期刊文献+
共找到101,394篇文章
< 1 2 250 >
每页显示 20 50 100
The breaking of spin symmetry in the single-particle resonances in deformed nuclei
1
作者 Zhen-Yu Zheng Shou-Wan Chen Quan Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第3期237-245,共9页
The exploration of spin symmetry (SS) in nuclear physics has been instrumental in identifying atomic nucleus structures.In this study,we solve the Dirac equation from the relativistic mean field (RMF) in complex momen... The exploration of spin symmetry (SS) in nuclear physics has been instrumental in identifying atomic nucleus structures.In this study,we solve the Dirac equation from the relativistic mean field (RMF) in complex momentum representation.We investigated SS and its breaking in single-particle resonant states within deformed nuclei,with a focus on the illustrative nucleus168Er.This was the initial discovery of a resonant spin doublet in a deformed nucleus,with the expectation of the SS approaching the continuum threshold.With increasing single-particle energy,the splitting of the resonant spin doublets widened significantly.This escalating splitting implies diminishing adherence to the SS,indicating a departure from the expected behavior as the energy levels increase.We also analyzed the width of the resonant states,showing that lower orbital angular momentum resonances possess shorter decay times and that SS is preserved within broad resonant doublets,as opposed to narrow resonant doublets.Comparing the radial density of the upper components for the bound-state and resonant-state doublets,it becomes evident that while SS is well-preserved in the bound states,it deteriorates in the resonant states.The impact of nuclear deformation (β_(2)) on SS was examined,demonstrating that an increase in β_(2) resulted in higher energy and width splitting in the resonant spin doublets,which is attributed to increased component mixing.Furthermore,the sensitivity of spin doublets to various potential parameters such as surface diffuseness (a),radius (R),and depth (Σ0) is discussed,emphasizing the role of these parameters in SS.This study provides valuable insights into the behavior of spin doublets in deformed nuclei and their interplay with the nuclear structure,thereby advancing our understanding of SS in the resonance state. 展开更多
关键词 Spin symmetry resonant states Deformed nuclei Complex-momentum representation
下载PDF
Generation of lossy mode resonances(LMR)using perovskite nanofilms
2
作者 Dayron Armas Ignacio R.Matias +4 位作者 M.Carmen Lopez-Gonzalez Carlos Ruiz Zamarreño Pablo Zubiate Ignacio del Villar Beatriz Romero 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第2期33-40,共8页
The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin fi... The results presented here show for the first time the experimental demonstration of the fabrication of lossy mode resonance(LMR) devices based on perovskite coatings deposited on planar waveguides. Perovskite thin films have been obtained by means of the spin coating technique and their presence was confirmed by ellipsometry, scanning electron microscopy, and X-ray diffraction testing. The LMRs can be generated in a wide wavelength range and the experimental results agree with the theoretical simulations. Overall, this study highlights the potential of perovskite thin films for the development of novel LMR-based devices that can be used for environmental monitoring, industrial sensing, and gas detection, among other applications. 展开更多
关键词 PEROVSKITE thin films slab waveguide lossy mode resonance
下载PDF
Triple α-particle resonances in the decay of hot nuclear systems 被引量:1
3
作者 S. Zhang J. C. Wang +6 位作者 A. Bonasera M. R. Huang H. Zheng G. Q. Zhang Z. Kohley Y. G. Ma S. J. Yennello 《Chinese Physics C》 SCIE CAS CSCD 2019年第6期32-37,共6页
The Efimov(Thomas) trimers in excited 12 C nuclei, for which no observation exists yet, are discussed by means of analyzing the experimental data of 70(64)Zn(64 Ni)+ 70(64)Zn(64 Ni) reactions at the beam energy of E/A... The Efimov(Thomas) trimers in excited 12 C nuclei, for which no observation exists yet, are discussed by means of analyzing the experimental data of 70(64)Zn(64 Ni)+ 70(64)Zn(64 Ni) reactions at the beam energy of E/A = 35 MeV/nucleon. In heavy ion collisions, a-particles interact with each other and can form complex systems such as 8 Be and 12 C. For the 3 a-particle systems,multi-resonance processes give rise to excited levels of 12 C. The interaction between any two of the 3 a-particles provides events with one, two or three 8 Be. Their interfering levels are clearly seen in the minimum relative energy distributions. Events with the three a-particle relative energies consistent with the ground state of 8 Be are observed with the decrease of the instrumental error for the reconstructed 7.458 MeV excitation level in 12 C, which was suggested as the Efimov(Thomas) state. 展开更多
