AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in...AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixtyeight patients underwent liver biopsy. RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs 482/606 (79.5%); P < 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P < 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS < 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 < FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS > 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations. CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis.展开更多
Objective To study the value of ultrasound elastography in evaluation of ethanol-induced lesions of liver. Methods Alcohol with a dose of 2 ml was injected into a fresh porcine liver under ultrasound guidance to creat...Objective To study the value of ultrasound elastography in evaluation of ethanol-induced lesions of liver. Methods Alcohol with a dose of 2 ml was injected into a fresh porcine liver under ultrasound guidance to create stiff necrosis. Then freehand elastography of the lesion from the identical scan plane was obtained with SONOLINE Antares system using VF10-5 probe at about every 30 seconds till 6 minutes later. The original high quality radiofrequency data were acquired through an ultrasound research interface which was provided by the ultrasound system. Then, corresponding elastograms were produced offline using cross-correlation technique and compared with gross pathology findings. Results Gray-scale sonogram showed a hyperechoic area with acoustic shadow below appeared immediately after alcohol injection. The hyperechoic area tended to be diffuse and its boundary to be illegible with time. On the contrary, the ethanol-induced lesion in elastogram appeared as a low swain hard region surrounded by high strain soft hepatic tissues, with clear but irregular boundaries. Sequential elastograms with the sketched lesion boundaries showed that the lesion area increased in the first 3 minutes after ethanol injection, and then reached a plateau which corresponding to gross specimen. Conclusion Ultrasound elastography is capable of detecting and evaluating the diffusion of ethanol-induced hepatic lesion, and more sensitive and accurate than routine sonography.展开更多
文摘AIM: To evaluate cut-off values and performance of acoustic radiation force impulse imaging (ARFI) using transient elastography [FibroScan■ (FS)] as a reference. METHODS: Six hundred and six patients were enrolled in this study.All patients underwent liver stiffness measurement with FS (FS-LS) and ARFI (with shear wave velocity quantification; ARFI-SWV) and the performance of ARFI in comparison to FS was determined. Sixtyeight patients underwent liver biopsy. RESULTS: Significantly higher success rates for the determination of liver stiffness were found using ARFI as compared to FS [604/606 (99.7%) vs 482/606 (79.5%); P < 0.001]. ARFI-SWV correlated significantly with FS-LS (r = 0.920, P < 0.001). ARFI-SWV increased significantly with the stage of fibrosis (1.09 ± 0.13 m/s for patients with no significant fibrosis (FS-LS < 7.6 kPa); 1.46 ± 0.27 m/s for patients with significant liver fibrosis (7.6 < FS-LS ≤ 13.0 kPa); and 2.55 ± 0.77 m/s for patients with liver cirrhosis (FS-LS > 13.0 kPa)). ARFI-SWV cut-off values were identified for no significant fibrosis (1.29 m/s; sensitivity 91.4% and specificity 92.6%) and for liver cirrhosis (1.60 m/s; sensitivity 92.3% and specificity 96.5%). The optimal cut-off value for predicting liver fibrosis (F ≥ 2) was 1.32 m/s (sensitivity 87.0% and specificity 80.0%) and for liver cirrhosis (F4) 1.62 m/s (sensitivity 100% and specificity 85.7%), for patients who underwent liver biopsy. An excellent inter-and intraobserver reproducibility was observed for ARFI-SWV determinations. CONCLUSION: An ARFI-SWV cut-off value of 1.29 m/s seems to be optimal for patients with no significant liver fibrosis and 1.60 m/s for patients with liver cirrhosis.
基金Supported by National Natural Science Foundation of China (30470466)
文摘Objective To study the value of ultrasound elastography in evaluation of ethanol-induced lesions of liver. Methods Alcohol with a dose of 2 ml was injected into a fresh porcine liver under ultrasound guidance to create stiff necrosis. Then freehand elastography of the lesion from the identical scan plane was obtained with SONOLINE Antares system using VF10-5 probe at about every 30 seconds till 6 minutes later. The original high quality radiofrequency data were acquired through an ultrasound research interface which was provided by the ultrasound system. Then, corresponding elastograms were produced offline using cross-correlation technique and compared with gross pathology findings. Results Gray-scale sonogram showed a hyperechoic area with acoustic shadow below appeared immediately after alcohol injection. The hyperechoic area tended to be diffuse and its boundary to be illegible with time. On the contrary, the ethanol-induced lesion in elastogram appeared as a low swain hard region surrounded by high strain soft hepatic tissues, with clear but irregular boundaries. Sequential elastograms with the sketched lesion boundaries showed that the lesion area increased in the first 3 minutes after ethanol injection, and then reached a plateau which corresponding to gross specimen. Conclusion Ultrasound elastography is capable of detecting and evaluating the diffusion of ethanol-induced hepatic lesion, and more sensitive and accurate than routine sonography.