期刊文献+
共找到21篇文章
< 1 2 >
每页显示 20 50 100
AMD跨越“技术断层”
1
作者 汤铭 《信息系统工程》 2002年第10期39-39,共1页
关键词 AMD公司 “技术断层” 信息技术 客户权益倡议计划
下载PDF
Development of advanced electron tomography in materials science based on TEM and STEM 被引量:5
2
作者 李茂华 杨延清 +4 位作者 黄斌 罗贤 张伟 韩明 汝继刚 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2014年第10期3031-3050,共20页
The recent developments of electron tomography(ET) based on transmission electron microscopy(TEM) and scanning transmission electron microscopy(STEM) in the field of materials science were introduced. The variou... The recent developments of electron tomography(ET) based on transmission electron microscopy(TEM) and scanning transmission electron microscopy(STEM) in the field of materials science were introduced. The various types of ET based on TEM as well as STEM were described in detail, which included bright-field(BF)-TEM tomography, dark-field(DF)-TEM tomography, weak-beam dark-field(WBDF)-TEM tomography, annular dark-field(ADF)-TEM tomography, energy-filtered transmission electron microscopy(EFTEM) tomography, high-angle annular dark-field(HAADF)-STEM tomography, ADF-STEM tomography, incoherent bright field(IBF)-STEM tomography, electron energy loss spectroscopy(EELS)-STEM tomography and X-ray energy dispersive spectrometry(XEDS)-STEM tomography, and so on. The optimized tilt series such as dual-axis tilt tomography, on-axis tilt tomography, conical tilt tomography and equally-sloped tomography(EST) were reported. The advanced reconstruction algorithms, such as discrete algebraic reconstruction technique(DART), compressed sensing(CS) algorithm and EST were overviewed. At last, the development tendency of ET in materials science was presented. 展开更多
关键词 electron tomography materials science transmission electron microscopy scanning transmission electron microscopy
下载PDF
Application of SAGE algorithm in PET image reconstruction using modified ordered subsets 被引量:1
3
作者 朱宏擎 舒华忠 +1 位作者 周健 罗立民 《Journal of Southeast University(English Edition)》 EI CAS 2005年第3期319-323,共5页
A new method that uses a modified ordered subsets (MOS) algorithm to improve the convergence rate of space-alternating generalized expectation-maximization (SAGE) algorithm for positron emission tomography (PET)... A new method that uses a modified ordered subsets (MOS) algorithm to improve the convergence rate of space-alternating generalized expectation-maximization (SAGE) algorithm for positron emission tomography (PET) image reconstruction is proposed.In the MOS-SAGE algorithm,the number of projections and the access order of the subsets are modified in order to improve the quality of the reconstructed images and accelerate the convergence speed.The number of projections in a subset increases as follows:2,4,8,16,32 and 64.This sequence means that the high frequency component is recovered first and the low frequency component is recovered in the succeeding iteration steps.In addition,the neighboring subsets are separated as much as possible so that the correlation of projections can be decreased and the convergences can be speeded up.The application of the proposed method to simulated and real images shows that the MOS-SAGE algorithm has better performance than the SAGE algorithm and the OSEM algorithm in convergence and image quality. 展开更多
关键词 positron emission tomography space-alternating generalized expectation-maximization: imagereconstruction modified ordered subsets
下载PDF
Effects of seasonal water-level fluctuation on soil pore structure in the Three Gorges Reservoir,China 被引量:9
4
作者 ZHANG Shu-juan TANG Qiang +5 位作者 BAO Yu-hai HE Xiu-bin TIAN Feng-xia LüFa-you WANG Ming-feng Raheel ANJUM 《Journal of Mountain Science》 SCIE CSCD 2018年第10期2192-2206,共15页
