Three new hybrid organic/inorganic polymeric ligand-exchange chiral stationary phases were developed by radical chain transfer reaction and surface grafting on silica gel, and successfully used for the enantioseparati...Three new hybrid organic/inorganic polymeric ligand-exchange chiral stationary phases were developed by radical chain transfer reaction and surface grafting on silica gel, and successfully used for the enantioseparations of DL-amino acids and DL-hydroxyl adds. The resolutions were achieved by using water containing 2.0 × 10^-4 mol/L of CuAc2 as a mobile phase, column temperature of 40 ℃, flow rate of 1.0 mL/min and detection at UV 254 nm. The elution order of D-isomer before L-isomer was observed for all DL-amino acids resolved except DL-Pro.展开更多
A novel chiral stationary phase (CSP1) for ligand-exchange chromatography (CLEC) was prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol group on the surface of ...A novel chiral stationary phase (CSP1) for ligand-exchange chromatography (CLEC) was prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol group on the surface of silica gel, and then introducing L-Pro as a chiral selector and hydrophobic octyl group to the silica gel surface simultaneously. The enantioseparations of 14 DL-amino acids on CSP1 were achieved with the enantioselectivity α ranging from 1.09 to 2.44 and the resolution Rs being between 0.8 and 6.3. The chromatographic performances of CSP1 with the bonded phase (CSP2) prepared using reference method were compared. The results showed that the column efficiency and resolution Rs of chiral stationary phase could be improved by using the above modifying method.展开更多
The enantioseparation of dencichine and its D-isomer was achieved on a novel chiral stationary phase via coating N-(2-hydroxyl-3-octoxyl) propyl-S-benzyl-(L)-cysteine on YWG-C18 phase by ligand exchange chromatogr...The enantioseparation of dencichine and its D-isomer was achieved on a novel chiral stationary phase via coating N-(2-hydroxyl-3-octoxyl) propyl-S-benzyl-(L)-cysteine on YWG-C18 phase by ligand exchange chromatography.展开更多
Three chiral stationary phases(CSPl, CSP2 and CSP3) for ligand-exchange chromatography were prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol groups on the surfa...Three chiral stationary phases(CSPl, CSP2 and CSP3) for ligand-exchange chromatography were prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol groups on the surface of silica gel, and then modifying the surface of silica gel with allyl glycidyl ether and alkenes through the hydrosilation reaction, and lastly introducing L-proline as a chiral selector. The enantiomer resolutions of 14 amino acids and 2 hydroxyl acids were completed on the CSPs by using an aqueous solution of Cu(Ac)2 as mobile phase at a flow rate of 1.0 mL/min and column temperature of 40 ℃ with detection at UV 254 nm. In terms of enantioseleetivity a, column efficiency and resolution Rs, the chromatographic behaviors of the analytes on the CSPs were discussed via comparing them to those on the CSP4 prepared via the reference method. The results show that enantioselectivity a, column efficiency and resolution Rs of the analytes on the CSPs could be improved by using the above modifying method.展开更多
Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile ph...Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.展开更多
A simple model of chromatographic mechanical mechanism is present, and then a scrics of theoretical chromatographic equations and fundamental Formulae are derived. These theoretical equations and formulae not only res...A simple model of chromatographic mechanical mechanism is present, and then a scrics of theoretical chromatographic equations and fundamental Formulae are derived. These theoretical equations and formulae not only reserve thermodynamic characteristics in the current fundamental chromatographic formulae, but also introduce one or more kinetic parameter, so it is possible to make the macroscopic-control on the effect of kinetic characteristics on chromatographic system.展开更多
Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three dif...Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three different types of impurities are generally available in the pharmaceutical’s product specification: organic impurities, inorganic impurities, and residual solvents. Residual solvents are organic volatile chemicals used or generated during the manufacturing of drug substances or drug products. Purpose: The aim of this study is to develop a cost-effective gas chromatographic method for the identification and quantification of some commonly used solvents—methanol, acetone, isopropyl alcohol (IPA), methylene chloride, ethyl acetate, tetrahydrofuran (THF), benzene, toluene, and pyridine—in pharmaceutical product manufacturing. This method will be able to identify and quantify the multiple solvents within a single gas chromatographic procedure. Method: A gas chromatography (GC) equipped with a headspace sampler and a flame ionization detector, and a column DB 624, 30-meter-long × 0.32-millimeter internal diameter, 1,8 μm-thick, Brand-Agilent was used to develop this method. The initial GC oven temperature was 40°C and held for 5 minutes. It was then increase to 80˚C at a rate of 2˚C per minute, followed by a further increase to 225˚C at a rate of 30˚C per minute, with a final hold at 225˚C for 10 minutes. Nitrogen was used as a carrier gas at a flow rate of 1.20 mL per minute. Dimethyl sulfoxide (DMSO) was selected as sample solvent. Results: The developed method is precise and specific. The percent RSD for the areas of six replicate injections of this gas chromatographic method was within 10.0 and the recovery result found within 80.0% to 120.0%.展开更多
