In order to study the effect of element Nb on the microstructure and properties of the biomedical β-type Ti-Mo based alloys,Ti-15Mo-xNb(x=5,10,15 and 20 in %) alloys were investigated.The dry wear resistance of β-...In order to study the effect of element Nb on the microstructure and properties of the biomedical β-type Ti-Mo based alloys,Ti-15Mo-xNb(x=5,10,15 and 20 in %) alloys were investigated.The dry wear resistance of β-type Ti-15Mo-xNb alloys against Gr15 ball was investigated on CJS111A ball-disk wear instrument.Experimental results indicate that crystal structure and morphology of the Ti-15Mo-xNb alloys are sensitive to their Nb contents.Ti-15Mo-xNb alloys match those for β phase peaks and no any phases are found.The Vickers hardness values of all the Ti-15Mo-xNb alloys are higher than HV200.The compression yield strength of the Ti-15Mo-5Nb alloy is the lowest and that of the Ti-15Mo-10Nb alloy is the highest.For all the Ti-15Mo-xNb alloys,the friction coefficient is not constant but takes a higher value.In dry condition,SEM study reveals deep parallel scars on the wear surfaces of all the Ti-15Mo-xNb alloys under different loads.The friction coefficient of the Ti-15Mo-5Nb alloy under 1 N is the lowest.The wear principal mechanism for Ti-15Mo-xNb alloys is adhesive wear.展开更多
A layer of porous film containing Ca and P was prepared by the micro-arc oxidation method on the surface of a novel near β biomedical Ti-3Zr-2Sn-3Mo-25Nb alloy, and then NH2- active group was introduced to the films ...A layer of porous film containing Ca and P was prepared by the micro-arc oxidation method on the surface of a novel near β biomedical Ti-3Zr-2Sn-3Mo-25Nb alloy, and then NH2- active group was introduced to the films by activation treatment. The phase composition, surface micro-topography and elemental characteristics of the micro-arc oxidation films were investigated with XRD, SEM, EDS and XPS, and the osteoinduction of the micro-arc oxidation films was tested using the simulated body fluid immersion, the in-vitro osteoblast cultivation test and animal experiment. The results show that the oxide layer is a kind of porous ceramic intermixture and contains Ca and P. The films in the simulated body fluid can induce apatite formation, resulting in excellent bioactivity. The cell test discovers that osteoblasts can grow well on the surface of micro-arc oxidation films. And the Ti-3Zr-2Sn-3Mo-25Nb biomedical alloy coated with active porous calcium-phosphate films shows better osteoinduction in vivo.展开更多
To develop novel β-type biomedical titanium alloys,a series of Ti-15Mo-xNb alloys(x=0,5,10 and 15,mass fraction in%) were designed and prepared by using vacuum arc melting method.The present study focused on the ef...To develop novel β-type biomedical titanium alloys,a series of Ti-15Mo-xNb alloys(x=0,5,10 and 15,mass fraction in%) were designed and prepared by using vacuum arc melting method.The present study focused on the effect of Nb addition on the microstructure,mechanical properties and castability of Ti-15 Mo alloy.Phase analysis and microstructure observation show that all the alloys consist of single β phase and the equiaxed β grain is refined with increasing Nb content.These β-type Ti-15Mo-xNb alloys exhibit good plasticity and rather low compression elastic modulus(in the range of 18.388-19.365 GPa).After Nb addition,the compression yield strength of the alloys increases.With increasing Nb content,the micro-hardness of the alloys decreases.The alloys exhibit obvious fibrous strip microstructure after cold compression deformation.The castability test shows that the castability of the alloys after Nb addition decreases and that of the Ti-15 Mo alloy is the highest(92.01%).展开更多