Inundation of the Three Gorges Reservoir has created a 30-m water-level fluctuation zone with seasonal hydrological alternations of submergence and exposure, which may greatly affect soil properties and bank stability... Inundation of the Three Gorges Reservoir has created a 30-m water-level fluctuation zone with seasonal hydrological alternations of submergence and exposure, which may greatly affect soil properties and bank stability. The aim of this study was to investigate the response of soil pore structure to seasonal water-level fluctuation in the reservoir, and particularly, the hydrological change of wetting and drying cycles. Soil pore structure was visualized with industrial X-ray computed tomography and digital image analysis techniques. The results showed that soil total porosity(? 100 ?m), total pore number, total throat number, and mean throat surface area increased significantly under wetting and drying cycles. Soil porosity, pore number and throat numberwithin each size class increased in the course of wetting and drying cycles. The coordination number, degree of anisotropy and fractal dimension were indicating an increase. In contrast, the mean shape factor, pore-throat ratio, and Euler-Poincaré number decreased due to wetting and drying cycles. These illustrated that the wetting and drying cycles made soil pore structure become more porous, continuous, heterogeneous and complex. It can thus be deduced that the water-level fluctuation would modify soil porosity, pore size distribution, and pore morphology in the Three Gorges Reservoir, which may have profound implications for soil processes, soil functions, and bank stability. 展开更多
关键词 Soil pore structure X-ray computed tomography Image analysis Wetting and drying cycles Water-level fluctuation Three Gorges
下载PDF
Imaging technologies in oilfield applications 被引量:2
5
作者 XIE C.G. NORTH R. +3 位作者 WILT M. ZHANG P. DENACLARA H. LEVESQUE C. 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1394-1400,共7页
In this paper, we describe some recent imaging technologies developed by Schlumberger for oilfield downhole mul- tiphase flow production logging (PL) and cross-well electromagnetic (EM) survey applications. FloScan Im... In this paper, we describe some recent imaging technologies developed by Schlumberger for oilfield downhole mul- tiphase flow production logging (PL) and cross-well electromagnetic (EM) survey applications. FloScan Imager (FSITM) has been introduced as a 3-phase oil/gas/water flow PL tool for deviated and horizontal wells. FSI sensors can map fluid velocity and holdup profiles along a vertical diameter of the wellbore at every survey depth, enabling a robust estimate of the individual phase flow rates in complex flow regimes. The cross-well EM survey is based on cross-borehole induction logging technique and provides resistivity distribution at a reservoir scale. It is a useful tool for reservoir management and is most effective in dynamic fields where fluid saturations are variable in time and space. The tool can be used to identify (water or steam) flooded and bypassed regions. By monitoring changes in the resistivity spatial distribution with time, cross-well EM survey is very effective at mapping inter-well temperature and structure. Some field examples are shown for both FloScan Imager PL tool and cross-well resistivity imaging survey. 展开更多
关键词 OILFIELD Production logging (PL) Multiphase flow IMAGING TOMOGRAPHY Cross-well resistivity
下载PDF
Small intestine contrast ultrasonography vs computed tomography enteroclysis for assessing ileal Crohn's disease 被引量:5
6
作者 Sara Onali Emma Calabrese +10 位作者 Carmelina Petruzziello Francesca Zorzi Giuseppe Sica Roberto Fiori Marta Ascolani Elisabetta Lolli Giovanna Condino Giampiero Palmieri Giovanni Simonetti Francesco Pallone Livia Biancone 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第42期6088-6095,共8页
AIM:To compare computed tomography enteroclysis(CTE) vs small intestine contrast ultrasonography(SICUS) for assessing small bowel lesions in Crohn's disease(CD),when using surgical pathology as gold standard.METHO... AIM:To compare computed tomography enteroclysis(CTE) vs small intestine contrast ultrasonography(SICUS) for assessing small bowel lesions in Crohn's disease(CD),when using surgical pathology as gold standard.METHODS:From January 2007 to July 2008,15 eligible patients undergoing elective resection of the distal ileum and coecum(or right colon) were prospectively enrolled.All patients were under follow-up.The study population included 6 males and 9 females,with a median age of 44 years(range:18-80 years).Inclusion criteria:(1) certain diagnosis of small bowel requiring elective ileo-colonic resection;(2) age between 18-80 years;(3) elective surgery in our Surgical Unit;and(4) written informed consent.SICUS and CTE were performed ≤ 3 mo before surgery,followed by surgical pathology.The following small bowel lesions were blindly reported by one sonologist,radiologist,surgeon