期刊文献+
共找到4,241篇文章
< 1 2 213 >
每页显示 20 50 100
Seismic Behavior of Diaphragm-Through Connections of Concrete-Filled Square Steel Tubular Columns and H-Shaped Steel Beams 被引量:6
1
作者 荣彬 陈志华 +1 位作者 Apostolos Fafitis 苗纪奎 《Transactions of Tianjin University》 EI CAS 2013年第3期195-201,共7页
Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and us... Based on the introductions of a type of diaphragm-through connection between concrete-filled square steel tubular columns (CFSSTCs) and H-shaped steel beams,a finite element model of the connection is developed and used to investigate the seismic behavior of the connection.The results of the finite element model are validated by a set of cyclic loading tests.The cyclic loading tests and the finite element analyses indicate that the failure mode of the suggested connections is plastic hinge at the beam with inelastic rotation angle exceeding 0.04 rad.The suggested connections have sufficient strength,plastic deformation and energy dissipation capacity to be used in composite moment frames as beam-to-column rigid connections. 展开更多
关键词 concrete-filled square STEEL TUBULAR column H-shaped STEEL beam diaphragm-through connection seismic behavior load transfer mechanism
下载PDF
FE modeling of concrete beams and columns reinforced with FRP composites 被引量:4
2
作者 Farid Abed Chahmi Oucif +2 位作者 Yousef Awera Haya H.Mhanna Hakem Alkhraisha 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2021年第1期1-14,共14页
Compression and flexure members such as columns and beams are critical in a structure as its failure could lead to the collapse of the structure.In the present work,numerical analysis of square and circle short column... Compression and flexure members such as columns and beams are critical in a structure as its failure could lead to the collapse of the structure.In the present work,numerical analysis of square and circle short columns,and reinforced concrete(RC)beams reinforced with fiber reinforced polymer composites are carried out.This work is divided into two parts.In the first part,numerical study of axial behavior of square and circular concrete columns reinforced with Glass Fiber Reinforced Polymer(GFRP)and Basalt Fiber Reinforced Polymer(BFRP)bars and spiral,and Carbon Fiber Reinforced Polymer(CFRP)wraps is conducted.The results of the first part showed that the axial capacity of the circular RC columns reinforced with GFRP increases with the increase of the longitudinal reinforcement ratio.In addition,the results of the numerical analysis showed good correlation with the experimental ones.An interaction diagram for BFRP RC columns is also developed with considering various eccentricities.The results of numerical modeling of RC columns strengthened with CFRP wraps revealed that the number and the spacing between the CFRP wraps provide different levels of ductility enhancement to the column.For the cases considered in this study,column with two middle closely spaced CFRP wraps demonstrated the best performance.In the second part of this research,flexural behavior of RC beams reinforced with BFRP,GFRP and CFRP bars is investigated along with validation of the numerical model with the experimental tests.The results resembled the experimental observations that indicate significant effect of the FRP bar diameter and type ont he flexural capacity of the RC beams.It was also shown that Increasing the number of bars while keeping the same reinforcement ratio enhanced the stiffness of the RC beam. 展开更多
关键词 Numerical analysis BRFP GFRP CFRP columnS beamS Experimental tests
下载PDF
基于CTM和Beam-Column Joint Element的梁柱节点核心区抗剪仿真
3
作者 唐智强 黄世涛 马健 《土木工程与管理学报》 北大核心 2020年第3期116-122,共7页
为研究基于CTM和Beam-Column Joint Element单元的钢筋混凝土梁柱节点核心区抗震仿真计算,本文先分析了CTM的计算原理和局限性,并对原计算模型进行调整;之后通过试验数据验证了调整前后模型的正确性,并通过参数分析得出调整前后CTM在不... 为研究基于CTM和Beam-Column Joint Element单元的钢筋混凝土梁柱节点核心区抗震仿真计算,本文先分析了CTM的计算原理和局限性,并对原计算模型进行调整;之后通过试验数据验证了调整前后模型的正确性,并通过参数分析得出调整前后CTM在不同参数下核心区抗剪强度的变化规律;最后通过对比理论计算与试验下核心区抗剪强度变化规律,证明调整后模型更为准确。 展开更多
关键词 钢筋混凝土梁柱节点 CTM 梁柱节点单元 OPENSEES
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
4
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Seismic performance of interior precast concrete beam-column connections with T-section steel inserts under cyclic loading 被引量:15
5
作者 Rattapon Ketiyot Chayanon Hansapinyo 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期355-369,共15页
An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/... An experimental investigation was conducted to study the performance of precast beam-column concrete connections using T-section steel inserts into the concrete beam and joint core,under reversed cyclic loading.Six 2/3-scale interior beam-column subassemblies,one monolithic concrete specimen and five precast concrete specimens were tested.One precast specimen was a simple connection for a gravity load resistant design.Other precast specimens were developed with different attributes to improve their seismic performance.The test results showed that the performance of the monolithic specimen M1 represented ductile seismic behavior.Failure of columns and joints could be prevented,and the failure of the frame occurred at the flexural plastic hinge formation at the beam ends,close to the column faces.For the precast specimens,the splitting crack along the longitudinal lapped splice was a major failure.The precast P5 specimen with double steel T-section inserts showed better seismic performance compared to the other precast models.However,the dowel bars connected to the steel inserts were too short to develop a bond.The design of the precast concrete beams with lap splice is needed for longer lap lengths and should be done at the beam mid span or at the low flexural stress region. 展开更多
