The AGCU X Plus STR system is a newly developed multiplex PCR kit that detects 32 X-chromosomal STR loci simultaneously.These are DXS6807,DXS9895,linkage group 1(DXS10148,DXS10135,DXS8378),DXS9902,DXS6795,DXS6810,DXS1...The AGCU X Plus STR system is a newly developed multiplex PCR kit that detects 32 X-chromosomal STR loci simultaneously.These are DXS6807,DXS9895,linkage group 1(DXS10148,DXS10135,DXS8378),DXS9902,DXS6795,DXS6810,DXS10159,DXS10162,DXS10164,DXS7132,linkage group 2(DXS10079,DXS10074,DXS10075),DXS981,DXS6800,DXS6803,DXS6809,DXS6789,DXS7424,DXS101,DXS7133,GATA172D05,GATA165B12,linkage group 3(DXS10103,HPRTB,DXS10101),GATA31E08 and linkage group 4(DXS8377,DXS10134,DXS7423).A major advantage of this kit is that it takes into account linkage between loci,in addition to detecting more X-STR loci.In order to evaluate the forensic application of 32 X-STR fl uorescence amplifi cation system,PCR settings,sensitivity,species specifi city,stability,DNA mixtures,concordance,stutter,sizing precision,and population genetics investigation were evaluated according to the Scientific Working Group on DNA Analysis Methods(SWGDAM)developmental validation guidelines.The study showed that the genotyping results of each locus were signifi cantly accurate when the DNA template was at least 62.5 pg.Complete profi les were obtained for the 1∶1 and 1∶3 combinations.A total of 209 unrelated individuals from Southern Chinese Han community,consisting of 84 females and 125 males,were selected for population studies,and 285 allele profi les were detected from 32 X-STR loci.The polymorphism information content(PIC)ranged from 0.2721 in DXS6800,to 0.9105 in DXS10135,with an average of 0.6798.DXS10135(PIC=0.9105)was the most polymorphic locus,with discrimination power(DP)of 0.9164 and 0.9871 for the male and female.The cumulative PD_(F),PD_(M),MEC_(trio) and MEC_(duo) valu es were all greater than 0.999999999.There were 78 different DXS10103-HPRTB-DXS10101 haplotypes among the 125 males,and the haplotype diversity was 0.9810.There was no signifi cant difference in the cumulative PD_(F),PD_(M),MEC_(trio) and MEC_(duo) values whether considering linkage or not.In summary,the new X-STR multiplex typing system is effective and reliable,which can be useful in human genetic analysis and kinship testing as a potent complement to autosomal STR typing.展开更多
A special cloth for keeping LiF(Mg,Cu,P)TL dosimetry elements is worn by examinees. The exposures of 128 examinees .received upper G.I.T (gastro-intestinal tram) X-ray examination are measured. The reference point of ...A special cloth for keeping LiF(Mg,Cu,P)TL dosimetry elements is worn by examinees. The exposures of 128 examinees .received upper G.I.T (gastro-intestinal tram) X-ray examination are measured. The reference point of the maximum body surface exposure given is at the middle of stomach. The average of this point is (4.97±1.94) × 10-4C.kg-1 person-1 examination-1 and (1.33±0.28)×10-4C.kg-1.min-1.展开更多
Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the fiel...Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple.展开更多
Three-dimensional reconstructions from tomography slices are paid great attention in medical applications nowadays. This paper introduces the design and the implement of VolGraph system: a new, inexpensive, PC-based v...Three-dimensional reconstructions from tomography slices are paid great attention in medical applications nowadays. This paper introduces the design and the implement of VolGraph system: a new, inexpensive, PC-based visualization tool for three-dimensional medical reconstructions, which fully integrates the latest popular visualization algorithms ranging from classical surface rendering algorithm to volume rendering algorithms, such as Ray Casting, Splatting, and Shear-Warp.The input of VolGraph can be medical ima- ges including CT, MRI, etc, and the output can be in common image, VRML/XML or animation formats. Practice proves that the realization of a medical volume visualization system is now feasible on desktop PCs.展开更多
OBJECTIVE:To master the syndrome patterns characteristics and explore the effective therapy methods ofTraditional Chinese Medicine(TCM) for cardiac syndrome X(CSX).METHODS:The TCM syndrome characteristics were mastere...OBJECTIVE:To master the syndrome patterns characteristics and explore the effective therapy methods ofTraditional Chinese Medicine(TCM) for cardiac syndrome X(CSX).METHODS:The TCM syndrome characteristics were mastered and the TCM intervention programs were determined by clinical investigations for TCM syndrome patterns characteristics of CSX patients.Then,the clinical efficacy studies on TCM intervention for CSX were carried out through randomized controlled trials.RESULTS:CSX is a clinical syndrome with the main manifestations of chest pain and chest stuffiness,and Qi stagnation,phlegm retention and blood stasis are the basic symptoms of CSX.As a result,the Qi-regulating,chest-relaxing and blood-activating therapy integrated with some Western Medicines was adopted for treatment.The effect of Qi-regulating,chest-relaxing and blood-activating therapy can reduce the frequency and degree of angina,improve the symptoms and exercise the tolerance of patients,inhibit the inflammatory response of vascular walls and protect the function of vascular endothelial cells,which is better than that of the simple and conventionalWestern Medicine alone.CONCLUSION:A good effect was achieved in the integration of Chinese and Western Medicines for CSX.The therapy is worthy to be applied further in clinical practice.On the other hand,more long-term and randomised controlled studies with large samples are still required to further determine the clinical efficacy and safety of the therapy.展开更多
