A well-known hazardous metal and top contaminant in wastewater is hexavalent chromium. The two forms of most commonly found chromium are chromate ( CrO 4 2− ) and dichromate ( Cr 2 O 7 2− ). Leather tanning, cooling t...A well-known hazardous metal and top contaminant in wastewater is hexavalent chromium. The two forms of most commonly found chromium are chromate ( CrO 4 2− ) and dichromate ( Cr 2 O 7 2− ). Leather tanning, cooling tower blow-down, plating, electroplating, rinse water sources, anodizing baths etc. are the main sources of Cr (VI) contamination. The Cr (VI) is not only non-biodegradable in the environment but also carcinogenic to living population. It is still difficult to treat Cr contaminated waste water effectively, safely, eco-friendly, and economically. As a result, many techniques have been used to treat Cr (VI)-polluted wastewater, including adsorption, chemical precipitation, coagulation, ion-exchange, and filtration. Among these practices, the most practical method is adsorption for the removal of Cr (VI) from aqueous solutions, which has gained widespread acceptance due to the ease of use and affordability of the equipment and adsorbent. It has been revealed that Fe-based adsorbents’ oxides and hydroxides have high adsorptive potential to lower Cr (VI) content below the advised threshold. Fe-based adsorbents were also discovered to be relatively cheap and toxic-free in Cr (VI) treatment. Fe-based adsorbents are commonly utilized in industry. It has been discovered that nanoparticles of Fe-, Ti-, and Cu-based adsorbents have a better capacity to remove Cr (VI). Cr (VI) was effectively removed from contaminated water using mixed element-based adsorbents (Fe-Mn, Fe-Ti, Fe-Cu, Fe-Zr, Fe-Cu-Y, Fe-Mg, etc.). Initial findings suggest that Cr (VI) removal from wastewater may be accomplished by using magnesium ferrite nanomaterials as an efficient adsorbent.展开更多
Background: Dying in childbirth is one of the most common causes of death for women. While maternal mortality rates, defined as deaths per 100,000 live births, have been steadily dropping in most countries worldwide, ...Background: Dying in childbirth is one of the most common causes of death for women. While maternal mortality rates, defined as deaths per 100,000 live births, have been steadily dropping in most countries worldwide, maternal mortality rates have doubled in the United States in the last twenty years. This commentary examines the various contributing factors to this trend. Methods: A literature review was performed using the keywords: maternal mortality, United States, disrespectful maternity care, obstetric violence, provider perspectives, and disparities. Maternal mortality statistics were obtained from the World Health Organization website. Results: Medical factors associated with maternal mortality include increased maternal age and cardiovascular conditions. Social factors include barriers to healthcare access, delays in receiving medical care, reduction in reproductive health services in some states, and non-obstetrical deaths such as accidents, domestic violence, and suicide. Racial inequities and disparities of care are reflected in higher maternal mortality rates for minorities and people of color. Disrespectful maternity care or obstetric violence has been reported worldwide as a factor in delay of lifesaving obstetrical care and reluctance by a pregnant person to access the healthcare system. About one in five US women has reported experiencing mistreatment, varying from verbal abuse to lack of privacy, from coerced procedures to neglect during childbirth. Conclusion: This commentary highlights the importance of inclusion of providers in research on respectful maternity care. Provider burnout, moral distress, limited time, and burden of clinical responsibilities are known challenges to respectful and comprehensive medical care. The association of disrespectful care with poor maternal outcomes needs to be studied. Exploring root causes of disrespectful childbirth care can empower nurses, midwives, and physicians to improve their environment and find solutions to reduce a potential cause of maternal mortality.展开更多
针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系...针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系统的硬件,同时采用Mark VIe ControlST统一软件平台。结果表明:新控制系统采用了一体化硬件、软件设计,提高了机组控制系统的安全可靠性,有利于日常运行维护,而且新系统具有在线监测功能,有助于系统故障排查。展开更多
Commercial ELISA kits are commonly used to assess the levels of chicken antibodies against NewCastle Disease Virus (NDV) and trace a field strain infection. Nevertheless, the specificity of these kits vis-à-vis e...Commercial ELISA kits are commonly used to assess the levels of chicken antibodies against NewCastle Disease Virus (NDV) and trace a field strain infection. Nevertheless, the specificity of these kits vis-à-vis endemic strains in Lebanon remains in question. This study developed an in-house indirect ELISA system to evaluate the level of chicken antibodies against a predominant velogenic NDV strain belonging to Genotype VI. A checkerboard analysis comprised a five-factorial multivariate experiment to optimize the protocol: coating antigen concentration, blocking buffer utilization, serum and conjugate dilution levels, and OD reading wavelength. The developed test was optimized and then validated through parallel testing of the sera of 20 broilers and 5 layers using standard serological assays. There was a strong correlation between the developed ELISA results and those obtained with the Hemagglutination Inhibition test (P < 0.01), and a commercial NDV ELISA kit (P < 0.05). The specificity, sensitivity, and reproducibility of the developed ELISA suggest that it can be used as the test of choice for the assessment of chicken antibody titers against locally circulating velogenic NDV strains, specifically those belonging to Genotype VI. It also offers better help in the serological detection of birds’ exposure to the said strains.展开更多
