期刊文献+
共找到324篇文章
< 1 2 17 >
每页显示 20 50 100
Scanning Electron Microscopy of Antennae of Aphidoletes aphidimyza (Diptera: Cecidomyiidae) 被引量:6
1
作者 张洁 杨茂发 《Zoological Research》 CAS CSCD 北大核心 2008年第1期108-112,共5页
The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the ... The morphology of antennae of Aphidoletes aphidimyza was observed with a scanning electron microscope. The results showed that both male and female were fourteen segmented, the male was approximately 2000 μm and the female was 1050μm. Six types of sensillae on the antenna were observed, viz. chaetica (Ch), trichoidea (Tr), basiconica (Ba), cavity (Ca), styloid (St) and circumfila (Ci) on the antennae of A. aphidimyza. Sensillae Ch had a long external-process, with a base surrounded by membranous sockets and a length of about 67.5 μm. Sensillae Tr were distally curved and inserted into a depression, 61.0μm long. Sensillae Ba were peg-like and 4.7μm long on the antennae. Sensillae Ca were pit-like in appearance and the diameter of the pit was 1.2μm. Sensilla St was found on the second sub-segment flagellum of the male antennae. The length of the sensilla was about 21 μm and the diameter was 1.5μm. The circurnfila, which are a unique type of sensilla found only on cecidomyiid antennae, formed loops around each of the antennal sub-segments, and were attached to the surface by a series of stalks. Sensilla St was only present on male antenna. The number of Ba and Tr was almost the same in both sexes. There were more Sensilla Ca on the male antenna than on the female, while there was more Ch on the female. 展开更多
关键词 Aphidoletes aphidimyza scanning electron microscopy ANTENNA Sensillae ULTRASTRUCTURE
下载PDF
Bacterial entombment by intratubular mineralization following orthograde mineral trioxide aggregate obturation: a scanning electron microscopy study 被引量:5
2
作者 Jun Sang Yoo Seok-Woo Chang +8 位作者 So Ram Oh Hiran Perinpanayagam Sang-Min Lim Yeon-Jee Yoo Yeo-Rok Oh Sang-Bin Woo Seung-Hyun Han Qiang Zhu Kee-Yeon Kum 《International Journal of Oral Science》 SCIE CAS CSCD 2014年第4期227-232,共6页
The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted huma... The time domain entombment of bacteria by intratubular mineralization following orthograde canal obturation with mineral trioxide aggregate(MTA) was studied by scanning electron microscopy(SEM). Single-rooted human premolars(n560) were instrumented to an apical size #50/0.06 using ProF ile and treated as follows: Group 1(n510) was filled with phosphate buffered saline(PBS); Group 2(n510) was incubated with Enterococcus faecalis for 3 weeks, and then filled with PBS; Group 3(n520) was obturated orthograde with a paste of OrthoM TA(BioM TA, Seoul, Korea) and PBS; and Group 4(n520) was incubated with E. faecalis for 3 weeks and then obturated with OrthoM TA–PBS paste. Following their treatments, the coronal openings were sealed with PBS-soaked cotton and intermediate restorative material(IRM), and the roots were then stored in PBS for 1, 2, 4, 8 or 16 weeks. After each incubation period, the roots were split and their dentin/MTA interfaces examined in both longitudinal and horizontal directions by SEM. There appeared to be an increase in intratubular mineralization over time in the OrthoM TA-filled roots(Groups 3 and 4). Furthermore, there was a gradual entombment of bacteria within the dentinal tubules in the E. faecalis inoculated MTA-filled roots(Group 4). Therefore, the orthograde obturation of root canals with OrthoM TA mixed with PBS may create a favorable environment for bacterial entombment by intratubular mineralization. 展开更多
关键词 bacterial entombment intratubular mineralization orthograde canal obturation scanning electron microscopy tag-like structure
下载PDF
Comparison of scanning electron microscopy findings regarding biofilm colonization with microbiological results in nasolacrimal stents for external, endoscopic and transcanalicular dacryocystorhinostomy 被引量:1
3
作者 Melike Balikoglu-Yilmaz Tolga Yilmaz +4 位作者 Sule Cetinel Umit Taskin Ayse Banu Esen Muhittin Taskapili Timur Kose 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第3期534-540,共7页
AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidi... AIM:To compare bacterial biofilm colonization in lacrimal stents following external dacryocystorhinostomy(EX-DCR),endoscopic dacryocystorhinostomy(EN-DCR),and transcanalicular dacryocystorhinostomy(TC-DCR)with multidiode laser.METHODS:This prospective study included 30consecutive patients with nasolacrimal duct obstruction who underwent EXT-,EN-,or TC-DCR.Thirty removed lacrimal stent fragments and conjunctival samples were cultured.The lacrimal stent biofilms were examined by scanning electron microscopy(SEM).RESULTS:Eleven(36.7%)of the 30 lacrimal stent cultures were positive for aerobic bacteria(most commonly Staphylococcus epidermidis and Pseudomonas aeruginosa).However anaerobic bacteria and fungi were not identified in the lacrimal stent cultures.Twenty-seven(90%)patients had biofilmpositive lacrimal stents.The conjunctival culture positivity after the DCR,biofilm positivity on stents,the grade of biofilm colonization,and the presence of mucus and coccoid and rod-shaped organisms did not significantly differ between any of the groups(P】0.05).However,a significant difference was found when the SEM results were compared to the results of the lacrimal stent and conjunctival cultures(P【0.001).CONCLUSION:Type of dacryocystorhinostomy(DCR)surgery did not affect the biofilm colonization of the lacrimal stents.SEM also appears to be more precise than microbiological culture for evaluating the presence of biofilms on lacrimal stents. 展开更多
关键词 biofilms nasolacrimal duct obstruction EPIPHORA DACRYOCYSTITIS scanning electron microscopy
下载PDF
Scanning electron microscopy coupled with energydispersive X-ray spectrometry for quick detection of sulfuroxidizing bacteria in environmental water samples 被引量:1
4
作者 SUN Chengjun JIANG Fenghua +5 位作者 GAO Wei LI Xiaoyun YU Yanzhen YIN Xiaofei WANG Yong DING Haibing 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2017年第1期185-191,共7页
Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not mee... Detection of sulfur-oxidizing bacteria has largely been dependent on targeted gene sequencing technology or traditional cell cultivation, which usually takes from days to months to carry out. This clearly does not meet the requirements of analysis for time-sensitive samples and/or complicated environmental samples. Since energy-dispersive X-ray spectrometry(EDS) can be used to simultaneously detect multiple elements in a sample, including sulfur, with minimal sample treatment, this technology was applied to detect sulfur-oxidizing bacteria using their high sulfur content within the cell. This article describes the application of scanning electron microscopy imaging coupled with EDS mapping for quick detection of sulfur oxidizers in contaminated environmental water samples, with minimal sample handling. Scanning electron microscopy imaging revealed the existence of dense granules within the bacterial cells, while EDS identified large amounts of sulfur within them. EDS mapping localized the sulfur to these granules. Subsequent 16S rRNA gene sequencing showed that the bacteria detected in our samples belonged to the genus Chromatium, which are sulfur oxidizers. Thus, EDS mapping made it possible to identify sulfur oxidizers in environmental samples based on localized sulfur within their cells, within a short time(within 24 h of sampling). This technique has wide ranging applications for detection of sulfur bacteria in environmental water samples. 展开更多
关键词 sulfur bacteria energy-dispersive X-ray spectrometry scanning electron microscopy bacteria detection environmental water samples 16S rRNA sequencing
下载PDF
Study of a Novel Small Caliber Vascular Graft in a Canine Model with Optical and Scanning Electron Microscopy 被引量:1
5
作者 XU Yi-min QI Song-tao SHI Xiao-feng ZENG Shao-wen LI Wei-qiu HUANG Guang-long ZHUANG Bing-rong 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第1期22-32,共11页
A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography w... A novel biological small-diameter vascular graft was evaluated in a canine model. 3 cm long segments with 4 mm I.D. were implanted end-to-end in the carotid position of 12 dogs for 6 months. Color Doppler sonography was performed at the first week post-operation, and angiography was then administered to 9 grafts at 4th week, 12th week and 24th week respectively to monitor the graft pantency and blood flow characteristics. Vascular samples containing the grafts were collected at 1st week, 8th week, 12th week and 24th week after implantation. Morphological changes of the grafts were observed by optical and scanning electron microscopic (SEM) studies and compared with that of the original prosthesis and the normal host vessel. All grafts were patent throughout the experiment except one graft. Histopathology and SEM demonstrated both a nearly complete inner capsule of varied thickness lining the graft luminal surface and