关键词 heavy ion REACTIONS Efimov state α-particle resonances relative KINETIC energy
原文传递
Searching for single-particle resonances with the Green’s function method 被引量:3
4
作者 Ya-Tian Wang Ting-Ting Sun 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2021年第5期24-32,共9页
Single-particle resonances in the continuum are crucial for studies of exotic nuclei.In this study,the Green’s function approach is employed to search for single-particle resonances based on the relativistic-mean-fie... Single-particle resonances in the continuum are crucial for studies of exotic nuclei.In this study,the Green’s function approach is employed to search for single-particle resonances based on the relativistic-mean-field model.Taking^(120)Sn as an example,we identify singleparticle resonances and determine the energies and widths directly by probing the extrema of the Green’s functions.In contrast to the results found by exploring for the extremum of the density of states proposed in our recent study[Chin.Phys.C,44:084105(2020)],which has proven to be very successful,the same resonances as well as very close energies and widths are obtained.By comparing the Green’s functions plotted in different coordinate space sizes,we also found that the results very slightly depend on the space size.These findings demonstrate that the approach by exploring for the extremum of the Green’s function is also very reliable and effective for identifying resonant states,regardless of whether they are wide or narrow. 展开更多
关键词 Single-particle resonances Extrema of Green’s functions Relativistic-mean-field theory
下载PDF
Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models 被引量:1
5
作者 Yan-Li Jiang Juan Li +6 位作者 Peng-Fei Zhang Feng-Xian Fan Jie Zou Pin Yang Peng-Fei Wang Shao-Yu Wang Jing Zhang 《World Journal of Gastroenterology》 SCIE CAS 2024年第9期1164-1176,共13页
BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diff... BACKGROUND Diffusion-weighted imaging(DWI)has been developed to stage liver fibrosis.However,its diagnostic performance is inconsistent among studies.Therefore,it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort.AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances.METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants.All participants underwent multi-b value DWI.The main DWI-derived parameters included Mono-apparent diffusion coefficient(ADC)from mono-exponential DWI,intravoxel incoherent motion model-derived true diffusion coefficient(IVIM-D),diffusion kurtosis imaging-derived apparent diffusivity(DKI-MD),stretched exponential model-derived distributed diffusion coefficient(SEM-DDC),fractional order calculus(FROC)model-derived diffusion coefficient(FROC-D)and FROC model-derived microstructural quantity(FROC-μ),and continuous-time random-walk(CTRW)model-derived anomalous diffusion coefficient(CTRW-D)and CTRW model-derived temporal diffusion heterogeneity index(CTRW-α).The correlations between DWI-derived parameters and fibrosis stages and the parameters’diagnostic efficacy in detecting significant fibrosis(SF)were assessed and compared.RESULTS CTRW-D(r=-0.356),CTRW-α(r=-0.297),DKI-MD(r=-0.297),FROC-D(r=-0.350),FROC-μ(r=-0.321),IVIM-D(r=-0.251),Mono-ADC(r=-0.362),and SEM-DDC(r=-0.263)were significantly correlated with fibrosis stages.The areas under the ROC curves(AUCs)of the combined index of the six models for distinguishing SF(0.697-0.747)were higher than each of the parameters alone(0.524-0.719).The DWI models’ability to detect SF was similar.The combined index of CTRW model parameters had the highest AUC(0.747).CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease.The combined index of CTRW parameters had the highest AUC. 展开更多
关键词 Liver fibrosis Magnetic resonance imaging Diffusion-weighted magnetic resonance Liver biopsy Significant fibrosis
下载PDF
Preoperative prediction of perineural invasion of rectal cancer based on a magnetic resonance imaging radiomics model:A dual-center study 被引量:2
6
作者 Yan Liu Bai-Jin-Tao Sun +3 位作者 Chuan Zhang Bing Li Xiao-Xuan Yu Yong Du 《World Journal of Gastroenterology》 SCIE CAS 2024年第16期2233-2248,共16页
BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for indivi... BACKGROUND Perineural invasion(PNI)has been used as an important pathological indicator and independent prognostic factor for patients with rectal cancer(RC).Preoperative prediction of PNI status is helpful for individualized treatment of RC.Recently,several radiomics studies have been used to predict the PNI status in RC,demonstrating a good predictive effect,but the results lacked generalizability.The preoperative prediction of PNI status is still challenging and needs further study.AIM To establish and validate an optimal radiomics model for predicting PNI status preoperatively in RC patients.METHODS This retrospective study enrolled 244 postoperative patients with pathologically confirmed RC from two independent centers.The patients underwent preoperative high-resolution magnetic resonance imaging(MRI)between May 2019 and August 2022.Quantitative radiomics features were extracted and selected from oblique axial T2-weighted imaging(T2WI)and contrast-enhanced T1WI(T1CE)sequences.The radiomics signatures were constructed using logistic regression analysis and the predictive potential of various sequences was compared(T2WI,T1CE and T2WI+T1CE fusion sequences).A clinical-radiomics(CR)model was established by combining the radiomics features and clinical risk factors.The internal and external validation groups were used to validate the proposed models.The area under the receiver operating characteristic curve(AUC),DeLong test,net reclassification improvement(NRI),integrated discrimination improvement(IDI),calibration curve,and decision curve analysis(DCA)were used to evaluate the model performance.RESULTS Among the radiomics models,the T2WI+T1CE fusion sequences model showed the best predictive performance,in the training and internal validation groups,the AUCs of the fusion sequence model were 0.839[95%confidence interval(CI):0.757-0.921]and 0.787(95%CI:0.650-0.923),which were higher than those of the T2WI and T1CE sequence models.The CR model constructed by combining clinical risk factors had the best predictive performance.In the training and internal and external validation groups,the AUCs of the CR model were 0.889(95%CI:0.824-0.954),0.889(95%CI:0.803-0.976)and 0.894(95%CI:0.814-0.974).Delong test,NRI,and IDI showed that the CR model had significant differences from other models(P<0.05).Calibration curves demonstrated good agreement,and DCA revealed significant benefits of the CR model.CONCLUSION The CR model based on preoperative MRI radiomics features and clinical risk factors can preoperatively predict the PNI status of RC noninvasively,which facilitates individualized treatment of RC patients. 展开更多
关键词 Rectal cancer Perineural invasion Magnetic resonance imaging Radiomics NOMOGRAM
下载PDF
The complex momentum representation approach and its application to low‑lying resonances in 17 O and^(29,31)F
7
作者 Si‑Zhe Xu Shi‑Sheng Zhang +1 位作者 Xiao‑Qian Jiang Michael Scott Smith 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第1期43-50,共8页
Approaches for predicting low-lying resonances,uniformly treating bound,and resonant levels have been a long-standing goal in nuclear theory.Accordingly,we explored the viability of the complex momentum representation... Approaches for predicting low-lying resonances,uniformly treating bound,and resonant levels have been a long-standing goal in nuclear theory.Accordingly,we explored the viability of the complex momentum representation(CMR)approach coupled with new potentials.We focus on predicting the energy of the low-lying 2p_(3∕2)resonance in 17 O,which is critical for s-process nucleosynthesis and missing in previous theoretical research.Using a Woods-Saxon potential based on the Koning-Delaroche optical model and constrained by the experimental one-neutron separation energy,we successfully predicted the resonant energy of this level for the first time.Our predictions of the bound levels and 1d_(3∕2)resonance agree well with the measurement results.Additionally,we utilize this approach to study the near-threshold resonances that play a role when forming a two-neutron halo in^(29,31)F.We found that the CMR-based predictions of the bound-level energies and unbound 1f7∕2 level agree well with the results obtained using the scattering phase shift method.Subsequently,we successfully found a solution for the 2p_(3∕2)resonance with energy just above the threshold,which is decisive for halo formation. 展开更多
关键词 Neutron capture Low-lying resonance Complex momentum representation resonance energy
下载PDF
Effects of electric field on vibrational resonances in Hindmarsh-Rose neuronal systems for signal detection
8
作者 李晓霞 薛小鹏 +3 位作者 刘栋杰 余天意 何倩倩 徐桂芝 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期730-741,共12页