文摘A well-known hazardous metal and top contaminant in wastewater is hexavalent chromium. The two forms of most commonly found chromium are chromate ( CrO 4 2− ) and dichromate ( Cr 2 O 7 2− ). Leather tanning, cooling tower blow-down, plating, electroplating, rinse water sources, anodizing baths etc. are the main sources of Cr (VI) contamination. The Cr (VI) is not only non-biodegradable in the environment but also carcinogenic to living population. It is still difficult to treat Cr contaminated waste water effectively, safely, eco-friendly, and economically. As a result, many techniques have been used to treat Cr (VI)-polluted wastewater, including adsorption, chemical precipitation, coagulation, ion-exchange, and filtration. Among these practices, the most practical method is adsorption for the removal of Cr (VI) from aqueous solutions, which has gained widespread acceptance due to the ease of use and affordability of the equipment and adsorbent. It has been revealed that Fe-based adsorbents’ oxides and hydroxides have high adsorptive potential to lower Cr (VI) content below the advised threshold. Fe-based adsorbents were also discovered to be relatively cheap and toxic-free in Cr (VI) treatment. Fe-based adsorbents are commonly utilized in industry. It has been discovered that nanoparticles of Fe-, Ti-, and Cu-based adsorbents have a better capacity to remove Cr (VI). Cr (VI) was effectively removed from contaminated water using mixed element-based adsorbents (Fe-Mn, Fe-Ti, Fe-Cu, Fe-Zr, Fe-Cu-Y, Fe-Mg, etc.). Initial findings suggest that Cr (VI) removal from wastewater may be accomplished by using magnesium ferrite nanomaterials as an efficient adsorbent.
文摘Background: Dying in childbirth is one of the most common causes of death for women. While maternal mortality rates, defined as deaths per 100,000 live births, have been steadily dropping in most countries worldwide, maternal mortality rates have doubled in the United States in the last twenty years. This commentary examines the various contributing factors to this trend. Methods: A literature review was performed using the keywords: maternal mortality, United States, disrespectful maternity care, obstetric violence, provider perspectives, and disparities. Maternal mortality statistics were obtained from the World Health Organization website. Results: Medical factors associated with maternal mortality include increased maternal age and cardiovascular conditions. Social factors include barriers to healthcare access, delays in receiving medical care, reduction in reproductive health services in some states, and non-obstetrical deaths such as accidents, domestic violence, and suicide. Racial inequities and disparities of care are reflected in higher maternal mortality rates for minorities and people of color. Disrespectful maternity care or obstetric violence has been reported worldwide as a factor in delay of lifesaving obstetrical care and reluctance by a pregnant person to access the healthcare system. About one in five US women has reported experiencing mistreatment, varying from verbal abuse to lack of privacy, from coerced procedures to neglect during childbirth. Conclusion: This commentary highlights the importance of inclusion of providers in research on respectful maternity care. Provider burnout, moral distress, limited time, and burden of clinical responsibilities are known challenges to respectful and comprehensive medical care. The association of disrespectful care with poor maternal outcomes needs to be studied. Exploring root causes of disrespectful childbirth care can empower nurses, midwives, and physicians to improve their environment and find solutions to reduce a potential cause of maternal mortality.
文摘针对当前集成了不同厂家几套子系统的一些燃驱压缩机组控制系统结构复杂、维护成本高等问题,应用基于Mark VIe控制平台来升级改造该系统。以某改造项目为例,应用双冗余Mark VIe控制系统架构,Mark VIe SIL3模件作为紧急停机和火气保护系统的硬件,同时采用Mark VIe ControlST统一软件平台。结果表明:新控制系统采用了一体化硬件、软件设计,提高了机组控制系统的安全可靠性,有利于日常运行维护,而且新系统具有在线监测功能,有助于系统故障排查。
文摘Commercial ELISA kits are commonly used to assess the levels of chicken antibodies against NewCastle Disease Virus (NDV) and trace a field strain infection. Nevertheless, the specificity of these kits vis-à-vis endemic strains in Lebanon remains in question. This study developed an in-house indirect ELISA system to evaluate the level of chicken antibodies against a predominant velogenic NDV strain belonging to Genotype VI. A checkerboard analysis comprised a five-factorial multivariate experiment to optimize the protocol: coating antigen concentration, blocking buffer utilization, serum and conjugate dilution levels, and OD reading wavelength. The developed test was optimized and then validated through parallel testing of the sera of 20 broilers and 5 layers using standard serological assays. There was a strong correlation between the developed ELISA results and those obtained with the Hemagglutination Inhibition test (P < 0.01), and a commercial NDV ELISA kit (P < 0.05). The specificity, sensitivity, and reproducibility of the developed ELISA suggest that it can be used as the test of choice for the assessment of chicken antibody titers against locally circulating velogenic NDV strains, specifically those belonging to Genotype VI. It also offers better help in the serological detection of birds’ exposure to the said strains.