and histolopathologist:disease site,extent,strictures,abscesses,fistulae,small bowel dilation.Comparison between findings at SICUS,CTE,surgical specimens and histological examination was made by assessing the specificity,sensitivity and accuracy of each technique,when using surgical findings as gold standard.RESULTS:Among the 15 patients enrolled,CTE was not feasible in 2 patients,due to urgent surgery in one patients and to low compliance in the second patient,refusing to perform CTE due to the discomfort related to the naso-jejunal tube.The analysis for comparing CTE vs SICUS findings was therefore performed in 13 out of the 15 CD patients enrolled.Differently from CTE,SICUS was feasible in all the 15 patients enrolled.No complications were observed when using SICUS or CTE.Surgical pathology findings in the tested population included:small bowel stricture in 13 patients,small bowel dilation above ileal stricture in 10 patients,abdominal abscesses in 2 patients,enteric fistulae in 5 patients,lymphnodes enlargement(> 1 cm) in 7 patients and mesenteric enlargement in 9 patients.In order to compare findings by using SICUS,CTE,histology and surgery,characteristics of the small bowel lesions observed in CD each patient were blindly reported in the same form by one gastroenterologistsonologist,radiologist,surgeon and anatomopathologist.At surgery,lesions related to CD were detected in the distal ileum in all 13 patients,also visualized by both SICUS and CTE in all 13 patients.Ileal lesions > 10 cm length were detected at surgery in all the 13 CD patients,confirmed by SICUS and CTE in the same 12 out of the 13 patients.When using surgical findings as a gold standard,SICUS and CTE showed the exactly same sensitivity,specificity and accuracy for detecting the presence of small bowel fistulae(accuracy 77% for both) and abscesses(accuracy 85% for both).In the tested CD population,SICUS and CTE were also quite comparable in terms of accuracy for detecting the presence of small bowel strictures(92% vs 100%),small bowel fistulae(77% for both) and small bowel dilation(85% vs 82%).CONCLUSION:In our study population,CTE and the non-invasive and radiation-free SICUS showed a comparable high accuracy for assessing small bowel lesions in CD. 展开更多
关键词 Crohn's disease Ileal lesions Computed tomography enteroclysis Small intestine contrast ultrasonography Surgical findings
下载PDF
Imaging of liver cancer 被引量:5
7
作者 Ben Ariff Claire R Lloyd +6 位作者 Sameer Khan Mohamed Shariff Andrew V Thillainayagam Devinder S Bansi Shahid A Khan Simon D Taylor-Robinson Adrian KP Lim 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第11期1289-1300,共12页
Improvements in imaging technology allow exploitation of the dual blood supply of the liver to aid in the identif ication and characterisation of both malignant and benign liver lesions. Imaging techniques available i... Improvements in imaging technology allow exploitation of the dual blood supply of the liver to aid in the identif ication and characterisation of both malignant and benign liver lesions. Imaging techniques available include contrast enhanced ultrasound, computed tomography and magnetic resonance imaging. This review discusses the application of several imaging techniques in the diagnosis and staging of both hepatocellular carcinoma and cholangiocarcinoma and outlines certain characteristics of benign liver lesions. The advantages of each imaging technique are highlighted, while underscoring the potential pitfalls and limitations of each imaging modality. 展开更多
关键词 Hepatic cell carcinoma CHOLANGIOCARCINOMA Contrast enhanced ultrasound Computed tomography Magnetic resonance imaging
下载PDF
THEORETICAL ANALYSIS OF THE STABILITY OF A DEEP ROADWAY 被引量:1
8
作者 付国彬 《Journal of China University of Mining and Technology》 1995年第1期58-65,共8页
