Follow-up of environmental impacts is an integral part of the Environmental Impact Assessment (EIA) process, closely related to the effectiveness of the instrument. EIA follow-up has been receiving a lot of interest f...Follow-up of environmental impacts is an integral part of the Environmental Impact Assessment (EIA) process, closely related to the effectiveness of the instrument. EIA follow-up has been receiving a lot of interest from scientists and practitioners, though it is recognized as one of the weakest points of EIA systems globally. Also, EIA follow-up is influenced by the context, mainly in terms of the types of projects or activities and their related impacts on the environment. Therefore, the present paper is focused on the investigation of the follow-up stage applied to the activity of seismic survey coupled with offshore oil & gas exploitation in Brazil. Research was based on a qualitative approach that included document analysis and semi-structured interviews with analysts involved in EIA processes, and sought to generate evidence of effectiveness of the EIA follow-up as conducted by the Federal Environment Agency (Ibama) in order to situate the practice of follow-up in the broader context of international best practice principles. Based on the findings, it was concluded that, due to the peculiarities of offshore seismic survey, it is necessary to promote adaptations in the procedures for monitoring impacts in order to ensure proper alignment with the principles and conceptual foundations that guide EIA practice. Specifically, the timing of the execution of the activity imposes challenges for its integration into the “conventional” cycle that has guided the monitoring of the impacts in the EIA of projects.展开更多
Introduction: Despite the known benefits of newborn follow-up clinics, attendance has historically been difficult. Infants with reported follow-up difficulty have a greater incidence of severe sensorimotor and cogniti...Introduction: Despite the known benefits of newborn follow-up clinics, attendance has historically been difficult. Infants with reported follow-up difficulty have a greater incidence of severe sensorimotor and cognitive deficits and poorer access to early intervention programs. Our objective was to determine the parent-reported reasons for loss-to-follow up in patients hospitalised at the neonatology unit of Laquintinie Hospital. Methodology: We carried out a cross-sectional study through phone interviews with parents/caregivers of patients hospitalised at Laquintinie over a 2-year period from 1st January 2021 to 31st December 2022. A non-standardised structured interview guide was used for data collection. Loss-to-follow up referred to absence to at least one visit as recorded in the neonatal follow-up chart. All necessary administrative and ethical considerations were duly respected. Results: Most neonates were born through vaginal delivery (n = 313, 69.45%). The neonates were admitted at a median gestational age of 33 weeks (Q1-Q3;32 - 35) and the median duration of hospitalisation was 12 days (Q1 - Q3;8 - 18). A total of 23 neonates had died at the time of interview giving a mortality rate of 5.1%. The three most reported reasons for loss-to-follow-up was lack of money (n = 310, 68.13%), assumption that follow-up had ended (n = 37, 8.13%), and newborn that died (n = 23, 5.1%). Conclusion: This study highlights the significant impact of financial constraints and absence of a robust follow-up system on poor uptake of neonatal follow-up post-discharge in resource limited settings like Cameroon. Our results serve as advocacy for national health insurance especially in neonates.展开更多
Cam-followers provide reliable and controlled motions in various mechanical systems. Due to the highly fluctuating load between the cam and follower in operation, the cam-follower may be subjected to a high risk of co...Cam-followers provide reliable and controlled motions in various mechanical systems. Due to the highly fluctuating load between the cam and follower in operation, the cam-follower may be subjected to a high risk of contact fatigue failure. This paper assesses the fatigue life of a cycloidal displacement cam and a flat-faced follower under the defined loads and constraints. Computer-aided design (CAD) model of the cam-follower is developed in CATIA software and imported to ANSYS software for finite element analysis (FEA) of fatigue life. MATLAB programming is developed for determining the appropriate spring constant and pre-load force to always keep the cam and follower in contact. The fatigue life of the cam-follower has been estimated under the specified operating conditions. The analysis method can be applied to investigate the fatigue life of cams with other profiles, including the modified trapezoidal functions, polynomial functions, etc.展开更多