关键词 precast concrete beam-column connection cyclic loading
下载PDF
Pushover analysis of reinforced concrete frames considering shear failure at beam-column joints 被引量:4
6
作者 Y.C.Sung T.K.Lin +1 位作者 C.C.Hsiao M.C.Lai 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第3期373-383,共11页
Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the p... Since most current seismic capacity evaluations of reinforced concrete (RC) frame structures are implemented by either static pushover analysis (PA) or dynamic time history analysis, with diverse settings of the plastic hinges (PHs) on such main structural components as columns, beams and walls, the complex behavior of shear failure at beam-column joints (BCJs) during major earthquakes is commonly neglected. This study proposes new nonlinear PA procedures that consider shear failure at BCJs and seek to assess the actual damage to RC structures. Based on the specifications of FEMA-356, a simplified joint model composed of two nonlinear cross struts placed diagonally over the location of the plastic hinge is established, allowing a sophisticated PA to be performed. To verify the validity of this method, the analytical results for the capacity curves and the failure mechanism derived from three different full-size RC frames are compared with the experimental measurements. By considering shear failure at BCJs, the proposed nonlinear analytical procedures can be used to estimate the structural behavior of RC frames, including seismic capacity and the progressive failure sequence of joints, in a precise and effective manner. 展开更多
关键词 RC frame beam-column joint pushover analysis capacity curve plastic hinge performance-based seismic evaluation
下载PDF
New Factor to Characterize Mechanism of “Strong Column-Weak Beam” of RC Frame Structures 被引量:1
7
作者 李心霞 公茂盛 +1 位作者 韩庆华 谢礼立 《Transactions of Tianjin University》 EI CAS 2015年第6期484-491,共8页
Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To ... Most reinforced concrete(RC)frame structures did not achieve the "strong column-weak beam" failure mode in recent big earthquakes, resulting in a large number of casualties and significant property loss. To deal with this serious problem, a new column-beam relative factor was proposed to characterize the relative yield situation of column ends and beam ends. By limiting the column-beam relative factor, RC frame structures could achieve the "strong column-weak beam" failure mode under the excitation of strong ground motions. The limit values of column-beam relative factor were calculated, analyzed and verified by using structural simulation models for corner columns in the bottom story of structures, which are destroyed most seriously in earthquakes. The results show that the limit values should be analyzed under bi-directional ground motion and with different axial compression ratios of columns. The peak ground acceleration(PGA)of ground motions has no significant effect on the limit values, while the type of strong ground motions has a significant effect on the limit values. 展开更多
关键词 RC frame structure strong column-weak beam limit value of column-beam relative factor moment magnification factor at column end
下载PDF
Rapid Repair of Earthquake Damaged RC Interior Beam-wide Column Joints and Beam-wall Joints Using FRP Composites 被引量:1
8
作者 LI Bing LIM Chee Leong 《四川大学学报(工程科学版)》 EI CAS CSCD 北大核心 2009年第3期258-265,共8页
This paper studies the seismic performance of FRP-strengthened RC interior non-seismically detailed beam-wide columns and beam-wall joints after limited seismic damage.Four eccentric and concentric beam-wide column jo... This paper studies the seismic performance of FRP-strengthened RC interior non-seismically detailed beam-wide columns and beam-wall joints after limited seismic damage.Four eccentric and concentric beam-wide column joints and two beam-wall joints,initially damaged in a previous study,were repaired and tested under constant axial loads(0.1fc′Ag and 0.35fc′Ag) and lateral cyclic loading.The rapid repair technique developed,aimed to restore the original strength and to provide minimum drift capacity.The repair schemes were characterized by the use of:(a) epoxy injections and polymer modified cementitious mortar to seal the cracks and replace spalled concrete;and(b) glass(GFRP) and carbon(CFRP) sheets to enhance the joint performance.The FRP sheets were effectively prevented against possible debonding through the use of fiber anchors.Comparison between responses of specimens before and after repair clearly indicated reasonable restoration in strength,drift capacity,stiffness and cumulative energy dissipation capacity.All specimens failed with delamination of FRP sheets at beam-column joint interfaces.The rapid repair technique developed in this study is recommended for mass upgrading or repair of earthquake damaged beam-column joints. 展开更多
