposed scheme, a dual-electrode Mach-Zehnder modulator (DE-MZM) is biased at its quadrature point so as to realize the linear response. Then the intensity of output optical field can be assumed to the subtraction of two input Gaussian pulses. If the input Gaussian pulses are with the same sharp parameters but different time delays, a quasi-monocycle-waveform UWB signal can be generated. If the input Gaussian pulses are with different amplitudes and full-width at half-maximum (FWHM), a quasi-doublet-waveform UWB signal can be generated. A transmission of the UWB signals through a 25-km single mode fiber is carried out successfully. The results in both temporal and frequency domains are also presented. 展开更多
关键词 Light modulators? ?Modulation? ?pulse generators? ?Single mode fibers
原文传递
Multi-wavelength pulse generation using flattop optical frequency comb and arrayed waveguide grating 被引量:2
15
作者 窦玉杰 张洪明 姚敏玉 《Chinese Optics Letters》 SCIE EI CAS CSCD 2012年第12期82-83,共2页
A scheme of multi-wavelength pulse generator using optical frequency comb and arrayed waveguide grating (AWG) is proposed and experimentally demonstrated. A flattop optical frequency comb is shaped into multiple nar... A scheme of multi-wavelength pulse generator using optical frequency comb and arrayed waveguide grating (AWG) is proposed and experimentally demonstrated. A flattop optical frequency comb is shaped into multiple narrowband Gaussian spectra by using an AWG which contains a number of Gaussian channels, and then multi-wavelength optical pulses are achieved. In the experiment, six wavelength pulses with full width at half-maximum (FWHM) of 14.6 ps at I0 GHz are obtained, and two wavelength-interleaved pulse trains at 20 GHz and four wavelength-interleaved multi-wavelength optical pulses. This scheme has and time-interval can be readily controlled. pulse trains at 40 GHz are demonstrated by using the flexibility because the pulse width, the repetition rate, 展开更多
关键词 Natural frequencies Optical materials pulse generators TELECOMMUNICATION WAVELENGTH
原文传递
Repetition rate tunable ultra-short optical pulse generation based on electrical pattern generator 被引量:1
16
作者 傅鑫 张洪明 +1 位作者 燕萌 姚敏玉 《Chinese Optics Letters》 SCIE EI CAS CSCD 2009年第11期1010-1011,共2页
An actively mode-locked laser with tunable repetition rate is proposed and experimentally demonstrated based on a programmable electrical pattern generator. By changing the repetition rate of the electrical patterns a... An actively mode-locked laser with tunable repetition rate is proposed and experimentally demonstrated based on a programmable electrical pattern generator. By changing the repetition rate of the electrical patterns applied on the in-cavity modulator, the repetition rate of the output optical pulse sequences changes accordingly while the pulse width of the optical pulse train remains almost constant. In other words, the output ultra-short pulse train has a tunable duty cycle. In a proof-of-principle experiment, optical pulses with repetition rates of 10, 5, 2.5 and 1.25 GHz are obtained by adjusting the electrical pattern applied on the in-cavity modulator while their pulse widths remain almost unchanged. 展开更多
关键词 Electric generators Laser pulses LASERS Light modulators Light pulse generators MODULATION Q switched lasers
原文传递
Millijoule pulse energy picosecond fiber chirped-pulse amplification system 被引量:1
17
作者 杨直 胡晓鸿 +2 位作者 王屹山 张伟 赵卫 《Chinese Optics Letters》 SCIE EI CAS CSCD 2011年第4期42-45,共4页