In this paper the thickness of a broken zone, a state parameter of roadway surrounding rock, is used as the index to evaluate the stabi1ity of surrounding rock of a deep roadway. The paper gives a theoretic formula fo... In this paper the thickness of a broken zone, a state parameter of roadway surrounding rock, is used as the index to evaluate the stabi1ity of surrounding rock of a deep roadway. The paper gives a theoretic formula for calculating the thickness of the broken zone. The author points out that not only the ultimate strength of rockmass but its residual strength and strain-softening level all have a great influence on the stability of surrounding rock of a deep roadway. The paper’s results show that to reinforce surrounding rock, raise its residual strength and lower its strain-softening level should be taken as a basic requirement for supports of a deep roadway. In addition, the research also indicates that it is impossible for roadway supports to change surrounding rock states of a deep roadway, so it is certain for them to work in a broken state. For this reason, a sufficient yieldable quantity is necessary for roadway supports used in deep mining. 展开更多
关键词 deep mining roadway stability broken-zone thickness
下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
9
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
下载PDF
Diagnostics in inflammatory bowel disease: Ultrasound 被引量:20
10
作者 Deike Strobel Ruediger S Goertz Thomas Bernatik 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第27期3192-3197,共6页
Diagnosis of chronic inflammatory bowel diseases (IBD) is based on a combination of clinical symptoms, laboratory tests and imaging data. Imaging of the morphological characteristics of IBD includes the assessment of ... Diagnosis of chronic inflammatory bowel diseases (IBD) is based on a combination of clinical symptoms, laboratory tests and imaging data. Imaging of the morphological characteristics of IBD includes the assessment of mucosal alterations, transmural involvement and extraintestinal manifestations. No single imaging technique serves as a diagnostic gold standard to encompass all disease manifestations. Ultrasound, computed tomography (CT) or magnetic resonance imaging (MRI) allow cross-sectional imaging of the transmural alterations and extraintestinal manifestations. While in the USA the technique of choice is CT, in Europe the focus is more on MRI and ultrasound (US). Most patients with chronic IBD are diagnosed at a young age. After baseline diagnosis many of these young patients have to undergo repetitive imaging procedures during the variable clinical course of the disease, characterized by alternate periods of remission and active disease, and in monitoring the response to treatment. US has the advantage of being noninvasive, less costly, and easily repeatable, and thus can be very useful in following up patients with IBD. In addition, rising concern about radiation exposure in young adults indicates the demand for radiation-sparing techniques like US and MRI. This article focuses on the current clinical practice of US in IBD, describing the current technologies used in transabdominal intestinal US and the characteristic sonographic findings in Crohn′s disease and ulcerative colitis. 展开更多
关键词 High-frequency waves ULTRASOUND Clinical practice Inflammatory bowel disease Color Doppler Contrast agents
下载PDF
Use of 3-D magnetic resonance electrical impedance tomography in detecting human cerebral stroke: a simulation study 被引量:2
11
作者 高诺 朱善安 贺斌 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE EI CAS CSCD 2005年第5期438-445,共8页
We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electri... We have developed a new three dimensional (3-D) conductivity imaging approach and have used it to detect human brain conductivity changes corresponding to acute cerebral stroke. The proposed Magnetic Resonance Electrical Impedance Tomography (MREIT) approach is based on the J-Substitution algorithm and is expanded to imaging 3-D subject conductivity distribution changes. Computer simulation studies have been conducted to evaluate the present MREIT imaging approach. Simulations of both types of cerebral stroke, hemorrhagic stroke and ischemic stroke, were performed on a four-sphere head model. Simulation results showed that the correlation coefficient (CC) and relative error (RE) between target and estimated conductivity distributions were 0.9245±0.0068 and 8.9997%±0.0084%, for hemorrhagic stroke, and 0.6748±0.0197 and 8.8986%±0.0089%, for ischemic stroke, when the SNR (signal-to-noise radio) of added GWN (Gaussian White Noise) was 40. The convergence characteristic was also evaluated according to the changes of CC and RE with different iteration numbers. The CC increases and RE decreases monotonously with the increasing number of iterations. The present simulation results show the feasibility of the proposed 3-D MREIT approach in hemorrhagic and ischemic stroke detection and suggest that the method may become a useful alternative in clinical diagnosis of acute cerebral stroke in humans. 展开更多