A method of high-performance liquid chromatography(HPLC)was established for simultaneous determination of 27 preservatives in toothpaste.Toothpaste samples were extracted with 50%aqueous methanol solution,ultrasonicat...A method of high-performance liquid chromatography(HPLC)was established for simultaneous determination of 27 preservatives in toothpaste.Toothpaste samples were extracted with 50%aqueous methanol solution,ultrasonicated and then filtered.The target compounds were separated on a C_(18) column(250 mm×4.6μm,5μm)with the mobile phase consisting of acetonitrile and aqueous phosphoric acid solution,the column temperature was 30℃,the sample volume was 10μL,the flow rate was 1 mL/min,and diode array detector was used.Under the optimal experimental conditions,good linear relationship was obtained and the correlation coefficient(R^(2))was greater than 0.9995.This method was accurate and sensitive,which was suitable for the qualitative and quantitative analysis of 27 preservatives in toothpaste.展开更多
The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar co...The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).展开更多
A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic aci...A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic acid,hydroxyethoxyphenyl butanone,methylisothiazolinone,phenoxyethanol,b e n z oic acid,methylparaben,chlorphenesin,dehydroacetic acid,and 5-bromo-5-nitro-1,3-dioxane)in cosmetics.Different types of samples were ultrasonically extracted by methanol,then the separation of 13 preservatives was carried out on a column of Agilent ZORBAX Eclipse XDB-C18(250 mm×4.6 mm,5μm)by gradient elution at a flow rate of 1.0 mL/min,using 0.1%phosphoric acid solution and acetonitrile as mobile phases.The column temperature was 30℃,and the detection was completed by a diode array detector with the wavelengths at 275,230 and 210 nm.Suspected positive samples were further confirmed by liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry.The linear regression analysis data shows good linearity for 13 preservatives in the respective mass concentration range,with their correlation coefficients(r)greater than 0.9998.The limits of detection(LODs)and limits of quantitation(LOQs)of the method are in the ranges of 0.4-100.0 mg/kg and 1.2-250.0 mg/kg,respectively.At three spiked levels,the average recoveries for 13 target compounds in three kinds of matrix samples are within 84.0%-115.4%,and the relative standard deviations(RSD)are within 0.5%-4.8%(n=6).This method is convenient,efficient,and precise,which can be used for qualitative and quantitative analysis of common preservatives in daily cosmetics.展开更多
[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant propertie...Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.展开更多
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc...In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.展开更多
[Objective] The experiment aimed to study chromatographic fingerprint in volatile components of acacia honey and provide scientific evaluation and effective control on quality of acacia honey.[Method] Using solid-phas...[Objective] The experiment aimed to study chromatographic fingerprint in volatile components of acacia honey and provide scientific evaluation and effective control on quality of acacia honey.[Method] Using solid-phase microextraction method to separate and detect volatile components and construct chromatographic fingerprint.[Result] The honey was preheated for 15 min in water bath at 40 ℃ and solid-phase microextraction 85 μmPA was used to extract in overhead air about 30 min,then put it into the injector and desorpted 3 min,which is in 230 ℃.The Supelco WaxTM10 30 m×0.25 mm×0.25 μm column and gradient heating program was the best method to separate volatile components from honey.83 fingerprint peaks were constructed,among which 17 common fingerprint peaks were comprised of chromatographic fingerprint of volatile components of acacia honey.[Conclusion] The chromatographic fingerprint could provide reference for quality control of acacia honey.展开更多
Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two d...Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations.展开更多
Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on dete...Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on determination of residual protein in lincomycin hydrochloride. Methods The chromatographic conditions were SuperdexTM peptide column, 0.01 mol*L-1 phosphate buffer solution as mobile phase, and flow rate of 1 mL·min-1. Five hundred microliters of lincomycin hydrochloride solution (3 g of lincomycin hydrochloride dissolved in 10 mL of mobile phase) was injected into the chromatograph and the eluted solution was collected between 6 min and 14.5 min (protein eluted from column within this period), and the residual content of total protein in the eluted solution was assayed using Bradford assay method. Results The average recovery was more than 90% for bovine serum albumin, the calibration equation for the range of 0-12 μg·mL-1 of protein was y=-0.002 4x2+0.064 2x+0.002 9, r2=0.999 9, RSD=0.1%-0.9%, and the LOD and LOQ were 3 and 10 ng·mL-1 of protein, respectively. Conclusion The novel method for determining the residual protein in ferment antibio-tics is simple, rapid, and precise.展开更多
[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermente...[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine.展开更多
A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with...A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.展开更多
The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples...The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.展开更多
A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas...A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.展开更多
文摘Three new hybrid organic/inorganic polymeric ligand-exchange chiral stationary phases were developed by radical chain transfer reaction and surface grafting on silica gel, and successfully used for the enantioseparations of DL-amino acids and DL-hydroxyl adds. The resolutions were achieved by using water containing 2.0 × 10^-4 mol/L of CuAc2 as a mobile phase, column temperature of 40 ℃, flow rate of 1.0 mL/min and detection at UV 254 nm. The elution order of D-isomer before L-isomer was observed for all DL-amino acids resolved except DL-Pro.
文摘A novel chiral stationary phase (CSP1) for ligand-exchange chromatography (CLEC) was prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol group on the surface of silica gel, and then introducing L-Pro as a chiral selector and hydrophobic octyl group to the silica gel surface simultaneously. The enantioseparations of 14 DL-amino acids on CSP1 were achieved with the enantioselectivity α ranging from 1.09 to 2.44 and the resolution Rs being between 0.8 and 6.3. The chromatographic performances of CSP1 with the bonded phase (CSP2) prepared using reference method were compared. The results showed that the column efficiency and resolution Rs of chiral stationary phase could be improved by using the above modifying method.
文摘The enantioseparation of dencichine and its D-isomer was achieved on a novel chiral stationary phase via coating N-(2-hydroxyl-3-octoxyl) propyl-S-benzyl-(L)-cysteine on YWG-C18 phase by ligand exchange chromatography.
文摘Three chiral stationary phases(CSPl, CSP2 and CSP3) for ligand-exchange chromatography were prepared by firstly using dimethylchlorosilane as an endcapping reagent for decreasing residual silanol groups on the surface of silica gel, and then modifying the surface of silica gel with allyl glycidyl ether and alkenes through the hydrosilation reaction, and lastly introducing L-proline as a chiral selector. The enantiomer resolutions of 14 amino acids and 2 hydroxyl acids were completed on the CSPs by using an aqueous solution of Cu(Ac)2 as mobile phase at a flow rate of 1.0 mL/min and column temperature of 40 ℃ with detection at UV 254 nm. In terms of enantioseleetivity a, column efficiency and resolution Rs, the chromatographic behaviors of the analytes on the CSPs were discussed via comparing them to those on the CSP4 prepared via the reference method. The results show that enantioselectivity a, column efficiency and resolution Rs of the analytes on the CSPs could be improved by using the above modifying method.
文摘Methods for determining nine low molecular weight organic acids in root exudates were developed by using reversed phase high performance liquid chromatography with UV (ultraviolet) detection at 214 nm. The mobile phase was 18 mmol L -1 kH 2PO 4 adjusted to pH 2.25 with phosphoric acid and the flow rate was 0.3 mL min -1 . The analytical column was a reversed phase silica based C 18 column (Shim pack CLC ODS). The root exudates were collected through submerging the whole root system into aerated deionized water for 2 hours. The filtered exudate solutions were concentrated to dryness by rotary evaporation at 40 °C, dissolved in 10 mL mobile phase. The chromatographic conditions of organic acid determination were analyzed. The results showed that there was a high selectivity and sensitivity in the organic acid determination by reversed phase high performance liquid chromatography. Coefficients of variation for organic acid determination were lower than 10% except lactic acid. The recoveries were consistently between 80.1% to 108.3%. Detection limits were approximately 0.05 to 4.5 mg L -1 for organic acids except succinic acid with the detection limit of 7.0 mg L -1 . Phosphorus deficiency may contribute to the release of organic acids in soybean root exudates especially malic, lactic and citric acids.