Changes in the concentration of charged ions in neurons can generate induced electric fields,which can further modulate cell membrane potential.In this paper,Fourier coefficients are used to investigate the effect of ... Changes in the concentration of charged ions in neurons can generate induced electric fields,which can further modulate cell membrane potential.In this paper,Fourier coefficients are used to investigate the effect of electric field on vibrational resonance for signal detection in a single neuron model and a bidirectionally coupled neuron model,respectively.The study found that the internal electric field weakens vibrational resonance by changing two factors,membrane potential and phase-locked mode,while the periodic external electric field of an appropriate frequency significantly enhances the vibrational resonance,suggesting that the external electric field may play a constructive role in the detection of weak signals in the brain and neuronal systems.Furthermore,when the coupling of two neurons is considered,the effect of the electric field on the vibrational resonance is similar to that of a single neuron.The paper also illustrates the effect of electric field coupling on vibrational resonance.This study may provide a new theoretical basis for understanding information encoding and transmission in neurons. 展开更多
关键词 electric field Fourier-coefficient neuronal dynamics vibrational resonance
下载PDF
Magnetic resonance imaging of extraocular rectus muscles abnormalities in acute acquired concomitant esotropia 被引量:1
9
作者 Jia-Yu Chen Li-Rong Zhang +5 位作者 Jia-Wen Liu Jie Hao Hui-Xin Li Qiong-Yue Zhang Zhao-Hui Liu Jing Fu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期119-125,共7页
AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-con... AIM:To investigate the difference of medial rectus(MR)and lateral rectus(LR)between acute acquired concomitant esotropia(AACE)and the healthy controls(HCs)detected by magnetic resonance imaging(MRI).METHODS:A case-control study.Eighteen subjects with AACE and eighteen HCs were enrolled.MRI scanning data were conducted in target-controlled central gaze with a 3-Tesla magnetic resonance scanner.Extraocular muscles(EOMs)were scanned in contiguous image planes 2-mm thick spanning the EOM origins to the globe equator.To form posterior partial volumes(PPVs),the LR and MR cross-sections in the image planes 8,10,12,and 14 mm posterior to the globe were summed and multiplied by the 2-mm slice thickness.The data were classified according to the right eye,left eye,dominant eye,and non-dominant eye,and the differences in mean cross-sectional area,maximum cross-sectional area,and PPVs of the MR and LR muscle in the AACE group and HCs group were compared under the above classifications respectively.RESULTS:There were no significant differences between the two groups of demographic characteristics.The mean cross-sectional area of the LR muscle was significantly greater in the AACE group than that in the HCs group in the non-dominant eyes(P=0.028).The maximum cross-sectional area of the LR muscle both in the dominant and non-dominant eye of the AACE group was significantly greater than the HCs group(P=0.009,P=0.016).For the dominant eye,the PPVs of the LR muscle were significantly greater in the AACE than that in the HCs group(P=0.013),but not in the MR muscle(P=0.698).CONCLUSION:The size and volume of muscles dominant eyes of AACE subjects change significantly to overcome binocular diplopia.The LR muscle become larger to compensate for the enhanced convergence in the AACE. 展开更多
关键词 acute acquired concomitant esotropia magnetic resonance imaging extraocular muscles
下载PDF
Non-volatile dynamically switchable color display via chalcogenide stepwise cavity resonators 被引量:1
10
作者 Kuan Liu Zhenyuan Lin +2 位作者 Bing Han Minghui Hong Tun Cao 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第1期16-27,共12页
High-resolution multi-color printing relies upon pixelated optical nanostructures,which is crucial to promote color display by producing nonbleaching colors,yet requires simplicity in fabrication and dynamic switching... High-resolution multi-color printing relies upon pixelated optical nanostructures,which is crucial to promote color display by producing nonbleaching colors,yet requires simplicity in fabrication and dynamic switching.Antimony trisulfide(Sb_(2)S_(3))is a newly rising chalcogenide material that possesses prompt and significant transition of its optical characteristics in the visible region between amorphous and crystalline phases,which holds the key to color-varying devices.Herein,we proposed a dynamically switchable color printing method using Sb_(2)S_(3)-based stepwise pixelated Fabry-Pérot(FP)cavities