关键词 Magnetic Resonance Electrical Impedance Tomography CONDUCTIVITY Acute cerebral stroke Hemorrhagic stroke Ischemic stroke Current density imaging
下载PDF
Computed Tomography Using Level Set Method and Algebraic Reconstruction Technique
12
作者 薛倩 王化祥 《Transactions of Tianjin University》 EI CAS 2011年第6期418-423,共6页
In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction me... In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction method is inserted into the conventional iteration procedure of algebraic reconstruction technique to improve the image quality and convergence speed with limited projection data. By evolving the image as a set of iso-intensity contours after each updation, the sufficient number of iterations for acceptable results is reduced by 80%-90%, while the image quality is enhanced obviously. Quantitative evaluation of image quality is given by using both relative image error and correlation coefficient. The resultant images can be utilized to detect flow regimes for monitoring industrial multiphase flow. Laboratory results demonstrate the feasibility of the proposed method. Phantoms of four typical flow regimes can be reconstructed from few-view projection data efficiently, and the corresponding image errors and correlation coefficients are acceptable for the cases tested in this paper. 展开更多
关键词 computed tomography multiphase flow image reconstruction
下载PDF
The Acquisition Technique of High-resolution Seismic Data for the Prospecting of Active Faults
13
作者 Zhao Chengbin Liu Baojin Ji Jifa 《Earthquake Research in China》 2011年第3期320-329,共10页
The high-resolution shallow seismic technique can be used for more accurately prospecting the position and property of faults and for the preliminary study of fault activity.The author obtains many high quality stack ... The high-resolution shallow seismic technique can be used for more accurately prospecting the position and property of faults and for the preliminary study of fault activity.The author obtains many high quality stack time sections through the prospecting methods of different seismic sources,different group intervals and different observation systems on the Xiadian fault.These sections clearly display the stratum structure and the structure characteristics from several meters to several hundred meters of the Xiadian fault.The resolutions of the different seismic sources,different group intervals and different observing systems are obtained.The prospecting methods and work parameters applicable for goal stratum of different depths and different accuracy requirements are proposed through the analysis of the stack time sections.This lays a good foundation for raising the prospecting resolution of the fault position and the latest active time of the fault. 展开更多
关键词 Active fault HIGH-RESOLUTION Longitudinal wave and transverse wave Controlled seismic source Time section
下载PDF
Ultrasonic tomography and its applications in oilfield
14
作者 钟兴福 吴应湘 +2 位作者 李东晖 李强 王兴国 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2005年第12期1420-1423,共4页
UTT (Ultrasonic Tomography Tool) is widely used in the oil industry and can be used to inspect corrosion, casing wall damage, casing breakoff, and casing distortion in the well borehole with the maximum environment ... UTT (Ultrasonic Tomography Tool) is widely used in the oil industry and can be used to inspect corrosion, casing wall damage, casing breakoff, and casing distortion in the well borehole with the maximum environment temperature being 125 ℃, and the pressure being 60 MPa. UTT consists of tool head, upper centralization, electronic section, lower centralization, transmitters, and receivers. Its outer diameter is 4.6 cm and length is 320 cm. The measured casing diameter ranges from 60 mm to 254 mm. The tomography resolution is 512×512. The borehole measurement accuracy is 2 mm. It can supply 3D pipe tomography, including horizontal and vertical profile. This paper introduces its specification, measurement principle, and applications in oilfield. 展开更多
关键词 Ultrasonic tomography Downhole tool Casing hole
下载PDF