connective tissue adventitia formation at one-week post-operation. The neointima became confluent at 8 weeks and then compact but had no signs of hyperplasia up to 12 weeks; meanwhile on the neointimal surface newly grown endothelial-like cells were migrating from the stoma to the middle portion. The grafts also illustrated endothelialization in many “islands” in the mid-segment luminal surface of the grafts. In addition, the closer distance the cells towards the stoma were, the more morphological similarity the cells with the normal endothelial were. Taken together, the biological vascular graft remained patent for 24 weeks as a carotid prosthesis, characterized by the early and complete neointima formation plus endothelialization starting before 12 weeks post grafting. Therefore, the graft seems suitable for reconstruction of vascular lesions in dogs. Further studies may be carried out to extend the graft application for the clinical use. 展开更多
关键词 DOG Surgical implantation Common carotid artery Biological vascular graft RECONSTRUCTION HISTOPATHOLOGY scanning electron microscopy ENDOTHELIALIZATION
下载PDF
Scanning Electron Microscopy(SEM) Observations of Antennal Sensilla of Chrysopa pallens Rambur(Neuroptera:Chrysopidae)
6
作者 Wang Juan Chen Hongyin +3 位作者 Wang Mengqing Liu Chenxi Zhang Haiping Zhang Lisheng 《Plant Diseases and Pests》 CAS 2017年第2期1-4,19,共5页
[Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The ... [Objectives]The paper was to provide background information for ongoing research on relationship between smell and behavior of the green lacewing Chrysopa pallens( Rambur)( Neuroptera: Chrysopidae). [Methods]The submicroscopic structure of antennal sensilla of C. pallens was examined using scanning electron microscopy. [Results]Antennae of female and male C. pallens were linear in shape and( 1. 52 ± 0. 08) and( 1. 58 ± 0. 23) cm in length,respectively. The scape and pedicel were composed of single sub-segment,while the flagellum consisted of 116 sub-segments,on which most sensilla distributed. The flagella of female and male antennae were( 1. 44 ± 0. 04) and( 1. 47 ± 0. 13) cm in length,respectively. Nine morphological sensilla types were recorded in both sexes,including four types of highly abundant and widely distributed sensilla trichodea( ST Ⅰ,ST Ⅱ,ST Ⅲ and ST Ⅳ),three types of sensilla basiconica( SB Ⅰ,SB Ⅱ,and SB Ⅲ),and one of each type of sensilla chaetica and B9 hm bristles. Although the shape,structure,numbers,and distribution of antennae of females and males were basically similar,major differences were recorded between the sexes in the length of some sensilla types. Both the ST Ⅲ and SB Ⅰ in female adults were significantly longer than that in male ones. Notably,SB Ⅱ was found only in female. [Conclusions]The paper laid a foundation for revealing the relationship between smell and behavior,playing a crucial role in promoting the important biological control effect of C. pallens in farmland ecological system. 展开更多
关键词 Chrysopa pallens ANTENNA SENSILLA ULTRASTRUCTURE scanning electron microscopy
下载PDF
Detecting Magma Mixing Processes Using Scanning Electron Microscopy Method
7
作者 Nicola Mari 《Journal of Earth Science and Engineering》 2016年第2期90-97,共8页
This review work explains some of the most important techniques to detect the occurrence of magma mixing phenomena in the volcanic rocks by using SEM (scanning electron microscope). In particular, the most useful me... This review work explains some of the most important techniques to detect the occurrence of magma mixing phenomena in the volcanic rocks by using SEM (scanning electron microscope). In particular, the most useful methods related to the different types of mixing are reviewed: complete mixing (blending) or incomplete mixing (mingling). For blending, backscattered electron images and EDS (energy dispersive spectroscopy) are the most accurate methods: an example taken from a sample of ash of the 2007 Stromboli volcano eruption was used. For mingling, the best method is given by X-ray elemental mapping (in particular of Ca and Si), as explained through the example taken from a sample of the 2003 explosive eruption of Soufriere Hills volcano. The aim of this work was to establish whereas would be useful to use backscattered eletron images, EDS, or X-ray elemental mapping techniques, according to the different types of mixing that occur very often in magmatic systems. 展开更多
关键词 scanning electron microscopy VOLCANOLOGY magma mixing GEOCHEMISTRY MINERALOGY disequilibrium textures.
