The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS)...The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.展开更多
This paper proposes a family of PWM modulation strategies for boostfull-bridge (FB) converters. The modulation strategies can be classified into two kinds according tothe turn-on sequence of the diagonal switches. The...This paper proposes a family of PWM modulation strategies for boostfull-bridge (FB) converters. The modulation strategies can be classified into two kinds according tothe turn-on sequence of the diagonal switches. The concept of leading switches and lagging switchesis introduced to realize soft-switching. According to the soft-switching realized by the leadingswitches and the lagging switches, two kinds of soft-switching techniques for PWM boost FBconverters yield: zero-current-switching (ZCS) and zero-current and zero-voltage-switching (ZCZVS).Simulation results verify the analysis.展开更多
The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inve...The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...展开更多
This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load ra...This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load range using the energy of the output capacitor. Ma king use of parasitic capacitors of the lagging switches and parallel auxiliary i nductance with the primary winding of the transformer, the lagging switches can realize zero voltage switching (ZVS) under any load. Compared with the ZCS PWM Boost FB converter, the new converter has no current duty cycle loss. Operat ional principle and parameter design are analyzed. Experimental results verify the effectiveness of the proposed converter.展开更多
The soft switching operation principle and operation performance of rugged resonant pole (RRP) is given. The applications of RRP in soft switching DC DC converter and soft switching inverter are discussed in detail. R...The soft switching operation principle and operation performance of rugged resonant pole (RRP) is given. The applications of RRP in soft switching DC DC converter and soft switching inverter are discussed in detail. RRP can constitute buck boost soft switching DC DC converter and isolated soft switching DC DC converter with the automatic limitation performance of output power. Partial series resonant DC DC converter with RRP can realize the zero voltage/zero current switching of power devices. RR...展开更多
A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse c...A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.展开更多
A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft swi...A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.展开更多
Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A ...Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.展开更多
Elastic control could balance the distributed control plane in Software-Defined Networking(SDN). Dynamic switch migration has been proposed to achieve it. However, existing schemes mainly focus on how to execute migra...Elastic control could balance the distributed control plane in Software-Defined Networking(SDN). Dynamic switch migration has been proposed to achieve it. However, existing schemes mainly focus on how to execute migration operation, but not why. This paper designs a decision-making mechanism based on zero-sum game theory to reelect a new controller as the master for migrated switches. It first chooses a switch for migration in the heavy controller which invites its neighbors as the game players to compete for the master role of this switch in the game-playing field(GPF) which is an occasional and loose domain for game-playing. Second, based on the concept of GPF, we design a decentralized strategy to play the game and determine which player as the final master. We implement it by extending the Open Flow protocol. Finally, numerical results demonstrate that our distributed strategy can approach elastic control plane with better performance.展开更多
When solving a mathematical problem, we sometimes encounter a situation where we can not reach a correct answer in spite of acquiring knowledge and formula necessary for the solution. The reason can be attributed to t...When solving a mathematical problem, we sometimes encounter a situation where we can not reach a correct answer in spite of acquiring knowledge and formula necessary for the solution. The reason can be attributed to the lack in metacognitive abilities. Metacognitive abilities consist of comparing the difficulty of problem with own ability, proper plan of solution process, and conscious monitoring and control of solution process. The role and importance of metacognitive ability in mathematical problem solving of permutations and combinations was explored. Participants were required to solve five practical problems related to permutations and combinations. For each problem, the solution process was divided into: (1) understanding (recognition) of mathematical problem; (2) plan of solution; (3) execution of solution. Participants were also required to rate the anticipation whether they could solve it or not, and to rate the confidence of their own answer. According to the total score of five problems, the participants were categorized into the group of the high test score and the group of the low test score. As a result, at the plan and the execution processes, statistically significant differences were detected between the high and the low score groups. As for the rating on the anticipation of result and the confidence of own answer, no significant differences were found between both groups. Moreover, the relationship between the score of plan process and the score of execution process was statistically correlated. In other words, the more proper the plan process was conducted, the more proper solution the participants reached. In such a way, the importance of metacognitive ability in the solving process, especially the plan ability, was suggested.展开更多