文摘A simple model of chromatographic mechanical mechanism is present, and then a scrics of theoretical chromatographic equations and fundamental Formulae are derived. These theoretical equations and formulae not only reserve thermodynamic characteristics in the current fundamental chromatographic formulae, but also introduce one or more kinetic parameter, so it is possible to make the macroscopic-control on the effect of kinetic characteristics on chromatographic system.
文摘Background: Impurities are not expected in the final pharmaceutical products. All impurities should be regulated in both drug substances and drug products in accordance with pharmacopeias and ICH guidelines. Three different types of impurities are generally available in the pharmaceutical’s product specification: organic impurities, inorganic impurities, and residual solvents. Residual solvents are organic volatile chemicals used or generated during the manufacturing of drug substances or drug products. Purpose: The aim of this study is to develop a cost-effective gas chromatographic method for the identification and quantification of some commonly used solvents—methanol, acetone, isopropyl alcohol (IPA), methylene chloride, ethyl acetate, tetrahydrofuran (THF), benzene, toluene, and pyridine—in pharmaceutical product manufacturing. This method will be able to identify and quantify the multiple solvents within a single gas chromatographic procedure. Method: A gas chromatography (GC) equipped with a headspace sampler and a flame ionization detector, and a column DB 624, 30-meter-long × 0.32-millimeter internal diameter, 1,8 μm-thick, Brand-Agilent was used to develop this method. The initial GC oven temperature was 40°C and held for 5 minutes. It was then increase to 80˚C at a rate of 2˚C per minute, followed by a further increase to 225˚C at a rate of 30˚C per minute, with a final hold at 225˚C for 10 minutes. Nitrogen was used as a carrier gas at a flow rate of 1.20 mL per minute. Dimethyl sulfoxide (DMSO) was selected as sample solvent. Results: The developed method is precise and specific. The percent RSD for the areas of six replicate injections of this gas chromatographic method was within 10.0 and the recovery result found within 80.0% to 120.0%.
文摘A method of high-performance liquid chromatography(HPLC)was established for simultaneous determination of 27 preservatives in toothpaste.Toothpaste samples were extracted with 50%aqueous methanol solution,ultrasonicated and then filtered.The target compounds were separated on a C_(18) column(250 mm×4.6μm,5μm)with the mobile phase consisting of acetonitrile and aqueous phosphoric acid solution,the column temperature was 30℃,the sample volume was 10μL,the flow rate was 1 mL/min,and diode array detector was used.Under the optimal experimental conditions,good linear relationship was obtained and the correlation coefficient(R^(2))was greater than 0.9995.This method was accurate and sensitive,which was suitable for the qualitative and quantitative analysis of 27 preservatives in toothpaste.
基金supported by the National Natural Science Foundation of China(22078281)。
文摘The isolation of minor components from complex natural product matrices presents a significant challenge in the field of purification science due to their low concentrations and the presence of structurally similar compounds.This study introduces an optimized twin-column recycling chromatography method for the efficient and simultaneous purification of these elusive constituents.By introducing water at a small flowing rate between the twin columns,a step solvent gradient is created,by which the leading edge of concentration band would migrate at a slower rate than the trailing edge as it flowing from the upstream to downstream column.Hence,the band broadening is counterbalanced,resulting in an enrichment effect for those minor components in separation process.Herein,two target substances,which showed similar peak position in high performance liquid chromatography(HPLC)and did not exceed 1.8%in crude paclitaxel were selected as target compounds for separation.By using the twin-column recycling chromatography with a step solvent gradient,a successful purification was achieved in getting the two with the purity almost 100%.We suggest this method is suitable for the separation of most components in natural produces,which shows higher precision and recovery rate compared with the common lab-operated separation ways for natural products(thin-layer chromatography and prep-HPLC).
