期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
双目面结构光三重扫描测量系统温漂补偿方法
1
作者 杨濠铭 孙子杰 +1 位作者 孙岩标 邾继贵 《红外与激光工程》 EI CSCD 北大核心 2024年第1期213-224,共12页
双目面结构光三重扫描是在条纹投影双目视觉重建的基础上,追加左、右相机与投影仪构成的单目视觉系统重建点云,在反光和凹凸起伏等表面测量应用上具有更好的点云完整性优势。但由于环境温度变化影响,投影仪产生较大温度漂移,导致双目重... 双目面结构光三重扫描是在条纹投影双目视觉重建的基础上,追加左、右相机与投影仪构成的单目视觉系统重建点云,在反光和凹凸起伏等表面测量应用上具有更好的点云完整性优势。但由于环境温度变化影响,投影仪产生较大温度漂移,导致双目重建点云与单目重建点云发生“分层”现象。为此,文中提出了一种基于正交条纹投影的三重扫描系统温漂在线补偿方法,通过投影仪投射正交条纹来构建双目重建点在投影仪图像中准确的映射关系,并基于双目重建点在投影仪图像中的重投影误差最小化目标函数来求解温漂补偿后的投影仪最优外参数。最后,以金属球和汽车零件作为被测对象进行实验验证,在不依靠标定板等先验信息及繁琐标定流程基础上,所提在线快速补偿方法可以使得双目点云与单目点云温漂量分别减小78.2%和94.3%,极大减轻了温度变化对于三重扫描点云数据拼接影响。 展开更多
关键词 三重扫描 投影仪 正交条纹 温漂补偿
下载PDF
Micropores in G20Mn5N cast steel and their influence on stress distribution
2
作者 Yan Huadong Jin Hui 《Journal of Southeast University(English Edition)》 EI CAS 2024年第3期286-294,共9页
To accurately analyze the impact of casting pores in steel,high-resolution 3D X-ray tomography technology was used to gather detailed statistical information about micropores.These micropores were classified as gas,sh... To accurately analyze the impact of casting pores in steel,high-resolution 3D X-ray tomography technology was used to gather detailed statistical information about micropores.These micropores were classified as gas,shrinkage,and gas-shrinkage pores depending on their formation origin and morphology.Clustering tendencies and affinity parameters were defined to characterize the spatial correlations among these three types of pores.The 3D data from X-ray tomography scans were then integrated into finite element analysis(FEA)software to predict how micropore shape,size,and distribution influence stress distribution within the material.The results show that certain inflection points with small local radii within the cast pores are major contributors to stress concentration.Therefore,cast pores cannot be simply modeled as ideal spherical pores.The sphericity and volume of pores have a significant impact on the stress concentration of the model.Specifically,lower sphericity and larger pore volumes result in higher stress concentrations.Moreover,the internal pores of steel castings exhibit specific global distribution characteristics.Pores located on the surface of the specimen lead to significantly higher stress concentrations compared to those located inside the specimen. 展开更多
关键词 cast steel MICROPORES X-ray tomography 3D reconstruction finite element analysis
下载PDF
New approach to extract phase feature of 3-D objects by wavelength-scanning digital holography
3
作者 SHEN Jin-yuan LI Xian-guo +1 位作者 M. K. Kim CHANG Sheng-jiang 《Optoelectronics Letters》 EI 2006年第2期136-138,共3页
A new approach to extract phase feature of 3-D objects based on wavelength-scanning digital holography and numerical reconstruction technique is proposed in this paper.A number of holograms are recorded on a digital c... A new approach to extract phase feature of 3-D objects based on wavelength-scanning digital holography and numerical reconstruction technique is proposed in this paper.A number of holograms are recorded on a digital camera and reconstructed numerically by a computer with different wavelengths spaced at regular intervals.The theoretical analysis and computer simulations demonstrate that those pixels with the same phase of a 3-D object can focus on the same reconstruction plane.And those pixels with different phase of a 3-D object focus on the different reconstruction planes.Therefore the phase information of a 3-D object can be described by a series of reconstructed images on different planes. 展开更多
关键词 数字全息术 波长扫描 数字相机
下载PDF
锥体加工工艺方法的改进
4
作者 傅义智 王雯 《电讯工程》 1995年第2期49-51,共3页
本文通过对371产品工装中一个锥体加工实例分析,提出了一种简单又实用的锥体加工方法。
关键词 锥体 加工工艺 锥体扫描 夹具
下载PDF
A bony foreign body found in a patient with no bony injury: a case report
5
作者 Devwart Kaushik Narendra Joshi Rakesh Kumar Shiv Kumar Goyal Kamlesh Kumar Sahil Gaba 《Chinese Journal of Traumatology》 CAS CSCD 2014年第6期367-369,共3页
Open fractures with bone loss are a common occurrence following high energy trauma. But usually the bone fragments are lost on the roadside and are not usable. We report a patient who was involved in a head-on collisi... Open fractures with bone loss are a common occurrence following high energy trauma. But usually the bone fragments are lost on the roadside and are not usable. We report a patient who was involved in a head-on collision between two wheelers and presented with a bone fragment embedded in his thigh. Radiological survey revealed no bony injury in that patient. Another patient, who presented at the same time, sustained a segmental fracture of shaft femur and was found to have lost a bone fragment that was similar to the one found in previous patient. CT scan with 3D reconstruction revealed this missing fragment to be the same as that found in previous patient. Both patients had a history of head-on collision while travelling on a two-wheeler. Present case report throws some highlights on the probable mechanism of injury. 展开更多
关键词 Foreign bodies Femoral fractures Accidents traffic
原文传递
上一页 1 下一页 到第