Among most traditional piezo water cooling systems, piezoelectric valve pumps are adopted as their driving sources. The valves in these pumps induce problems of shock and vibration and also make their structure compli...Among most traditional piezo water cooling systems, piezoelectric valve pumps are adopted as their driving sources. The valves in these pumps induce problems of shock and vibration and also make their structure complicated, which is uneasy to minimize and reduce their reliability and applicability of the whole system. In order to avoid these problems caused by valve structure, a novel valveless piezoelectric pump is developed, which integrates both functions of transforming and cooling. The pump’s Y-shape tree-like construction not only increases the efficiency of cooling but also the system reliability and applicability. Firstly, a multistage Y-shape treelike bifurcate tube is proposed, then a valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes is designed and its working principle is analyzed. Then, the theoretical analysis of flow resistance characteristics and the flow rate of the valveless piezoelectric pump are performed. Meanwhile, commercial software CFX is employed to perform the numerical simulation for the pump. Finally, this valveless piezoelectric pump is fabricated, the relationship between the flow rates and driving frequency, as well as the relationship between the back pressure and the driving frequency are experimentally investigated. The experimental results show that the maximum flow rate is 35.6 mL/min under 100 V peak-to-peak voltage (10.3 Hz) power supply, and the maximum back pressure is 55 mm H2O under 100 V (9 Hz) power supply, which validates the feasibility of the valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes. The proposed research provides certain references for the design of valveless piezoelectric pump and improves the reliability of piezo water cooling systems.展开更多
Microchannel heat sink with high heat transfer coefficients has been extensively investigated due to its wide application prospective in electronic cooling. However, this cooling system requires a separate pump to dri...Microchannel heat sink with high heat transfer coefficients has been extensively investigated due to its wide application prospective in electronic cooling. However, this cooling system requires a separate pump to drive the fluid transfer, which is uneasy to minimize and reduces their reliability and applicability of the whole system. In order to avoid these problems, valveless piezoelectric pump with fractal-like Y-shape branching tubes is proposed. Fractal-like Y-shape branching tube used in microchannel heat sinks is exploited as no-moving-part valve of the valveless piezoelectric pump. In order to obtain flow characteristics of the pump, the relationship between tube structure and flow rate of the pump is studied. Specifically, the flow resistances of fractal-like Y-shape branching tubes and flow rate of the pump are analyzed by using fractal theory. Then, finite element software is employed to simulate the flow field of the tube, and the relationships between pressure drop and flow rate along merging and dividing flows are obtained. Finally, valveless piezoelectric pumps with fractal-like Y-shape branching tubes with different fractal dimensions of diameter distribution are fabricated, and flow rate experiment is conducted. The experimental results show that the flow rate of the pump increases with the rise of fractal dimension of the tube diameter. When fractal dimension is 3, the maximum flow rate of the valveless pump is 29.16 mL/min under 100 V peak to peak (13 Hz) power supply, which reveals the relationship between flow rate and fractal dimensions of tube diameter distribution. This paper investigates the flow characteristics of valveless piezoelectric pump with fractal-like Y-shape branching tubes, which provides certain references for valveless piezoelectric pump with fractal-like Y-shape branching tubes in application on electronic chip cooling.展开更多
This paper proposed a T- Y tube model to simulate foe input impedance of arterial system. It improves and extends the asymmetric T-tube model which was firstproposed by O' Rourke[1] and developed laier by Liu et a...This paper proposed a T- Y tube model to simulate foe input impedance of arterial system. It improves and extends the asymmetric T-tube model which was firstproposed by O' Rourke[1] and developed laier by Liu et al.[2]. Based on foe asymmetricT-tube model. a T-Y tube model was proposed by adding branching tubes whichrepresem the iliac arteries.All the tubes are considered to be uniform,viscoelasticlongitudinally tethered cylindrical tubes.The upper tube terminates with a windkesselmodel, while the terminal arterioles of the lowr tube are expressed as a resistance.After proper eraluation of the parameters.the impedance of the arterial system iscalculated under normal physiological and hypertensive condition.The model canpredict impedance in good agreement with the experimentally obtained data no matterin normal physiological condition or in pathological condition In comparison with theasymmeric T-tube model,T- Y tube model is closer to anatomy structure of the human arlerial system and at the sametime much simpler than the extremely complex multiplebranching tube model Therefore it will be a valuable model in studying the influencesof various parameters on aorta impedance and ventricular-vascular coupling.展开更多
Being aimed at the inside wall wrinkling and sinking phenomenon of palladium-yttrium alloy thin wall spiral tube used for preparation of high purity hydrogen, extraction of hydrogen isotope, and purification and separ...Being aimed at the inside wall wrinkling and sinking phenomenon of palladium-yttrium alloy thin wall spiral tube used for preparation of high purity hydrogen, extraction of hydrogen isotope, and purification and separation of hydrogen in the winding process, this article analyzed the reasons for above phenomena, established a numerical simulation model of winding process of above tube, using elastic-plastic Finite Element method analyzed the max. tensile stress and max. compression stress and their locations, thereby provides a theory base for the control of working forming course of thin wall spiral tube.展开更多
