“三地一区”视域下高校“三电”实验课程教学改革与实践
1
作者 王鹏 操龙德 +1 位作者 章礼华 祁义红 《大学物理实验》 2023年第3期115-120,共6页
安徽“三地一区”政策的出台对高校人才培养提出了新的要求,尤其对创新型工科人才的需求出现井喷态势。然而,作为工科专业人才培养的专业基础课程“三电”实验教学滞后于社会形势发展,如教学培养目标与社会发展需求相脱节,实验资源无法... 安徽“三地一区”政策的出台对高校人才培养提出了新的要求,尤其对创新型工科人才的需求出现井喷态势。然而,作为工科专业人才培养的专业基础课程“三电”实验教学滞后于社会形势发展,如教学培养目标与社会发展需求相脱节,实验资源无法满足学生实际需要,教学方法与创新型人才培养不适应等问题。以传统与虚拟相融合、第一课堂与第二课堂相贯通、校内与校外相协同等多元的教学改革路径促进高校实验教学逐步对标“三地一区”对人才的要求,有效提升高校服务地方经济社会发展的能力。 展开更多
关键词 “三电”实验 多平台融合 嵌入式教学 “三地一区”
下载PDF
Automatic Voltage Regulator Test of Three Gorges Right Bank Hydropower Station 被引量:1
2
作者 Wu Tao Zhou Ji +5 位作者 Pu Jun Su Weimin Xie Huan Huo Chengxiang Deng Xiaojun Yao Qian 《Electricity》 2012年第3期24-29,共6页
Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the... Based on real-time digital simulations(RTDS),a laboratory environment similar to the real-time operation situation of the Three Gorges Hydropower Station is established.Then,the causes for the power fluctuation of the second generator by errors in the rotor rotating speed calculation are found,and the tuning method of the speed related parameters are given.The damping and reverse tuning characteristics of power system stabilizers(PSSs)in the digital automatic voltage regulator(AVR)are compared and investigated in the frequency range of 0.18-1.1 Hz.The efficiency of the proposed tuning method for ensuring power system stability is verified by RTDS.Finally,field tests show the validity of the laboratory test results. 展开更多
关键词 power system stabilizers (PSS) angular speed oscillating reactance real-time digital simulation (RTDS)
下载PDF
Direct on Line Starting Induction Motor with Thyristor Switched Capacitor Based Voltage Regulation
3
作者 E.P.da Silveira R.C. Pires A.T.L.de Almeida A.J.J. Rezek 《Journal of Energy and Power Engineering》 2010年第9期49-55,共7页
The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting o... The purpose of this paper is to show a laboratory scale implementation of a Thyristor Switched Capacitors (TSC) as an alternative for voltage regulation during a direct on line three-phase induction motor starting on an emulated weak transmission line. Thyristor switched capacitor bank was chosen because it is a well known topology, considering the very nature of the direct starting induction motors, which represents a highly inductive load, the use of switched reactors becomes unnecessary. Such fact minimizes the introduction of harmonics components, and also reduces the cost of the implementation. The binary disposition of the banks allows a variable Var compensation with sixteen steps, in this case. The solution makes use of low cost devices combined with sliding window voltage and current measurement algorithm and a PI control with dead band control for achieve the shown experimental results, where the system is able to manage a typically 20% voltage drop, reducing it to less than 4%. The schematic of the developed circuit, the control technique and a quite simple method to calculate the binary weight capacitors banks are also presented. 展开更多
关键词 Induction motor thyristor switched capacitor voltage regulation
下载PDF
Experimental study on location accuracy of a 3D VHF lightning-radiation-source locating network 被引量:3
4
作者 ZHANG GuangShu LI YaJun +3 位作者 WANG YanHui ZHANG Tong WU Bin LIU YanXiu 《Science China Earth Sciences》 SCIE EI CAS CSCD 2015年第11期2034-2048,共15页
This paper reports the investigation of the location accuracy of a three-dimensional (3D) lightning-radiation-source locating system using sounding balloon measurements. By comparing the information from the balloon... This paper reports the investigation of the location accuracy of a three-dimensional (3D) lightning-radiation-source locating system using sounding balloon measurements. By comparing the information from the balloon-borne VHF transmitter flight path and locations using simple geometric models, the location uncertainties of sources both over and outside the network were estimated. For radiation sources inside the network and below an altitude of 7 km, the horizontal uncertainty was 12-48 m and the total mean value was 21 m (rms), and the vertical uncertainty was 20-78 m and the total mean value was 49 m (rms). Outside the network, the location uncertainties increased with distance. The geometric model showed that range and altitude errors increased as a function of the range squared whereas the range errors increased parabolically with distance, and that was confirmed by the covariance calculation results. The standard deviation was used inside the network and covariance was used outside the network. The results indicated that location errors from a simple geometric model exhibited good agreement with standard experimental data. The geometry of the network, set of measurements, and calculation method were verified as suitable. The chi-square values of the least squares goodness of fit algorithm were verified and the timing error (A/rms) Of the fitting formula was estimated. The distribution of the chi-square values was less than 5, corresponding to a timing error of 50-66 ns (rms). 展开更多
关键词 3D lightning-radiation-source locating network location accuracy standard deviation geometric model theoretical error