文摘A method using high performance liquid chromatography(HPLC)was developed for the s imultaneous determination of 13 preservatives(levulinic acid,p-hydroxyacetophenone,raspberry ketone,p-anisic acid,caprylhydroxamic acid,hydroxyethoxyphenyl butanone,methylisothiazolinone,phenoxyethanol,b e n z oic acid,methylparaben,chlorphenesin,dehydroacetic acid,and 5-bromo-5-nitro-1,3-dioxane)in cosmetics.Different types of samples were ultrasonically extracted by methanol,then the separation of 13 preservatives was carried out on a column of Agilent ZORBAX Eclipse XDB-C18(250 mm×4.6 mm,5μm)by gradient elution at a flow rate of 1.0 mL/min,using 0.1%phosphoric acid solution and acetonitrile as mobile phases.The column temperature was 30℃,and the detection was completed by a diode array detector with the wavelengths at 275,230 and 210 nm.Suspected positive samples were further confirmed by liquid chromatography-tandem mass spectrometry or gas chromatography-mass spectrometry.The linear regression analysis data shows good linearity for 13 preservatives in the respective mass concentration range,with their correlation coefficients(r)greater than 0.9998.The limits of detection(LODs)and limits of quantitation(LOQs)of the method are in the ranges of 0.4-100.0 mg/kg and 1.2-250.0 mg/kg,respectively.At three spiked levels,the average recoveries for 13 target compounds in three kinds of matrix samples are within 84.0%-115.4%,and the relative standard deviations(RSD)are within 0.5%-4.8%(n=6).This method is convenient,efficient,and precise,which can be used for qualitative and quantitative analysis of common preservatives in daily cosmetics.
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
文摘Recent studies have highlighted the potential of plant extracts as therapeutic agents for managing oxidative stress and related disorders.This study aims to elucidate the phenolic composition and antioxidant properties of Gymnema sylvestre extracts.Ethanolic reflux extraction followed by column chromatography was employed to isolate phenolic compounds.The total phenolic and flavonoid contents were quantified using the Folin–Ciocalteu and aluminum chloride colorimetric methods,respectively.Antioxidant activities were assessed by DPPH,ABTS scavenging assays and the ferric reducing antioxidant power(FRAP)assay.High-Performance Liquid Chromatography(HPLC)with a C18 column and Thermo TSQ Quantum Access Max(LC-MS)were used to determine the levels of gymnemic acid and identify other potential phenolic compounds.The analysis revealed significant antioxidant activities in the fractions.Fraction A showed the highest DPPH and ABTS scavenging activities,and Fraction C demonstrated the highest ferric reducing power.LC-MS analysis identified several phenolic compounds,indicating that these are major contributors to the antioxidant efficacy of the extract.This study provides a detailed phenolic profile and confirms the strong antioxidant potential of Gymnema sylvestre leaf extract,supporting its therapeutic use and further investigation.
文摘In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil.
基金Support by Department of Education Science and Technology Research Projects of Hebei Province(2008310)the National Special Fund for the Commonweal Industry(200810345)~~
文摘[Objective] The experiment aimed to study chromatographic fingerprint in volatile components of acacia honey and provide scientific evaluation and effective control on quality of acacia honey.[Method] Using solid-phase microextraction method to separate and detect volatile components and construct chromatographic fingerprint.[Result] The honey was preheated for 15 min in water bath at 40 ℃ and solid-phase microextraction 85 μmPA was used to extract in overhead air about 30 min,then put it into the injector and desorpted 3 min,which is in 230 ℃.The Supelco WaxTM10 30 m×0.25 mm×0.25 μm column and gradient heating program was the best method to separate volatile components from honey.83 fingerprint peaks were constructed,among which 17 common fingerprint peaks were comprised of chromatographic fingerprint of volatile components of acacia honey.[Conclusion] The chromatographic fingerprint could provide reference for quality control of acacia honey.
文摘Aim To establish a reversed-phase liquid chromatographic (LC) method forsimultaneous determination of tetramethylpyrazine (TMP) and aspirin in a new compound formulation.Methods Chromatographic separation of the two drugs was achieved on a Diamonsil C_(18) column, usinga binary mixture of methanol-1.5% acetic acid (35:65, V/V, pH = 3.1) as mobile phase at a flow rateof 1.0 mL·min^(-1). Results Separation was completed in less than 12 min. Benzoic acid was used asthe internal standard. Recoveries at levels corresponding to 80 % to 120 % of the label claim ofthe formulation ranged from 99.6 to 100.3 % for aspirin and from 99.9 to 101.3% for TMP. The linearrange was 12.6 - 150.9 μg·mL^(-1)(r= 0.9997, n = 5) for aspirin and 25.0- 300.0 μg·mL^(-1) (r =0.9999, n = 5) for TMP. Conclusion The method developed can be used for the simultaneousdetermination of TMP and aspirin in pharmaceutical preparations.
