期刊文献+
共找到13篇文章
< 1 >
每页显示 20 50 100
《变频调速》一体化课程探究
1
作者 龙浔 《知识窗(教师版)》 2018年第18期45-45,共1页
本文探究了《变频调速》一体化课程,阐述了一体化教学模式的特点,实施一体化教学的必要条件,并介绍了一体化教学与理论教学的不同,以及一体化教学存在的问题及解决办法,从而归纳总结了一体化课程改革的几点经验。
关键词 《变频调速》 一体化课程
原文传递
IMPROVEMENT IN WAVEFORM OF SWITCHING POINT-PRESET SPWM INVERTERS
2
作者 谢少军 裘卫红 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1995年第1期72-79,共8页
Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width mo... Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width modulation (SPWM) inverters with low harmonyic content in theory.The THD value would be increased by switching time delay of power devices and control circuit. A new control coecuit with delay time compensation is presented in this paper. With this control scheme, the output of the inverter could be basically identified with the theory given.Test results of experimental circuit verify that the control circuit presented in this paper is feasible. The THD of the inverter output voltage could be reduced to a certain extent by this method. 展开更多
关键词 INVERTERS pulse width modulation variable speed constant frequency (VSCF) total harmonic distortion switching-point-preset
下载PDF
Stability of Oil Film and Output Speed of Hydroviscous Drive Affected by the Pressure of Control Oil 被引量:4
3
作者 黄晓光 魏宸官 《Journal of Beijing Institute of Technology》 EI CAS 2001年第3期266-271,共6页
Based on the theories of hydraulics and nonlinear control system, the model of hydroviscous drive (HVD) was established, the influences of small ripple of control oil pressure on the output speed of HVD and the stabil... Based on the theories of hydraulics and nonlinear control system, the model of hydroviscous drive (HVD) was established, the influences of small ripple of control oil pressure on the output speed of HVD and the stability of oil film between friction disks were analyzed. The conclusion presents that when the frequency of the control oil's pressure ripple is higher than 60?Hz and the peak is less than 0 05?MPa, HVD can work stably. The result is useful for studying the application of frequency conversion technology in regulation of control oil pressure. 展开更多
关键词 hydroviscous drive frequency conversion nonlinear system
下载PDF
The cycloconverter based on fuzzy controller for lift 被引量:1
4
作者 王根平 易灵芝 《Journal of Coal Science & Engineering(China)》 2005年第2期95-98,共4页
In order to ensure the lift can go up and down steadily and safely, a cycloconverter based on fuzzy control algorithm for lift was introduced, which can keep the output voltage to be symmetric sine wave. In this cyclo... In order to ensure the lift can go up and down steadily and safely, a cycloconverter based on fuzzy control algorithm for lift was introduced, which can keep the output voltage to be symmetric sine wave. In this cycloconverter system, the main circuit structure was designed as circumfluence mode, with the strong DSP as the control unit, the fuzzy control policy of average weight accumulation decision was used to control the tuning of the triggering angle for thyristor in the main circuit, and then, the output voltage of the cycloconverter can be controlled. The experiment and simula-tion prove that the performance of the fuzzy cycloconverter is improved a lot and the output voltage is very similar to symmetric sine wave. This kind of cycloconverter can help the lift stop accurately, and the shock can be decreased. 展开更多
关键词 fuzzy control CYCLOCONVERTER LIFT
下载PDF
Development of belt conveyor driving system 被引量:1
5
作者 付峻青 王聪 霍伟 《Journal of Coal Science & Engineering(China)》 2004年第1期83-87,共5页
A short review for the existing various driving methods for belt conveyor was given, which include the analysis and comparison about the advantages, disadvantages and suitable application range of these methods. Based... A short review for the existing various driving methods for belt conveyor was given, which include the analysis and comparison about the advantages, disadvantages and suitable application range of these methods. Based on this the vari-able-frequency-control(VFC) method for belt conveyor drive was fully discussed with focus on its application in medium-high voltage range. The principle of Neutral Point Clamped (NPC) Three-Level Inverter using high-voltage IGBTs together with the control strategy of rotor field-oriented vector control for induction motor drive were illustrated. 展开更多
关键词 belt conveyor driving system variable-frequency-control three-level inverter
下载PDF
Research on the variable speed system of large power alternating current motor 被引量:1
6
作者 Li Chongjian 《Engineering Sciences》 EI 2012年第1期30-37,共8页