with various cavity lengths.The device was fabricated by employing a direct laser patterning that is a less timeconsuming,more approachable,and low-cost technique.As switching the state of Sb_(2)S_(3) between amorphous and crystalline,the multi-color of stepwise pixelated FP cavities can be actively changed.The color variation is due to the profound change in the refractive index of Sb_(2)S_(3) over the visible spectrum during its phase transition.Moreover,we directly fabricated sub-50 nm nano-grating on ultrathin Sb_(2)S_(3) laminate via microsphere 800-nm femtosecond laser irradiation in far field.The minimum feature size can be further decreased down to~45 nm(λ/17)by varying the thickness of Sb_(2)S_(3) film.Ultrafast switchable Sb_(2)S_(3) photonic devices can take one step toward the next generation of inkless erasable papers or displays and enable information encryption,camouflaging surfaces,anticounterfeiting,etc.Importantly,our work explores the prospects of rapid and rewritable fabrication of periodic structures with nano-scale resolution and can serve as a guideline for further development of chalcogenide-based photonics components. 展开更多
关键词 TUNABLE color displays Fabry-Pérot cavity resonators color printing chalcogenide materials
下载PDF
High-grade pancreatic intraepithelial neoplasia diagnosed based on changes in magnetic resonance cholangiopancreatography findings:A case report 被引量:2
11
作者 Nao Furuya Atsushi Yamaguchi +13 位作者 Naohiro Kato Syuhei Sugata Takuro Hamada Takeshi Mizumoto Yuzuru Tamaru Ryusaku Kusunoki Toshio Kuwai Hirotaka Kouno Kazuya Kuraoka Yoshiyuki Shibata Sho Tazuma Takeshi Sudo Hiroshi Kohno Shiro Oka 《World Journal of Clinical Cases》 SCIE 2024年第8期1487-1496,共10页
BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most ... BACKGROUND High-grade pancreatic intraepithelial neoplasia(PanIN)exhibits no mass and is not detected by any examination modalities.However,it can be diagnosed by pancreatic juice cytology from indirect findings.Most previous cases were diagnosed based on findings of a focal stricture of the main pancreatic duct(MPD)and caudal MPD dilatation and subsequent pancreatic juice cytology using endoscopic retrograde cholangiopancreatography(ERCP).We experienced a case of high-grade PanIN with an unclear MPD over a 20-mm range,but without caudal MPD dilatation on magnetic resonance cholangiopancreatography(MRCP).CASE SUMMARY A 60-year-old female patient underwent computed tomography for a follow-up of uterine cancer post-excision,which revealed pancreatic cysts.MRCP revealed an unclear MPD of the pancreatic body at a 20-mm length without caudal MPD dilatation.Thus,course observation was performed.After 24 mo,MRCP revealed an increased caudal MPD caliber and a larger pancreatic cyst.We performed ERCP and detected atypical cells suspected of adenocarcinoma by serial pancreatic juice aspiration cytology examination.We performed a distal pancreatectomy and obtained a histopathological diagnosis of high-grade PanIN.Pancreatic parenchyma invasion was not observed,and curative resection was achieved.CONCLUSION High-grade Pan-IN may cause MPD narrowing in a long range without caudal MPD dilatation. 展开更多
关键词 Pancreatic cancer Pancreatic intraepithelial neoplasm High-grade pancreatic intraepithelial neoplasm Magnetic resonance cholangiopancreatography Carcinoma in situ Case report
下载PDF
Resonantly enhanced second-and third-harmonic generation in dielectric nonlinear metasurfaces 被引量:1
12
作者 Ji Tong Wang Pavel Tonkaev +5 位作者 Kirill Koshelev Fangxing Lai Sergey Kruk Qinghai Song Yuri Kivshar Nicolae C.Panoiu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第5期5-19,共15页
Nonlinear dielectric metasurfaces provide a promising approach to control and manipulate frequency conversion optical processes at the nanoscale,thus facilitating both advances in fundamental research and the developm... Nonlinear dielectric metasurfaces provide a promising approach to control and manipulate frequency conversion optical processes at the nanoscale,thus facilitating both advances in fundamental research and the development of new practical applications in photonics,lasing,and sensing.Here,we employ symmetry-broken metasurfaces made of centrosymmetric amorphous silicon for resonantly enhanced second-and third-order nonlinear optical response.Exploiting the rich physics of optical quasi-bound states in the continuum and guided mode resonances,we comprehensively study through rigorous numerical calculations the relative contribution of surface and bulk effects to second-harmonic generation(SHG)and the bulk contribution to third-harmonic