To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resul...To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.展开更多
For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, t...For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, two new methods are proposed herein to obtain the γ-ray net peak count from the interlaced overlap peak in the HPGe cray spectrometer system, of which one is the symmetric conversion method based on Gaussian distribution and the other is where the energy average value of two close γ-rays is regarded as the γ-ray energy. The experimental results indicate that the two methods mentioned above are reliable and credible. This study is significant for the development of better γ-ray spectrum processing software for measuring complex γ-ray spectra concerning the nuclear reaction cross section, neutron activation analysis, and analysis of transuranium elements, using an HPGe detector.展开更多
The significant modifications to our recently constructed electron momentum spectrometer have been implemented. Compared with our previous report, the energy and the angle resolutions are significantly improved and re...The significant modifications to our recently constructed electron momentum spectrometer have been implemented. Compared with our previous report, the energy and the angle resolutions are significantly improved and reach △E = 0.45 eV, △θ = ±0.53° and △φ = ±0.84°, respectively. Moreover, the details of data reduction and the relation between azimuthal angle range and the sensitivity are discussed.展开更多
Three different approaches have been taken in order to get the mean spectral characteristics of ten vowels of putonghua(standard Chinese): The first approach is a classical one, in which the speech materials to be ana...Three different approaches have been taken in order to get the mean spectral characteristics of ten vowels of putonghua(standard Chinese): The first approach is a classical one, in which the speech materials to be analysed are the isolatedly uttered vowel sounds by individuals situated in an anechoic chamber, the spectral analysis is performed with a spectrometer consisting of a bank of third-展开更多
Since Wasserburg et al. applied computer technique to mass spectrometer in 1969, precision of isotope analysis has largely been improved and isotope geology developed rapidly. In 1970, Wasserburg and his co-workers me...Since Wasserburg et al. applied computer technique to mass spectrometer in 1969, precision of isotope analysis has largely been improved and isotope geology developed rapidly. In 1970, Wasserburg and his co-workers measured the isotope ratio of Sr in Colomera iron meteorite and determined an initial 87Sr/86Sr ratio of 0.698990+0.000047, known as BABI(Basaltic Achondrite Best Initial). A few years later, some geochronologists analysed the isotope composition of Nd with展开更多
基金This work was supported by the National Key R&D Program of China(Nos.2022YFF0709503,2022YFB1902700,2017YFC0602101)the Key Research and Development Program of Sichuan province(No.2023YFG0347)the Key Research and Development Program of Sichuan province(No.2020ZDZX0007).
文摘To detect radioactive substances with low activity levels,an anticoincidence detector and a high-purity germanium(HPGe)detector are typically used simultaneously to suppress Compton scattering background,thereby resulting in an extremely low detection limit and improving the measurement accuracy.However,the complex and expensive hardware required does not facilitate the application or promotion of this method.Thus,a method is proposed in this study to discriminate the digital waveform of pulse signals output using an HPGe detector,whereby Compton scattering background is suppressed and a low minimum detectable activity(MDA)is achieved without using an expensive and complex anticoincidence detector and device.The electric-field-strength and energy-deposition distributions of the detector are simulated to determine the relationship between pulse shape and energy-deposition location,as well as the characteristics of energy-deposition distributions for fulland partial-energy deposition events.This relationship is used to develop a pulse-shape-discrimination algorithm based on an artificial neural network for pulse-feature identification.To accurately determine the relationship between the deposited energy of gamma(γ)rays in the detector and the deposition location,we extract four shape parameters from the pulse signals output by the detector.Machine learning is used to input the four shape parameters into the detector.Subsequently,the pulse signals are identified and classified to discriminate between partial-and full-energy deposition events.Some partial-energy deposition events are removed to suppress Compton scattering.The proposed method effectively decreases the MDA of an HPGeγ-energy dispersive spectrometer.Test results show that the Compton suppression factors for energy spectra obtained from measurements on ^(152)Eu,^(137)Cs,and ^(60)Co radioactive sources are 1.13(344 keV),1.11(662 keV),and 1.08(1332 keV),respectively,and that the corresponding MDAs are 1.4%,5.3%,and 21.6%lower,respectively.
基金supported by the National Natural Science Foundation of China(Nos.11575090,11605099)the Young Key Teachers Training Program of He’nan Higher Education in China(No.2015GGJS-258)
文摘For a characteristic c-ray with interlaced overlap peak, and the case where its reliable and credible net count cannot be obtained using the current high-purity germanium(HPGe) multichannel γ-ray spectrum software, two new methods are proposed herein to obtain the γ-ray net peak count from the interlaced overlap peak in the HPGe cray spectrometer system, of which one is the symmetric conversion method based on Gaussian distribution and the other is where the energy average value of two close γ-rays is regarded as the γ-ray energy. The experimental results indicate that the two methods mentioned above are reliable and credible. This study is significant for the development of better γ-ray spectrum processing software for measuring complex γ-ray spectra concerning the nuclear reaction cross section, neutron activation analysis, and analysis of transuranium elements, using an HPGe detector.
基金supported by the National Natural Science Foundation of China (Grant No 10575062)Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No 20050003084)
文摘The significant modifications to our recently constructed electron momentum spectrometer have been implemented. Compared with our previous report, the energy and the angle resolutions are significantly improved and reach △E = 0.45 eV, △θ = ±0.53° and △φ = ±0.84°, respectively. Moreover, the details of data reduction and the relation between azimuthal angle range and the sensitivity are discussed.
文摘Three different approaches have been taken in order to get the mean spectral characteristics of ten vowels of putonghua(standard Chinese): The first approach is a classical one, in which the speech materials to be analysed are the isolatedly uttered vowel sounds by individuals situated in an anechoic chamber, the spectral analysis is performed with a spectrometer consisting of a bank of third-
文摘Since Wasserburg et al. applied computer technique to mass spectrometer in 1969, precision of isotope analysis has largely been improved and isotope geology developed rapidly. In 1970, Wasserburg and his co-workers measured the isotope ratio of Sr in Colomera iron meteorite and determined an initial 87Sr/86Sr ratio of 0.698990+0.000047, known as BABI(Basaltic Achondrite Best Initial). A few years later, some geochronologists analysed the isotope composition of Nd with