期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
试谈读后感“最佳角度”的选取
1
作者 彭承平 《学语文》 2005年第5期54-55,共2页
求新,作文的生命。怎样求新?关键在于打破常规思维,选好切入角度。读后感的写作也是如此。同一文章的读后感的写作可以从多个角度入手,这是由于:1.读后感本身的形式和内容是多种多样的;2.原文本的思想艺术内涵是丰富的;3.不... 求新,作文的生命。怎样求新?关键在于打破常规思维,选好切入角度。读后感的写作也是如此。同一文章的读后感的写作可以从多个角度入手,这是由于:1.读后感本身的形式和内容是多种多样的;2.原文本的思想艺术内涵是丰富的;3.不同的人对同一问题的感受是千差万别的。在一篇读后感当中,不必要也不可能将种种感受都表达出来。因此,最佳角度的选取就显得尤为重要。 展开更多
关键词 读后感 “最佳角度” 语文 中学 写作指导
下载PDF
Realization of Super Large Autostereoscopic Display Wall
2
作者 田丰 杨雪 +1 位作者 仇润鹤 刘锦高 《Journal of Donghua University(English Edition)》 EI CAS 2011年第1期104-108,共5页
The suitable lenticular lens for large panel autostereoscopic display was designed,and its optical transmission property was analyzed.The location of the best viewing zones and the relationship between screen size and... The suitable lenticular lens for large panel autostereoscopic display was designed,and its optical transmission property was analyzed.The location of the best viewing zones and the relationship between screen size and the optimum viewing distance were proposed.On the basis of the original monitor,rear projection screen material suitable for large panel three-dimensional(3D) monitor and splicing method for 3D display wall were studied.Close to 150-inch-large panel stereo display wall was achieved. 展开更多
关键词 digital light projector(DLP) VIEWPOINT stereo viewing zone viewing angle optimum viewing distance
下载PDF
Experimental study on performance of contra-rotating axial flow fan 被引量:4
3
作者 Shizhai Zhang 《International Journal of Coal Science & Technology》 EI 2015年第3期232-236,共5页
Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow ... Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow fan is experi- mentally investigated. The study is focused on the fan performance, the shaft power and the match between the motor and fan efficiency at different blade angles. The results show that the blade angle 43°/26° has the best aerodynamic perfor- mance. The first engine has a greater impact on the fan than the second one. The blade angle with the best aerodynamic performance does not necessarily correspond to the one with the best match between the motor and fan efficiency. The blade angle 43°/24° is the best choice for the operation of the fan in the present study. 展开更多
关键词 Contra-rotating axial flow fan Fan performance Shaft power Blade angle
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部