Microencapsulated tumor assay:Evaluation of the nude mouse model of pancreatic cancer 被引量:1
15
作者 Ming-Zhe Ma Dong-Feng Cheng +5 位作者 Jin-Hua Ye Yong Zhou Jia-Xiang Wang Min-Min Shi Bao-San Han Cheng-Hong Peng 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第3期257-267,共11页
AIM: To establish a more stable and accurate nude mouse model of pancreatic cancer using cancer cell microencapsulation. METHODS: The assay is based on microencapsulation technology, wherein human tumor cells are enca... AIM: To establish a more stable and accurate nude mouse model of pancreatic cancer using cancer cell microencapsulation. METHODS: The assay is based on microencapsulation technology, wherein human tumor cells are encapsulated in small microcapsules (approximately 420 μm in diameter) constructed of semipermeable membranes. We implemented two kinds of subcutaneous implantation models in nude mice using the injection of single tumor cells and encapsulated pancreatic tumor cells. The size of subcutaneously implanted tumors was observed ona weekly basis using two methods, and growth curves were generated from these data. The growth and metastasis of orthotopically injected single tumor cells and encapsulated pancreatic tumor cells were evaluated at four and eight weeks postimplantation by positron emission tomography-computed tomography scan and necropsy. The pancreatic tumor samples obtained from each method were then sent for pathological examination. We evaluated differences in the rates of tumor incidence and the presence of metastasis and variations in tumor volume and tumor weight in the cancer microcapsules vs single-cell suspensions. RESULTS: Sequential in vitro observations of the microcapsules showed that the cancer cells in microcapsules proliferated well and formed spheroids at days 4 to 6. Further in vitro culture resulted in bursting of the membrane of the microcapsules and cells deviated outward and continued to grow in flasks. The optimum injection time was found to be 5 d after tumor encapsulation. In the subcutaneous implantation model, there were no significant differences in terms of tumor volume between the encapsulated pancreatic tumor cells and cells alone and rate of tumor incidence. There was a significant difference in the rate of successful im- plantation between the cancer cell microencapsulation group and the single tumor-cell suspension group (100% vs 71.43%, respectively, P = 0.0489) in the orthotropic implantation model. The former method displayed an obvious advantage in tumor mass (4th wk: 0.0461 ± 0.0399 vs 0.0313 ± 0.021, t = -0.81, P = 0.4379; 8th wk: 0.1284 ± 0.0284 vs 0.0943 ± 0.0571, t = -2.28, respectively, P = 0.0457) compared with the latter in the orthotopic implantation model. CONCLUSION: Encapsulation of pancreatic tumor cells is a reliable method for establishing a pancreatic tumor animal model. 展开更多
关键词 Nude mice Model of pancreatic neoplasms Encapsulation Subcutaneous implantation model Ortho- topic implantation model
下载PDF
A Quantitative Analysis of Dose Distributions of Two Tangential Whole Breast Irradiation Techniques
16
作者 Tamara Jovanovic Jelena Stankovic +1 位作者 Dragan Nikolic Jelica Jovev 《Journal of Physical Science and Application》 2016年第5期27-30,共4页
We compared DVHs (dose volume histograms) of two tangential irradiation techniques for whole breast RT (radiotherapy) CT (computed tomography) based 2D (two dimensional) technique with wedge filters and 3D CRT... We compared DVHs (dose volume histograms) of two tangential irradiation techniques for whole breast RT (radiotherapy) CT (computed tomography) based 2D (two dimensional) technique with wedge filters and 3D CRT (three dimensional conformal radiotherapy) with segmented fields. These two modalities are commonly used in external beam radiotherapy of breast cancer in Clinical Center Nis, Clinic of Oncology, Serbia. Therapy plans that employed two techniques were generated for eighteen patients. Dosimetric outcomes of each technique were investigated. The maximum dose of breast CTV was significantly reduced from 55.83 Gy for 2D to 54.1 Gy for 3D CRT. Also, the maximum dose of lung tissue decreased from 51.81 Gy for 2D to 49.61 Gy for 3D. The dose conformity and uniformity were much better with 3D CRT segmented field technique. 展开更多
关键词 Breast cancer conformal technique virtual simulation tangential fields segmented fields.
