Based on attenuated total reflection (ATR) and thermo-optic effect, the polymeric thin film planar optical waveguide is used as the temperature sensor, and the factors influencing the sensitivity of the temperature ...Based on attenuated total reflection (ATR) and thermo-optic effect, the polymeric thin film planar optical waveguide is used as the temperature sensor, and the factors influencing the sensitivity of the temperature sensor are comprehensively analyzed. Combined with theoretical analysis and experimental investigation, the sensitivity of the temperature sensor is related to the thicknesses of the upper cladding layer, the waveguide layer, the optical loss of the polymer material and the guided wave modes. The results show that the slope value about reflectivity and temperature, which stands for the sensitivity of the polymer thin film temperature sensor, is associated with the waveguide film thickness and the guided wave modes, and the slope value is the highest in the zero reflectance of a certain transverse electric (TE) mode. To improve the sensitivity of the temperature sensor, the sensor's working incident light exterior angle α should be chosen under a certain TE mode with the reflectivity to be zero. This temperature sensor is characterized by high sensitivity and simple structure and it is easily fabricated.展开更多
To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and buil...To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.展开更多
The thermal conduction behavior of the three-dimensional axisymmetric functionally graded circular plate was studied under thermal loads on its top and bottom surfaces. Material properties were taken to be arbitrary d...The thermal conduction behavior of the three-dimensional axisymmetric functionally graded circular plate was studied under thermal loads on its top and bottom surfaces. Material properties were taken to be arbitrary distribution functions of the thickness. A temperature function that satisfies thermal boundary conditions at the edges and the variable separation method were used to reduce equation governing the steady state heat conduction to an ordinary differential equation (ODE) in the thickness coordinate which was solved analytically. Next, resulting variable coefficients ODE due to arbitrary distribution of material properties along thickness coordinate was also solved by the Peano-Baker series. Some numerical examples were given to demonstrate the accuracy, efficiency of the present model, mad to investigate the influence of different distributions of material properties on the temperature field. The numerical results confirm that the influence of different material distributions, gradient indices and thickness of plate to temperature field in plate can not be ignored.展开更多
Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the tra...Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the transferred heat flux could reach 32 W/cm2, the smallest thermal resistance for acetone, methanol and FC-72 were respectively 0.50, 0.57 and 0.40℃/W. While for the square capillary type, the transferred heat flux could reach 26 W/cm2, the equivalent thermal conductivity could reach 3211 W/(m. ℃). There are ranges of optimal transferred power and filling ratio for different working liquid. If the transferred power is constant, changing the heating area and the place has little effects on the performance.展开更多
Forced convective heat transfer in a plate channel filled with metallic spherical particles was investigated experimentally and numerically. The test section, 58 mm×80mm×5mm in size, was heated by a 0.4 mm t...Forced convective heat transfer in a plate channel filled with metallic spherical particles was investigated experimentally and numerically. The test section, 58 mm×80mm×5mm in size, was heated by a 0.4 mm thick plate electrical heater. The coolant water now rate ranged from 0.015 to 0.833 kg/s.The local wall temperature distribution was measured along with the inlet and outlet fluid temperatures and pressures. The results illustrate the heat transfer augmentation and increased pressure drop caused by the porous medium. The heat transfer coefficient was increased 5-12 times by the porous media although the hydraulic resistance was increased even more. The Nusselt number and the heat transfer coefficient increased with decreasing particIe diameter, while the pressure drop decreased as the particle diameter increased. It was found that, for the conditions studied (metallic packed bed),the effect of thermal dispersion did not need to be considered in the physical model, as opposed to a non-metallic packed bed, where thermal dispersion is important.展开更多
The heat-transfer behaviour of the conduction cold plate system used for avionics is investigated in this paper. The steady-state temperature profile for the cold plate is derived and the relationship between the cool...The heat-transfer behaviour of the conduction cold plate system used for avionics is investigated in this paper. The steady-state temperature profile for the cold plate is derived and the relationship between the coolant mass flowrate, the heat load and the hashest cold plate temperature is established.A model is proposed to describe the transient thermal rosponse of the cold plate under thermal shock condition. The analytic solution of the transient heat transfer within the cold plate is provided. The results of this paper agree with those of the finite element method and can be used for the structural design and performance evaluation of cold plate system.展开更多
基金The National Natural Science Foundation of China(No.60977038)the Specialized Research Fund for the Doctoral Program of Higher Education(No.20110092110016)+1 种基金the National Basic Research Program of China(973Program)(No.2011CB302004)the Foundation of Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology of Ministry of Education of China(No.201204)
文摘Based on attenuated total reflection (ATR) and thermo-optic effect, the polymeric thin film planar optical waveguide is used as the temperature sensor, and the factors influencing the sensitivity of the temperature sensor are comprehensively analyzed. Combined with theoretical analysis and experimental investigation, the sensitivity of the temperature sensor is related to the thicknesses of the upper cladding layer, the waveguide layer, the optical loss of the polymer material and the guided wave modes. The results show that the slope value about reflectivity and temperature, which stands for the sensitivity of the polymer thin film temperature sensor, is associated with the waveguide film thickness and the guided wave modes, and the slope value is the highest in the zero reflectance of a certain transverse electric (TE) mode. To improve the sensitivity of the temperature sensor, the sensor's working incident light exterior angle α should be chosen under a certain TE mode with the reflectivity to be zero. This temperature sensor is characterized by high sensitivity and simple structure and it is easily fabricated.
