This study is aimed to investigate the clinical significance and the short-term prognostic value of frag- mented QRS (fQRS) for patients with acute myocardial infarction (AMI). Three hundred patients with AMI were...This study is aimed to investigate the clinical significance and the short-term prognostic value of frag- mented QRS (fQRS) for patients with acute myocardial infarction (AMI). Three hundred patients with AMI were tested with retrospective analysis on the patients' clinical information, hospitalized treatment, fQRS onset time, location of lesions, and other relevant data, in order to assess the relationship between the presence of fQRS and its prognosis. The rates of malignant cardiac arrhythmia, left ventricular systolic dysfunction (LVSD), and mortality in the positive fQRS group were 13.6%, 29.2%, and 23.7%, respectively, with all showing a p value 〈0.05. For the ST segment elevation myocardial infarction (STEMI) subgroup, all the rates showed significant differences with a p value 〈0.01, while for the non-STEMI (NSTEMI) subgroup showed no significant differences. In patients with a positive fQRS, there were no differences in malignant cardiac arrhythmia between patients with and without percutaneous coronary in- tervention (PCI) (p〉0.05). As for the LVSD and mortality, the p values between patients with and without PCI were 0.031 and 0.000, respectively, suggesting statistical significance. The results imply that AMI patients with positive fQRS especially for the patients with STEMI had higher rates of malignant cardiac arrhythmia, LVSD, and mortality than the non-fQRS group. Patients of AMI with positive fQRS, who underwent early revascularization, could lower the incidence of the cardiovascular event. In addition, the presence of fQRS could be used as an indication of early in- tervention treatment for patients.展开更多
Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS). Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of ...Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS). Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of a 54-year-old male patient who sustained Garden type IV frac- ture of the right femoral neck. The distal end of the guide wire broke and was entrapped in the fractured femoral neck. We tried to get the broken part out by a cannulated drill. Reaming was started with the cannulated drill slowly rotat- ing arotmd the guide K-wire until the reamer fully contained the target under fluoroscope. A bone curette was used to get the broken wire out but failed, so we had to use the cannuated drill to dredge this bone tunnel. Finally the bro-ken wire end was taken out, mixed with blood and bone fragments. Through the existing drilling channel, DHS fixa- tion was easily finished. The patient had an uneventful re- covery without avascular necrosis of femoral head or non- union of the fracture at one year's follow-up. A few methods can be adopted to deal with the broken guide wire. The way used in our case is less invasive but technically challenging. When the guide wire is properly positioned, this method is very practical and useful.展开更多
基金Project supported by the National Science & Technology Pillar Program during the 12th Five-Year Plan Period(No.2011BAI11B06),China
文摘This study is aimed to investigate the clinical significance and the short-term prognostic value of frag- mented QRS (fQRS) for patients with acute myocardial infarction (AMI). Three hundred patients with AMI were tested with retrospective analysis on the patients' clinical information, hospitalized treatment, fQRS onset time, location of lesions, and other relevant data, in order to assess the relationship between the presence of fQRS and its prognosis. The rates of malignant cardiac arrhythmia, left ventricular systolic dysfunction (LVSD), and mortality in the positive fQRS group were 13.6%, 29.2%, and 23.7%, respectively, with all showing a p value 〈0.05. For the ST segment elevation myocardial infarction (STEMI) subgroup, all the rates showed significant differences with a p value 〈0.01, while for the non-STEMI (NSTEMI) subgroup showed no significant differences. In patients with a positive fQRS, there were no differences in malignant cardiac arrhythmia between patients with and without percutaneous coronary in- tervention (PCI) (p〉0.05). As for the LVSD and mortality, the p values between patients with and without PCI were 0.031 and 0.000, respectively, suggesting statistical significance. The results imply that AMI patients with positive fQRS especially for the patients with STEMI had higher rates of malignant cardiac arrhythmia, LVSD, and mortality than the non-fQRS group. Patients of AMI with positive fQRS, who underwent early revascularization, could lower the incidence of the cardiovascular event. In addition, the presence of fQRS could be used as an indication of early in- tervention treatment for patients.
文摘Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS). Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of a 54-year-old male patient who sustained Garden type IV frac- ture of the right femoral neck. The distal end of the guide wire broke and was entrapped in the fractured femoral neck. We tried to get the broken part out by a cannulated drill. Reaming was started with the cannulated drill slowly rotat- ing arotmd the guide K-wire until the reamer fully contained the target under fluoroscope. A bone curette was used to get the broken wire out but failed, so we had to use the cannuated drill to dredge this bone tunnel. Finally the bro-ken wire end was taken out, mixed with blood and bone fragments. Through the existing drilling channel, DHS fixa- tion was easily finished. The patient had an uneventful re- covery without avascular necrosis of femoral head or non- union of the fracture at one year's follow-up. A few methods can be adopted to deal with the broken guide wire. The way used in our case is less invasive but technically challenging. When the guide wire is properly positioned, this method is very practical and useful.