The influence of ageing time on microstructure and mechanical properties of low-cost beta (LCB) titanium alloy with a chemical composition of Ti-6.6Mo-4.5Fe-1.5Al was investigated. The correlation between microstruc...The influence of ageing time on microstructure and mechanical properties of low-cost beta (LCB) titanium alloy with a chemical composition of Ti-6.6Mo-4.5Fe-1.5Al was investigated. The correlation between microstructure and fatigue crack initiation and growth was also studied. Increasing ageing time tended to increase the volume fraction of the secondary α-precipitates, β-grain size and partial spheroidization of primary α-phase. The maximum tensile strength (1565 MPa) and fatigue limit (750 MPa) were obtained for the samples aged at 500 °C for 0.5 h, while the minimum ones of 1515 MPa and 625 MPa, respectively, were reported for the samples aged at 500 °C for 4 h. The samples aged at 500 °C for 4 h showed a transgranular fracture mode. However, the samples aged at 500 °C for 0.5 h revealed a mixture fracture mode of transgranular and intergranular. The formed cracks on the outer surface of the fatigue samples were found to propagate through the β-grains connecting the primary α-particles existing at the β-grain boundaries.展开更多
In this work,a near-beta Ti-5Al-5Mo-5V-1Cr-1Fe titanium alloy was fabricated by selective laser melting(SLM),and the microstructure evolution together with the mechanical properties was studied.The as-fabricated alloy...In this work,a near-beta Ti-5Al-5Mo-5V-1Cr-1Fe titanium alloy was fabricated by selective laser melting(SLM),and the microstructure evolution together with the mechanical properties was studied.The as-fabricated alloy showed columnarβgrains spreading over multiple layers and paralleling to the building direction.The distinct microstructure of as-fabricated alloy was composed of near-β(more than 98.1%)with a submicron cellular structure.Different SLM processing parameters such as hatch spacing could affect the microstructure of as-fabricated alloy,which could thus further significantly affect the mechanical properties of as-fabricated alloy.In addition,the as-fabricated alloy with the distinct microstructure exhibits yield strength of 818 MPa combined with elongation of more than 19%,which shows that SLM is a potential technology for manufacturing near-beta titanium components.展开更多
基金funded by the National Key Research and Development Program of China(No.2021YFB3700801)by the State Key Laboratory of Powder Metallurgy,Central South University,Changsha,China。
基金Project(20080440850) supported by China Postdoctoral Science FoundationProject(ZJY0605-02) supported by the Natural Science Foundation of Heilongjiang Province,ChinaProject(HIT.NSRIF.2012002) supported by the Fundamental Research Funds for the Central Universities,China
文摘In order to study the effect of element Nb on the microstructure and properties of the biomedical β-type Ti-Mo based alloys,Ti-15Mo-xNb(x=5,10,15 and 20 in %) alloys were investigated.The dry wear resistance of β-type Ti-15Mo-xNb alloys against Gr15 ball was investigated on CJS111A ball-disk wear instrument.Experimental results indicate that crystal structure and morphology of the Ti-15Mo-xNb alloys are sensitive to their Nb contents.Ti-15Mo-xNb alloys match those for β phase peaks and no any phases are found.The Vickers hardness values of all the Ti-15Mo-xNb alloys are higher than HV200.The compression yield strength of the Ti-15Mo-5Nb alloy is the lowest and that of the Ti-15Mo-10Nb alloy is the highest.For all the Ti-15Mo-xNb alloys,the friction coefficient is not constant but takes a higher value.In dry condition,SEM study reveals deep parallel scars on the wear surfaces of all the Ti-15Mo-xNb alloys under different loads.The friction coefficient of the Ti-15Mo-5Nb alloy under 1 N is the lowest.The wear principal mechanism for Ti-15Mo-xNb alloys is adhesive wear.