下载PDF
Dual-basis reconstruction techniques for tomographic PIV 被引量:4
17
作者 YE ZhiJian GAO Qi +2 位作者 WANG HongPing WEI RunJie WANG JinJun 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2015年第11期1963-1970,共8页
As an inverse problem, particle reconstruction in tomographic particle image velocimetry attempts to solve a large-scale underdetermined linear system using an optimization technique. The most popular approach, the mu... As an inverse problem, particle reconstruction in tomographic particle image velocimetry attempts to solve a large-scale underdetermined linear system using an optimization technique. The most popular approach, the multiplicative algebraic reconstruction technique(MART), uses entropy as an objective function in the optimization. All available MART-based methods are focused on improving the efficiency and accuracy of particle reconstruction. However, those methods do not perform very well on dealing with ghost particles in highly seeded measurements. In this report, a new technique called dual-basis pursuit(DBP), which is based on the basis pursuit technique, is proposed for tomographic particle reconstruction. A template basis is introduced as a priori knowledge of a particle intensity distribution combined with a correcting basis to enable a full span of the solution space of the underdetermined linear system. A numerical assessment test with 2D synthetic images indicated that the DBP technique is superior to MART method, can completely recover a particle field when the number of particles per pixel(ppp) is less than 0.15, and can maintain a quality factor Q of above 0.8 for ppp up to 0.30. Unfortunately, the DBP method is difficult to utilize in 3D applications due to the cost of its excessive memory usage. Therefore, a dual-basis MART was designed that performed better than the traditional MART and can potentially be utilized for 3D applications. 展开更多
关键词 tomographic PIV particle reconstruction dual-basis pursuit multiplicative algebraic reconstruction technique
原文传递
Assessment of cortical bone microdamage following insertion of microimplants using optical coherence tomography: a preliminary study 被引量:2
18
作者 Hemanth Tumkur LAKSHMIKANTHA Naresh Kumar RAVICHANDRAN +2 位作者 Mansik JEON Jeehyun KIM Hyo-sang PARK 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2018年第11期818-828,共11页
Objectives: The study was done to evaluate the efficacy of optical coherence tomography (OCT), to detect and analyze the microdamage occurring around the microimplant immediately following its placement, and to com... Objectives: The study was done to evaluate the efficacy of optical coherence tomography (OCT), to detect and analyze the microdamage occurring around the microimplant immediately following its placement, and to compare the findings with micro-computed tomography (IJCT) images of the samples to validate the result of the present study. Methods: Microimplants were inserted into bovine bone samples. Images of the samples were obtained using OCT and μCT. Visual comparisons of the images were made to evaluate whether anatomical details and microdamage induced by microimplant insertion were accurately revealed by OCT. Results: The surface of the cortical bone with its anatomical variations is visualized on the OCT images. Microdamage occurring on the surface of the cortical bone around the microimplant can be appreciated in OCT images. The resulting OCT images were compared with the μCT images. A high correlation regarding the visualization of individual microcracks was observed. The depth penetration of OCT is limited when compared to μCT. Conclusions: OCT in the present study was able to generate high-resolution images of the microdamage occurring around the microimplant. Image quality at the surface of the cortical bone is above par when compared with μCT imaging, because of the inherent high contrast and high-resolution quality of OCT systems. Improvements in the imaging depth and development of intraoral sensors are vital for developing a real-time imaging system and integrating the system into orthodontic practice. 展开更多
关键词 Optical coherence tomography Microimplant Cortical bone Micro-computed tomography
原文传递
Assessments of tear meniscus height, tear film thickness, and corneal epithelial thickness after deep anterior lamellar keratoplasty 被引量:2
19