The performance of complementary feeders, running in parallel, can be significantly improved by installing static transfer switches (STSs) at critical locations. We develop the STS control logic, which transfers the...The performance of complementary feeders, running in parallel, can be significantly improved by installing static transfer switches (STSs) at critical locations. We develop the STS control logic, which transfers the critical load from the preferred feeder to the alternate feeder when a voltage sag or a fault occurs on the preferred feeder. A forced commutation technique is proposed and implemented to turn off the preferred feeders' thyristor, thus avoiding cross current to flow and minimizing the transfer time. Simulation results show that the forced commutation technique is more effective as compared to the recently proposed time delay technique for STS operation. Two different feeders, namely New Exchange, the preferred feeder, and Sector 1-10/2, the alternate feeder of Islamabad Electric Supply COmpany (IESCO), Pakistan, have been selected for case studies. The software PSCAD/EMTDC professional package has been used for simulation.展开更多
Software Defined Networking (SDN) is an emerging networking paradigm that assumes a logically centralized control plane separated from the data plane. Despite all its advantages, separating the control and data plan...Software Defined Networking (SDN) is an emerging networking paradigm that assumes a logically centralized control plane separated from the data plane. Despite all its advantages, separating the control and data planes introduces new challenges regarding resilient communications between the two. That is, disconnec- tions between switches and their controllers could result in substantial packet loss and performance degradation. This paper addresses this challenge by studying the issue of control traffic protection in SDNs with arbitrary numbers of controllers. Specifically, we propose a control traffic protection scheme that combines both local rerouting and constrained reverse path forwarding protections, through which switches can locally react to fail- ures and redirect the control traffic using standby backup forwarding options. Our goal is then to find a set of primary routes for control traffic, called protected control network, where as many switches as possible can benefit from the proposed protection scheme. We formulate the protected control network problem, prove its NP-hardness, and develop an algorithm that reconciles proteetability and performance (e.g., switch-to-control latency). Through extensive simulations based on real topologies, we show that our approach significantly im- proves protectability of control traffic. The results should help further the process of deploying SDN in real-world networks.展开更多
文摘The application areas of conventional push pull converters are limited because of high voltage stress of switches (twice of input voltage). This paper presents a novel zero voltage and zero current switching (ZCS) PWM push pull three level converter in which the voltage stress of switches is input voltage. With phase shifted modulation strategy, the leading switches can only realize zero voltage switching (ZVS), and the lagging switches can realize ZCS when block capacitor and block diodes are added. Using the strategy, the converter overcomes the drawbacks presented by the conventional push pull converter, such as magnetic aberration, large switch loss, and voltage spike on switches, so it can get higher efficiency, and a wider application area. The operating principle of the new converter is analyzed and verified on a 600 W, 50 kHz experimental prototype. Several zero voltage and zero current switching PWM push pull three level converters are proposed.
文摘This paper proposes a family of PWM modulation strategies for boostfull-bridge (FB) converters. The modulation strategies can be classified into two kinds according tothe turn-on sequence of the diagonal switches. The concept of leading switches and lagging switchesis introduced to realize soft-switching. According to the soft-switching realized by the leadingswitches and the lagging switches, two kinds of soft-switching techniques for PWM boost FBconverters yield: zero-current-switching (ZCS) and zero-current and zero-voltage-switching (ZCZVS).Simulation results verify the analysis.
文摘The conventional inverters have the shortcomings of straightway conduction in transistors and the difficulty of realizing soft swit ̄ching. A novel inverter based on the DC/DC converter topology is presented. The inverter is comprised of a combined Buck/Boost DC/DC converter and a bridge circuit. The front stage converter is controlled to output variable DC voltage and the bridge circuit is used to convert the DC voltage to AC output. The energy feedback technology and one circle control scheme are used t...
文摘This paper proposes a zer o current and zero voltage switching (ZCZVS) PWM Boost full bridge (FB) conve rter. With series inductors, the leading switches can realize zero current swit ching (ZCS) in a wide load range using the energy of the output capacitor. Ma king use of parasitic capacitors of the lagging switches and parallel auxiliary i nductance with the primary winding of the transformer, the lagging switches can realize zero voltage switching (ZVS) under any load. Compared with the ZCS PWM Boost FB converter, the new converter has no current duty cycle loss. Operat ional principle and parameter design are analyzed. Experimental results verify the effectiveness of the proposed converter.
文摘The soft switching operation principle and operation performance of rugged resonant pole (RRP) is given. The applications of RRP in soft switching DC DC converter and soft switching inverter are discussed in detail. RRP can constitute buck boost soft switching DC DC converter and isolated soft switching DC DC converter with the automatic limitation performance of output power. Partial series resonant DC DC converter with RRP can realize the zero voltage/zero current switching of power devices. RR...
文摘A novel resonant dc link soft switching static inverter topology is presented. The soft switching operation principle and pulse width modulation control feature of dc link is analyzed in detail. The discrete pulse control strategy of inverter bridge is discussed. The operation characteristics of inverter are analyzed and verified by experiment.
文摘A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test.