下载PDF
Assessing the Impact of Aggregate Type on Air Lime Mortar Properties Using Scanning Electron Microscopy
8
作者 Sarah Scannell Mike Lawrence and Pete Walker 《Journal of Civil Engineering and Architecture》 2016年第2期139-147,共9页
In recent years, the need for low energy materials has become increasingly important. With government targets aiming to reduce carbon emissions by 80% by 2050, and the construction industry being responsible for 50% o... In recent years, the need for low energy materials has become increasingly important. With government targets aiming to reduce carbon emissions by 80% by 2050, and the construction industry being responsible for 50% of the UK's carbon emissions, it is of vital importance that positive changes are made. One of these changes is to reduce the carbon footprint of the materials used in construction. Lime mortar has been used for centuries, but since the arrival of cement, its use in modern construction has diminished, in part due to having lower compressive strengths than cement mortar. Air lime mortar, in particular, can be categorised as low energy due to the reabsorption of a significant amount of COE during the setting process: carbonation. The current study focuses on the impact of different types of aggregate (limestone and silicate) on air lime mortar strength. Previous research has found that higher strengths can be achieved with the use of limestone aggregate, but little is known about the reasons why. The research presented here looks at a microstructural analysis through use of SEM (scanning electron microscopy) in order to determine reasons behind the strength differences. At early stages of curing, there are clear differences at the interface of binder and aggregate. 展开更多
关键词 Air lime LIMESTONE silicate aggregate scanning electron microscopy carbonation.
下载PDF
Nucleation and Growth of Thallium on Thin Film Mercury Electrode: Voltammetric, Scanning Electron Microscopy, Chronoamperometric and Electrochemical Impedance Studies
9
作者 Abdoulkadri Ayouba Mahamane Boubié Guel Paul-Louis Fabre 《American Journal of Analytical Chemistry》 CAS 2022年第11期415-430,共16页
Thallium is a heavy metal highly toxic to the biosphere. It can be determined by anodic stripping voltammetry after deposition on mercury film. The aim of this work is to study the conditions and mechanisms of deposit... Thallium is a heavy metal highly toxic to the biosphere. It can be determined by anodic stripping voltammetry after deposition on mercury film. The aim of this work is to study the conditions and mechanisms of deposition of Hg on glassy carbon electrode and Tl on Hg film by cyclic voltammetry, scanning electron microscopy, chronoamperometry and impedance techniques. The results showed a germination and growth of a 3D Hg phase on glassy carbon electrode. Similarly, the electrodeposition of Tl on Hg follows a 3D three-dimensional nucleation with diffusion controlled growth. The impedance measurements reveal an easier charge transfer on the Tl film. 展开更多
关键词 THALLIUM Mercury Film Cyclic Voltammetry scanning electron microscopy Impedance Measurements
下载PDF
Scanning Electron Microscopy (SEM) of the Bug Eye and Sand Coral
10
作者 Sayid Ali Sayid Aliyu Dadan-Garba +1 位作者 Daniel Elaigwu Enenche Barnabas Achakpa Ikyo 《Microscopy Research》 2020年第1期1-7,共7页
We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially... We present a Scanning Electron Microscopy (SEM) technique for the characterisation of biological and non-biological samples at nano-scale level. Scanning Electron Microscopy has been around for a long while especially in material science laboratories in developed countries. The SEM has enabled scientist to have a better understanding of microstructure by providing unsurpassed optical magnifications of samples. In this introductory paper, we introduce the techniques of using SEM to capture highly magnified microstructure of a fly found on an African soybean (Glycine max) seed. We are able to estimate the number of lenses in each eye and zoom into features that could describe its life characteristics. Hexagonal lenses are estimated to have sizes ranging from 14 um to 19 um. This paper also presents a finding of a sea coral “pie like structure” on a single grain of sand used for water filtration. 展开更多
关键词 Bug Eye Sand Coral scanning electron microscopy
下载PDF
MORPHOLOGICAL CHANGES OF RATS MUSCLES AT VARIOUS POSTMORTEM INTERVALS BY SCANNING ELECTRON MICROSCOPY
11
作者 廖志钢 易旭夫 +1 位作者 肖飞 彭雪梅 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第4期255-258,共4页