基金Project (2005CB623904) supported by the National Basic Research Program of ChinaProject (30770586) supported by the National Natural Science Foundation of China+1 种基金Project (31011120049) supported by the Australia-China special fund, International Science Linkages Program co-supported by the Department of Innovation, Industry, Science and Research of Australia, and the Ministry of Science and Technology and National Science Foundation of ChinaProject (2010ZDKG-96) supported by the major Subject of "13115" Programs of Shaan’xi Province, China
文摘A layer of porous film containing Ca and P was prepared by the micro-arc oxidation method on the surface of a novel near β biomedical Ti-3Zr-2Sn-3Mo-25Nb alloy, and then NH2- active group was introduced to the films by activation treatment. The phase composition, surface micro-topography and elemental characteristics of the micro-arc oxidation films were investigated with XRD, SEM, EDS and XPS, and the osteoinduction of the micro-arc oxidation films was tested using the simulated body fluid immersion, the in-vitro osteoblast cultivation test and animal experiment. The results show that the oxide layer is a kind of porous ceramic intermixture and contains Ca and P. The films in the simulated body fluid can induce apatite formation, resulting in excellent bioactivity. The cell test discovers that osteoblasts can grow well on the surface of micro-arc oxidation films. And the Ti-3Zr-2Sn-3Mo-25Nb biomedical alloy coated with active porous calcium-phosphate films shows better osteoinduction in vivo.
基金Project(QN2010-04)supported by the Youth Startup Fund of the Second Affiliated Hospital of Harbin Medical University,ChinaProject(2010-156)supported by the Medical Scientific Research Foundation of Heilongjiang Province Health Department,ChinaProject(HIT.NSRIF.2012002)supported by the Fundamental Research Funds for the Central Universities,China
文摘To develop novel β-type biomedical titanium alloys,a series of Ti-15Mo-xNb alloys(x=0,5,10 and 15,mass fraction in%) were designed and prepared by using vacuum arc melting method.The present study focused on the effect of Nb addition on the microstructure,mechanical properties and castability of Ti-15 Mo alloy.Phase analysis and microstructure observation show that all the alloys consist of single β phase and the equiaxed β grain is refined with increasing Nb content.These β-type Ti-15Mo-xNb alloys exhibit good plasticity and rather low compression elastic modulus(in the range of 18.388-19.365 GPa).After Nb addition,the compression yield strength of the alloys increases.With increasing Nb content,the micro-hardness of the alloys decreases.The alloys exhibit obvious fibrous strip microstructure after cold compression deformation.The castability test shows that the castability of the alloys after Nb addition decreases and that of the Ti-15 Mo alloy is the highest(92.01%).
文摘The influence of ageing time on microstructure and mechanical properties of low-cost beta (LCB) titanium alloy with a chemical composition of Ti-6.6Mo-4.5Fe-1.5Al was investigated. The correlation between microstructure and fatigue crack initiation and growth was also studied. Increasing ageing time tended to increase the volume fraction of the secondary α-precipitates, β-grain size and partial spheroidization of primary α-phase. The maximum tensile strength (1565 MPa) and fatigue limit (750 MPa) were obtained for the samples aged at 500 °C for 0.5 h, while the minimum ones of 1515 MPa and 625 MPa, respectively, were reported for the samples aged at 500 °C for 4 h. The samples aged at 500 °C for 4 h showed a transgranular fracture mode. However, the samples aged at 500 °C for 0.5 h revealed a mixture fracture mode of transgranular and intergranular. The formed cracks on the outer surface of the fatigue samples were found to propagate through the β-grains connecting the primary α-particles existing at the β-grain boundaries.
基金Project(2019B010943001)supported by Key-area Research and Development Program of Guangdong Province,ChinaProject(2020)supported by the Fund of State Key Laboratory of Powder Metallurgy,Central South University,China。
文摘In this work,a near-beta Ti-5Al-5Mo-5V-1Cr-1Fe titanium alloy was fabricated by selective laser melting(SLM),and the microstructure evolution together with the mechanical properties was studied.The as-fabricated alloy showed columnarβgrains spreading over multiple layers and paralleling to the building direction.The distinct microstructure of as-fabricated alloy was composed of near-β(more than 98.1%)with a submicron cellular structure.Different SLM processing parameters such as hatch spacing could affect the microstructure of as-fabricated alloy,which could thus further significantly affect the mechanical properties of as-fabricated alloy.In addition,the as-fabricated alloy with the distinct microstructure exhibits yield strength of 818 MPa combined with elongation of more than 19%,which shows that SLM is a potential technology for manufacturing near-beta titanium components.