文摘The AGCU X Plus STR system is a newly developed multiplex PCR kit that detects 32 X-chromosomal STR loci simultaneously.These are DXS6807,DXS9895,linkage group 1(DXS10148,DXS10135,DXS8378),DXS9902,DXS6795,DXS6810,DXS10159,DXS10162,DXS10164,DXS7132,linkage group 2(DXS10079,DXS10074,DXS10075),DXS981,DXS6800,DXS6803,DXS6809,DXS6789,DXS7424,DXS101,DXS7133,GATA172D05,GATA165B12,linkage group 3(DXS10103,HPRTB,DXS10101),GATA31E08 and linkage group 4(DXS8377,DXS10134,DXS7423).A major advantage of this kit is that it takes into account linkage between loci,in addition to detecting more X-STR loci.In order to evaluate the forensic application of 32 X-STR fl uorescence amplifi cation system,PCR settings,sensitivity,species specifi city,stability,DNA mixtures,concordance,stutter,sizing precision,and population genetics investigation were evaluated according to the Scientific Working Group on DNA Analysis Methods(SWGDAM)developmental validation guidelines.The study showed that the genotyping results of each locus were signifi cantly accurate when the DNA template was at least 62.5 pg.Complete profi les were obtained for the 1∶1 and 1∶3 combinations.A total of 209 unrelated individuals from Southern Chinese Han community,consisting of 84 females and 125 males,were selected for population studies,and 285 allele profi les were detected from 32 X-STR loci.The polymorphism information content(PIC)ranged from 0.2721 in DXS6800,to 0.9105 in DXS10135,with an average of 0.6798.DXS10135(PIC=0.9105)was the most polymorphic locus,with discrimination power(DP)of 0.9164 and 0.9871 for the male and female.The cumulative PD_(F),PD_(M),MEC_(trio) and MEC_(duo) valu es were all greater than 0.999999999.There were 78 different DXS10103-HPRTB-DXS10101 haplotypes among the 125 males,and the haplotype diversity was 0.9810.There was no signifi cant difference in the cumulative PD_(F),PD_(M),MEC_(trio) and MEC_(duo) values whether considering linkage or not.In summary,the new X-STR multiplex typing system is effective and reliable,which can be useful in human genetic analysis and kinship testing as a potent complement to autosomal STR typing.
文摘A special cloth for keeping LiF(Mg,Cu,P)TL dosimetry elements is worn by examinees. The exposures of 128 examinees .received upper G.I.T (gastro-intestinal tram) X-ray examination are measured. The reference point of the maximum body surface exposure given is at the middle of stomach. The average of this point is (4.97±1.94) × 10-4C.kg-1 person-1 examination-1 and (1.33±0.28)×10-4C.kg-1.min-1.
基金supported by Dr.Guohua Cao’s CAREER award from the U.S.National Science Foundation(CBET 1351936)
文摘Although discovered more than 100 years ago, X-ray source technology has evolved rather slowly. The recent invention of the carbon nanotube (CNT) X-ray source technology holds great promise to revolutionize the field of biomedical X-ray imaging. CNT X-ray sources have been successfully adapted to several biomedical imaging applications including dynamic rnicro-CT of small animals and stationary breast tomosynthesis of breast cancers. Yet their more irnportant biomedical imaging applications still lie ahead in the future, with the devel- oprnent of stationary rnulti-source CT as a noteworthy exarnple.
文摘Three-dimensional reconstructions from tomography slices are paid great attention in medical applications nowadays. This paper introduces the design and the implement of VolGraph system: a new, inexpensive, PC-based visualization tool for three-dimensional medical reconstructions, which fully integrates the latest popular visualization algorithms ranging from classical surface rendering algorithm to volume rendering algorithms, such as Ray Casting, Splatting, and Shear-Warp.The input of VolGraph can be medical ima- ges including CT, MRI, etc, and the output can be in common image, VRML/XML or animation formats. Practice proves that the realization of a medical volume visualization system is now feasible on desktop PCs.
基金Supported by Special Project of National Clinical Research Base of TCM (No. JDZX2012140)Innovation Team Development Plan of the Ministry of Education (No. IRT1276)
文摘OBJECTIVE:To master the syndrome patterns characteristics and explore the effective therapy methods ofTraditional Chinese Medicine(TCM) for cardiac syndrome X(CSX).METHODS:The TCM syndrome characteristics were mastered and the TCM intervention programs were determined by clinical investigations for TCM syndrome patterns characteristics of CSX patients.Then,the clinical efficacy studies on TCM intervention for CSX were carried out through randomized controlled trials.RESULTS:CSX is a clinical syndrome with the main manifestations of chest pain and chest stuffiness,and Qi stagnation,phlegm retention and blood stasis are the basic symptoms of CSX.As a result,the Qi-regulating,chest-relaxing and blood-activating therapy integrated with some Western Medicines was adopted for treatment.The effect of Qi-regulating,chest-relaxing and blood-activating therapy can reduce the frequency and degree of angina,improve the symptoms and exercise the tolerance of patients,inhibit the inflammatory response of vascular walls and protect the function of vascular endothelial cells,which is better than that of the simple and conventionalWestern Medicine alone.CONCLUSION:A good effect was achieved in the integration of Chinese and Western Medicines for CSX.The therapy is worthy to be applied further in clinical practice.On the other hand,more long-term and randomised controlled studies with large samples are still required to further determine the clinical efficacy and safety of the therapy.