The aim of this study was to observe the morphological changes of muscle in the process of rigor mortis. The quadriceps of 40 rats at various postmortem intervals were observed under the... The aim of this study was to observe the morphological changes of muscle in the process of rigor mortis. The quadriceps of 40 rats at various postmortem intervals were observed under the scanning electron microscope(SEM) and the light microscope by phosphotungstic acid haematoxylin(PTAH) stain. The results showed that the striations of muscle were blurred within 4 h, but they became apparent from 6 h to 24 h after death. The authors suggest that this phenomenon be associated with the increased resistance of muscle against the postmortal changes. The observations by scanning electron microscopy and light microscopy have revealed that the muscles do contract in the process of rigor mortis because the distance between two Z lines shortens and the I band narrows, compared with those in anaesthetised animals. The basic biochemical process for the formation of rigor mortis is the same as that of muscle contraction except that the former happens postmortem and the latter antemortem. 展开更多
关键词 rigor mortis muscle contraction scanning electron microscopy
下载PDF
Applications of scanning electron microscopy in earth sciences 被引量:7
12
作者 CHEN Li XU Jun CHEN Jing 《Science China Earth Sciences》 SCIE EI CAS CSCD 2015年第10期1768-1778,共11页
This paper expounds upon the basic principle of scanning electron microscopy(SEM),the main features of image types,and different signals,and the applications and prospects in earth sciences research are reviewed.High-... This paper expounds upon the basic principle of scanning electron microscopy(SEM),the main features of image types,and different signals,and the applications and prospects in earth sciences research are reviewed.High-resolution field emission SEM allows observation and investigation of a very fine micro area in situ.Using low-vacuum mode SEM,geological insulating samples can be analyzed directly without coating,demonstrating the wide application prospect.Combined with backscatter detector(BSE),energy dispersal X-ray spectroscopy(EDS),cathodoluminescence spectrometry(CL),and electron back-scattering diffraction(EBSD),SEM can yield multiple types of information about geological samples at the same time,such as superficial microstructure,CL analysis,BSE image,component analysis,and crystal structure features.In this paper,we use examples to discuss the geological application of SEM.We stress that we should not only focus on the CL image analysis,but strengthen CL spectrum analyses of minerals.These results will effectively reveal the mineral crystal lattice defects and trace element composition and can help to reconstruct mineral growth conditions precisely. 展开更多
关键词 scanning electron microscopy signal detector MINERALS
原文传递
Imaging Electronic Structure of Carbon Nanotubes by Voltage-Contrast Scanning Electron Microscopy 被引量:2
13
作者 Aravind Vijayaraghavan Sabine Blatt +4 位作者 Christoph Marquardt Simone Dehm Raghav Wahi Frank Hennrich Ralph Krupke 《Nano Research》 SCIE EI CSCD 2008年第4期321-332,共12页
We introduce voltage-contrast scanning electron microscopy(VC-SEM)for visual characterization of the electronic properties of single-walled carbon nanotubes.VC-SEM involves tuning the electronic band structure and ima... We introduce voltage-contrast scanning electron microscopy(VC-SEM)for visual characterization of the electronic properties of single-walled carbon nanotubes.VC-SEM involves tuning the electronic band structure and imaging the potential profi le along the length of the nanotube.The resultant secondary electron contrast allows to distinguish between metallic and semiconducting carbon nanotubes and to follow the switching of semiconducting nanotube devices,as confi rmed by in situ electrical transport measurements.We demonstrate that high-density arrays of individual nanotube devices can be rapidly and simultaneously characterized.A leakage current model in combination with fi nite element simulations of the device electrostatics is presented in order to explain the observed contrast evolution of the nanotube and surface electrodes.This work serves to fi ll a void in electronic characterization of molecular device architectures. 展开更多
关键词 Carbon nanotubes electronic properties voltage-contrast scanning electron microscopy ELECTROSTATICS
原文传递
Slice Thickness Optimization for the Focused Ion Beam-Scanning Electron Microscopy 3D Tomography of Hierarchical Nanoporous Gold 被引量:2
14
作者 Alexander Shkurmanov Tobias Krekeler Martin Ritter 《Nanomanufacturing and Metrology》 EI 2022年第2期112-118,共7页
The combination of focused ion beam (FIB) with scanning electron microscopy (SEM), also known as FIB-SEM tomography, has become a powerful 3D imaging technique at the nanometer scale. This method uses an ion beam to m... The combination of focused ion beam (FIB) with scanning electron microscopy (SEM), also known as FIB-SEM tomography, has become a powerful 3D imaging technique at the nanometer scale. This method uses an ion beam to mill away a thin slice of material, which is then block-face imaged using an electron beam. With consecutive slicing along the z-axis and subsequent imaging, a volume of interest can be reconstructed from the images and further analyzed. Hierarchical nanoporous gold (HNPG) exhibits unique structural properties and has a