AIM To assess the feasibility and safety of a novel enteroscope,negative-pressure suction endoscope in examining the small intestine of a porcine model.METHODS In vitro experiments in small intestinal loops from 20pig...AIM To assess the feasibility and safety of a novel enteroscope,negative-pressure suction endoscope in examining the small intestine of a porcine model.METHODS In vitro experiments in small intestinal loops from 20pigs and in vivo experiments in 20 living pigs were conducted.RESULTS In in vitro experiments,a negative pressure of>0.06MPa was necessary for optimal visualization of the intestine,and this pressure did not cause gross or histological damage to the mucosa.For satisfactory examination of the small intestine in vivo,higher negative pressure(>1.00 MPa)was required.Despite this higher pressure,the small intestine did not show any gross or microscopic damage in the suctioned areas.The average time of examination in the living animals was 60±7.67 min.The animals did not experience any apparent ill effects from the procedure.CONCLUSION Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases.展开更多
This paper proposes to use the blockwise empirical likelihood (EL) method to construct the confidence regions for the regression vector β in a partially linear model under negatively associated errors. It is shown ...This paper proposes to use the blockwise empirical likelihood (EL) method to construct the confidence regions for the regression vector β in a partially linear model under negatively associated errors. It is shown that the blockwise EL ratio statistic for β is asymptotically χ^2 distributed. The result is used to obtain an EL-based confidence region for β. Results of a simulation study on the finite sample performance of the proposed confidence regions are reported.展开更多
文摘AIM To assess the feasibility and safety of a novel enteroscope,negative-pressure suction endoscope in examining the small intestine of a porcine model.METHODS In vitro experiments in small intestinal loops from 20pigs and in vivo experiments in 20 living pigs were conducted.RESULTS In in vitro experiments,a negative pressure of>0.06MPa was necessary for optimal visualization of the intestine,and this pressure did not cause gross or histological damage to the mucosa.For satisfactory examination of the small intestine in vivo,higher negative pressure(>1.00 MPa)was required.Despite this higher pressure,the small intestine did not show any gross or microscopic damage in the suctioned areas.The average time of examination in the living animals was 60±7.67 min.The animals did not experience any apparent ill effects from the procedure.CONCLUSION Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases.
基金supported by the National Natural Science Foundation of China under Grant Nos.11271088and 11361011the Natural Science Foundation of Guangxi under Grant Nos.2013GXNSFAA019004 and2013GXNSFAA019007
文摘This paper proposes to use the blockwise empirical likelihood (EL) method to construct the confidence regions for the regression vector β in a partially linear model under negatively associated errors. It is shown that the blockwise EL ratio statistic for β is asymptotically χ^2 distributed. The result is used to obtain an EL-based confidence region for β. Results of a simulation study on the finite sample performance of the proposed confidence regions are reported.