关键词 FRP 建筑物 抗震设计 抗震结构
下载PDF
Numerical stress analysis of crack at welded beam-to-column connection
9
作者 姚国春 霍立兴 +2 位作者 张玉凤 荆洪阳 杨新岐 《China Welding》 EI CAS 2000年第2期41-46,共6页
In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers i... In the past, brittle fracture of steel structure was reported rarely under earthquake. However, recent earthquakes, especially Northridge Earthquake (USA) and Hyogoken Nanbu earthquake (Japan), astonished engineers in the field of construction. The experience from recent earthquakes of USA and Japan shows that brittle fracture of welded steel structure always starts from high stress zone with welded crack [1~5] . As backing bar for grooved weld on beam flange exists, artificial crack is formed because of lack of fusion at the root of flange weld. In this paper stress distribution of connection is computed with FEM, and stress concentration at the root of flange weld is also analyzed. Stress intensity factors (SIFs), K I, at the root of flange weld are computed in the method of fracture mechanics. The computation shows that stress intensity factor on bottom flange weld is obviously higher than that on top flange weld. It is proved by the fact that brittle fracture is liable to start at the root of bottom flange weld on actual earthquake [1,4] . Finally measures are brought forward to avoid fracture of weld structure against earthquake. 展开更多
关键词 welded steel structure beam to column connection numerical analysis artificial crack stress intensity factor
下载PDF
Seismic Behavior of Confined RC ColumnComposite Beam Joints
10
作者 张谦 于庆荣 +1 位作者 管俊峰 吴智敏 《Transactions of Tianjin University》 EI CAS 2014年第3期174-181,共8页
In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether... In order to evaluate the seismic behavior of confined RC column-composite beam joints, five interior joints were tested under low cyclic reversed load. The weakening extent of flanges, the number of studs, and whether to reinforce weakened flanges were used as parameters in designing these five joints. Failure characteristics, hysteretic curves, skeleton curves, ductility, energy dissipation, strength degradation, and stiffness degradation were analyzed. The test results revealed that the steel beam flanges in the joints were equivalent to the tie rod. Weakened flanges resulted in poor seismic behavior; however, the seismic behavior could be improved by increasing studs and reinforcing weakened flanges. The joint steel plate hoops, equivalent to stirrups, did not yield when the maximum load was reached, but yielded when the failure load was reached for the joints with shear failure. Increasing stud-type joints and reinforcing flange-type joints ensured good seismic behavior and met project requirements. Based on the experimental results, the failure mechanism of the joints was discussed, and the shear capacity equations of the joints was presented. 展开更多
关键词 seismic behavior JOINT confined RC column composite beam
下载PDF
Numerical Modeling on Seismic Performance of Castellated Composite Beam⁃Reinforced Concrete Column Connection
11
作者 Hongwei Ma Junjie Wang Yang Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2021年第2期62-73,共12页
The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real condition... The hybrid structure consisting of castellated composite beam and compound spiral hoop reinforced concrete column take full advantages of steel and concrete material.To popularize the structural form in real conditions,a beam⁃through⁃type beam⁃column connection is proposed.Two 1/2⁃scaled connection specimens were tested and three⁃dimensional finite element models of the beam⁃column connection were set up.The longitudinal reinforcements,concrete beam,and column were simulated by link and solid elements,respectively.The influences of the parameters such as expansion ratio,location of web opening,and original height of steel beam were studied.The results show that connections possessed high initial rigidity.The expansion ratio of steel beam showed more important influence on the connection’s ultimate bearing capacity.For the connection models with steel beam expansion ratio of 1.4,the maximum increment of the ultimate bearing capacity of the connection could reach 28%.In order to prevent the local buckling failure of steel beam from occurring near web opening,the expansion ratio of steel beam should not be greater than 1.3. 展开更多
关键词 castellated composite beam beamcolumn connection finite element analysis expansion ratio
下载PDF
Seismic Behaviour of Beam-Column Joints of Precast and Partial Steel Reinforced Concrete 被引量:1
12
作者 Wanpeng Cheng Licheng Wang +1 位作者 Yupu Song Jun Wang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第2期108-117,共10页
A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is locate... A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints. 展开更多