ligament size of 15–110 nm and pore size of 5–20 nm. Accurate reconstruction of its image is crucial in determining its mechanical and other properties. Slice thickness is one of the most critical and uncertain parameters in FIB-SEM tomography. For HNPG, the slice thickness should be at least half as thin as the pore size and, in our approach, should not exceed 10 nm. Variations in slice thickness are caused by various microscope and sample parameters, e.g., converged ion milling beam shape, charging effects, beam drift, or sample surface roughness. Determining and optimizing the actual slice thickness variation appear challenging. In this work, we examine the influence of ion beam scan resolution and the dwell time on the mean and standard deviation of slice thickness. After optimizing the resolution and dwell time to achieve the target slice thickness and lowest possible standard deviation, we apply these parameters to analyze an actual HNPG sample. Our approach can determine the thickness of each slice along the z-axis and estimate the deviation of the milling process along the y-axis (slow imaging axis). For this function, we create a multi-ruler structure integrated with the HNPG sample. 展开更多
关键词 Focused ion beam scanning electron microscopy TOMOGRAPHY Hierarchical nanoporous gold
原文传递
A different approach for determining the responsivity of n^+p detectors using scanning electron microscopy
15
作者 Omeime Xerviar Esebamen Gran Thungstrm Hans-Erik Nilsson 《Journal of Semiconductors》 EI CAS CSCD 2012年第7期29-33,共5页
This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the res... This paper explores an alternative to the standard method of studying the responsivities (the input-output gain) and other behaviours of detectors at low electron energy. The research does not aim to compare the results of differently doped n+p detectors; its purpose is to provide an alternative characterization method (using scanning electron microscopy) to those used in previous studies on the responsivity ofn+p doped detectors as a function of the electron radiation energy and other interface oarameters. 展开更多
关键词 scanning electron microscopy RESPONSIVITY n+p detector
原文传递
Scanning transmission electron microscopy: A review of high angle annular dark field and annular bright field imaging and applications in lithium-ion batteries 被引量:2
16
作者 Yu-Xin Tong Qing-Hua Zhang Lin Gu 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期23-34,共12页
Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. H... Scanning transmission electron microscopy(STEM) has been shown as powerful tools for material characterization,especially after the appearance of aberration-corrector which greatly enhances the resolution of STEM. High angle annular dark field(HAADF) and annular bright field(ABF) imaging of the aberration-corrected STEM are widely used due to their high-resolution capabilities and easily interpretable image contrasts. However, HAADF mode of the STEM is still limited in detecting light elements due to the weak electron-scattering power. ABF mode of the STEM could detect light and heavy elements simultaneously, providing unprecedented opportunities for probing unknown structures of materials. Atomiclevel structure investigation of materials has been achieved by means of these imaging modes, which is invaluable in many fields for either improving properties of materials or developing new materials. This paper aims to provide a introduction of HAADF and ABF imaging techniques and reviews their applications in characterization of cathode materials, study of electrochemical reaction mechanisms, and exploring the effective design of lithium-ion batteries(LIBs). The future prospects of the STEM are also discussed. 展开更多
关键词 scanning transmission electron microscopy high angle annular dark field annular bright field lithium-ion batteries
下载PDF
Nanoscale cathodoluminescence spectroscopy probing the nitride quantum wells in an electron microscope
17
作者 刘哲彤 刘秉尧 +8 位作者 梁冬冬 李晓梅 李晓敏 陈莉 朱瑞 徐军 魏同波 白雪冬 高鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期144-149,共6页
To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and ... To gain further understanding of the luminescence properties of multiquantum wells and the factors affecting them on a microscopic level,cathodoluminescence combined with scanning transmission electron microscopy and spectroscopy was used to measure the luminescence of In_(0.15)Ga_(0.85)N five-period multiquantum wells.The lattice-composition-energy relationship was established with the help of energy-dispersive x-ray spectroscopy,and the bandgaps of In_(0.15)Ga_(0.85)N and GaN in multiple quantum wells were extracted by electron energy loss spectroscopy to understand the features of cathodoluminescence spectra.The luminescence differences between different periods of multiquantum wells and the effects of defects such as composition fluctuation and dislocations on the luminescence of multiple quantum wells were revealed.Our study establishing the direct relationship between the atomic structure of In_(x)Ga_(1-x)N multiquantum wells and photoelectric properties provides useful information for nitride applications. 展开更多