The development status of the variable speed system of large power AC(alternating current)motor drive in China is introduced.The large power AC drive fed by AC-AC converters(cycloconverters)has developed greatly,and s... The development status of the variable speed system of large power AC(alternating current)motor drive in China is introduced.The large power AC drive fed by AC-AC converters(cycloconverters)has developed greatly,and some innovations on the theory and engineering technique have been realized.They have been applied to rolling mills,mine hoists,and so on,and remarkable economic and social benefit has been achieved.The development of AC drive fed by large power IGCT(integrated gate commutated thyristors)AC-DC-AC converter is also introduced.It has excellent performance and reliable operation,and has been used in traction. 展开更多
关键词 large power AC motor CYCLOCONVERTER AC-DC-AC converter IGCT
下载PDF
The performance analysis and calculation for variable frequency speed control motors with the rotor structure optimized
7
作者 曹君慈 李伟力 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第6期710-714,共5页
In the paper, the method to optimize the rotor structure in variable frequency speed control motors is introduced. The saturation and the skin effect are considered and 2D no-load and load electromagnetic field is cal... In the paper, the method to optimize the rotor structure in variable frequency speed control motors is introduced. The saturation and the skin effect are considered and 2D no-load and load electromagnetic field is calculated in finite elements for a variable frequency speed control motor before and after optimization. Finally, no-load current and operation performance before and after optimization are obtained and the two results are contrasted. 展开更多
关键词 variable frequency speed control optimization design finite element operation performance
下载PDF
Research on variable frequency and speed regulation of motor system based on PLC
8
作者 Min ZHENG 《International Journal of Technology Management》 2015年第2期41-43,共3页
This paper presents the composition, control scheme and signal processing method of frequency conversion motor speed testing system based on $7-200 PLC, and design the hardware circuit, the trapezoidal chart procedure... This paper presents the composition, control scheme and signal processing method of frequency conversion motor speed testing system based on $7-200 PLC, and design the hardware circuit, the trapezoidal chart procedure and touch screen display program. The debugging test shows that the system is simple, practical, and related design work has laid the foundation for the future. 展开更多
关键词 INVERTER frequency control touch screen $7-200 PLC PID
下载PDF
The feasibility experimental study of pumping and shunting pump under pressure in water injection station
9
作者 Dongbo SHAO Yong WANG Suiwang ZHANG 《International Journal of Technology Management》 2013年第3期34-37,共4页
At present in the process of water injection station operation, starting and stopping the pump caused system pressure fluctuations, and the fluctuations caused many problems about downstream injection wells. In order ... At present in the process of water injection station operation, starting and stopping the pump caused system pressure fluctuations, and the fluctuations caused many problems about downstream injection wells. In order to eliminate the fluctuations and reduce problems, taking start pump, connect pump test under pressure in the water injection station installed the rotor frequency control system Changqing oil field developed. During the experiment, by progressively increasing the pressure pump to verify start pump with pressure feasibility test, the result shows when the pressure in the 0-25MPa pressure start and connect pump can be realized, and forecast the maximum pressure of the current start of the station with pressure pump. Start pump with pressure achieve the elimination of pressure fluctuations, provide the prerequisites about realizeing stable water injection pressure, and ultimately realize oil field water injection station to be automatic water injection laid a foundation. 展开更多
关键词 water injection station wire-wound motor pumping pump under pressure feasibility experiment
下载PDF
The Applications of High-voltage variable frequency speed regulation System in Main Exhauster of Sintering
10
作者 Li Jingwei 《International English Education Research》 2015年第9期8-10,共3页
Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the pro... Main Exhauster is one of the main equipment of sintering production. It needs to consume a lot of electricity. Therefore, the system' s reconstruction for energy-saving will effectively reduce electricity for the production. The paper takes an iron and steel enterprise that had successfully transformed the synchronous motors of main exhauster of sintering as an example, which describes the application of high-voltage variable frequency speed regulation system in main exhauster of Sintering, so as to provide a reference for other iron and steel enterprises. 展开更多
关键词 High-voltage variable frequency speed regulation SINTERING main exhauster.
