期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
即抛型雌二醇丝印传感器在生物样本中的应用
1
作者 黄泓轲 罗健玮 《化工设计通讯》 CAS 2018年第6期210-210,248,共2页
针对现今雌二醇检测方法缺点,将即抛型雌二醇丝印传感器直接用于小鼠和大鼠血样中雌二醇的测定。结果表明,即抛型雌二醇丝印传感器对雌二醇灵敏度高,可以直接测定生物样本,具备成为进行雌二醇相关性研究和药物筛选及临床诊断辅助的有效... 针对现今雌二醇检测方法缺点,将即抛型雌二醇丝印传感器直接用于小鼠和大鼠血样中雌二醇的测定。结果表明,即抛型雌二醇丝印传感器对雌二醇灵敏度高,可以直接测定生物样本,具备成为进行雌二醇相关性研究和药物筛选及临床诊断辅助的有效工具的潜在价值。 展开更多
关键词 雌二醇 丝印传感器 线性关系
下载PDF
即抛型雌二醇丝印传感器的制备及工艺研究
2
作者 黄泓轲 罗健玮 《化工设计通讯》 CAS 2018年第7期90-91,182,共3页
针对现今雌二醇传感器的缺点,利用丝网印刷技术制备的MWNT/CTAB修饰的即抛型雌二醇丝印传感器选用0.1M的p H=11.0的Na_2CO_3/硼砂缓冲液作为反应缓冲体系,基本可以达到对常规血样中雌二醇特异测定的目的,具有应用于生物样品检测的潜力。
关键词 雌二醇 丝印传感器 循环伏安法
下载PDF
A disposable cobalt-based phosphate sensor based on screen printing technology
3
作者 SONG Lei ZHU Lei +2 位作者 LIU YanChen ZHOU XiaoHong SHI HanChang 《Science China Chemistry》 SCIE EI CAS 2014年第9期1283-1290,共8页
Screen printing is a promising technology because of its simplicity, low-cost, high reproducibility, and efficiency in large-scale production. In this work, a cobalt-based phosphate sensor was successfully fabricated ... Screen printing is a promising technology because of its simplicity, low-cost, high reproducibility, and efficiency in large-scale production. In this work, a cobalt-based phosphate sensor was successfully fabricated using the screen printing technology for the determination of phosphate concentration in the aqueous solution. The disposable sensor consists of a fully integrated cobalt (Co) electrode, which is a layer of carbon conductive ink (C) physically doped with Co powder, and Ag/AgCI reference electrode. The SEM images show that the morphology of the Co electrode changes after exposure to the phosphate solution, indicating that the expendable reaction exists during the measurement. At the Co/C ratio of 1:99, the cobalt-based phosphate sensor shows phosphate-selective potential response in the range of 10-4 to 10-1 mol/L, yielding a detection limit of lxl0-5 mol/L and a slope of over 30 mV/decade in acidic solution (pH 4.5) for HzPO4-. The proposed screen-printed sensor also ex- hibited significant reproducibility with a small repeated sensing deviation (i.e., relative standard deviation (R.S.D.) of 0.5%) on a single sensor and a small electrode-to-electrode deviation (i.e., R.S.D. 〈 3.2%). The recovery study of HzPO4- in real wastewater samples gave values from 95.4% to 101.8%, confirming its application potential in the measurement of phosphate in real samples. Apart from its high selectivity, sensitivity, and stability comparable with a conventional bulk Co-wire electrode, the proposed phosphate sensor still yields many other advantages, such as low price, compactness, ease of use, and the possibility of integration with other analytical devices such as flow injection analysis. 展开更多
关键词 phosphate sensor COBALT screen printing POTENTIOMETRY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部