The passive anti-rolling tank is one of important ship stabilizers widely used today. But at present, research of the tank is most aimed at its rolling movement. In this paper, the influence of sway motion on the pass...The passive anti-rolling tank is one of important ship stabilizers widely used today. But at present, research of the tank is most aimed at its rolling movement. In this paper, the influence of sway motion on the passive anti-rolling tank is considered, the mathematical model of "ship-passive antl-rolling tank" system coupled with sway motion is developed basing on the U-shaped passive anti-rolling tank theory. Both simulation results and experimental data indicate that it is necessary to consider the influence of sway motion on the anti-rolling tank, which is more agreeable to the actual circumstance.展开更多
An experimental study was carried out in a small-scale furnace to investigate the performance, such as NOx emission, enhancement of heat transfer, uniformity of temperature, and etc., of oscillating combustion applied...An experimental study was carried out in a small-scale furnace to investigate the performance, such as NOx emission, enhancement of heat transfer, uniformity of temperature, and etc., of oscillating combustion applied in radiant tube burner sy stem for heat treatment furnace. A premixed type burner and a solenoid type oscillating control valve were designed and used. The fuel was used commercial LPG in this study and the fuel flow was oscillated by periodically opening and shutoff of the solenoid valve. From the tests, it was found that NOx emission, compared to no oscillation, could be reduced by 32% at 2.0 Hz. However, as oscillating frequency was increased, abatement of NOx emission was gradually reduced. At the high NOx abatement of 1.0 Hz, carbon monoxide was emitted above 10,000 ppm. Although rate of NOx abatement was low, oscillation condition of 2.5 Hz and duty ratio of 10-30% was recommended for low carbon monoxide emission. From the measurement of furnace heating time from 100 ℃ to 720 ℃, it was shown that heat transfer was increased by 11.5% at 2 Hz oscillating frequency. Temperature distribution of radiant tube surface was more uniform at 2 Hz oscillating frequency with drop of the peak temperature and rise of low temperature. From these results, it was confirmed that oscillating combustion was useful in radiant tube burner system.展开更多
文摘The passive anti-rolling tank is one of important ship stabilizers widely used today. But at present, research of the tank is most aimed at its rolling movement. In this paper, the influence of sway motion on the passive anti-rolling tank is considered, the mathematical model of "ship-passive antl-rolling tank" system coupled with sway motion is developed basing on the U-shaped passive anti-rolling tank theory. Both simulation results and experimental data indicate that it is necessary to consider the influence of sway motion on the anti-rolling tank, which is more agreeable to the actual circumstance.
文摘An experimental study was carried out in a small-scale furnace to investigate the performance, such as NOx emission, enhancement of heat transfer, uniformity of temperature, and etc., of oscillating combustion applied in radiant tube burner sy stem for heat treatment furnace. A premixed type burner and a solenoid type oscillating control valve were designed and used. The fuel was used commercial LPG in this study and the fuel flow was oscillated by periodically opening and shutoff of the solenoid valve. From the tests, it was found that NOx emission, compared to no oscillation, could be reduced by 32% at 2.0 Hz. However, as oscillating frequency was increased, abatement of NOx emission was gradually reduced. At the high NOx abatement of 1.0 Hz, carbon monoxide was emitted above 10,000 ppm. Although rate of NOx abatement was low, oscillation condition of 2.5 Hz and duty ratio of 10-30% was recommended for low carbon monoxide emission. From the measurement of furnace heating time from 100 ℃ to 720 ℃, it was shown that heat transfer was increased by 11.5% at 2 Hz oscillating frequency. Temperature distribution of radiant tube surface was more uniform at 2 Hz oscillating frequency with drop of the peak temperature and rise of low temperature. From these results, it was confirmed that oscillating combustion was useful in radiant tube burner system.