关键词 preeast and partial steel reinforced concrete (PPSRC) beam-column joints low cyclic test hysteretic curve degradations of strength and stiffness DUCTILITY
下载PDF
Simulation of high-intense beam transport in electrostatic accelerating column
13
作者 卢小龙 姚泽恩 +6 位作者 张宇 徐大鹏 陈尚文 王俊润 黄智武 马占文 王伟 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期19-24,共6页
An electrostatic accelerating column was designed and fabricated by Lanzhou University for an intense DT/D-D neutron generator. In order to achieve a neutron yield of 5.0 × 10^(12)n/s, a deuteron beam of 30 mA,ac... An electrostatic accelerating column was designed and fabricated by Lanzhou University for an intense DT/D-D neutron generator. In order to achieve a neutron yield of 5.0 × 10^(12)n/s, a deuteron beam of 30 mA,accelerated to 400 kV, and transported in the electrostatic accelerating column smoothly are required. One particle-in-cell code BEAMPATH was used to simulate the beam transport, and the IONB 1.0 code was used to simulate the intense beam envelopes. Emittance growths due to space charge effect and spherical aberration were analyzed. The simulation results show that the accelerating column can transport deuteron beam of 30 mA smoothly and the requirement for the neutron generator is satisfied. 展开更多
关键词 静电加速管 光束传输 粒子模拟 高强度 中子发生器 空间电荷效应 发射度增长 兰州大学
下载PDF
Experimental study on full-scale steel beam-to-column moment connections
14
作者 钱稼茹 余海群 +3 位作者 颜锋 董海 李建华 刘月明 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第2期311-323,共13页
Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one... Ten full-scale steel beam-to-column moment connections used in moment-resisting frames (MRFs) were tested to study the failure process, failure mode, strength and plastic rotation capacity. The specimens include one traditional welded flange-bolted web connection, one traditional fully welded connection, four beam flange strengthened connections, three beam flange weakened connections, and one through-diaphragm connection. The test results show that the connections with flange cover plates or with partly cut beam flanges satisfy the beam plastic rotation demand for ductile MRFs. From the measured stress profiles along the beam flange and beam web depth, the mechanics of brittle fracture at the end of the beam is discussed. Design recommendations for steel beam-to-column moment connections are proposed. 展开更多
关键词 steel beam-to-column moment connection DUCTILITY plastic rotational experiment study
下载PDF
Effects of edge beams on mechanic behavior under lateral load in reinforced concrete hollow slab-column structure
15
作者 成洁筠 杨建军 唐小弟 《Journal of Central South University》 SCIE EI CAS 2008年第S1期61-66,共6页
In order to get the formulae for calculating the equivalent frame width coefficient of reinforced concrete hollow slab-column structures with edge beam,the finite element structural program was used in the elastic ana... In order to get the formulae for calculating the equivalent frame width coefficient of reinforced concrete hollow slab-column structures with edge beam,the finite element structural program was used in the elastic analysis of reinforced concrete hollow slab-column structure with different dimensions to study internal relationship between effective beam width and the frame dimensions.In addition,the formulas for calculating the increasing coefficient of edge beam were also obtained. 展开更多
关键词 reinforced concrete HOLLOW slab-column structure edge beam equivalent frame width COEFFICIENT increasing COEFFICIENT
下载PDF
Analysis of nonlinear stability and post-buckling for Euler-type beam-column structure
16
作者 朱媛媛 胡育佳 程昌钧 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2011年第6期719-728,共10页
Based on the assumption of finite deformation, the Hamilton variational principle is extended to a nonlinear elastic Euler-type beam-column structure located on a nonlinear elastic foundation. The corresponding three-... Based on the assumption of finite deformation, the Hamilton variational principle is extended to a nonlinear elastic Euler-type beam-column structure located on a nonlinear elastic foundation. The corresponding three-dimensional (3D) mathematical model for analyzing the nonlinear mechanical behaviors of structures is established, in which the effects of the rotation inertia and the nonlinearity of material and geometry are considered. As an application, the nonlinear stability and the post-buckling for a linear elastic beam with the equal cross-section located on an elastic foundation are analyzed. One end of the beam is fully fixed, and the other end is partially fixed and subjected to an axial force. A new numerical technique is proposed to calculate the trivial solution, bifurcation points, and bifurcation solutions by the shooting method and the Newton- Raphson iterative method. The first and second bifurcation points and the corresponding bifurcation solutions are calculated successfully. The effects of the foundation resistances and the inertia moments on the bifurcation points are considered. 展开更多
关键词 beam-column structure Hamilton variational principle nonlinear stability shooting method Newton-Raphson iterative method POST-BUCKLING
下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