下载PDF
Microcontroller-Based Variable Speed Drive for Three-Phase Induction Motor in Cooling Applications
11
作者 Kondapalli Siva Rama Rao Lee Teng Hong 《Journal of Energy and Power Engineering》 2012年第4期656-662,共7页
This paper presents an electronic VSD (variable speed drive) for three-phase IM (induction motor) using a microcontroller. The VSD is designed for cooling applications where the 1M is coupled to a cooling fan. The... This paper presents an electronic VSD (variable speed drive) for three-phase IM (induction motor) using a microcontroller. The VSD is designed for cooling applications where the 1M is coupled to a cooling fan. The drive receives temperature feedback from objects to be cooled and output a corresponding frequency to the IM. A prototype of the VSD is constructed to control a 175 W, four pole, squirrel cage three-phase IM. The heart of the control circuit is a low-cost microchip's PICI6F777 microcontroller which is programmed using C language to generate variable frequency SPWM (sinusoidal pulse width modulation) switching signals. These switching signals are fed to an 1GBT inverter. The VSD constructed can be switched between two modes of speed control" automatic temperature-controlled mode and manual user-controlled mode. Cost savings using the prototype are demonstrated. 展开更多
关键词 IGBT inverter PIC microcontroller SPWM three-phase induction motor variable speed drive.
下载PDF
"One-for-several" rotor VVVF Technique apply to water injection station
12
作者 Yanrong CHANG Shouhu WANG Ruxian HE 《International Journal of Technology Management》 2013年第3期38-41,共4页
In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displa... In the process of oilfield water injection volume of injection allocation often appear with the pump displacement situation does not match, the widespread adoption of stator frequency technology allows the pump displacement and volume of injection allocation phase matching. But the technology in pump class load application speed range is limited, there is still a reflux valve control blind area," turn off undead" problem. " One-for-several" rotor frequency Technique in water injection station application, solved the control blind area problem, the full realization of the variable frequency close return voltage injection, at the same time, the successful implementation of the slip power efficient feedback. Stable water injection pressure of the system, and the electric energy is saved, satisfy the oilfield high efficiency, fine water needs, has a high application value. 展开更多
关键词 "One-for-several" rotor frequency Variable frequency speed regulation Stable pressure water injection Energy saving
下载PDF
Transfer efficiency optimal control of magnetic resonance coupled system of wireless power transfer based on frequency control 被引量:41
13
作者 TAN LinLin HUANG XueLiang +2 位作者 HUANG Hui ZOU YuWei LI Hui 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第6期1428-1434,共7页
In order to suppress the fast decrease of the transfer efficiency of magnetic resonance coupled wireless power transfer system(MRCWPTS) with distance increase,this paper investigates the impact factors of the system t... In order to suppress the fast decrease of the transfer efficiency of magnetic resonance coupled wireless power transfer system(MRCWPTS) with distance increase,this paper investigates the impact factors of the system transfer efficiency and is,then formulates a new efficiency optimal control method based on frequency control.Based upon this control method two optimal control schemes are designed to achieve transfer efficiency control of the system.Simulations and experiments show that the proposed efficiency optimal control method can effectively stabilize the system transfer efficiency in a certain range so as to successfully solve the subtle issue of transfer efficiency variation with distance. 展开更多
关键词 magnetic coupling frequency control efficiency optimal wireless power transfer
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部