文摘To evaluate the thermal performance of a low-temperature electrical radiant floor heating system,an experimental facility equipped with a constant temperature chamber and different specimen floors is designed and built.The heating cable is installed in the floor slab with a unit-rated power of 30 W/m.Twenty-four different schemes are worked out and tested,which include three kinds of composite floor structures and eight kinds of cable distances.The cable distances are 30,40,50,60,80,100,130,150 mm.The main affective factors of the thermal performance and their influencing regularity are discussed.The experimental results show that the system has good stability and reliability,and the ratio of the radiation heat-transfer rate to the gross heat-transfer rate is greater than 50%.When the floor structure and the cable distance are fixed,the gross heat-transfer rate of the upper floor surface has a maximum value at an optimal cable distance.Under the experimental conditions in this paper,the optimal cable distance is 50 mm.
基金Project(11102136)supported by the National Natural Science Foundation of ChinaProject(2012ZDK04)supported by the Open Project of Guangxi Key Laboratory of Disaster Prevention and Structural Safety,China
文摘The thermal conduction behavior of the three-dimensional axisymmetric functionally graded circular plate was studied under thermal loads on its top and bottom surfaces. Material properties were taken to be arbitrary distribution functions of the thickness. A temperature function that satisfies thermal boundary conditions at the edges and the variable separation method were used to reduce equation governing the steady state heat conduction to an ordinary differential equation (ODE) in the thickness coordinate which was solved analytically. Next, resulting variable coefficients ODE due to arbitrary distribution of material properties along thickness coordinate was also solved by the Peano-Baker series. Some numerical examples were given to demonstrate the accuracy, efficiency of the present model, mad to investigate the influence of different distributions of material properties on the temperature field. The numerical results confirm that the influence of different material distributions, gradient indices and thickness of plate to temperature field in plate can not be ignored.
文摘Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the transferred heat flux could reach 32 W/cm2, the smallest thermal resistance for acetone, methanol and FC-72 were respectively 0.50, 0.57 and 0.40℃/W. While for the square capillary type, the transferred heat flux could reach 26 W/cm2, the equivalent thermal conductivity could reach 3211 W/(m. ℃). There are ranges of optimal transferred power and filling ratio for different working liquid. If the transferred power is constant, changing the heating area and the place has little effects on the performance.
文摘Forced convective heat transfer in a plate channel filled with metallic spherical particles was investigated experimentally and numerically. The test section, 58 mm×80mm×5mm in size, was heated by a 0.4 mm thick plate electrical heater. The coolant water now rate ranged from 0.015 to 0.833 kg/s.The local wall temperature distribution was measured along with the inlet and outlet fluid temperatures and pressures. The results illustrate the heat transfer augmentation and increased pressure drop caused by the porous medium. The heat transfer coefficient was increased 5-12 times by the porous media although the hydraulic resistance was increased even more. The Nusselt number and the heat transfer coefficient increased with decreasing particIe diameter, while the pressure drop decreased as the particle diameter increased. It was found that, for the conditions studied (metallic packed bed),the effect of thermal dispersion did not need to be considered in the physical model, as opposed to a non-metallic packed bed, where thermal dispersion is important.
文摘The heat-transfer behaviour of the conduction cold plate system used for avionics is investigated in this paper. The steady-state temperature profile for the cold plate is derived and the relationship between the coolant mass flowrate, the heat load and the hashest cold plate temperature is established.A model is proposed to describe the transient thermal rosponse of the cold plate under thermal shock condition. The analytic solution of the transient heat transfer within the cold plate is provided. The results of this paper agree with those of the finite element method and can be used for the structural design and performance evaluation of cold plate system.