A comprehensive acoustical test was conducted in the traditional Ch ine se in-house theater, the theater of Shi`s residence in Tianjin. The measured pa rameters include reverberation time, clarity, lateral reflectance...A comprehensive acoustical test was conducted in the traditional Ch ine se in-house theater, the theater of Shi`s residence in Tianjin. The measured pa rameters include reverberation time, clarity, lateral reflectance and IACC. Prim ary analysis was done with the test result.展开更多
Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of...Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of laboratory pull-out tests were conducted to comprehensively investigate the effects of different pull-out loading rates on the mechanical performance and failure characteristics of fully grouted bolts.The results show that the mechanical performance of the anchored specimen presents obvious loading rate dependence and shear enhancement characteristics.With the increase of the pull-out loading rates,the maximum pull-out load increases,the displacement and time corresponding to the maximum pull-out load decrease.The accumulated acoustic emission(AE)counts,AE energy and AE events all decrease with the increase of the pull-out loading rates.The AE peak frequency has obvious divisional distribution characteristics and the amplitude is mainly distributed between 50-80 dB.With the increase of the pull-out loading rates,the local strain of the anchoring interface increases and the failure of the anchoring interface transfers to the interior of the resin grout.The accumulated AE counts are used to evaluate the damage parameter of the anchoring interface during the whole pull-out process.The analytical results are in good agreement with the experimental results.The research results may provide guidance for the support design and performance monitoring of fully grouted bolts.展开更多
In order to cut down excessive experiments, acoustic response of the different fan ducted discharge (equipment) was studied based on numerical method. The sound pressure level(SPL) in each component of a duct-plenum-r...In order to cut down excessive experiments, acoustic response of the different fan ducted discharge (equipment) was studied based on numerical method. The sound pressure level(SPL) in each component of a duct-plenum-reverberant room model was drawn and SPL deviation was analyzed. The trends of the curves were explained by the diffracti on and end reflection at the duct discharge. Models with different room dimensions, duct lengths, duct cross sections, duct locations and duct elbow were constructed, and their response was analyzed and compared. The results show that the SPL curves are smooth in the duct discharge cross section, but seriously fluctuant in the reverberant room; SPL in the duct discharge is only sensitive to duct dimensions, while that of the reverberant room is regularly influenced by all the dimension and arrangement factors. Small room and short duct help to increase room SPL. Elbow has an indistinct influence on all the components’ sound field. Finally, suggestion to reduce the deviation of experiment results was proposed.展开更多
文摘A comprehensive acoustical test was conducted in the traditional Ch ine se in-house theater, the theater of Shi`s residence in Tianjin. The measured pa rameters include reverberation time, clarity, lateral reflectance and IACC. Prim ary analysis was done with the test result.
基金Projects(51925402,U1710258,52004172)supported by the National Natural Science Foundation of ChinaProject(20201102004)supported by the Science and Technology Department of Shanxi Province,China。
文摘Due to the influence of mining disturbance stress,it is of great significance to better understand the bearing characteristics of fully grouted bolts under different pull-out loading rates.For this purpose,a series of laboratory pull-out tests were conducted to comprehensively investigate the effects of different pull-out loading rates on the mechanical performance and failure characteristics of fully grouted bolts.The results show that the mechanical performance of the anchored specimen presents obvious loading rate dependence and shear enhancement characteristics.With the increase of the pull-out loading rates,the maximum pull-out load increases,the displacement and time corresponding to the maximum pull-out load decrease.The accumulated acoustic emission(AE)counts,AE energy and AE events all decrease with the increase of the pull-out loading rates.The AE peak frequency has obvious divisional distribution characteristics and the amplitude is mainly distributed between 50-80 dB.With the increase of the pull-out loading rates,the local strain of the anchoring interface increases and the failure of the anchoring interface transfers to the interior of the resin grout.The accumulated AE counts are used to evaluate the damage parameter of the anchoring interface during the whole pull-out process.The analytical results are in good agreement with the experimental results.The research results may provide guidance for the support design and performance monitoring of fully grouted bolts.
文摘In order to cut down excessive experiments, acoustic response of the different fan ducted discharge (equipment) was studied based on numerical method. The sound pressure level(SPL) in each component of a duct-plenum-reverberant room model was drawn and SPL deviation was analyzed. The trends of the curves were explained by the diffracti on and end reflection at the duct discharge. Models with different room dimensions, duct lengths, duct cross sections, duct locations and duct elbow were constructed, and their response was analyzed and compared. The results show that the SPL curves are smooth in the duct discharge cross section, but seriously fluctuant in the reverberant room; SPL in the duct discharge is only sensitive to duct dimensions, while that of the reverberant room is regularly influenced by all the dimension and arrangement factors. Small room and short duct help to increase room SPL. Elbow has an indistinct influence on all the components’ sound field. Finally, suggestion to reduce the deviation of experiment results was proposed.