generation(THG) from the meta-atoms.Next,we experimentally achieve optical resonances with high quality factors,which greatly boosts light-matter interaction,resulting in about 550 times SHG enhancement and nearly 5000-fold increase of THG.A good agreement between theoretical predictions and experimental measurements is observed.To gain deeper insights into the physics of the investigated nonlinear optical processes,we further numerically study the relation between nonlinear emission and the structural asymmetry of the metasurface and reveal that the generated harmonic signals arising from linear sharp resonances are highly dependent on the asymmetry of the meta-atoms.Our work suggests a fruitful strategy to enhance the harmonic generation and effectively control different orders of harmonics in all-dielectric metasurfaces,enabling the development of efficient active photonic nanodevices. 展开更多
关键词 second-harmonic generation third-harmonic generation bound state in the continuum guided mode resonance all-dielectric metasurfaces nonlinear optics
下载PDF
Outcomes and efficacy of magnetic resonance imaging-compatible sacral nerve stimulator for management of fecal incontinence: A multi-institutional study 被引量:1
13
作者 Binit Katuwal Amy Thorsen +5 位作者 Kunal Kochar Ryba Bhullar Ray King Ernesto Raul Drelichman Vijay K Mittal Jasneet Singh Bhullar 《World Journal of Radiology》 2024年第2期32-39,共8页
BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a we... BACKGROUND Fecal incontinence(FI)is an involuntary passage of fecal matter which can have a significant impact on a patient’s quality of life.Many modalities of treatment exist for FI.Sacral nerve stimulation is a well-established treatment for FI.Given the increased need of magnetic resonance imaging(MRI)for diagnostics,the In-terStim which was previously used in sacral nerve stimulation was limited by MRI incompatibility.Medtronic MRI-compatible InterStim was approved by the United States Food and Drug Administration in August 2020 and has been widely used.AIM To evaluate the efficacy,outcomes and complications of the MRI-compatible InterStim.METHODS Data of patients who underwent MRI-compatible Medtronic InterStim placement at UPMC Williamsport,University of Minnesota,Advocate Lutheran General Hospital,and University of Wisconsin-Madison was pooled and analyzed.Patient demographics,clinical features,surgical techniques,complications,and outcomes were analyzed.Strengthening the Reporting of Observational studies in Epidemiology(STROBE)cross-sectional reporting guidelines were used.RESULTS Seventy-three patients had the InterStim implanted.The mean age was 63.29±12.2 years.Fifty-seven(78.1%)patients were females and forty-two(57.5%)patients had diabetes.In addition to incontinence,overlapping symptoms included diarrhea(23.3%),fecal urgency(58.9%),and urinary incontinence(28.8%).Fifteen(20.5%)patients underwent Peripheral Nerve Evaluation before proceeding to definite implant placement.Thirty-two(43.8%)patients underwent rechargeable InterStim placement.Three(4.1%)patients needed removal of the implant.Migration of the external lead connection was observed in 7(9.6%)patients after the stage I procedure.The explanation for one patient was due to infection.Seven(9.6%)patients had other complications like nerve pain,hematoma,infection,lead fracture,and bleeding.The mean follow-up was 6.62±3.5 mo.Sixty-eight(93.2%)patients reported significant improvement of symptoms on follow-up evaluation.CONCLUSION This study shows promising results with significant symptom improvement,good efficacy and good patient outcomes with low complication rates while using MRI compatible InterStim for FI.Further long-term follow-up and future studies with a larger patient population is recommended. 展开更多
关键词 Fecal incontinence Sacral nerve stimulation InterStim Magnetic resonance imaging Sacral neuromodulation
下载PDF
Potential applications of 7 Tesla magnetic resonance imaging in paediatric neuroimaging:Feasibility and challenges 被引量:1
14
作者 Arosh S Perera Molligoda Arachchige Letterio S Politi 《World Journal of Clinical Pediatrics》 2024年第2期1-6,共6页
The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing i... The integration of 7 Tesla magnetic resonance imaging(7 T MRI)in adult patients has marked a revolutionary stride in radiology.In this article we explore the feasibility of 7 T MRI in paediatric practice,emphasizing its feasibility,applications,challenges,and safety considerations.The heightened resolution and tissue contrast of 7 T MRI offer unprecedented diagnostic accuracy,particularly in neuroimaging.Applications range from neuro-oncology to neonatal brain imaging,showcasing its efficacy in detecting subtle structural abnormalities and providing enhanced insights into neurological conditions.Despite the promise,challenges such as high cost,discomfort,and safety concerns necessitate careful consideration.Research suggests that,with precautions,7 T MRI is feasible in paediatrics,yet ongoing studies and safety assessments are imperative. 展开更多
