Scenarios for the τ mass measurement at the upgraded Beijing Electron-Positron Collider (BEPC- II ) are studied. A nested minimization procedure is used to optimize the data taking plan. It is found that by using f...Scenarios for the τ mass measurement at the upgraded Beijing Electron-Positron Collider (BEPC- II ) are studied. A nested minimization procedure is used to optimize the data taking plan. It is found that by using five energy points with the total integrated luminosity of 100 pb-1, the τ mass can be determined with a statistical error of 50 keV.展开更多
This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certif...This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.797, 0.16%; and 99.81%, 0.26% with, in all cases, a coverage factor (k) of 2 (P=95%). The purity results are consistent indicating that the combination of DSC, the MB method and CT provides a confident assessment of the purity of suitable CRMs like ferulic acid. (C) 2015 Chinese Pharmaceutical Association and Institute of Materia Medica, Chinese Academy of Medical Sciences. Production and hosting by Elsevier B.V.展开更多
基金Supported by National Natural Science Foundation of China (10775412, 10825524, 10935008)Instrument Developing Project of Chinese Academy of Sciences (YZ200713)+4 种基金Major State Basic Research Development Program (2009CB825203, 2009CB825206)the Knowledge Innovation Project of Chinese Academy of Sciences (KJCX2-YW-N29)RFBR 08-02-00328-a, 08-02-00251-a, 08-02-92200-NSFC-aSB RAS joint project No. 32 for fundamental researcher with CASDepartment of Energy (DE-FG02-04ER41291) (U. Hawaii)
文摘Scenarios for the τ mass measurement at the upgraded Beijing Electron-Positron Collider (BEPC- II ) are studied. A nested minimization procedure is used to optimize the data taking plan. It is found that by using five energy points with the total integrated luminosity of 100 pb-1, the τ mass can be determined with a statistical error of 50 keV.
基金financially supported by the Ministry of Science and Technology of the People's Republic of China (No.2007FY130100)Major Scientific and Technological Special Project for "Significant New Drugs Creation" of China during the 12th Five-Year Plan Period (No.2012ZX09301002-001-013)
文摘This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.797, 0.16%; and 99.81%, 0.26% with, in all cases, a coverage factor (k) of 2 (P=95%). The purity results are consistent indicating that the combination of DSC, the MB method and CT provides a confident assessment of the purity of suitable CRMs like ferulic acid. (C) 2015 Chinese Pharmaceutical Association and Institute of Materia Medica, Chinese Academy of Medical Sciences. Production and hosting by Elsevier B.V.