描述了多处理机环境中 FIRST 和 FOLLOW 集合求解的一种并行处理方法,并讨论了 FIRST 和 FOLLOW 集合的并行算法设计思想和它的实现策略,在构造文法 G 的 LL(1)分析表以及判定文法 G 是否 LL(1)文法时,求解 FIRST 和 FOLLOW 集合是很重...描述了多处理机环境中 FIRST 和 FOLLOW 集合求解的一种并行处理方法,并讨论了 FIRST 和 FOLLOW 集合的并行算法设计思想和它的实现策略,在构造文法 G 的 LL(1)分析表以及判定文法 G 是否 LL(1)文法时,求解 FIRST 和 FOLLOW 集合是很重要的内容,由于文法中终结符和非终结符个数很多,考虑 FIRST 和 FOLLOW 集合的并行处理方法,对并行编译处理和提高效率有其理论和现实意义。展开更多
文摘Follow-up of environmental impacts is an integral part of the Environmental Impact Assessment (EIA) process, closely related to the effectiveness of the instrument. EIA follow-up has been receiving a lot of interest from scientists and practitioners, though it is recognized as one of the weakest points of EIA systems globally. Also, EIA follow-up is influenced by the context, mainly in terms of the types of projects or activities and their related impacts on the environment. Therefore, the present paper is focused on the investigation of the follow-up stage applied to the activity of seismic survey coupled with offshore oil & gas exploitation in Brazil. Research was based on a qualitative approach that included document analysis and semi-structured interviews with analysts involved in EIA processes, and sought to generate evidence of effectiveness of the EIA follow-up as conducted by the Federal Environment Agency (Ibama) in order to situate the practice of follow-up in the broader context of international best practice principles. Based on the findings, it was concluded that, due to the peculiarities of offshore seismic survey, it is necessary to promote adaptations in the procedures for monitoring impacts in order to ensure proper alignment with the principles and conceptual foundations that guide EIA practice. Specifically, the timing of the execution of the activity imposes challenges for its integration into the “conventional” cycle that has guided the monitoring of the impacts in the EIA of projects.
文摘Introduction: Despite the known benefits of newborn follow-up clinics, attendance has historically been difficult. Infants with reported follow-up difficulty have a greater incidence of severe sensorimotor and cognitive deficits and poorer access to early intervention programs. Our objective was to determine the parent-reported reasons for loss-to-follow up in patients hospitalised at the neonatology unit of Laquintinie Hospital. Methodology: We carried out a cross-sectional study through phone interviews with parents/caregivers of patients hospitalised at Laquintinie over a 2-year period from 1st January 2021 to 31st December 2022. A non-standardised structured interview guide was used for data collection. Loss-to-follow up referred to absence to at least one visit as recorded in the neonatal follow-up chart. All necessary administrative and ethical considerations were duly respected. Results: Most neonates were born through vaginal delivery (n = 313, 69.45%). The neonates were admitted at a median gestational age of 33 weeks (Q1-Q3;32 - 35) and the median duration of hospitalisation was 12 days (Q1 - Q3;8 - 18). A total of 23 neonates had died at the time of interview giving a mortality rate of 5.1%. The three most reported reasons for loss-to-follow-up was lack of money (n = 310, 68.13%), assumption that follow-up had ended (n = 37, 8.13%), and newborn that died (n = 23, 5.1%). Conclusion: This study highlights the significant impact of financial constraints and absence of a robust follow-up system on poor uptake of neonatal follow-up post-discharge in resource limited settings like Cameroon. Our results serve as advocacy for national health insurance especially in neonates.
文摘Cam-followers provide reliable and controlled motions in various mechanical systems. Due to the highly fluctuating load between the cam and follower in operation, the cam-follower may be subjected to a high risk of contact fatigue failure. This paper assesses the fatigue life of a cycloidal displacement cam and a flat-faced follower under the defined loads and constraints. Computer-aided design (CAD) model of the cam-follower is developed in CATIA software and imported to ANSYS software for finite element analysis (FEA) of fatigue life. MATLAB programming is developed for determining the appropriate spring constant and pre-load force to always keep the cam and follower in contact. The fatigue life of the cam-follower has been estimated under the specified operating conditions. The analysis method can be applied to investigate the fatigue life of cams with other profiles, including the modified trapezoidal functions, polynomial functions, etc.
文摘描述了多处理机环境中 FIRST 和 FOLLOW 集合求解的一种并行处理方法,并讨论了 FIRST 和 FOLLOW 集合的并行算法设计思想和它的实现策略,在构造文法 G 的 LL(1)分析表以及判定文法 G 是否 LL(1)文法时,求解 FIRST 和 FOLLOW 集合是很重要的内容,由于文法中终结符和非终结符个数很多,考虑 FIRST 和 FOLLOW 集合的并行处理方法,对并行编译处理和提高效率有其理论和现实意义。