In the osmotic dehydration process of food,on-line estimation of concentrations of two components in ternary solution with NaCl and sucrose was performed based on multi-functional sensing technique.Moving Least Square...In the osmotic dehydration process of food,on-line estimation of concentrations of two components in ternary solution with NaCl and sucrose was performed based on multi-functional sensing technique.Moving Least Squares were adopted in approximation procedure to estimate the viscosity of such interested ternary solution with the given data set.As a result,in one mode of using total experimental data as calibration data and validation data,the relative deviations of estimated viscosities are less than ±1.24%.In the other mode,by taking total experimental data except the ones for estimation as calibration data,the relative deviations are less than ±3.47%.In the same way,the density of ternary solution can be also estimated with deviations less than ± 0.11% and ± 0.30% respectively in these two models.The satisfactory and accurate results show the extraordinary efficiency of Moving Least Squares behaved in signal approximation for multi-functional sensors.展开更多
Currently,with the fast development of GPS technique,GPS RTK is rapidly being applied to the cadastral survey. GPS RTK technique not only improves efficiency and accelerates the rate of mapping,but also increases econ...Currently,with the fast development of GPS technique,GPS RTK is rapidly being applied to the cadastral survey. GPS RTK technique not only improves efficiency and accelerates the rate of mapping,but also increases economic efficiency. The authors introduced a method for GPS RTK rapid positioning,which uses continuous operational reference system (CORS) as a base station to change the method of previous map drawing by obtaining real-time three-dimensional coordinates of boundary points and statistically analyzing with the three-dimensional coordinates obtained by Total Station to get the accuracy of GPS RTK real-time coordinates. The application of GPS RTK in practical measurement was discussed when the data link had been lost especially. The results show that the three-dimensional coordinates measured by total station can be replaced by real-time three-dimensional coordinates measured by Engineering Star RTK in the CORS.展开更多
In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of tes...In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.展开更多
基金Sponsored by the National Natural Science Foundation of China(Grant No.60672008)the Space Technology Innovation Foundation of China
文摘In the osmotic dehydration process of food,on-line estimation of concentrations of two components in ternary solution with NaCl and sucrose was performed based on multi-functional sensing technique.Moving Least Squares were adopted in approximation procedure to estimate the viscosity of such interested ternary solution with the given data set.As a result,in one mode of using total experimental data as calibration data and validation data,the relative deviations of estimated viscosities are less than ±1.24%.In the other mode,by taking total experimental data except the ones for estimation as calibration data,the relative deviations are less than ±3.47%.In the same way,the density of ternary solution can be also estimated with deviations less than ± 0.11% and ± 0.30% respectively in these two models.The satisfactory and accurate results show the extraordinary efficiency of Moving Least Squares behaved in signal approximation for multi-functional sensors.
文摘Currently,with the fast development of GPS technique,GPS RTK is rapidly being applied to the cadastral survey. GPS RTK technique not only improves efficiency and accelerates the rate of mapping,but also increases economic efficiency. The authors introduced a method for GPS RTK rapid positioning,which uses continuous operational reference system (CORS) as a base station to change the method of previous map drawing by obtaining real-time three-dimensional coordinates of boundary points and statistically analyzing with the three-dimensional coordinates obtained by Total Station to get the accuracy of GPS RTK real-time coordinates. The application of GPS RTK in practical measurement was discussed when the data link had been lost especially. The results show that the three-dimensional coordinates measured by total station can be replaced by real-time three-dimensional coordinates measured by Engineering Star RTK in the CORS.
文摘In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were lmm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure - flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC-4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.