The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show t...The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show that the two factors have great effects on the heat flux distribution. The non-uniformity of the local heat-flux on the impinging plate surface gets more profound as the plate becomes thicker and thermal conductivity gets larger. When Reynolds number is 5000, the ratio of nozzle-to-plate spacing to nozzle diameter is 5 and thermal conductivity is 16W/(m·K), and even for the plate with only 25μm in thickness, the non-uniformity of the heat flux cannot be neglected. When the plate thickness is 50 μm, only when thermal conductivity is as small as 1W/(m·K), the heat flux curve can be approximately treated as an iso-heat-flux boundary. In the experimental research, a real non-iso-heat-flux boundary is treated as an iso-heat-flux boundary, which would result in under-estimated Nusselt number value in the stagnation zone and an over-estimated value outside. Such an experimental Nusselt number distribution is taken to evaluate turbulent model, and the conclusion would be drawn that the turbulent model over-predicts the stagnation heat transfer. This is one of the important reasons why many literatures reported that k-ε turbulent model dramatically over-predicts the impinging jet heat transfer in the stagnation region.展开更多
It is only an assumption to simplify the reality that there is no contact force between cracks. In many cases, unilateral crack may be more close to reality, i.e. there is a contact force between cracks. A dynamic exp...It is only an assumption to simplify the reality that there is no contact force between cracks. In many cases, unilateral crack may be more close to reality, i.e. there is a contact force between cracks. A dynamic experimental system was used to measure the contact force in organic glass with cracks. Curves of time versus contact force established through experiments show that the magnitude of contact force relates to the interrelation among external forces, contact points and falling points.展开更多
Based on the reaction microscope at the institute of modern physics, the reaction mechanism in molecular ion-atom collisions is investigated experimentally. The features of this system is illustrated by a kinematicall...Based on the reaction microscope at the institute of modern physics, the reaction mechanism in molecular ion-atom collisions is investigated experimentally. The features of this system is illustrated by a kinematically complete experhnent performed for the collision process. Using the so-called list-mode data recording technique and the coincidence measurement, the momentum vector of each fragment from the molecular ion were recorded event by event. The orientation of the molecular axis for H2^+ dissociation reactions could be determined for each event in the off-line analysis. The measured orientation of the molecular ion is believed the same as the one at the instance of collision under axial recoil approximation. The polar angle resolution of the molecular orientation of ±8° was obtained.展开更多
基金Project(50376076) supported by the National Natural Science Foundation of China
文摘The method of numerical simulation was applied to investigate the effects of jet impinging plate thickness and its thermal conductivity on the local heat flux distribution along the impinging plate. The results show that the two factors have great effects on the heat flux distribution. The non-uniformity of the local heat-flux on the impinging plate surface gets more profound as the plate becomes thicker and thermal conductivity gets larger. When Reynolds number is 5000, the ratio of nozzle-to-plate spacing to nozzle diameter is 5 and thermal conductivity is 16W/(m·K), and even for the plate with only 25μm in thickness, the non-uniformity of the heat flux cannot be neglected. When the plate thickness is 50 μm, only when thermal conductivity is as small as 1W/(m·K), the heat flux curve can be approximately treated as an iso-heat-flux boundary. In the experimental research, a real non-iso-heat-flux boundary is treated as an iso-heat-flux boundary, which would result in under-estimated Nusselt number value in the stagnation zone and an over-estimated value outside. Such an experimental Nusselt number distribution is taken to evaluate turbulent model, and the conclusion would be drawn that the turbulent model over-predicts the stagnation heat transfer. This is one of the important reasons why many literatures reported that k-ε turbulent model dramatically over-predicts the impinging jet heat transfer in the stagnation region.
文摘It is only an assumption to simplify the reality that there is no contact force between cracks. In many cases, unilateral crack may be more close to reality, i.e. there is a contact force between cracks. A dynamic experimental system was used to measure the contact force in organic glass with cracks. Curves of time versus contact force established through experiments show that the magnitude of contact force relates to the interrelation among external forces, contact points and falling points.
基金V. ACKNOWLEDGMENTS This work was supported by the National Natural Science Foundation of China (No.10434100) and the Knowledge Innovation Project of Chinese Academy of Sciences.
文摘Based on the reaction microscope at the institute of modern physics, the reaction mechanism in molecular ion-atom collisions is investigated experimentally. The features of this system is illustrated by a kinematically complete experhnent performed for the collision process. Using the so-called list-mode data recording technique and the coincidence measurement, the momentum vector of each fragment from the molecular ion were recorded event by event. The orientation of the molecular axis for H2^+ dissociation reactions could be determined for each event in the off-line analysis. The measured orientation of the molecular ion is believed the same as the one at the instance of collision under axial recoil approximation. The polar angle resolution of the molecular orientation of ±8° was obtained.