[ Objective] The aim was to establish the method of extracting genomic DNA from sheep blood clot on the basis of the improvement of method for extracting genomic DNA from tissues. [Method]The genomic DNA with complete...[ Objective] The aim was to establish the method of extracting genomic DNA from sheep blood clot on the basis of the improvement of method for extracting genomic DNA from tissues. [Method]The genomic DNA with complete primary structure and high purity was obtained from the sheep blood clot after the steps of cutting the sheep blood clot with ophthalmic scissors, cell lysis with tissue DNA extracts and digested by proteinase K, extracting with phenol/chloroform and precipitating with ethanol were performed. [ Result] The concentration of the extracted DNA was 159.90 ±0.70 ng/μl and the ratio of the A260/A280 was 1.80 +0.01. The sheep microsatellite locus of BM203 was amplified by using the extracted DNA from the sheep blood clot as template of PCR, and the PCR result was perfect. [Conclusion]This method is simple and feasible, the quantity and quality of the extracted DNA can satisfy the demands for the subsequent researches. It is worth to extending and using for reference.展开更多
Background The clinical efficacy and safety of adjunctive thrombus aspiration (TA) in patients with ST-segment elevation myocardial infarction (STEMI) during percutaneous coronary intervention (PCI) remain contr...Background The clinical efficacy and safety of adjunctive thrombus aspiration (TA) in patients with ST-segment elevation myocardial infarction (STEMI) during percutaneous coronary intervention (PCI) remain controversial. Methods Twenty five eligible randomized controlled trials were included to compare the use of thrombus aspiration (TA) with PCI and PCI-only for STEMI. The primary endpoint was all-cause mortality and death. The secondary endpoints were major adverse cardiac events (MACE), recurrent infarction (RI), target vessel revascularization (TVR), stent thrombosis (ST), perfusion surrogate markers and stroke. Results TIMI flow grade 3 and MBG 2-3 were significantly increased in the TA plus PCI arm compared with the PCI-only arm [relative risk (RR): 1.05, 95% confidence intervals (CI): 1.02-1.09, P = 0.004] and (RR: 1.68, 95% CI: 1.40-2.00, P 〈 0.001), respectively. There were no significant differences in all-cause mortal- ity, MACEs, TVR and ST rates between the two groups. The RI rate was lower in the TA plus PCI arm than that in the PCI-only arm with short-term follow-up duration (RR: 0.60, 95% CI: 0.38-0.96, P = 0.03), but there was no significant difference in RI incidence over the me- diumor long-term follow-up periods (RR: 1.00, 95% CI: 0.77-1.29, P = 0.98), and (RR: 0.96, 95% CI: 0.81-1.15, P = 0.69), respectively. There were statistically significant differences in the rates of crude stroke and stroke over the medium- or long-term follow-up periods and the crude stroke rate in the TA plus PCI (RR: 1.60, 95% CI: 1.08-2.38, P = 0.02) and (RR: 1.43, 95% CI: 1.03-1.98, P = 0.03), respectively; this was not observed between the two arms during the short-term follow-up period (RR: 1.47, 95% CI: 0.97-2.21, P = 0.07). Conclusions Routine TA-assisted PCI in STEMI patients can improve myocardial reperfusion and get limited benefits related to the clinical endpoints, which may be associated with stroke risk.展开更多
In this case report, we present the occlusion of multiple coronary artery fistulaes originating from proximal left anterior descending (LAD) and fight sinus valsavla and empting to the pulmonary artery at the same p...In this case report, we present the occlusion of multiple coronary artery fistulaes originating from proximal left anterior descending (LAD) and fight sinus valsavla and empting to the pulmonary artery at the same place. We occluded LAD fistulae by using thrombus aspira- tion catheter as a delivery guide. To the best of our knowlege, this is the first case of occlusion of coronary fistulaes with the help of throm- bus aspiration catheter. Our experience may suggest that thrombus aspiration catheters can be used in treating coronary artery fistulaes with difficult anotomv.展开更多
基金Supported by Natural Science Foundation of Shanxi Province(2007011081 )Returning Brains Project in Shanxi Province(2007066 )Agricultural Science and Technology Achievement Transformation Fund Project(2008GB2A300032)~~
文摘[ Objective] The aim was to establish the method of extracting genomic DNA from sheep blood clot on the basis of the improvement of method for extracting genomic DNA from tissues. [Method]The genomic DNA with complete primary structure and high purity was obtained from the sheep blood clot after the steps of cutting the sheep blood clot with ophthalmic scissors, cell lysis with tissue DNA extracts and digested by proteinase K, extracting with phenol/chloroform and precipitating with ethanol were performed. [ Result] The concentration of the extracted DNA was 159.90 ±0.70 ng/μl and the ratio of the A260/A280 was 1.80 +0.01. The sheep microsatellite locus of BM203 was amplified by using the extracted DNA from the sheep blood clot as template of PCR, and the PCR result was perfect. [Conclusion]This method is simple and feasible, the quantity and quality of the extracted DNA can satisfy the demands for the subsequent researches. It is worth to extending and using for reference.
文摘Background The clinical efficacy and safety of adjunctive thrombus aspiration (TA) in patients with ST-segment elevation myocardial infarction (STEMI) during percutaneous coronary intervention (PCI) remain controversial. Methods Twenty five eligible randomized controlled trials were included to compare the use of thrombus aspiration (TA) with PCI and PCI-only for STEMI. The primary endpoint was all-cause mortality and death. The secondary endpoints were major adverse cardiac events (MACE), recurrent infarction (RI), target vessel revascularization (TVR), stent thrombosis (ST), perfusion surrogate markers and stroke. Results TIMI flow grade 3 and MBG 2-3 were significantly increased in the TA plus PCI arm compared with the PCI-only arm [relative risk (RR): 1.05, 95% confidence intervals (CI): 1.02-1.09, P = 0.004] and (RR: 1.68, 95% CI: 1.40-2.00, P 〈 0.001), respectively. There were no significant differences in all-cause mortal- ity, MACEs, TVR and ST rates between the two groups. The RI rate was lower in the TA plus PCI arm than that in the PCI-only arm with short-term follow-up duration (RR: 0.60, 95% CI: 0.38-0.96, P = 0.03), but there was no significant difference in RI incidence over the me- diumor long-term follow-up periods (RR: 1.00, 95% CI: 0.77-1.29, P = 0.98), and (RR: 0.96, 95% CI: 0.81-1.15, P = 0.69), respectively. There were statistically significant differences in the rates of crude stroke and stroke over the medium- or long-term follow-up periods and the crude stroke rate in the TA plus PCI (RR: 1.60, 95% CI: 1.08-2.38, P = 0.02) and (RR: 1.43, 95% CI: 1.03-1.98, P = 0.03), respectively; this was not observed between the two arms during the short-term follow-up period (RR: 1.47, 95% CI: 0.97-2.21, P = 0.07). Conclusions Routine TA-assisted PCI in STEMI patients can improve myocardial reperfusion and get limited benefits related to the clinical endpoints, which may be associated with stroke risk.
文摘In this case report, we present the occlusion of multiple coronary artery fistulaes originating from proximal left anterior descending (LAD) and fight sinus valsavla and empting to the pulmonary artery at the same place. We occluded LAD fistulae by using thrombus aspira- tion catheter as a delivery guide. To the best of our knowlege, this is the first case of occlusion of coronary fistulaes with the help of throm- bus aspiration catheter. Our experience may suggest that thrombus aspiration catheters can be used in treating coronary artery fistulaes with difficult anotomv.