关键词 nitride multiquantum wells defect CATHODOLUMINESCENCE scanning transmission electron microscopy
下载PDF
Scanning Electron Acoustic Microscopy of GaInAsSb by Metalorganic Chemical Vapor Deposition
18
作者 李树玮 金亿鑫 +3 位作者 周天明 张宝林 宁永强 蒋红 《Rare Metals》 SCIE EI CAS CSCD 1996年第2期101-105,共5页
Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and... Scanning electron acoustic microscopy (SEAM) is a new technique for imasing and characterization ofthermal, elastic and pyroelectric property variations on a microscale resolution. The signal generation mechanisms and the application of scanning electron acoustic microscopy in GalnAsSb alloy grown by MOCVD wereinvestigated. Defects below the surface of GalnAsSb alloy were found by SEAM images and cathodelumi-nescence. The results show that electronacoustic imaging has its own features over secondary electron imag-ing. 展开更多
关键词 scanning electron acoustic microscopy electron-acoustic imaging GAINASSB MOCVD
下载PDF
Characterization of a nano line width reference material based on metrological scanning electron microscope 被引量:2
19
作者 Fang Wang Yushu Shi +4 位作者 Wei Li Xiao Deng Xinbin Cheng Shu Zhang Xixi Yu 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第5期203-211,共9页
The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibra... The line width(often synonymously used for critical dimension,CD)is a crucial parameter in integrated circuits.To accurately control CD values in manufacturing,a reasonable CD reference material is required to calibrate the corresponding instruments.We develop a new reference material with nominal CDs of 160 nm,80 nm,and 40 nm.The line features are investigated based on the metrological scanning electron microscope which is developed by the National Institute of Metrology(NIM)in China.Also,we propose a new characterization method for the precise measurement of CD values.After filtering and leveling the intensity profiles,the line features are characterized by the combination model of the Gaussian and Lorentz functions.The left and right edges of CD are automatically extracted with the profile decomposition and k-means algorithm.Then the width of the two edges at the half intensity position is regarded as the standard CD value.Finally,the measurement results are evaluated in terms of the sample,instrument,algorithm,and repeatability.The experiments indicate efficiency of the proposed method which can be easily applied in practice to accurately characterize CDs. 展开更多
关键词 critical dimension line width metrological scanning electron microscopy TRACEABILITY
下载PDF
Recent progress on advanced transmission electron microscopy characterization for halide perovskite semiconductors 被引量:1
20
作者 Xiaomei Wu Xiaoxing Ke Manling Sui 《Journal of Semiconductors》 EI CAS CSCD 2022年第4期67-81,共15页
Halide perovskites are strategically important in the field of energy materials. Along with the rapid development of the materials and related devices, there is an urgent need to understand the structure–property rel... Halide perovskites are strategically important in the field of energy materials. Along with the rapid development of the materials and related devices, there is an urgent need to understand the structure–property relationship from nanoscale to atomic scale. Much effort has been made in the past few years to overcome the difficulty of imaging limited by electron dose,and to further extend the investigation towards operando conditions. This review is dedicated to recent studies of advanced transmission electron microscopy(TEM) characterizations for halide perovskites. The irradiation damage caused by the interaction of electron beams and perovskites under conventional imaging conditions are first summarized and discussed. Low-dose TEM is then discussed, including electron diffraction and emerging techniques for high-resolution TEM(HRTEM) imaging. Atomic-resolution imaging, defects identification and chemical mapping on halide perovskites are reviewed. Cryo-TEM for halide perovskites is discussed, since it can readily suppress irradiation damage and has been rapidly developed in the past few years. Finally, the applications of in-situ TEM in the degradation study of perovskites under environmental conditions such as heating,biasing, light illumination and humidity are reviewed. More applications of emerging TEM characterizations are foreseen in the coming future, unveiling the structural origin of halide perovskite’s unique properties and degradation mechanism under operando conditions, so to assist the design of a more efficient and robust energy material. 展开更多
关键词 organic–inorganic hybrid perovskite solar cell materials energy materials scanning electron microscopy transmission electron microscopy irradiation damage
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部