In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated result...In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.展开更多
High-speed permanent magnetic generators (HSPMG) are common and important power generation equipments used in distributed generation systems. A 100 kW level HSPMG is investigated in this paper, and it is fluid-thermal...High-speed permanent magnetic generators (HSPMG) are common and important power generation equipments used in distributed generation systems. A 100 kW level HSPMG is investigated in this paper, and it is fluid-thermal coupling analyzed. The transient 2D electromagnetic field while machine is under rated operating is analyzed by using the time-stepping FEM, from which the electromagnetic performances and the loss distributions are obtained. Then, an analysis model for fluid-solid temperature field analysis is established. Taking losses as the distributed heat sources, the 3D thermal field is coupling calculated. The variations of heat transfer coefficient and temperature of fluid in stator grooves along the axial direction, as well as the whole region 3D temperature distribution in HSPMG are obtained. Then, considering the variations of heat sources distributions and heat transfer conditions, 3D temperature fields of HSPMG operating under different speeds are calculated, and the influences of machine operating speed on the HSPMG thermal performance are studied, based on which, the functions of machine temperature with operating speed and stator windings resistance are proposed. The obtained conclusions may provide a useful reference for the design and research of HSPMG.展开更多
基金Project(50876116) supported by the National Natural Science Foundation of ChinaProject(2007CK3077) supported by the Innovative Program of Hunan Science and Technology Agency, ChinaProject(1343-77225) supported by the Graduate School of Central South University, China
文摘In order to investigate the temperature distribution, a three-dimensional finite element model (FEM) was developed to simulate the temperature regime in the channels of double-loop inductor, and the simulated results were compared with experimental data from low load trials of a 400 kW inductor. The results of numerical simulations, such as the temperature and Joule heating rate, show reasonable correlation with experimental data. The results indicate that Joule heating rate and the temperature reach the maximum at the comers and the minimum at the centre of the cross-section area. The temperature difference between the inlet and outlet is in an inverse proportion to mass transport. Joule heating rate and the temperature are directly proportional to power frequency. It is concluded that mass transport and power frequency play a critical role in determining the temperature regime and Joule heating rate, the relative permeability of the magnetic core shows no significant influence on temperature regime and Joule heating rate, when the relative permeability varies from 5 000 to 10 000.
基金supported by the National High Technology Research and Development Program of China ("863" Program) (Grant No. 2007AA050501)the Heilongjiang Critical Priority Research (Grant No. GB08A302)
文摘High-speed permanent magnetic generators (HSPMG) are common and important power generation equipments used in distributed generation systems. A 100 kW level HSPMG is investigated in this paper, and it is fluid-thermal coupling analyzed. The transient 2D electromagnetic field while machine is under rated operating is analyzed by using the time-stepping FEM, from which the electromagnetic performances and the loss distributions are obtained. Then, an analysis model for fluid-solid temperature field analysis is established. Taking losses as the distributed heat sources, the 3D thermal field is coupling calculated. The variations of heat transfer coefficient and temperature of fluid in stator grooves along the axial direction, as well as the whole region 3D temperature distribution in HSPMG are obtained. Then, considering the variations of heat sources distributions and heat transfer conditions, 3D temperature fields of HSPMG operating under different speeds are calculated, and the influences of machine operating speed on the HSPMG thermal performance are studied, based on which, the functions of machine temperature with operating speed and stator windings resistance are proposed. The obtained conclusions may provide a useful reference for the design and research of HSPMG.