文摘Aim A novel method has been developed for evaluation of the levels of total residual protein in antibiotics produced by fermentation using gel filtration chromatography (GFC) combined with Bradford assay based on determination of residual protein in lincomycin hydrochloride. Methods The chromatographic conditions were SuperdexTM peptide column, 0.01 mol*L-1 phosphate buffer solution as mobile phase, and flow rate of 1 mL·min-1. Five hundred microliters of lincomycin hydrochloride solution (3 g of lincomycin hydrochloride dissolved in 10 mL of mobile phase) was injected into the chromatograph and the eluted solution was collected between 6 min and 14.5 min (protein eluted from column within this period), and the residual content of total protein in the eluted solution was assayed using Bradford assay method. Results The average recovery was more than 90% for bovine serum albumin, the calibration equation for the range of 0-12 μg·mL-1 of protein was y=-0.002 4x2+0.064 2x+0.002 9, r2=0.999 9, RSD=0.1%-0.9%, and the LOD and LOQ were 3 and 10 ng·mL-1 of protein, respectively. Conclusion The novel method for determining the residual protein in ferment antibio-tics is simple, rapid, and precise.
基金Supported by Changsha Key Project in Hunan Province(K1005007-21)~~
文摘[Objective] The aim was to analyze sugar components in fermented rice wine by ion chromatography. [Method] The optimal condition for chromatography system of sugar analysis was selected by measuring sugars in fermented rice wine with ion chromatography and pulsed amperometric detection. [Result] The optimal measurement conditions were as follows: Leacheate (Leachate), consisting of NaOH and CH3COONa, was eluted by gradient concentrations, with column temperature at 35 ℃ and flow rate at 0.4 ml/min. In the condition, sugars in rice wine were ana- lyzed and the results showed that the method is featured by low detection limit, good repetition and high recovery rate. [Conclusion] The research establishes and determines the approaches and optimum conditions for sugar analysis in rice wine by ion chromatography and pulsed amperometric detection, providing references for advancement of research on quality improvement of fermented rice wine.
文摘A method for the determination of dichlofluanid residue by Capillary Collumns Gas Chromatography was established in this study.Samples were extracted with acetone and subjected to through liquid-liquid extraction with N-hexane,and then they were cleanup with column that filled with florisil,subsequently separated by Capillary Column Gas Chromatography,and the electron capture detector (ECD) was used for detection.The detection limit of this method was 0.005 mg/kg (S/N=3),and this method was rapid,sensitive and accurate,and was applied in the determination of dichlofluanid residue in soybean.
文摘The combination of pyrolysis high resolution gas chromatography and pat- tern recognition techniques is a powerful tool for the classification of traditional Chinese drug.A study has been completed on 55 Beimu samples of five different geographic origins: Eastern China.Central China.South-western China,North-western China and North-eastern China.Principal component analysis and SIMCA are applied to effectively classifying the samples according to the origin of the plants.The chemical information contained in the high resolution gas chromatographic data is sufficient to characterize the geographic origin of sam- pies.
基金The National Basic Research Program of China(973Program)(No.2012CB933302)the National Instrumental Research Program(No.2014YQ06077303)+1 种基金the National Natural Science Foundation of China(No.81172720,21307086)Suzhou Science and Technology Department Foundation(No.ZXG201441)
文摘A new method for simultaneous determination of four phthalate esters ( PAEs) in commercial fat-containing foods was developed by the combination of a packed nanofibers column based on solid-phase extraction with gas chromatography-flame ionization detector ( GC-FID ). Conditions for obtaining optimum extraction efficiency such as extraction solvents, morphologies of adsorbent, ion strength and pH were investigated and optimized in detail. Under the optimized conditions, the limits of detection (LODs) found for dibutyl phthalate (DBP) , butyl benzyl phthalate (BBP), diethyl hexyl phthalate (DEHP) and di-n-octyl phthalate (DNOP) were 50, 25, 50 and 25 ng/g, respectively. Good linearity of four PAEs was achieved in the range of 50 to 4 000 ng/g. The proposed method was applied for analyzing different kinds of fat-containing samples. PAEs in commercial fat-containing samples can be highly extracted by a packed solid-phase extraction column of 5 mg polystyrene ( PS) nanofibers. The satisfactory average recoveries were obtained in the range of 96. 7% to 102. 3% , and the relative standard deviations (RSDs) below 5% were achieved. The proposed method reduces the organic solvent consumption, the complex and tedious procedures for sample pretreatment, and achieves high sensitivity and reproducibility for the investigated PAEs.