期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
转塔式砂轮架B轴回转机构设计 被引量:3
1
作者 王恒 杜雄 +1 位作者 孙宏睿 王伟荣 《制造技术与机床》 北大核心 2017年第7期172-175,共4页
基于提高复合磨床加工精度,对精密复合磨床的B轴回转机构进行了总体设计和零件结构设计。为了满足电动机惯量与负载惯量的匹配要求,采用了由伺服电动机经谐波减速器的驱动方式,并选择了伺服电动机及谐波减速器的型号;中心采用三支承立... 基于提高复合磨床加工精度,对精密复合磨床的B轴回转机构进行了总体设计和零件结构设计。为了满足电动机惯量与负载惯量的匹配要求,采用了由伺服电动机经谐波减速器的驱动方式,并选择了伺服电动机及谐波减速器的型号;中心采用三支承立柱结构,上端两轴承支撑,下端固定在底座上,根据受力变形模型选择各段轴径及长度;底座装有气动夹盘,在磨削时可抱紧砂轮架体壳,根据磨削力矩要求选择了气动夹盘的型号。该B轴回转机构体积小、回转精度高,应用前景广泛。 展开更多
关键词 磨床砂轮架 B轴 回转机构 结构
下载PDF
主动脉夹层与主动脉弓形态的关系 被引量:2
2
作者 万志敏 朱永宏 《岭南心血管病杂志》 2016年第4期495-498,共4页
主动脉夹层(aortic dissection,AD)具有发病急、病情复杂多变、进展迅速、早期误诊率及漏诊率较高的特点,因而在临床实践中,预后情况并不乐观。因此,深人了解影响AD的危险因素,将极大地促进AD的早期诊断和干预,从而改善AD患者的预后。A... 主动脉夹层(aortic dissection,AD)具有发病急、病情复杂多变、进展迅速、早期误诊率及漏诊率较高的特点,因而在临床实践中,预后情况并不乐观。因此,深人了解影响AD的危险因素,将极大地促进AD的早期诊断和干预,从而改善AD患者的预后。AD的发病机制尚不完全清楚,目前认为,AD发病的相关危险因素主要包括原发性高血压、结缔组织病、外伤、医源性因素、吸毒及妊娠等。目前复习文献提示,主动脉弓形态与AD的发生存在一定的关系,本文尝试就主动脉弓形态与主动脉夹层发生关系的研究做一综述。 展开更多
关键词 主动脉夹层 主动脉弓形态 三支结构 胸主动脉疾病
下载PDF
Numerical Simulation of Intracranial Saccular Aneurysm Treated with Stent with Triangular Wire Cross-Section
3
作者 ZENG Kun QIAO Ai-ke 《Chinese Journal of Biomedical Engineering(English Edition)》 2012年第2期52-59,共8页
The flow resistance of stent with different shapes of wire cross-section can be considered as a factor that influences the condition of inflow and outflow through the stent wire. Different from the traditional stents,... The flow resistance of stent with different shapes of wire cross-section can be considered as a factor that influences the condition of inflow and outflow through the stent wire. Different from the traditional stents, a novel stent with triangular wire cross-section was proposed, and numerical simulations were performed to compare the hemodynamic effect of the novel stent with that of traditional ones. Three constructed aneurysm models were treated with a different kin^l of stent separately, including one with bare circular wire cross-section stent (named CM), one with bare rectangular wire cross-section stent (named RM), one with bare triangular cross-section stent (named TM). An unstented aneurysm model was also constructed to serve as a control (named UM). Numerical simulations of the fluid-structure interaction in these four models were performed under the same boundary conditions using finite element method. The simulation results demonstrated the resistance of the novel stent is lower than RM stent, but higher than that of CM stent. TM stent attributes a higher velocity decreasing and a longer turnover time compared with CM stent. The distribution of wall shear stress indicated the possibility of aneurysm development along the distal wall was higher than the proximal wall, and the top of aneurysm was in the highest risk of rupture. 展开更多
关键词 endovascular stent ANEURYSM hemodynarnics flow resistance
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部