基金supported by National Natural Science Foundation of China (Grant Nos. 50775109, 50735002, 51075201)Open Fund of State Key Lab of Digital Manufacturing Equipment and Technology of Huazhong University of Science and Technology of China (Grant No.DMETKF2009002)
文摘Among most traditional piezo water cooling systems, piezoelectric valve pumps are adopted as their driving sources. The valves in these pumps induce problems of shock and vibration and also make their structure complicated, which is uneasy to minimize and reduce their reliability and applicability of the whole system. In order to avoid these problems caused by valve structure, a novel valveless piezoelectric pump is developed, which integrates both functions of transforming and cooling. The pump’s Y-shape tree-like construction not only increases the efficiency of cooling but also the system reliability and applicability. Firstly, a multistage Y-shape treelike bifurcate tube is proposed, then a valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes is designed and its working principle is analyzed. Then, the theoretical analysis of flow resistance characteristics and the flow rate of the valveless piezoelectric pump are performed. Meanwhile, commercial software CFX is employed to perform the numerical simulation for the pump. Finally, this valveless piezoelectric pump is fabricated, the relationship between the flow rates and driving frequency, as well as the relationship between the back pressure and the driving frequency are experimentally investigated. The experimental results show that the maximum flow rate is 35.6 mL/min under 100 V peak-to-peak voltage (10.3 Hz) power supply, and the maximum back pressure is 55 mm H2O under 100 V (9 Hz) power supply, which validates the feasibility of the valveless piezoelectric pump with multistage Y-shape treelike bifurcate tubes. The proposed research provides certain references for the design of valveless piezoelectric pump and improves the reliability of piezo water cooling systems.
基金Supported by National Natural Science Foundation of China(Grant Nos.51275235,51375227)Major Research Plan of National Natural Science Foundation of China(Grant No.91223201)Independent Projects Fund of State Key Lab of Mechanics and Control of Mechanical Structures of China(Grant No.0313G01)
文摘Microchannel heat sink with high heat transfer coefficients has been extensively investigated due to its wide application prospective in electronic cooling. However, this cooling system requires a separate pump to drive the fluid transfer, which is uneasy to minimize and reduces their reliability and applicability of the whole system. In order to avoid these problems, valveless piezoelectric pump with fractal-like Y-shape branching tubes is proposed. Fractal-like Y-shape branching tube used in microchannel heat sinks is exploited as no-moving-part valve of the valveless piezoelectric pump. In order to obtain flow characteristics of the pump, the relationship between tube structure and flow rate of the pump is studied. Specifically, the flow resistances of fractal-like Y-shape branching tubes and flow rate of the pump are analyzed by using fractal theory. Then, finite element software is employed to simulate the flow field of the tube, and the relationships between pressure drop and flow rate along merging and dividing flows are obtained. Finally, valveless piezoelectric pumps with fractal-like Y-shape branching tubes with different fractal dimensions of diameter distribution are fabricated, and flow rate experiment is conducted. The experimental results show that the flow rate of the pump increases with the rise of fractal dimension of the tube diameter. When fractal dimension is 3, the maximum flow rate of the valveless pump is 29.16 mL/min under 100 V peak to peak (13 Hz) power supply, which reveals the relationship between flow rate and fractal dimensions of tube diameter distribution. This paper investigates the flow characteristics of valveless piezoelectric pump with fractal-like Y-shape branching tubes, which provides certain references for valveless piezoelectric pump with fractal-like Y-shape branching tubes in application on electronic chip cooling.
文摘This paper proposed a T- Y tube model to simulate foe input impedance of arterial system. It improves and extends the asymmetric T-tube model which was firstproposed by O' Rourke[1] and developed laier by Liu et al.[2]. Based on foe asymmetricT-tube model. a T-Y tube model was proposed by adding branching tubes whichrepresem the iliac arteries.All the tubes are considered to be uniform,viscoelasticlongitudinally tethered cylindrical tubes.The upper tube terminates with a windkesselmodel, while the terminal arterioles of the lowr tube are expressed as a resistance.After proper eraluation of the parameters.the impedance of the arterial system iscalculated under normal physiological and hypertensive condition.The model canpredict impedance in good agreement with the experimentally obtained data no matterin normal physiological condition or in pathological condition In comparison with theasymmeric T-tube model,T- Y tube model is closer to anatomy structure of the human arlerial system and at the sametime much simpler than the extremely complex multiplebranching tube model Therefore it will be a valuable model in studying the influencesof various parameters on aorta impedance and ventricular-vascular coupling.
文摘Being aimed at the inside wall wrinkling and sinking phenomenon of palladium-yttrium alloy thin wall spiral tube used for preparation of high purity hydrogen, extraction of hydrogen isotope, and purification and separation of hydrogen in the winding process, this article analyzed the reasons for above phenomena, established a numerical simulation model of winding process of above tube, using elastic-plastic Finite Element method analyzed the max. tensile stress and max. compression stress and their locations, thereby provides a theory base for the control of working forming course of thin wall spiral tube.
基金Project(NCET-07-0237)supported by the Program for New Century Excellent Talents in University,ChinaProject(51075100)supported by the National Natural Science Foundation of China