关键词 7 Tesla magnetic resonance imaging Pediatric imaging FEASIBILITY CHALLENGES
下载PDF
Tunable superconducting resonators via on-chip control of local magnetic field
15
作者 王晨光 岳文诚 +13 位作者 涂学凑 迟天圆 郭婷婷 吕阳阳 董思宁 曹春海 张蜡宝 贾小氢 孙国柱 康琳 陈健 王永磊 王华兵 吴培亨 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第5期674-679,共6页
Superconducting microwave resonators play a pivotal role in superconducting quantum circuits.The ability to finetune their resonant frequencies provides enhanced control and flexibility.Here,we introduce a frequency-t... Superconducting microwave resonators play a pivotal role in superconducting quantum circuits.The ability to finetune their resonant frequencies provides enhanced control and flexibility.Here,we introduce a frequency-tunable superconducting coplanar waveguide resonator.By applying electrical currents through specifically designed ground wires,we achieve the generation and control of a localized magnetic field on the central line of the resonator,enabling continuous tuning of its resonant frequency.We demonstrate a frequency tuning range of 54.85 MHz in a 6.21-GHz resonator.This integrated and tunable resonator holds great potential as a dynamically tunable filter and as a key component of communication buses and memory elements in superconducting quantum computing. 展开更多
关键词 superconducting resonator NBN kinetic inductance tunable resonator
下载PDF
Parametric resonance of axially functionally graded pipes conveying pulsating fluid
16
作者 Jie JING Xiaoye MAO +1 位作者 Hu DING Liqun CHEN 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第2期239-260,共22页
Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functio... Based on the generalized Hamilton's principle,the nonlinear governing equation of an axially functionally graded(AFG)pipe is established.The non-trivial equilibrium configuration is superposed by the modal functions of a simply supported beam.Via the direct multi-scale method,the response and stability boundary to the pulsating fluid velocity are solved analytically and verified by the differential quadrature element method(DQEM).The influence of Young's modulus gradient on the parametric resonance is investigated in the subcritical and supercritical regions.In general,the pipe in the supercritical region is more sensitive to the pulsating excitation.The nonlinearity changes from hard to soft,and the non-trivial equilibrium configuration introduces more frequency components to the vibration.Besides,the increasing Young's modulus gradient improves the critical pulsating flow velocity of the parametric resonance,and further enhances the stability of the system.In addition,when the temperature increases along the axial direction,reducing the gradient parameter can enhance the response asymmetry.This work further complements the theoretical analysis of pipes conveying pulsating fluid. 展开更多
关键词 pipe conveying fluid axially functionally graded supercritical resonance multi-scale method parametric resonance
下载PDF
Enhanced resonance frequency in Co2FeAl thin film with different thicknesses grown on flexible graphene substrate
17
作者 周偲 袁少康 +8 位作者 朱登玉 白宇明 王韬 刘福福 潘禄禄 冯存芳 张博涵 何大平 汪胜祥 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期618-622,共5页
The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with un... The flexible materials exhibit more favorable properties than most rigid substrates in flexibility,weight saving,mechanical reliability,and excellent environmental toughness.Particularly,flexible graphene film with unique mechanical properties was extensively explored in high frequency devices.Herein,we report the characteristics of structure and magnetic properties at high frequency of Co2FeAl thin film with different thicknesses grown on flexible graphene substrate at room temperature.The exciting finding for the columnar structure of Co2FeAl thin film lays the foundation for excellent high frequency property of Co2FeAl/flexible graphene structure.In-plane magnetic anisotropy field varying with increasing thickness of Co2FeAl thin film can be obtained by measurement of ferromagnetic resonance,which can be ascribed to the enhancement of crystallinity and the increase of grain size.Meanwhile,the resonance frequency which can be achieved by the measurement of vector network analyzer with the microstrip method increases with increasing thickness of Co2FeAl thin film.Moreover,in our case with graphene film,the resonance magnetic field is quite stable though folded for twenty cycles,which demonstrates that good flexibility of graphene film and the stability of high frequency magnetic property of Co2FeAl thin film grown on flexible graphene substrate.These results are promising for the design of microwave devices and wireless communication equipment. 展开更多