文摘Resonant dc link inverter is a zero voltage switching inverter.This paper proposes a new cascade resonant dc link inverter that consists of two power converter units,a rugged resonant dc link and an inverter bridge.A detailed analysis of the soft switching process in the rugged resonant dc link and the realization of pulse width modulation (PWM) control strategy in the inverter bridge are presented in the paper. The operation modes, the input and output features and the interface between the rugged resonant dc link and the inverter bridge are also discussed. The relationship between the circuit features and the parameters is deduced, which provides a theoretical base for the circuit design. The analysis results show that the rugged resonant dc link can be regulated by open-loop control and the control of the rugged resonant dc link is independent of that of the inverter bridge, which makes the inverter control easy and realizable.The circuit of the inverter is simulated with a standard circuit simulation program PSPICE. The simulation results are corresponding to the predicted ones of the circuit analysis.
基金supported by the Foundation for Innovative Research Groups of the National Natural Science Foundation of China(Grant No.61521003)the National Basic Research Program of China(2012CB315901,2013CB329104)+2 种基金the National Natural Science Foundation of China(Grant No.61372121,61309020,61309019)the National High-Tech Research&Development Program of China(Grant No.2013AA013505)the National Science and Technology Support Program Project(Grant No.2014BAH30B01)
文摘Elastic control could balance the distributed control plane in Software-Defined Networking(SDN). Dynamic switch migration has been proposed to achieve it. However, existing schemes mainly focus on how to execute migration operation, but not why. This paper designs a decision-making mechanism based on zero-sum game theory to reelect a new controller as the master for migrated switches. It first chooses a switch for migration in the heavy controller which invites its neighbors as the game players to compete for the master role of this switch in the game-playing field(GPF) which is an occasional and loose domain for game-playing. Second, based on the concept of GPF, we design a decentralized strategy to play the game and determine which player as the final master. We implement it by extending the Open Flow protocol. Finally, numerical results demonstrate that our distributed strategy can approach elastic control plane with better performance.
文摘When solving a mathematical problem, we sometimes encounter a situation where we can not reach a correct answer in spite of acquiring knowledge and formula necessary for the solution. The reason can be attributed to the lack in metacognitive abilities. Metacognitive abilities consist of comparing the difficulty of problem with own ability, proper plan of solution process, and conscious monitoring and control of solution process. The role and importance of metacognitive ability in mathematical problem solving of permutations and combinations was explored. Participants were required to solve five practical problems related to permutations and combinations. For each problem, the solution process was divided into: (1) understanding (recognition) of mathematical problem; (2) plan of solution; (3) execution of solution. Participants were also required to rate the anticipation whether they could solve it or not, and to rate the confidence of their own answer. According to the total score of five problems, the participants were categorized into the group of the high test score and the group of the low test score. As a result, at the plan and the execution processes, statistically significant differences were detected between the high and the low score groups. As for the rating on the anticipation of result and the confidence of own answer, no significant differences were found between both groups. Moreover, the relationship between the score of plan process and the score of execution process was statistically correlated. In other words, the more proper the plan process was conducted, the more proper solution the participants reached. In such a way, the importance of metacognitive ability in the solving process, especially the plan ability, was suggested.
文摘The performance of complementary feeders, running in parallel, can be significantly improved by installing static transfer switches (STSs) at critical locations. We develop the STS control logic, which transfers the critical load from the preferred feeder to the alternate feeder when a voltage sag or a fault occurs on the preferred feeder. A forced commutation technique is proposed and implemented to turn off the preferred feeders' thyristor, thus avoiding cross current to flow and minimizing the transfer time. Simulation results show that the forced commutation technique is more effective as compared to the recently proposed time delay technique for STS operation. Two different feeders, namely New Exchange, the preferred feeder, and Sector 1-10/2, the alternate feeder of Islamabad Electric Supply COmpany (IESCO), Pakistan, have been selected for case studies. The software PSCAD/EMTDC professional package has been used for simulation.
基金supported in part by National High-tech R&D Program of China(863 Program)(Grant Nos.2013AA0133012015AA016101)
文摘Software Defined Networking (SDN) is an emerging networking paradigm that assumes a logically centralized control plane separated from the data plane. Despite all its advantages, separating the control and data planes introduces new challenges regarding resilient communications between the two. That is, disconnec- tions between switches and their controllers could result in substantial packet loss and performance degradation. This paper addresses this challenge by studying the issue of control traffic protection in SDNs with arbitrary numbers of controllers. Specifically, we propose a control traffic protection scheme that combines both local rerouting and constrained reverse path forwarding protections, through which switches can locally react to fail- ures and redirect the control traffic using standby backup forwarding options. Our goal is then to find a set of primary routes for control traffic, called protected control network, where as many switches as possible can benefit from the proposed protection scheme. We formulate the protected control network problem, prove its NP-hardness, and develop an algorithm that reconciles proteetability and performance (e.g., switch-to-control latency). Through extensive simulations based on real topologies, we show that our approach significantly im- proves protectability of control traffic. The results should help further the process of deploying SDN in real-world networks.