The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear micr...The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear microsurgery, new methods are required to train the doctors. It is necessary and of practical significance to apply VR to the ear micro-operation, which is a functional operation with high precision and great difficulties. In this article, medical VR applications were reviewed. The application of VR to the ear microsurgery was discussed and the virtual ear microsurgery system was designed.展开更多
AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic ...AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation.展开更多
There is increasing public concern about biological interactions with and the potential health effects of low frequency electric and magnetic fields. Recently, the ICNIRP (International Commission on Non-Ionizing Rad...There is increasing public concern about biological interactions with and the potential health effects of low frequency electric and magnetic fields. Recently, the ICNIRP (International Commission on Non-Ionizing Radiation Protection) has published new exposure guidelines with regard to these fields. The aim of this paper is to demonstrate the calculation of the currents and electric fields induced in the human body by external electric fields at 60 Hz, using numerical human models of anatomically-realistic human bodies, and to compare those results with the basic restrictions proposed by the new guidelines. As a result, in the case that a human is exposed to an electric field of 1 kV/m at 60 Hz the short-circuit current of 18 μA flows though the ankles. Furthermore, the electric field of 40 mV/m in the nervous tissue of the adult model is induced by exposure to external electric fields at the reference level, which is enough smaller than the basic restrictions established in the ICNIRP guidelines for occupational exposure.展开更多
基金The Scientific Research Fund of ShanghaiScience Committee( 0 3 411980 8) and the Science and TechnologySpecial Fund of Pudong New District( PKJ2 0 0 3 -4 1)
文摘The broad application of virtual reality (VR) to medicine has been of great value. The virtual surgery is one of technically difficult applications. With the expansion of the increasingly fine and complicated ear microsurgery, new methods are required to train the doctors. It is necessary and of practical significance to apply VR to the ear micro-operation, which is a functional operation with high precision and great difficulties. In this article, medical VR applications were reviewed. The application of VR to the ear microsurgery was discussed and the virtual ear microsurgery system was designed.
基金Supported by A Grant from the Department of Science & Technology of Hebei Province, No. 052761659
文摘AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (X^2 = 0.250, 0.677, P 〉 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI, which instructs micro-invasive operation of spleen and increase the safety of operation.
文摘There is increasing public concern about biological interactions with and the potential health effects of low frequency electric and magnetic fields. Recently, the ICNIRP (International Commission on Non-Ionizing Radiation Protection) has published new exposure guidelines with regard to these fields. The aim of this paper is to demonstrate the calculation of the currents and electric fields induced in the human body by external electric fields at 60 Hz, using numerical human models of anatomically-realistic human bodies, and to compare those results with the basic restrictions proposed by the new guidelines. As a result, in the case that a human is exposed to an electric field of 1 kV/m at 60 Hz the short-circuit current of 18 μA flows though the ankles. Furthermore, the electric field of 40 mV/m in the nervous tissue of the adult model is induced by exposure to external electric fields at the reference level, which is enough smaller than the basic restrictions established in the ICNIRP guidelines for occupational exposure.