关键词 enhanced resonance frequency magnetic resonance field flexible graphene substrate
下载PDF
Two Distinct Charge Orders in Infinite-Layer PrNiO_(2+δ) Revealed by Resonant X-Ray Diffraction
18
作者 Xiaolin Ren Ronny Sutarto +9 位作者 Qiang Gao Qisi Wang Jiarui Li Yao Wang Tao Xiang Jiangping Hu J.Chang Riccardo Comin X.J.Zhou Zhihai Zhu 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第11期154-169,共16页
Research of infinite-layer nickelates has unveiled a broken translation symmetry,which has sparked significant interest in its root,its relationship to superconductivity,and its comparison to charge order in cuprates.... Research of infinite-layer nickelates has unveiled a broken translation symmetry,which has sparked significant interest in its root,its relationship to superconductivity,and its comparison to charge order in cuprates.In this study,resonant x-ray scattering measurements were performed on thin films of infinite-layer PrNiO_(2+δ).The results show significant differences in the superlattice reflection at the Ni L_(3) absorption edge compared to that at the Pr M_(5) resonance in their dependence on energy,temperature,and local symmetry.These differences point to two distinct charge orders,although they share the same in-plane wavevectors.It is suggested that these dissimilarities could be linked to the excess oxygen dopants,given that the resonant reflections were observed in an incompletely reduced PrNiO_(2+δ)film.Furthermore,azimuthal analysis indicates that the oxygen ligands likely play a crucial role in the charge modulation revealed at the Ni L_(3) resonance. 展开更多
关键词 film. resonANT CHARGE
下载PDF
Bound and Resonating Multiquark Configurations
19
作者 Jean-Marc Richard 《Chinese Physics Letters》 SCIE EI CAS CSCD 2024年第8期8-12,共5页
We review the predictions of quark models for multiquark configurations that are bound or resonant states,and compare different methods for estimating the properties of resonances.
关键词 QUARK CONFIGURATION resonANT
下载PDF
Inter-well internal resonance analysis of rectangular asymmetric cross-ply bistable composite laminated cantilever shell under transverse foundation excitation
20
作者 Lele REN Wei ZHANG Yufei ZHANG 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI CSCD 2024年第8期1353-1370,共18页
The chaotic dynamic snap-through and complex nonlinear vibrations are investigated in a rectangular asymmetric cross-ply bistable composite laminated cantilever shell,in cases of 1:2 inter-well internal resonance and ... The chaotic dynamic snap-through and complex nonlinear vibrations are investigated in a rectangular asymmetric cross-ply bistable composite laminated cantilever shell,in cases of 1:2 inter-well internal resonance and primary resonance.The transverse foundation excitation is applied to the fixed end of the structure,and the other end is in a free state.The first-order approximate multiple scales method is employed to perform the perturbation analysis on the dimensionless two-degree-of-freedom ordinary differential motion control equation.The four-dimensional averaged equations are derived in both polar and rectangular coordinate forms.Deriving from the obtained frequency-amplitude and force-amplitude response curves,a detailed analysis is conducted to examine the impacts of excitation amplitude,damping coefficient,and tuning parameter on the nonlinear internal resonance characteristics of the system.The nonlinear softening characteristic is exhibited in the upper stable-state,while the lower stable-state demonstrates the softening and linearity characteristics.Numerical simulation is carried out using the fourth-order Runge-Kutta method,and a series of nonlinear response curves are plotted.Increasing the excitation amplitude further elucidates the global bifurcation and chaotic dynamic snap-through characteristics of the bistable cantilever shell. 展开更多
关键词 bistable composite laminated cantilever shell inter-well internal resonance primary resonance chaotic dynamic snap-through complex nonlinear vibration
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部