The local gas-phase flow characteristics such as local gas holdup(εg), local bubble velocity (V_b) and local bubble mean diameter(d_b) at a specified point in a gas-liquid-solid three-phase reversedflow jet loop reac...The local gas-phase flow characteristics such as local gas holdup(εg), local bubble velocity (V_b) and local bubble mean diameter(d_b) at a specified point in a gas-liquid-solid three-phase reversedflow jet loop reactor was experimentally investigated by a five-pointconductivity probe. The effects of gas jet flow rate, liquid jet flowrate, solid loading, nozzle diameter and axial position on the localεg, V_b and d_b profiles were discussed. The presence of solids atlow solid concentrations not only increased the local εg and V_b,but also decreased the local d_b. The optimum solid loading for themaximum local εg and V_b together with the minimum local d_b was0.16×10^-3 m^3, corresponding to a solid volume fraction ε_S=2.5/100.展开更多
In this work, the effects of injecting an evaporating liquid jet into solid-gas flow are experimentally investigated. A new model (SHED model) and a supplementary model (spray model) have also been proposed to inv...In this work, the effects of injecting an evaporating liquid jet into solid-gas flow are experimentally investigated. A new model (SHED model) and a supplementary model (spray model) have also been proposed to investigate some flow-field characteristics in three-phase fluidized bed with the mean relative error 4.3% between model and measured results. Some experiments were conducted to study the influences of flow-field parameters such as liquid volumetric flow rate, injection velocity, jet angle and gas superficial velocity as well as solid mass flux on the jet penetration depth (JPD). In addition, independent variables were experimentally employed to propose two empirical correlations for JPD by using multiple regression method and spray cone angle (SCA) by using dimensional analysis technique. The mean relative errors between the JPD and SCA correlations versus ex- perimental data were 7.5% and 3.9%, respectively. In addition, in order to identify the variable effect, a parametric study was carried out. Applying the proposed model can avoid direct use of expensive devices to measureJPD and to nredict dronlet size.展开更多
基金Supported by the National Natural Science Foundation of China (No. 29706006) and the General Corporation of Petrochemical Engineering of China (No.X598021).
文摘The local gas-phase flow characteristics such as local gas holdup(εg), local bubble velocity (V_b) and local bubble mean diameter(d_b) at a specified point in a gas-liquid-solid three-phase reversedflow jet loop reactor was experimentally investigated by a five-pointconductivity probe. The effects of gas jet flow rate, liquid jet flowrate, solid loading, nozzle diameter and axial position on the localεg, V_b and d_b profiles were discussed. The presence of solids atlow solid concentrations not only increased the local εg and V_b,but also decreased the local d_b. The optimum solid loading for themaximum local εg and V_b together with the minimum local d_b was0.16×10^-3 m^3, corresponding to a solid volume fraction ε_S=2.5/100.
文摘In this work, the effects of injecting an evaporating liquid jet into solid-gas flow are experimentally investigated. A new model (SHED model) and a supplementary model (spray model) have also been proposed to investigate some flow-field characteristics in three-phase fluidized bed with the mean relative error 4.3% between model and measured results. Some experiments were conducted to study the influences of flow-field parameters such as liquid volumetric flow rate, injection velocity, jet angle and gas superficial velocity as well as solid mass flux on the jet penetration depth (JPD). In addition, independent variables were experimentally employed to propose two empirical correlations for JPD by using multiple regression method and spray cone angle (SCA) by using dimensional analysis technique. The mean relative errors between the JPD and SCA correlations versus ex- perimental data were 7.5% and 3.9%, respectively. In addition, in order to identify the variable effect, a parametric study was carried out. Applying the proposed model can avoid direct use of expensive devices to measureJPD and to nredict dronlet size.