Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the...Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.展开更多
The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting o...The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting on an emulated weak transmission line. Thyristor switched capacitor bank was chosen because it is a well known topology, considering the very nature of the direct starting induction motors, which represents a highly inductive load, the use of switched reactors becomes unnecessary. Such fact minimizes the introduction of harmonics components, and also reduces the cost of the implementation. The binary disposition of the banks allows a variable Var compensation with sixteen steps, in this case. The solution makes use of low cost devices combined with sliding window voltage and current measurement algorithm and a PI control with dead band control for achieve the shown experimental results, where the system is able to manage a typically 20% voltage drop, reducing it to less than 4%. The schematic of the developed circuit, the control technique and a quite simple method to calculate the binary weight capacitors banks are also presented.展开更多
This paper reports the investigation of the location accuracy of a three-dimensional (3D) lightning-radiation-source locating system using sounding balloon measurements. By comparing the information from the balloon...This paper reports the investigation of the location accuracy of a three-dimensional (3D) lightning-radiation-source locating system using sounding balloon measurements. By comparing the information from the balloon-borne VHF transmitter flight path and locations using simple geometric models, the location uncertainties of sources both over and outside the network were estimated. For radiation sources inside the network and below an altitude of 7 km, the horizontal uncertainty was 12-48 m and the total mean value was 21 m (rms), and the vertical uncertainty was 20-78 m and the total mean value was 49 m (rms). Outside the network, the location uncertainties increased with distance. The geometric model showed that range and altitude errors increased as a function of the range squared whereas the range errors increased parabolically with distance, and that was confirmed by the covariance calculation results. The standard deviation was used inside the network and covariance was used outside the network. The results indicated that location errors from a simple geometric model exhibited good agreement with standard experimental data. The geometry of the network, set of measurements, and calculation method were verified as suitable. The chi-square values of the least squares goodness of fit algorithm were verified and the timing error (A/rms) Of the fitting formula was estimated. The distribution of the chi-square values was less than 5, corresponding to a timing error of 50-66 ns (rms).展开更多
文摘Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results.
文摘The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting on an emulated weak transmission line. Thyristor switched capacitor bank was chosen because it is a well known topology, considering the very nature of the direct starting induction motors, which represents a highly inductive load, the use of switched reactors becomes unnecessary. Such fact minimizes the introduction of harmonics components, and also reduces the cost of the implementation. The binary disposition of the banks allows a variable Var compensation with sixteen steps, in this case. The solution makes use of low cost devices combined with sliding window voltage and current measurement algorithm and a PI control with dead band control for achieve the shown experimental results, where the system is able to manage a typically 20% voltage drop, reducing it to less than 4%. The schematic of the developed circuit, the control technique and a quite simple method to calculate the binary weight capacitors banks are also presented.
基金supported by National Basic Research Program of China(Grant No.2014CB441404)the National Natural Science Foundation of China(Grant Nos.41375010,41075002,41305003)
文摘This paper reports the investigation of the location accuracy of a three-dimensional (3D) lightning-radiation-source locating system using sounding balloon measurements. By comparing the information from the balloon-borne VHF transmitter flight path and locations using simple geometric models, the location uncertainties of sources both over and outside the network were estimated. For radiation sources inside the network and below an altitude of 7 km, the horizontal uncertainty was 12-48 m and the total mean value was 21 m (rms), and the vertical uncertainty was 20-78 m and the total mean value was 49 m (rms). Outside the network, the location uncertainties increased with distance. The geometric model showed that range and altitude errors increased as a function of the range squared whereas the range errors increased parabolically with distance, and that was confirmed by the covariance calculation results. The standard deviation was used inside the network and covariance was used outside the network. The results indicated that location errors from a simple geometric model exhibited good agreement with standard experimental data. The geometry of the network, set of measurements, and calculation method were verified as suitable. The chi-square values of the least squares goodness of fit algorithm were verified and the timing error (A/rms) Of the fitting formula was estimated. The distribution of the chi-square values was less than 5, corresponding to a timing error of 50-66 ns (rms).