The efficient generation of a 1.17-mJ laser pulse with 360 ps duration using an ytterbium (Yb)-doped fiber amplifier chain seeded by a homemade mode-locked fiber laser is demonstrated experimentally. A specially des... The efficient generation of a 1.17-mJ laser pulse with 360 ps duration using an ytterbium (Yb)-doped fiber amplifier chain seeded by a homemade mode-locked fiber laser is demonstrated experimentally. A specially designed figure-of-eight fiber laser acts as the seed source of a chirped-pulse amplification (CPA) system and generates mode-locked pulses with hundreds of picosecond widths. Two kinds of large-mode-area (LMA) double-clad Yb-doped fibers are employed to construct the pre-amplifier and main amplifier. All of the adopted instruments help avoid severe nonlinearity in fibers to raise sub-nanosecond pulse energy with acceptable signal-to-noise ratio (SNR). The output spectrum of this fiber-based CPA system shows that amplified spontaneous emission (ASE) is suppressed to better than 30 dB, and the onset of stimulated Raman scattering is excluded. 展开更多
关键词 AMPLIFICATION Fiber amplifiers Fibers pulse amplifiers pulse generators Signal to noise ratio YTTERBIUM
原文传递
Incoherent broadband optical pulse generation using an optical gate
18
作者 陈彪 江琼 《Chinese Optics Letters》 SCIE EI CAS CSCD 2008年第9期638-639,共2页
In two-dimensional (2D) time-spreading/wavelength-hopping optical code division multiple access (OCDMA) systems, employing less coherent broadband optical pulse sources allows lower electrical operating rate and b... In two-dimensional (2D) time-spreading/wavelength-hopping optical code division multiple access (OCDMA) systems, employing less coherent broadband optical pulse sources allows lower electrical operating rate and better system performance. An optical gate based scheme for generating weakly coherent (approximately incoherent) broadband optical pulses was proposed and experimentally demonstrated. In this scheme, the terahertz optical asymmetric demultiplexer, together with a coherent narrowband control pulse source, turns an incoherent broadband continuous-wave (CW) light source into the required pulse source. 展开更多
关键词 Code division multiple access Electromagnetic waves Gates (transistor) Laser pulses LIGHT Light pulse generators Light sources Lighting Telecommunication systems
原文传递
325 MHz and near transform-limited pulse output directly from an Er:fiber ring laser
19
作者 戚红霞 张健 +2 位作者 周耕稷 王爱民 张志刚 《Chinese Optics Letters》 SCIE EI CAS CSCD 2013年第6期43-45,共3页
A compact Er:fiber ring laser operated at a fundamental repetition rate of 325 MHz is reported. Two gain fibers with opposite dispersion are employed to shorten the fiber laser cavity for high repetition rate and sol... A compact Er:fiber ring laser operated at a fundamental repetition rate of 325 MHz is reported. Two gain fibers with opposite dispersion are employed to shorten the fiber laser cavity for high repetition rate and soliton-like pulse generation without losing gain and compactness. The spectral bandwidth of the output pulse is 24 nm and the direct pulse duration is 123 fs without extra-cavity compression, which are values near the transform-Hmited range. 展开更多
关键词 Bandwidth compression ERBIUM Fiber lasers pulse generators SOLITONS
原文传递
Generation of millimeter-wave sub-carrier optical pulse by using cascaded all-pass cavities
20
作者 徐钦峰 叶青 +3 位作者 潘政清 方祖捷 蔡海文 瞿荣辉 《Chinese Optics Letters》 SCIE EI CAS CSCD 2010年第1期7-10,共4页
A novel scheme is proposed to transform an ultra-short optical pulse to a millimeter-wave frequencymodulated pulse by using the cascaded all-pass cavities (APCs). The envelope waveform of the generated pulse train i... A novel scheme is proposed to transform an ultra-short optical pulse to a millimeter-wave frequencymodulated pulse by using the cascaded all-pass cavities (APCs). The envelope waveform of the generated pulse train is calculated, showing effective improvement by APC cascading. The extinction ratio is analyzed with different input pulses, different cavity reflectivities, and different cascading numbers. It is shown that the cascading does not introduce much effect on the extinction ratio. Two designs by using Gires-Tournois cavity and waveguide ring resonators are proposed to realize the cascaded APC. 展开更多
关键词 Chemical plants Laser pulses Light extinction Light pulse generators Millimeter wave devices
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部