由于原调频广播“N+1”自动播出系统出现异常但无备件可更换,技术人员根据原系统运行原理,重建软硬件平台,成功更新了该系统的播出主控单元。对此,介绍无线调频广播“N+1”播出系统的工作原理,描述如何通过Agilent VEE Pro软件来解决更...由于原调频广播“N+1”自动播出系统出现异常但无备件可更换,技术人员根据原系统运行原理,重建软硬件平台,成功更新了该系统的播出主控单元。对此,介绍无线调频广播“N+1”播出系统的工作原理,描述如何通过Agilent VEE Pro软件来解决更新过程中出现的硬件识别等问题,为设备的维护更新提供参考。展开更多
Southern Africa has experienced electric power deficits over the last decade. This has been due in part to the member countries' inadequate electrical power supply system, as well as load growth in areas which were n...Southern Africa has experienced electric power deficits over the last decade. This has been due in part to the member countries' inadequate electrical power supply system, as well as load growth in areas which were not adequately planned for. This has induced the formation of organizations such as SADC (Southern African Development Community) and SAPP (Southern African Power Pool) that have the common goal of achieving development and economic growth in the region which comprises of 15 member countries. This paper presents results from a security analysis of the region's electric power supply system using a baseline level of performance. This was carried out by performing a steady-state contingency analysis on a SADC power network model subject to the N-1 criteria which expresses the ability of the power network to experience a contingency without causing an overload or failure in any other part of the network. Simulations were carried out using DigSilent.展开更多
文摘由于原调频广播“N+1”自动播出系统出现异常但无备件可更换,技术人员根据原系统运行原理,重建软硬件平台,成功更新了该系统的播出主控单元。对此,介绍无线调频广播“N+1”播出系统的工作原理,描述如何通过Agilent VEE Pro软件来解决更新过程中出现的硬件识别等问题,为设备的维护更新提供参考。
文摘Southern Africa has experienced electric power deficits over the last decade. This has been due in part to the member countries' inadequate electrical power supply system, as well as load growth in areas which were not adequately planned for. This has induced the formation of organizations such as SADC (Southern African Development Community) and SAPP (Southern African Power Pool) that have the common goal of achieving development and economic growth in the region which comprises of 15 member countries. This paper presents results from a security analysis of the region's electric power supply system using a baseline level of performance. This was carried out by performing a steady-state contingency analysis on a SADC power network model subject to the N-1 criteria which expresses the ability of the power network to experience a contingency without causing an overload or failure in any other part of the network. Simulations were carried out using DigSilent.