17
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
下载PDF
Finite Element Modeling of Stability of Beam-Column Supports for Field Fabricated Spherical Storage Pressure Vessels
18
作者 Oludele Adeyefa Oluleke Oluwole 《Engineering(科研)》 2013年第5期475-480,共6页
Spherical pressure vessels in large sizes are generally supported on legs or columns evenly spaced around the circumference. The legs are attached at or near the equator of the sphere. This research work focussed on f... Spherical pressure vessels in large sizes are generally supported on legs or columns evenly spaced around the circumference. The legs are attached at or near the equator of the sphere. This research work focussed on flexural-torsional buckling of beam-column supports of field fabricated spherical pressure vessels using finite element analysis. Flexuraltorsional buckling is an important limit state that must be considered in structural steel design and it occurs when a structural member experiences significant out-of-plane bending and twisting. This research has therefore considered the total potential energy equation for the flexural-torsional buckling of a beam-column element. The energy equation was formulated by summing the strain energy and the potential energy of the external loads. The finite element method was applied in conjunction with the energy method to analyze the flexural-torsional buckling of beam-column supports. To apply the finite element method, the displacement functions are assumed to be cubic polynomials, and the shape functions used to derive the element stiffness and element geometric stiffness matrices. The element stiffness and geometric stiffness matrices were assembled to obtain the global stiffness matrices of the structure. The final finite element equation obtained was in the form of an eigenvalue problem. The flexural-torsional buckling loads of the structure were determined by solving for the eigenvalue of the equation. The resulting eigenvalue equation from the finite element analysis was coded using FORTRAN 90 programming language to aid in the analysis process. To validate FORTRAN 90 coding developed for the finite element analysis and the methodology, the results given by the software were compared to existing solutions and showed no significant difference P > 0.05. 展开更多
关键词 Field-fabricated SPHERICAL STORAGE Pressure TANK beam-column Support FEM
下载PDF
Monotonic and Cyclic Pushover Tests of Wood Beam-Column Connections:Ancient Chinese Tenon Joint vs Typical and Simplified US Connections
19
作者 HUANG Zhenhua 《结构工程师》 2011年第B01期342-349,共8页
Wood beam-column frame is a popular structural system in United States and in ancient China. Chinese wood beam-column frame structures showed better seismic resistance properties than the US ones.The tenon joint is on... Wood beam-column frame is a popular structural system in United States and in ancient China. Chinese wood beam-column frame structures showed better seismic resistance properties than the US ones.The tenon joint is one of the reasons.This study performed monotonic and cyclic pushover tests to understand the behavior of Chinese tenon joints versus the behavior of the commonly used US wood beam-column connections. The test results indicate that the typical US wood beam-column connection is very strong under monotonic loads.The ancient Chinese tenon joint has the best behavior under cyclic loads. 展开更多
关键词 转轮 测试 接缝 转动机件
下载PDF
Seismic Behavor of RC Beam-Column Joint with Additional Bars under Cyclic Loading
20
作者 LU Xilin Tonny H. URUKAP LI Sen 《结构工程师》 2011年第B01期306-312,共7页
The behavior of Beam-Column Joints in moment resisting frame structures are susceptible to damage caused by seismic effects due to poor performance of the joint.A good number of researches were carried out to understa... The behavior of Beam-Column Joints in moment resisting frame structures are susceptible to damage caused by seismic effects due to poor performance of the joint.A good number of researches were carried out to understand the complex mechanism of RC joints which are considered in seismic design code practices presently adopted.The traditional construction detailing of transverse reinforcement have shown serious joint failure. This paper introduces a new design philosophy involving the use of additional diagonal bars within the joint particularly suitable for low to medium seismic effects in earthquake zones throughout the world.In lieu to this study,ten(10) full-scale interior beam-column specimens were constructed with various additional reinforcement details and configurations as will be discussed in the later.The experiment provided adequate results to proof the idea of additional bars as suitable approach in reinforced concrete structures where earthquake is eminent.While compared with overall cracking observation during the test,the specimen with additional bars (diagonal and straight) had shown few cracks on the column than the ones without.Furthermore,concrete confinement is certainly an important design method as recommended by certain international codes. 展开更多
关键词 地震学 理论 方法 地震波
下载PDF
上一页 1 2 213 下一页 到第
使用帮助 返回顶部