作者 Wen-jia XIE Ye-sheng XU +1 位作者 Xia ZHANG Yu-feng YAO 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2018年第3期218-226,共9页
Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was... Objective: To assess the lower tear meniscus height(LTMH), central tear film thickness(CTFT), and central corneal epithelial thickness(CCET) after deep anterior lamellar keratoplasty(DALK). Methods: This was a retrospective cross-sectional study of 20 patients who had DALK in one eye over a three-month period. LTMH, CTFT, and CCET of the operated eyes and the unoperated fellow eyes were measured using high-definition optical coherence tomography(HD-OCT). Correlations between three OCT assessments and age, time following surgery, graft size, bed size, and the number of residual sutures were analyzed. Results: Compared to patients with keratoconus, patients with other corneal conditions had significantly higher CCET in the fellow eye(P=0.024). For all patients, CCET in the operated eye was significantly negatively correlated with the number of residual sutures(R=-0.579, P=0.008), and was significantly positively correlated with time following surgery(R=0.636, P=0.003). In the fellow eye, a significant positive correlation was found between age and CCET(R=0.551, P=0.012), and a significant negative correlation between age and CTFT(R=-0.491, P=0.028). LTMH was found to be significantly correlated between operated and fellow eyes(R=0.554, P=0.011). There was no significant correlation between LTMH and age, bed/graft size, time following surgery, or residual sutures(all possible correlations, P0.05). Conclusions: Patients with keratoconus tend to have a thinner central corneal epithelium. Corneal epithelium keeps regenerating over time after DALK. DALK did not induce a significant change in tear volume compared with the fellow eye. Postoperative tear function might depend on an individual's general condition, rather than on age, gender, bed/graft size, time following surgery, or residual sutures. 展开更多
关键词 Tear meniscus height Corneal epithelial thickness Tear film Deep anterior lamellar keratoplasty (DALK) High-definition optical coherence tomography (HD-OCT) KERATOCONUS
原文传递
Diagnostic value of optic disc retinal nerve fiber layer thickness for diabetic peripheral neuropathy
20
作者 Xiao-hong WU Jing-wen FANG +4 位作者 Yin-qiong HUANG Xue-feng BAI Yong ZHUANG Xiao-yu CHEN Xia-hong LIN 《Journal of Zhejiang University-Science B(Biomedicine & Biotechnology)》 SCIE CAS CSCD 2020年第11期911-920,共10页
Objective:To investigate the value of optic disc retinal nerve fiber layer(RNFL)thickness in the diagnosis of diabetic peripheral neuropathy(DPN).Methods:Ninety patients with type 2 diabetes,including 60 patients with... Objective:To investigate the value of optic disc retinal nerve fiber layer(RNFL)thickness in the diagnosis of diabetic peripheral neuropathy(DPN).Methods:Ninety patients with type 2 diabetes,including 60 patients without DPN(NDPN group)and 30 patients with DPN(DPN group),and 30 healthy participants(normal group)were enrolled.Optical coherence tomography(OCT)was used to measure the four quadrants and the overall average RNFL thickness of the optic disc.The receiver operator characteristic curve was drawn and the area under the curve(AUC)was calculated to evaluate the diagnostic value of RNFL thickness in the optic disc area for DPN.Results:The RNFL thickness of the DPN group was thinner than those of the normal and NDPN groups in the overall average((101.07±12.40)μm vs.(111.07±6.99)μm and(109.25±6.90)μm),superior quadrant((123.00±19.04)μm vs.(138.93±14.16)μm and(134.47±14.34)μm),and inferior quadrant((129.37±17.50)μm vs.(143.60±12.22)μm and(144.48±14.10)μm),and the differences were statistically significant.The diagnostic efficiencies of the overall average,superior quadrant,and inferior quadrant RNFL thicknesses,and a combined index of superior and inferior quadrant RNFL thicknesses were similar,and the AUCs were 0.739(95%confidence interval(CI)0.635–0.826),0.683(95%CI 0.576–0.778),0.755(95%CI 0.652–0.840),and 0.773(95%CI 0.672–0.854),respectively.The diagnostic sensitivity of RNFL thickness in the superior quadrant reached 93.33%.Conclusions:The thickness of the RNFL in the optic disc can be used as a diagnostic method for DPN. 展开更多
关键词 Type 2 diabetes Peripheral neuropathy Retinal nerve fiber layer thickness Optical coherence tomography DIAGNOSIS
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部